期刊文献+

全尺寸墙角火实验中木工板表面火蔓延研究 被引量:10

Surface Flame Spread of Blockboard Lining in a Room Corner Fire Test
在线阅读 下载PDF
导出
摘要 对木工板表面火蔓延进行了全尺寸墙角火实验研究,实验是在符合ISO9705标准的ISOROOM全尺寸实验装置内进行.通过测量材料表面的温度来研究火蔓延的情况,同时还将火蔓延与火灾过程中的重要参数如热释放速率、热流密度和室内温度等进行了比较,分析了相互之间的关系.研究结果为火灾安全设计和计算机数值模拟提供了实验依据. Surface flame spread of the blockboard lining was studied in a full-scale room in accordance with ISO 9705 standard. This research was carried on by measuring the surface temperature of the lining. Some key fire parameters, such as heat release rate, heat flux, room temperatures etc, were also performed and compared with the flame spread. The relationships among these parameters were analyzed. The experimental data and conclusions were beneficial to the development of fire safety design and numerical simulation.
出处 《燃烧科学与技术》 EI CAS CSCD 2004年第6期506-510,共5页 Journal of Combustion Science and Technology
基金 国家自然科学基金资助项目(50076041 50323005) 国家重点基础研究专项经费资助项目(2001CB409603) 国家自然科学基金重大国际合作研究项目(50320120156) 安徽省自然科学基金资助项目(01045407).
关键词 墙角火实验 木工板 火蔓延 热释放速率 room corner test blockboard flame spread heat release rate
  • 相关文献

参考文献7

  • 1Wickstron Ulf. Introduction to EUREFIC [A]. In: Proceedngs of EUREFIC Seminar [C]. London: Interscience Communications Ltd, 1991.
  • 2Karlsson B. Models for calculating flame spread on wall lining materials and the resulting heat release rate in a room [J]. Fire Safety Journal, 1994,23 (4) :365-386.
  • 3Zhang J, Shields T J, Silcock G W H, et al. Behavior of plywood lining in full scale room fire tests [J]. Journal of Applied Fire Science, 1998, 8(1) :3-18.
  • 4ISO 9705. Fire Tests-Full Scale Room Test for Surface Product [S]. Geneva, 1993.
  • 5Shields T J, Silcock G W H, Moghaddam A Z, et al. A comparison of fire retard and non-fire retard wood-based wall linings exposed to fire in an enclosure [J]. Fire and Materials, 1999, 23(1): 17-25.
  • 6Zhang J, Yang F K, Shields T J, et al. Effects of surface flame spread of plywood lining on enclosure fire in a modified ISO room [J]. Journal of Fire Science, 2003,21 (1):67-83.
  • 7Waterman T E. Room flashover-criteria and synthesis [J]. Fire Technology,1968, 4(1) :25-31.

同被引文献83

  • 1曲方,谢正文,袁巧,尚三楼.基于FDS的餐饮业油烟道火灾场景模拟[J].中国计量学院学报,2010,21(2):118-123. 被引量:9
  • 2杨昀,张和平,张军,徐亮,王蔚.用锥形量热仪研究胶合板的燃烧特性[J].燃烧科学与技术,2006,12(2):159-163. 被引量:22
  • 3杨晓菡,彭小芹,卢国建,刘松林.基于CONE数据的材料热释放速率随辐射通量变化的研究[J].消防科学与技术,2006,25(4):469-472. 被引量:6
  • 4周全会.材料对火反应实验方法比较[J].消防科学与技术,2007,26(1):34-37. 被引量:3
  • 5Waterman T.E.R oom flashover-criteria and synthesis[J].Fire Technology,1986,4(1):25-31.
  • 6Karlsson B.Models for calculating flame spread on wall liningmaterials and the resulting heat release rate in a room.Fire Safety Journal,1994,23(4):365-386.
  • 7Ulf Wickstroem.Introduction to EUREFIC[C]//Proceedings of EUREFIC Seminar.London:Interscience Communications Limited,1991.
  • 8Karlsson B.Models for calculating flame spread on wall lining materials and the resulting heat release rate in a room[J].Fire Safety Journal,1994,23(4):365-386.
  • 9Shields T J,Silcock G W H,Moghaddam A Z.A comparison of fire retarded and non-fire retarded wood-based wall linings exposed to fire in an enclosure[J].Fire and Materials,1999,23(1):17-25.
  • 10Gann R G.NIST Research On Less Flammable Materials[J].SAMPE Journal,1996:16-20