期刊文献+

异步发电机并网合闸和线端三相突然短路的瞬态分析 被引量:2

The Transient Analysis of the Surge Current of the Asynchronous Generator Caused by Switching Rush and 3-Phase Sudden Short-Circuit at the Terminals
在线阅读 下载PDF
导出
摘要 本文用综合矢量法分析并网合闸和线端三相突然短路的冲击电流,导出数学模型,机算结果和实验结果吻合较好。另根据S≈0和参数的特点,得出不太复杂的解析式和时间常数,可看出参数的影响,并算出相当准确的结果。 In this paper, space vectors are used to analyse the surge currents of the asynchonous generator caused by switching rush and 3 -phase sudden short-circuit at the terminals. With the mathematical model derived, the computed curres agree well with the oscillograms. According to s≈0 and the feature of the parameters, analytical expressions for the surge currents and the time constants have been worked out to give insight into the influence of the parameters and fairly accurate calculated results have been obtained.
机构地区 福州大学
出处 《电工技术学报》 EI CSCD 北大核心 1993年第3期10-15,共6页 Transactions of China Electrotechnical Society
关键词 异步电动机 冲击电流 短路 : Asynchronous generator Space vector Surge current Sudden short-circuit