大口径精密光学调整架的机械设计与计算 被引量:5

Machine Design and Calculation of OpticalPrecision Mount with Large-aperture
在线阅读 下载PDF
导出
摘要 对ns级基频脉冲的激光三倍频效率高于55%的目标,笔者提出了一种高转换效率倍频系统精密调整架的精度设计方法,同时应用这种方法研制了二台D380mm大口镜倍频器调整架,达到了预期的设计技术指标,成功地应用在惯性约束核聚变(ICF)实验中。 Based on the aim of enhancing the efficiency of three times frequency-conversion of laser of ns basic frequency impulse to 55 percent, this paper brings forward a new method of accuracy design with a high efficiency of frequency-conversion scheme and on the basis of this method we developed two frequency-conversion scheme with D380mm, large-aperture , which obtained prospective technical indexes and have been applied into the experiment of ICF.
作者 陈勇
出处 《机械制造与自动化》 2005年第2期23-25,28,共4页 Machine Building & Automation
关键词 倍频器 精度设计 惯性约束核聚变 frequency-conversion scheme accuracy design ICF
  • 相关文献

参考文献4

  • 1朱宝强,詹廷宇,等.三倍频装置的研制[C].高功率激光及等离子体物理研究论文,1995.
  • 2苏建良,沈振军,秦新捷,沈耀宗,孙麟治,朱宝强,詹廷宇.大口径强激光倍频系统精密调整架的研制[J].光学精密工程,1999,7(2):37-42. 被引量:4
  • 3Laser programme annual report 87 LLNL[R]. Livemore Calif UCRL: 4-59.
  • 4丁俊华,等.物理(工)[M].沈阳:辽宁大学出版社.1998.

二级参考文献3

  • 1朱宝强 詹廷宇 等.三倍频装置的研制.高功率激光及等离子体物理研究论文集[M].,1995.73-77.
  • 2朱宝强,高功率激光及等离子体物理研究论文集,1995年,73页
  • 3叶琪根,机构精确度,1986年

共引文献3

同被引文献31

  • 1刘亚平,李娟,张宏.星模拟器的设计与标定[J].红外与激光工程,2006,35(z1):331-334. 被引量:32
  • 2凌宁,张雨东,饶学军,李新阳,王成,胡弈云,姜文汉.用于活体人眼视网膜观察的自适应光学成像系统[J].光学学报,2004,24(9):1153-1158. 被引量:46
  • 3宁桂峰,满翠华.有限元接触分析应用研究[J].现代制造工程,2005(4):66-68. 被引量:23
  • 4张增宝,金玉奇,桑凤亭,张治国,韩新民,王峰,孙以珠.腔镜失调与面型误差对光束质量影响研究[J].强激光与粒子束,2005,17(4):491-494. 被引量:7
  • 5姜文汉.自适应光学技术[J].自然杂志,2006,28(1):7-13. 被引量:84
  • 6马立,荣伟彬,孙立宁,陈伟.用于光学调整的二维纳米级微动台的设计分析(英文)[J].光电工程,2006,33(8):44-50. 被引量:1
  • 7Beranek M W, Chan E Y, Chen C C, et al. Passive Alignment Optical Subassemblies for Military/Aerospace Fiber-optic Transmittermeceiver Applications [C]//IEEE Proceedings. 49th Electronic Components and Technology Conference, San Diego, CA, USA, Jun 1-4, 1999: 188-196.
  • 8Gomez E, Karant Y, Malkoc V, et al. Orthogonal and Least-Squares Based Coordinate Transforms for Optical Alignment Verification in Radiosurgery [C]// International Conference on Information Technology: Coding and Computing, Las Vegas, NV, USA, April 4-6, 2005, 2: 83.
  • 9Khairyanto A, Premachandran C S, Chen W S K, et al. Optical alignment of dual-axis MEMS based scanning optical probe for Optical Coherence Tomography (OCT) application [C]//10th Electronics Packaging Teehnology Conference, Singapore, Dec 9-12, 2008: 945-950.
  • 10Suzuki A, Wakazono Y, Ishikawa T, et al. Low-Cost Optical Subassembly Using VCSEL Pre-Self-Aligned With Optical Fiber forOpticalInterconnectApplications[J].JournalofLightWaveTechnology(S0733-8724), 2009, 27(20): 4516-4523.