With the hypothesis of simple units integration to create new reactivities,a strategy for the synthesis of polyfunctionalized 5-alkenyl-3-carbonylfurans fromγ-hydroxyl enal and 1,3-dicarbonyl compounds is established...With the hypothesis of simple units integration to create new reactivities,a strategy for the synthesis of polyfunctionalized 5-alkenyl-3-carbonylfurans fromγ-hydroxyl enal and 1,3-dicarbonyl compounds is established,featuring readily available starting materials,high efficiency,good functional groups compatibility,green chemistry with high atom economy and only water release,etc.,to provide a series of polyfunctionalized 5-alkenyl-3-carbonylfurans,which could be applied to the late-stage functionalization of naturally occurring compounds and bioactive molecules,as well as the transformation to pyrroles and polycyclic aromatic hydrocarbon via electrocyclic reaction.Theγ-hydroxyl has played an important role in the unexpected process of ring opening isomerization of 2H-pyran to furanones,as confirmed by detailed mechanistic studies.展开更多
A novel chemiluminescence (CL) system was established for the determination of puerarin in pharmaceutical preparations. It was shown that a strong CL signal was observed when Eosin Y reacted with the hydroxyl radica...A novel chemiluminescence (CL) system was established for the determination of puerarin in pharmaceutical preparations. It was shown that a strong CL signal was observed when Eosin Y reacted with the hydroxyl radicals which were generated from Fenton reagent in acidic medium. The CL intensity was decreased significantly when puerarin was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with puerarin concentration. Based on this, a new method for the determination of puerarin using a flow injection chemiluminescence technique was developed. The experimental parameters that affected the CL intensity were optimized. Under the optimal conditions, the linear range for puerarin concentration was 8.0 × 10^-8--2.0 × 10^-6 mol/L (R = 0.9982) with a detection limit of 7.5 × 10^-9 mol/L (S/N= 3) and the relative standard deviation was method was applied to the determination of puerarin in a 1.7% for 4.0× 10^-7 mol/L puerarin (n= 11). The proposed puerarin injection with satisfactory results.展开更多
基金Financial support from National Natural Science Foundation of China(Grant No.22201187)the starting grant from Capital Medical University(Grant No.3100-12400123)。
文摘With the hypothesis of simple units integration to create new reactivities,a strategy for the synthesis of polyfunctionalized 5-alkenyl-3-carbonylfurans fromγ-hydroxyl enal and 1,3-dicarbonyl compounds is established,featuring readily available starting materials,high efficiency,good functional groups compatibility,green chemistry with high atom economy and only water release,etc.,to provide a series of polyfunctionalized 5-alkenyl-3-carbonylfurans,which could be applied to the late-stage functionalization of naturally occurring compounds and bioactive molecules,as well as the transformation to pyrroles and polycyclic aromatic hydrocarbon via electrocyclic reaction.Theγ-hydroxyl has played an important role in the unexpected process of ring opening isomerization of 2H-pyran to furanones,as confirmed by detailed mechanistic studies.
基金Project supported by Guangxi Science Foundation of China (No. 2010GXNSFA013001).
文摘A novel chemiluminescence (CL) system was established for the determination of puerarin in pharmaceutical preparations. It was shown that a strong CL signal was observed when Eosin Y reacted with the hydroxyl radicals which were generated from Fenton reagent in acidic medium. The CL intensity was decreased significantly when puerarin was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with puerarin concentration. Based on this, a new method for the determination of puerarin using a flow injection chemiluminescence technique was developed. The experimental parameters that affected the CL intensity were optimized. Under the optimal conditions, the linear range for puerarin concentration was 8.0 × 10^-8--2.0 × 10^-6 mol/L (R = 0.9982) with a detection limit of 7.5 × 10^-9 mol/L (S/N= 3) and the relative standard deviation was method was applied to the determination of puerarin in a 1.7% for 4.0× 10^-7 mol/L puerarin (n= 11). The proposed puerarin injection with satisfactory results.