In this paper,a new system of semi active structural control with active variable stiffness and damping (AVSD) is suggested.This new system amplifies the structural displacement to dissipate more energy,and in turn,ef...In this paper,a new system of semi active structural control with active variable stiffness and damping (AVSD) is suggested.This new system amplifies the structural displacement to dissipate more energy,and in turn,effectively reduces the structural response in the case of relatively small story drifts,which occur during earthquakes.A predictive instantaneous optimal control algorithm is established for a SDOF structure equipped with an AVSD system Comparative shaking table tests of a 1/4 scale single story structural model with a full scale control device have been conducted.From the experimental and analytical results,it is shown that when compared to structures without control or with the active variable stiffness control alone, the suggested system exhibits higher efficiency in controlling the structural response,requires less energy input,operates with higher reliability,and can be manufactured at a lower cost and used in a wider range of engineering applications.展开更多
In this paper, the method of semi-active control with variable damper is presented to deal with the relatively poor transversal seismic condition of bridge. Based on the LQR control algorithm the control effectiveness...In this paper, the method of semi-active control with variable damper is presented to deal with the relatively poor transversal seismic condition of bridge. Based on the LQR control algorithm the control effectiveness for transverse vibration of pier-beam structure of bridge are discussed. Taking the structure as a multiple-degree of freedom system, the calculating model of structure-variable damper system is set up and the differential equation is derived, combined with practical example the control system is simulated and studied by various semi-active control algorithms and passive strategy with MATLAB. The results show that the semi-active control with variable damper can decrease the transverse vibration effectively and the control effect is obvious.展开更多
Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit(HDU),and the contacting between the robot foot end and the ground is complex and variable,which increases the difficulty of force con...Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit(HDU),and the contacting between the robot foot end and the ground is complex and variable,which increases the difficulty of force control inevitably.In the recent years,although many scholars researched some control methods such as disturbance rejection control,parameter self-adaptive control,impedance control and so on,to improve the force control performance of HDU,the robustness of the force control still needs improving.Therefore,how to simulate the complex and variable load characteristics of the environment structure and how to ensure HDU having excellent force control performance with the complex and variable load characteristics are key issues to be solved in this paper.The force control system mathematic model of HDU is established by the mechanism modeling method,and the theoretical models of a novel force control compensation method and a load characteristics simulation method under different environment structures are derived,considering the dynamic characteristics of the load stiffness and the load damping under different environment structures.Then,simulation effects of the variable load stiffness and load damping under the step and sinusoidal load force are analyzed experimentally on the HDU force control performance test platform,which provides the foundation for the force control compensation experiment research.In addition,the optimized PID control parameters are designed to make the HDU have better force control performance with suitable load stiffness and load damping,under which the force control compensation method is introduced,and the robustness of the force control system with several constant load characteristics and the variable load characteristics respectively are comparatively analyzed by experiment.The research results indicate that if the load characteristics are known,the force control compensation method presented in this paper has positive compensation effects on the load characteristics variation,i.e.,this method decreases the effects of the load characteristics variation on the force control performance and enhances the force control system robustness with the constant PID parameters,thereby,the online PID parameters tuning control method which is complex needs not be adopted.All the above research provides theoretical and experimental foundation for the force control method of the quadruped robot joints with high robustness.展开更多
A modified skyhook-based semi-active controller is proposed for implementing an asymmetric control suspension design with symmetric magneto-rheological (MR) dampers. The controller is formulated in current form, whi...A modified skyhook-based semi-active controller is proposed for implementing an asymmetric control suspension design with symmetric magneto-rheological (MR) dampers. The controller is formulated in current form, which is modulated by integrating a continuous modulation and an asymmetric damping force generation algorithms, so as to effectively minimize switching and hysteretic effects from the MR-damper. The proposed controller is implemented with a quarter-vehicle MR-suspension model, and its relative response characteristics are thus evaluated in terms of defined performance measures under varying amplitude harmonic, rounded pulse and random excitations. The sensitivity of the semi-active suspension performance to variations in controller parameters is thoroughly evaluated. The results illustrate that the proposed skyhook-based asymmetric semi-active MR-suspension controller has superior robustness on the system parameter variations, and can achieve desirable multi-objective suspension performance.展开更多
The design and analysis of an intelligent vehicle suspension with MR dampers should address hybrid semi-active control goals, such as rejection of current-switching discontinuity and MR-damper hysteresis, asymmetric d...The design and analysis of an intelligent vehicle suspension with MR dampers should address hybrid semi-active control goals, such as rejection of current-switching discontinuity and MR-damper hysteresis, asymmetric damping from the symmetric MR-damper design, robustness on the vehicle operation parameter uncertainties and consideration of essential multiple suspension goals. Following the proposed skyhook-based asymmetric semi-active controller (Part I ) for achieving the above goals, herein, a set of suspension performance measures and three kinds of varying amplitude harmonic, rounded pulse and really measured random excitations are systematically defined, and the sensitivity of quarter-vehicle MR-suspension performance to variations in operating conditions is thoroughly analyzed. The results illustrate that the proposed skyhook-based semi-active MR-suspension in the asymmetric mode yields relatively superior dynamic responses to meet the multiple suspension performances of ride, rattle space, road-holding and dynamic tire force transmitted to the pavement, and has desirable robustness on variations in operating conditions of vehicle load and speed and the road roughness.展开更多
This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are pr...This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are proposed as control devices, a LQG-clipped-optimal control algorithm is employed. An active control strategy, shown in previous researches to perform well at controlling the benchmark bridge when uniform earthquake motion was assumed, is also used in this study to control this benchmark bridge with consideration of multiple-support excitations. The performance of active control system is compared to that of the presented semi-active control strategy. Because the MR fluid damper is a con-trollable energy- dissipation device that cannot add mechanical energy to the structural system, the proposed control strategy is fail-safe in that bounded-input, bounded-output stability of the controlled structure is guaranteed. The numerical results demonstrated that the performance of the presented control design is nearly the same as that of the active control system; and that the MR dampers can effectively be used to control seismically excited cable-stayed bridges with multiple-support excitations.展开更多
Structural vibration control was an active research area for the past twenty years because of their potential applications in aerospace structures,civil structures,naval structures,etc.Semi-active vibration control me...Structural vibration control was an active research area for the past twenty years because of their potential applications in aerospace structures,civil structures,naval structures,etc.Semi-active vibration control methods based on piezoelectric actuators and synchronized switch damping on inductance(SSDI)techniques attract the attention of many researchers recently due to their advantages over passive and active methods.In the SSDI method,a switch shunt circuit is connected to the piezoelectric patch to shift the phase and amplify the magnitude of the voltage on the piezoelectric patch.The most important issue in SSDI method is to control the switching actions synchronously with the maximum vibration displacement or maximum strain.Hence,usually a displacement sensor is used to measure the vibration displacement or a collocated piezoelectric sensor is needed to measure the strain of the structure near the piezoelectric actuator.A self-sensing SSDI approach is proposed and applied to the vibration control of a composite beam,which avoids using a separate sensor.In the self-sensing technique,the same piezoelectric element functions as both a sensor and an actuator so that the total number of required piezoelectric elements can be reduced.One problem in the self-sensing actuator,which is the same as that in the traditional collocated piezoelectric sensors,is the noise generated in the sensor signal by the impact of voltage inversion,which may cause extra switching actions and deteriorate control performance.In order to prevent the shunt circuit from over-frequent on-and-off actions,a simple switch control algorithm is proposed.The results of control experiments show that the self-sensing SSDI approach combined with the improved switch control algorithm can effectively suppress over-frequent switching actions and gives good control performance by reducing the vibration amplitude by 45%,about 50%improvement from the traditional SSDI with a separate piezoelectric element and a classical switch.展开更多
In this paper, the characteristics of forces in active control systems connected to adjacent levels of a building are analyzed. The following characteristics are observed: (1) active control can provide significant...In this paper, the characteristics of forces in active control systems connected to adjacent levels of a building are analyzed. The following characteristics are observed: (1) active control can provide significantly superior supplemental damping to a building, but causes a small frequency shift; (2) the linear quadratic regulator (LQR)-based control force is composed of an elastic restoring force component and a damping force component, where the damping force is almost identical to the total control force, however, the elastic restoring force is very small; and (3) the active control forces prevent mction most of the time during the entire control process. These three characteristics imply that active control systems connected to adjacent levels of a building behave like passive damping devices with adjustable parameters, namely damping characteristics in an active control, which is the mechanism used by semi-active control devices to reach similar performance as active control systems. Two indices are defined to quantify the damping characteristics of control forces in active control systems. These two indices can also be used to quantify the capacity of semi-active control to achieve the perfonrlance of active control. Based on the above observations, two principles are founded for optimization of parameters of semi-active control devices and passive dampers. The first is that the maximum output force of a semi-active or passive device to be designed is identical to an active device, called "design principle". The other is the response equivalent principle, which states that the response of a building with semi-active or passive devices is the same as with active devices when the same maximum output force is applied. The design procedure for semi-active control devices and passive dampers is described in detail. Finally, numerical simulations of two benchmark problems is conducted to demonstrate the damping characteristics of active control and investigate the capacity of semi-active control to achieve the same performance as active control.展开更多
A statistic linearization analysis method of bad nolinear hydraulic active damping suspension is provided.Also the optimum control strategy of semi active suspension and graded control strategy based on it are puted ...A statistic linearization analysis method of bad nolinear hydraulic active damping suspension is provided.Also the optimum control strategy of semi active suspension and graded control strategy based on it are puted forward.Experimental researches are carried out on a 2 DOF(degree of freedom) hydraulic active damping suspension test system.The results showed that an excellent control effectiveness could be obtained by using statistic linearization optimum control which unfortunely requests continuously regulationg the damp in an accurate way and costs much in engeering application.On the contrary,the results also showed that graded control is more practicable which has a control effectiveness close to the optimum control and costs less.展开更多
The robotic drilling always generates the axial vibration along the drill bit and the torsional vibration around the drill bit,which will adversely affect the drilling precision.A vibration control mechanism fixed bet...The robotic drilling always generates the axial vibration along the drill bit and the torsional vibration around the drill bit,which will adversely affect the drilling precision.A vibration control mechanism fixed between the end-effector and the robot is proposed,which can suppress the axial and torsional vibrations based on the principle of vibro-impact(VI)damping.The energy dissipation of the system by vibro-impact damping is analyzed.Then,the influence of the structure parameters on the vibration attenuation effect is studied,and a semi-active vibration control method of variable collision clearance is presented.The simulation results show that the control method has effective vibration control performance.展开更多
To establish the algorithm of SAT-TMD system with the wavelet transform(WT),the modal mass participation ratio is proposed to distinguish if the high-rising structure has the characteristic of closely distributed freq...To establish the algorithm of SAT-TMD system with the wavelet transform(WT),the modal mass participation ratio is proposed to distinguish if the high-rising structure has the characteristic of closely distributed frequencies.A time varying analytical model of high-rising structure such as TV-tower with the SAT-TMD is developed.The proposed new idea is to use WT to identify the dominant frequency of structural response in a segment time,and track its variation as a function of time to retune the SAT-TMD.The effectiveness of SAT-TMD is investigated and it is more robust to change in building stiffness and damping than that of the TMD with a fixed frequency corresponding to a fixed mode frequency of the building.It is proved that SAT-TMD is particularly effective in reducing the response even when the building stiffness is changed by ±15%;whereas the TMD loses its effectiveness under such building stiffness variations.展开更多
The virtual inertia and virtual damping affect both the dynamic stability of the virtual synchronous generator(VSG)and the configuration of energy storage,but there is a conflict between them while selecting the virtu...The virtual inertia and virtual damping affect both the dynamic stability of the virtual synchronous generator(VSG)and the configuration of energy storage,but there is a conflict between them while selecting the virtual inertia and virtual damping.An optimal coordination control strategy of micro-grid inverter and energy storage based on variable virtual inertia and damping is proposed to mitigate this conflict.With the integrated optimal constraint of the VSG frequency variation and the energy storage capacity,the virtual inertia and damping of VSG are configured dynamically,adopting linear quadratic optimal control.It can suppress the oscillations of the active power and frequency to improve the stability of VSG and optimally configure the energy storage capacity of VSG simultaneously.The proposed strategy aims to improve the control performance of micro-grid inverter and the system economy.The simulation and experimental results verify the effectiveness of the strategy.展开更多
Compared with wheeled or tracked robots,legged robots exhibit advantages on agile locomotion and higher survival chance for deadly impacts. A buffering strategy is proposed for quadruped robots with non-extreme initia...Compared with wheeled or tracked robots,legged robots exhibit advantages on agile locomotion and higher survival chance for deadly impacts. A buffering strategy is proposed for quadruped robots with non-extreme initial attitudes from the end of air-righting to the steady standing on the ground.This approach consists of landing phase,buffering phase and recovering phase. The variable stiffness control,proportional-derivative( PD) force control and foot trajectory planning are applied to the joints of quadruped robots until the end of the recovering phase. The PD parameters are tuned according to the desired performance of each phase. The above approach is verified on a virtual platform.展开更多
In this paper, a new hybrid control technique, based on a combination of base-isolation and semi-active variable stiffness/damping in a superstructure, is presented. To illustrate the efficiency of the proposed contro...In this paper, a new hybrid control technique, based on a combination of base-isolation and semi-active variable stiffness/damping in a superstructure, is presented. To illustrate the efficiency of the proposed control system, model tests on a mini-electromagnetic shaking table and a numerical simulation were performed. The test and numerical calculation results indicate that this new hybrid control mode with additional damping and smaller additional stiffness can achieve a better control efficiency.展开更多
文摘In this paper,a new system of semi active structural control with active variable stiffness and damping (AVSD) is suggested.This new system amplifies the structural displacement to dissipate more energy,and in turn,effectively reduces the structural response in the case of relatively small story drifts,which occur during earthquakes.A predictive instantaneous optimal control algorithm is established for a SDOF structure equipped with an AVSD system Comparative shaking table tests of a 1/4 scale single story structural model with a full scale control device have been conducted.From the experimental and analytical results,it is shown that when compared to structures without control or with the active variable stiffness control alone, the suggested system exhibits higher efficiency in controlling the structural response,requires less energy input,operates with higher reliability,and can be manufactured at a lower cost and used in a wider range of engineering applications.
文摘In this paper, the method of semi-active control with variable damper is presented to deal with the relatively poor transversal seismic condition of bridge. Based on the LQR control algorithm the control effectiveness for transverse vibration of pier-beam structure of bridge are discussed. Taking the structure as a multiple-degree of freedom system, the calculating model of structure-variable damper system is set up and the differential equation is derived, combined with practical example the control system is simulated and studied by various semi-active control algorithms and passive strategy with MATLAB. The results show that the semi-active control with variable damper can decrease the transverse vibration effectively and the control effect is obvious.
基金Supported by National Key Basic Research Program of China(973 Program,Grant No.2014CB046405)State Key Laboratory of Fluid Power and Mechatronic Systems(Zhejiang University)Open Fund Project(Grant No.GZKF-201502)Hebei Military and Civilian Industry Development Funds Projects of China(Grant No.2015B060)
文摘Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit(HDU),and the contacting between the robot foot end and the ground is complex and variable,which increases the difficulty of force control inevitably.In the recent years,although many scholars researched some control methods such as disturbance rejection control,parameter self-adaptive control,impedance control and so on,to improve the force control performance of HDU,the robustness of the force control still needs improving.Therefore,how to simulate the complex and variable load characteristics of the environment structure and how to ensure HDU having excellent force control performance with the complex and variable load characteristics are key issues to be solved in this paper.The force control system mathematic model of HDU is established by the mechanism modeling method,and the theoretical models of a novel force control compensation method and a load characteristics simulation method under different environment structures are derived,considering the dynamic characteristics of the load stiffness and the load damping under different environment structures.Then,simulation effects of the variable load stiffness and load damping under the step and sinusoidal load force are analyzed experimentally on the HDU force control performance test platform,which provides the foundation for the force control compensation experiment research.In addition,the optimized PID control parameters are designed to make the HDU have better force control performance with suitable load stiffness and load damping,under which the force control compensation method is introduced,and the robustness of the force control system with several constant load characteristics and the variable load characteristics respectively are comparatively analyzed by experiment.The research results indicate that if the load characteristics are known,the force control compensation method presented in this paper has positive compensation effects on the load characteristics variation,i.e.,this method decreases the effects of the load characteristics variation on the force control performance and enhances the force control system robustness with the constant PID parameters,thereby,the online PID parameters tuning control method which is complex needs not be adopted.All the above research provides theoretical and experimental foundation for the force control method of the quadruped robot joints with high robustness.
基金supported by Senior Visiting Scholarship of Chinese Scholarship Council (No.20H05002)Natural Science Foundation of Education Commission of Jiangsu Province, China (No.03KJB510072)Six Categories of Summit Talents of Jiangsu Province, China (No. 2006194).
文摘A modified skyhook-based semi-active controller is proposed for implementing an asymmetric control suspension design with symmetric magneto-rheological (MR) dampers. The controller is formulated in current form, which is modulated by integrating a continuous modulation and an asymmetric damping force generation algorithms, so as to effectively minimize switching and hysteretic effects from the MR-damper. The proposed controller is implemented with a quarter-vehicle MR-suspension model, and its relative response characteristics are thus evaluated in terms of defined performance measures under varying amplitude harmonic, rounded pulse and random excitations. The sensitivity of the semi-active suspension performance to variations in controller parameters is thoroughly evaluated. The results illustrate that the proposed skyhook-based asymmetric semi-active MR-suspension controller has superior robustness on the system parameter variations, and can achieve desirable multi-objective suspension performance.
基金Senior Visiting Scholarship of Chinese Scholarship Council (No.20H05002)Jiangsu Provincial Natural Science Foundation of Education Commission of China (No.03KJB510072)Jiangsu Provincial Six Categories of Summit Talents of China (No.2OO6194)
文摘The design and analysis of an intelligent vehicle suspension with MR dampers should address hybrid semi-active control goals, such as rejection of current-switching discontinuity and MR-damper hysteresis, asymmetric damping from the symmetric MR-damper design, robustness on the vehicle operation parameter uncertainties and consideration of essential multiple suspension goals. Following the proposed skyhook-based asymmetric semi-active controller (Part I ) for achieving the above goals, herein, a set of suspension performance measures and three kinds of varying amplitude harmonic, rounded pulse and really measured random excitations are systematically defined, and the sensitivity of quarter-vehicle MR-suspension performance to variations in operating conditions is thoroughly analyzed. The results illustrate that the proposed skyhook-based semi-active MR-suspension in the asymmetric mode yields relatively superior dynamic responses to meet the multiple suspension performances of ride, rattle space, road-holding and dynamic tire force transmitted to the pavement, and has desirable robustness on variations in operating conditions of vehicle load and speed and the road roughness.
文摘This paper presents a semi-active strategy for seismic protection of a benchmark cable-stayed bridge with consideration of multiple-support excitations. In this control strategy, Magnetorheological (MR) dampers are proposed as control devices, a LQG-clipped-optimal control algorithm is employed. An active control strategy, shown in previous researches to perform well at controlling the benchmark bridge when uniform earthquake motion was assumed, is also used in this study to control this benchmark bridge with consideration of multiple-support excitations. The performance of active control system is compared to that of the presented semi-active control strategy. Because the MR fluid damper is a con-trollable energy- dissipation device that cannot add mechanical energy to the structural system, the proposed control strategy is fail-safe in that bounded-input, bounded-output stability of the controlled structure is guaranteed. The numerical results demonstrated that the performance of the presented control design is nearly the same as that of the active control system; and that the MR dampers can effectively be used to control seismically excited cable-stayed bridges with multiple-support excitations.
基金supported by National Natural Science Foundation of China(Grant No.50775110,Grant No.50830201)Program for Changjiang Scholars and Innovative Research Team of China(Grant No.Irt0906)+1 种基金Aeronautical Science Fund of China(Grant No.20091552017)Jiangsu Provincal Graduate Innovation Program of China(Grant No.CX08B_048Z)
文摘Structural vibration control was an active research area for the past twenty years because of their potential applications in aerospace structures,civil structures,naval structures,etc.Semi-active vibration control methods based on piezoelectric actuators and synchronized switch damping on inductance(SSDI)techniques attract the attention of many researchers recently due to their advantages over passive and active methods.In the SSDI method,a switch shunt circuit is connected to the piezoelectric patch to shift the phase and amplify the magnitude of the voltage on the piezoelectric patch.The most important issue in SSDI method is to control the switching actions synchronously with the maximum vibration displacement or maximum strain.Hence,usually a displacement sensor is used to measure the vibration displacement or a collocated piezoelectric sensor is needed to measure the strain of the structure near the piezoelectric actuator.A self-sensing SSDI approach is proposed and applied to the vibration control of a composite beam,which avoids using a separate sensor.In the self-sensing technique,the same piezoelectric element functions as both a sensor and an actuator so that the total number of required piezoelectric elements can be reduced.One problem in the self-sensing actuator,which is the same as that in the traditional collocated piezoelectric sensors,is the noise generated in the sensor signal by the impact of voltage inversion,which may cause extra switching actions and deteriorate control performance.In order to prevent the shunt circuit from over-frequent on-and-off actions,a simple switch control algorithm is proposed.The results of control experiments show that the self-sensing SSDI approach combined with the improved switch control algorithm can effectively suppress over-frequent switching actions and gives good control performance by reducing the vibration amplitude by 45%,about 50%improvement from the traditional SSDI with a separate piezoelectric element and a classical switch.
基金National Fundamental Research Program (973) Under Grant No. 2007CB714204the R & D Program Under Grant No. 2006BAJ03B06NSFC Under Grant No. 90815027
文摘In this paper, the characteristics of forces in active control systems connected to adjacent levels of a building are analyzed. The following characteristics are observed: (1) active control can provide significantly superior supplemental damping to a building, but causes a small frequency shift; (2) the linear quadratic regulator (LQR)-based control force is composed of an elastic restoring force component and a damping force component, where the damping force is almost identical to the total control force, however, the elastic restoring force is very small; and (3) the active control forces prevent mction most of the time during the entire control process. These three characteristics imply that active control systems connected to adjacent levels of a building behave like passive damping devices with adjustable parameters, namely damping characteristics in an active control, which is the mechanism used by semi-active control devices to reach similar performance as active control systems. Two indices are defined to quantify the damping characteristics of control forces in active control systems. These two indices can also be used to quantify the capacity of semi-active control to achieve the perfonrlance of active control. Based on the above observations, two principles are founded for optimization of parameters of semi-active control devices and passive dampers. The first is that the maximum output force of a semi-active or passive device to be designed is identical to an active device, called "design principle". The other is the response equivalent principle, which states that the response of a building with semi-active or passive devices is the same as with active devices when the same maximum output force is applied. The design procedure for semi-active control devices and passive dampers is described in detail. Finally, numerical simulations of two benchmark problems is conducted to demonstrate the damping characteristics of active control and investigate the capacity of semi-active control to achieve the same performance as active control.
基金This project is supported by Cao Guangbiao High Technology Foundation of Zhejiang University
文摘A statistic linearization analysis method of bad nolinear hydraulic active damping suspension is provided.Also the optimum control strategy of semi active suspension and graded control strategy based on it are puted forward.Experimental researches are carried out on a 2 DOF(degree of freedom) hydraulic active damping suspension test system.The results showed that an excellent control effectiveness could be obtained by using statistic linearization optimum control which unfortunely requests continuously regulationg the damp in an accurate way and costs much in engeering application.On the contrary,the results also showed that graded control is more practicable which has a control effectiveness close to the optimum control and costs less.
基金Supported by the National Natural Science Foundation of China(No.52265013)Natural Science Foundation of Gansu Province(No.20JR5RA457).
文摘The robotic drilling always generates the axial vibration along the drill bit and the torsional vibration around the drill bit,which will adversely affect the drilling precision.A vibration control mechanism fixed between the end-effector and the robot is proposed,which can suppress the axial and torsional vibrations based on the principle of vibro-impact(VI)damping.The energy dissipation of the system by vibro-impact damping is analyzed.Then,the influence of the structure parameters on the vibration attenuation effect is studied,and a semi-active vibration control method of variable collision clearance is presented.The simulation results show that the control method has effective vibration control performance.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50478031)China Postdoctoral Science Foundation(Grant No.2006040240)
文摘To establish the algorithm of SAT-TMD system with the wavelet transform(WT),the modal mass participation ratio is proposed to distinguish if the high-rising structure has the characteristic of closely distributed frequencies.A time varying analytical model of high-rising structure such as TV-tower with the SAT-TMD is developed.The proposed new idea is to use WT to identify the dominant frequency of structural response in a segment time,and track its variation as a function of time to retune the SAT-TMD.The effectiveness of SAT-TMD is investigated and it is more robust to change in building stiffness and damping than that of the TMD with a fixed frequency corresponding to a fixed mode frequency of the building.It is proved that SAT-TMD is particularly effective in reducing the response even when the building stiffness is changed by ±15%;whereas the TMD loses its effectiveness under such building stiffness variations.
基金Supported by National Key R&D Program of China(2016YFB0900300)National Natural Science Foundation of China(51677049).
文摘The virtual inertia and virtual damping affect both the dynamic stability of the virtual synchronous generator(VSG)and the configuration of energy storage,but there is a conflict between them while selecting the virtual inertia and virtual damping.An optimal coordination control strategy of micro-grid inverter and energy storage based on variable virtual inertia and damping is proposed to mitigate this conflict.With the integrated optimal constraint of the VSG frequency variation and the energy storage capacity,the virtual inertia and damping of VSG are configured dynamically,adopting linear quadratic optimal control.It can suppress the oscillations of the active power and frequency to improve the stability of VSG and optimally configure the energy storage capacity of VSG simultaneously.The proposed strategy aims to improve the control performance of micro-grid inverter and the system economy.The simulation and experimental results verify the effectiveness of the strategy.
基金Supported by the National High Technology Research and Development Program of China(No.2015AA042201)the National Natural Science Foundation of China(No.61233014,61305130)+1 种基金the Shandong Provincial Natural Science Foundation(No.ZR2013FQ003,ZR2013EEM027)China Postdoctoral Science Foundation(No.2013M541912)
文摘Compared with wheeled or tracked robots,legged robots exhibit advantages on agile locomotion and higher survival chance for deadly impacts. A buffering strategy is proposed for quadruped robots with non-extreme initial attitudes from the end of air-righting to the steady standing on the ground.This approach consists of landing phase,buffering phase and recovering phase. The variable stiffness control,proportional-derivative( PD) force control and foot trajectory planning are applied to the joints of quadruped robots until the end of the recovering phase. The PD parameters are tuned according to the desired performance of each phase. The above approach is verified on a virtual platform.
基金Societal Commonweal Fund Project (2001DIB20098) Earthquake Science Associate Fund (603011)
文摘In this paper, a new hybrid control technique, based on a combination of base-isolation and semi-active variable stiffness/damping in a superstructure, is presented. To illustrate the efficiency of the proposed control system, model tests on a mini-electromagnetic shaking table and a numerical simulation were performed. The test and numerical calculation results indicate that this new hybrid control mode with additional damping and smaller additional stiffness can achieve a better control efficiency.