导出
摘要 石英晶体微天平(QuartzCrystalMicrobalance)能将所吸附分子质量的微小改变转换成频率的变化并加以测量,具有灵敏度高,稳定性好,通用性强,工作温度范围大,尺寸小和抗干扰强等优点,是一种很理想的敏感器件.将QCM经沸石分子筛AgZSM 5修饰后,对丙酮气体的频率响应进行了测量,实验数据显示对呼出气体的探测能很好地区分出正常人和糖尿病人,对糖尿病的早期诊断具有一定的意义. QCM(Quartz Crystal Microbalance) can transform small mass change caused by adsorbed molecules into frequency shift and measure it. As an ideal transducer,QCM possesses many advantages, such as high sensitivity, good stability, strong generality, wide working temperature, small size and strong anti-jamming ability. Decorated by zeolite molecule sieve Ag ZSM-5, the frequency response of QCM to acetone concentration has been detected. Experiment data shows that the frequency response of QCM to the expiration of normal people is obviously different from that of diabetics,which is significant for the early diagnosis of diabetes.
出处 《复旦学报(自然科学版)》 CAS CSCD 北大核心 2005年第1期41-45,共5页 Journal of Fudan University:Natural Science
基金 国家自然科学基金资助项目(30170266)
关键词 疾病诊断 呼出气体 正常人 糖尿病人 改变 修饰 早期诊断 沸石分子筛 ZSM-5 分子质量 semiconductor technology gas sensor QCM acetone disease diagnosis Ag ZSM-5
  • 相关文献

参考文献14

  • 1Pleil J D, Lindstorm A B.Measurement of volatile organic compounds in exhaled breath as collected in evacuated electropolished canisters [J].J Chromatogr B,1995,665:271-279.
  • 2Ryabtsev S V, Shaposhmick A V. Application of semiconductor gas sensors for medical diagnostics [J].Sensors and Actuators B,1999,59:26-29.
  • 3Gardner J W, Shin H W. An electronic nose system to diagnose illness [J].Sensors and Atuators B,2000,70:19-24.
  • 4Lin Y J, Guo H R. Application of the electronic nose for uremia diagnosis [J].Sensors and Actuators B,2001,76:177-180.
  • 5徐良,余皓,王平.QCM气体传感器的优化设计及应用研究[J].传感技术学报,2002,15(1):77-82. 被引量:3
  • 6Wang Ping,Tan Yi. A novel method for diabetes diagnosis based on eletronics nose [J].Biosensors and Bioelectronics,1997,12(9-10):1031-1036.
  • 7O'Sullivan C K. Commercial quartz crystal microbalances-theory and applications [J].Biosensors and Bioelectronics,1999,14:663-670.
  • 8Sauerbrey G.The use of quartz oscillators for weighing thin layers and for microweighing [J].Z Phys,1959,155:206-222.
  • 9Ward M D. Buttry D A. In situ interfacial mass detection with piezoelectric transducers [J].Science,1990,249:1000-1007.
  • 10Wand Z,Cheeke J D N.Unified approach to analyse mass sensitivities of acoustic gravimetric sensors [J].Electronics Letters,1990,26:1511-1513.

二级参考文献5

  • 1[1]Wang ping, Tan yi, et al. A novel method for diabetes diagnosisbased on slectronics nose[J]. Biosensors & Bioelectronics, 1997;12(9-10):1031-1036
  • 2[2]陈含贻,许志宏等.计算化学及其应用[M].上海科学技术出版社,1987.10
  • 3[3]Nakamura K, Nakamoto T, Moriizumi T. Prediction of quartz crystal microbalance gas sensor responses using a computational chemistry method[J]. Sensors and Actuators B,1999;61:6-11
  • 4[5]A selective organic vapour sensor based on simultaneous measurement of change of mass and resistance of a poly(pyrrole) thin film[J]. J Chem Soc Chem Commun, 1994;137(3):197-204
  • 5沈钟,胶体与表面化学,1991年