期刊文献+
共找到781,212篇文章
< 1 2 250 >
每页显示 20 50 100
Integration of Tracer Test Data to Refine Geostatistical Hydraulic Conductivity Fields Using Sequential Self-Calibration Method 被引量:5
1
作者 胡晓农 蒋小伟 万力 《Journal of China University of Geosciences》 SCIE CSCD 2007年第3期242-256,共15页
On the basis of local measurements of hydraulic conductivity, geostatistical methods have been found to be useful in heterogeneity characterization of a hydraulic conductivity field on a regional scale. However, the m... On the basis of local measurements of hydraulic conductivity, geostatistical methods have been found to be useful in heterogeneity characterization of a hydraulic conductivity field on a regional scale. However, the methods are not suited to directly integrate dynamic production data, such as, hydraulic head and solute concentration, into the study of conductivity distribution. These data, which record the flow and transport processes in the medium, are closely related to the spatial distribution of hydraulic conductivity. In this study, a three-dimensional gradient-based inverse method--the sequential self-calibration (SSC) method--is developed to calibrate a hydraulic conductivity field, initially generated by a geostatistical simulation method, conditioned on tracer test results. The SSC method can honor both local hydraulic conductivity measurements and tracer test data. The mismatch between the simulated hydraulic conductivity field and the reference true one, measured by its mean square error (MSE), is reduced through the SSC conditional study. In comparison with the unconditional results, the SSC conditional study creates the mean breakthrough curve much closer to the reference true curve, and significantly reduces the prediction uncertainty of the solute transport in the observed locations. Further, the reduction of uncertainty is spatially dependent, which indicates that good locations, geological structure, and boundary conditions will affect the efficiency of the SSC study results. 展开更多
关键词 sequential self-calibration tracer test hydraulic conductivity geostatistical simulation inverse problem
在线阅读 下载PDF
NOVEL METHOD FOR ERROR ANALYSIS AND SELF-CALIBRATION OF LASER TRACKING MIRROR MECHANISM 被引量:2
2
作者 OUYANG Jianfei LIU Wanli +2 位作者 QU Xinghua YAN Yonggang WANG Zhankui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第4期1-6,共6页
Laser tracking system (LTS) is an advanced device for large size 3D coordinates measuring with the advantages of broad range, high speed and high accuracy. However, its measuring accuracy is highly dominated by the ... Laser tracking system (LTS) is an advanced device for large size 3D coordinates measuring with the advantages of broad range, high speed and high accuracy. However, its measuring accuracy is highly dominated by the geometric errors of the tracking mirror mechanism. Proper calibration of LTS is essential prior to the use of it for metrology. A kinematics model that describes not only the motion but also the geometric variations of LTS is developed. Through error analysis of the proposed model, it is claimed that gimbals axis misalignments and tracking mirror center off-set are the key contributors to measuring errors of LTS. A self-calibration method is presented of calibrating LTS with planar constraints. Various calibration strategies utilizing single-plane and multiple-plane constraints are proposed for different situations. For each calibration strategy, issues about the error parameter estimation of LTS are exploded to find out in which conditions these parameters can be uniquely estimated. Moreover, these conditions reveal the applicability of the planar constraints to LTS self-calibration. Intensive studies have been made to check validity of the theoretical results. The results show that the measuring accuracy of LTS has increased by 5 times since this technique for calibration is used. 展开更多
关键词 Laser tracking Error analysis self-calibration Planar constraints Tracking mirror
在线阅读 下载PDF
Target self-calibration ratiometric fluorescent sensor based on facile-synthesized europium metal-organic framework for multi-color visual detection of levofloxacin
3
作者 Li Li Lin-Lin Zhang +7 位作者 Yansha Gao Lu-Ying Duan Wuying Yang Xigen Huang Yanping Hong Jiaxin Hong Lin Yuan Limin Lu 《Chinese Chemical Letters》 2025年第7期420-424,共5页
Developing an accurate and visual sensing strategy for trace levels of fluoroquinolone residues that pose threat to food safety and human health is highly desired but remains challenging.Herein,a target selfcalibratio... Developing an accurate and visual sensing strategy for trace levels of fluoroquinolone residues that pose threat to food safety and human health is highly desired but remains challenging.Herein,a target selfcalibration ratiometric fluorescent sensing platform has been designed for sensitive visual detection of levofloxacin(LEV)based on fluorescent europium metal-organic framework(Eu-MOF)probe.Specifically,the Eu-MOF was facilely synthesized via directly mixing Eu^(3+)with 1,10-phenanthroline-2,9-dicarboxylic acid(PDA)ligand at room temperature,which exhibited well-stable red fluorescence at 612 nm.Upon the addition of target LEV,the significant fluorescence quenching from Eu^(3+)was observed owing to the inner filter effect between the Eu-MOF and LEV.While the intrinsic fluorescence for LEV at 462nm was gradually enhanced,thereby realizing the self-calibration ratiometric fluorescence responses to LEV.Through this strategy,LEV can be detected down to 27 nmol/L.Furthermore,a test paper-based Eu-MOF integrated with the smartphone assisted RGB color analysis was exploited for the quantitative monitoring of LEV through the multi-color changes from red to blue,thus achieved portable,convenient and visual detection of LEV in honey and milk samples.Therefore,the developed strategy could provide a useful tool for supporting the practical on-site test in food samples. 展开更多
关键词 Target self-calibration Ratiometric fluorescence Europium metal-organic Framework Multi-color visual detection LEVOFLOXACIN
原文传递
A New Inversion-free Iterative Method for Solving the Nonlinear Matrix Equation and Its Application in Optimal Control
4
作者 GAO Xiangyu XIE Weiwei ZHANG Lina 《应用数学》 北大核心 2026年第1期143-150,共8页
In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to ... In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method. 展开更多
关键词 Nonlinear matrix equation Maximal positive definite solution Inversion-free iterative method Optimal control
在线阅读 下载PDF
Centralized Circumcentered-Reection Method for Solving the Convex Feasibility Problem in Sparse Signal Recovery
5
作者 Chunmei LI Bangjun CHEN Xuefeng DUAN 《Journal of Mathematical Research with Applications》 2026年第1期119-133,共15页
Convex feasibility problems are widely used in image reconstruction,sparse signal recovery,and other areas.This paper is devoted to considering a class of convex feasibility problem arising from sparse signal recovery... Convex feasibility problems are widely used in image reconstruction,sparse signal recovery,and other areas.This paper is devoted to considering a class of convex feasibility problem arising from sparse signal recovery.We rst derive the projection formulas for a vector onto the feasible sets.The centralized circumcentered-reection method is designed to solve the convex feasibility problem.Some numerical experiments demonstrate the feasibility and e ectiveness of the proposed algorithm,showing superior performance compared to conventional alternating projection methods. 展开更多
关键词 convex feasibility problem centralized circumcentered-re ection method sparse signal recovery compressed sensing
原文传递
Numerical Simulation of the Welding Deformation of Marine Thin Plates Based on a Temperature Gradient-thermal Strain Method
6
作者 Lin Wang Yugang Miao +3 位作者 Zhenjian Zhuo Chunxiang Lin Benshun Zhang Duanfeng Han 《哈尔滨工程大学学报(英文版)》 2026年第1期122-135,共14页
Marine thin plates are susceptible to welding deformation owing to their low structural stiffness.Therefore,the efficient and accurate prediction of welding deformation is essential for improving welding quality.The t... Marine thin plates are susceptible to welding deformation owing to their low structural stiffness.Therefore,the efficient and accurate prediction of welding deformation is essential for improving welding quality.The traditional thermal elastic-plastic finite element method(TEP-FEM)can accurately predict welding deformation.However,its efficiency is low because of the complex nonlinear transient computation,making it difficult to meet the needs of rapid engineering evaluation.To address this challenge,this study proposes an efficient prediction method for welding deformation in marine thin plate butt welds.This method is based on the coupled temperature gradient-thermal strain method(TG-TSM)that integrates inherent strain theory with a shell element finite element model.The proposed method first extracts the distribution pattern and characteristic value of welding-induced inherent strain through TEP-FEM analysis.This strain is then converted into the equivalent thermal load applied to the shell element model for rapid computation.The proposed method-particularly,the gradual temperature gradient-thermal strain method(GTG-TSM)-achieved improved computational efficiency and consistent precision.Furthermore,the proposed method required much less computation time than the traditional TEP-FEM.Thus,this study lays the foundation for future prediction of welding deformation in more complex marine thin plates. 展开更多
关键词 Marine thin plate Welding deformation Numerical simulation Temperature gradient-thermal strain method Shell element
在线阅读 下载PDF
A Fractional-N CMOS DPLL with Self-Calibration
7
作者 刘素娟 杨维明 +2 位作者 陈建新 蔡黎明 徐东升 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2005年第11期2085-2091,共7页
A digital phase-locked loop (DPLL) based on a new digital phase-frequency detector is presented. The self-calibration technique is employed to acquire wide lock range,low jitter, and fast acquisition. The DPLL works... A digital phase-locked loop (DPLL) based on a new digital phase-frequency detector is presented. The self-calibration technique is employed to acquire wide lock range,low jitter, and fast acquisition. The DPLL works from 60 to 600MHz at a supply voltage of 1.8V. It also features a fraetional-N synthesizer with digital 2nd-order sigma-delta noise shaping, which can achieve a short lock time,a high frequency resolution,and an improved phase-noise spectrum. The DPLL has been implemented in SMIC 0. 18μm 1.8V 1P6M CMOS technology. The peak-to-peak jitter is less than 0. 8% of the output clock period and the lock time is less than 150 times of the reference clock period after the pre-divider. 展开更多
关键词 digital phase-locked loop phase-frequency detector self-calibration voltage controlled oscillator FRACTIONAL-N
在线阅读 下载PDF
Capacitor self-calibration technique used in time-interleaved successive approximation ADC
8
作者 殷勤 戚韬 +1 位作者 吴光林 吴建辉 《Journal of Southeast University(English Edition)》 EI CAS 2006年第2期164-168,共5页
A capacitor self-calibration circuit used in a successive approximation analog-to-digital converter (SA-ADC) is presented. This capacitor self-calibration circuit can calibrate erroneous data and work with the ADC b... A capacitor self-calibration circuit used in a successive approximation analog-to-digital converter (SA-ADC) is presented. This capacitor self-calibration circuit can calibrate erroneous data and work with the ADC by adding an additional clock period. This circuit is used in a 10 bit 32 Msample/s time-interleaved SA- ADC. The chip is implemented with Chart 0. 25 μm 2. 5 V process and totally occupies an area of 1.4 mm× 1.3 mm. After calibration, the simulated signal-to-noise ratio (SNR) is 59. 586 1 dB and the spurious-free dynamic range (SFDR) is 70. 246 dB at 32 MHz. The measured signal-to-noise and distortion ratio (SINAD) is 44. 82 dB and the SFDR is 63. 760 4 dB when the ADC samples a 5.8 MHz sinusoid wave. 展开更多
关键词 capacitor self-calibration analog-to-digital converter successive approximation time-interleaved
在线阅读 下载PDF
Self-calibration and Compensation of Setting Errors for Surface Profile Measurement of a Microstructured Roll Workpiece 被引量:4
9
作者 GAO Wei XU Bin +2 位作者 TAKEISHI Toshiki SHIMIZU Yuki ITO So 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第1期14-22,共9页
Microstructured roll workpieces have been widely used as functional components in the precision industries. Current researches on quality control have focused on surface profile measurement of microstructured roll wor... Microstructured roll workpieces have been widely used as functional components in the precision industries. Current researches on quality control have focused on surface profile measurement of microstructured roll workpieces, and types of measurement systems and measurement methods have been developed. However, low measurement efficiency and low measurement accuracy caused by setting errors are the common disadvantages for surface profile measurement of microstructured roll workpieces. In order to shorten the measurement time and enhance the measurement accuracy, a method for self-calibration and compensation of setting errors is proposed for surface profile measurement of microstructured roll workpieces. A measurement system is constructed for the measurement, in which a precision spindle is employed to rotate the roll workpiece and an air-bearing displacement sensor with a micro-stylus probe is employed to scan the microstructured surface of the roll workpiece. The resolution of the displacement sensor is 0.14 nm and that of the rotary encoder of the spindle was 0.15r~. Geometrical and mathematical models are established for analyzing the influences of the setting errors of the roll workpiece and the displacement sensor with respect to the axis of the spindle, including the eccentric error of the roll workpiece, the offset error of the sensor axis and the zero point error of the sensor output. Measurement experiments are carded out on a roll workpiece on which periodic microstructures are a period of 133 i^m along the circumferential direction. Experimental results demonstrate the feasibility of the self-compensation method. The proposed method can be used to detect and compensate the setting errors without using any additional accurate artifact. 展开更多
关键词 measurement profile setting error self-calibration COMPENSATION microstructure roll workpiece
在线阅读 下载PDF
New self-calibration approach to space robots based on hand-eye vision 被引量:3
10
作者 刘宇 刘宏 +1 位作者 倪风雷 徐文福 《Journal of Central South University》 SCIE EI CAS 2011年第4期1087-1096,共10页
To overcome the influence of on-orbit extreme temperature environment on the tool pose(position and orientation) accuracy of a space robot,a new self-calibration method based on a measurement camera(hand-eye vision) a... To overcome the influence of on-orbit extreme temperature environment on the tool pose(position and orientation) accuracy of a space robot,a new self-calibration method based on a measurement camera(hand-eye vision) attached to its end-effector was presented.Using the relative pose errors between the two adjacent calibration positions of the space robot,the cost function of the calibration was built,which was different from the conventional calibration method.The particle swarm optimization algorithm(PSO) was used to optimize the function to realize the geometrical parameter identification of the space robot.The above calibration method was carried out through self-calibration simulation of a six-DOF space robot whose end-effector was equipped with hand-eye vision.The results showed that after calibration there was a significant improvement of tool pose accuracy in a set of independent reference positions,which verified the feasibility of the method.At the same time,because it was unnecessary for this method to know the transformation matrix from the robot base to the calibration plate,it reduced the complexity of calibration model and shortened the error propagation chain,which benefited to improve the calibration accuracy. 展开更多
关键词 space robot self-calibration cost function hand-eye vision particle swarm optimization algorithm
在线阅读 下载PDF
A Self-calibration Bundle Adjustment Algorithm Based on Block Matrix Cholesky Decomposition Technology 被引量:3
11
作者 Huasheng SUN Yuan ZHANG 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第1期11-30,共20页
In this study,the problem of bundle adjustment was revisited,and a novel algorithm based on block matrix Cholesky decomposition was proposed to solve the thorny problem of self-calibration bundle adjustment.The innova... In this study,the problem of bundle adjustment was revisited,and a novel algorithm based on block matrix Cholesky decomposition was proposed to solve the thorny problem of self-calibration bundle adjustment.The innovation points are reflected in the following aspects:①The proposed algorithm is not dependent on the Schur complement,and the calculation process is simple and clear;②The complexities of time and space tend to O(n)in the context of world point number is far greater than that of images and cameras,so the calculation magnitude and memory consumption can be reduced significantly;③The proposed algorithm can carry out self-calibration bundle adjustment in single-camera,multi-camera,and variable-camera modes;④Some measures are employed to improve the optimization effects.Experimental tests showed that the proposed algorithm has the ability to achieve state-of-the-art performance in accuracy and robustness,and it has a strong adaptability as well,because the optimized results are accurate and robust even if the initial values have large deviations from the truth.This study could provide theoretical guidance and technical support for the image-based positioning and 3D reconstruction in the fields of photogrammetry,computer vision and robotics. 展开更多
关键词 bundle adjustment self-calibration block matrix Cholesky decomposition
在线阅读 下载PDF
Camera Self-Calibration in Computer Vision with Precise Estimation of Initial Parameters 被引量:1
12
作者 裴明涛 于连庆 +1 位作者 刘鹏 贾云得 《Journal of Beijing Institute of Technology》 EI CAS 2004年第2期152-156,共5页
A key problem that plagues camera self-calibration, namely that the classical self-calibration algorithms are very sensitive to the initial values of the camera intrinsic parameters, is analyzed and a practical soluti... A key problem that plagues camera self-calibration, namely that the classical self-calibration algorithms are very sensitive to the initial values of the camera intrinsic parameters, is analyzed and a practical solution is provided. The effect of the camera intrinsic parameters, mainly the principal point and the skew factor is first discussed. Then a practical method via a controlled motion of the camera is introduced so as to obtain an accurate estimation of these parameters. Feasibility of this approach is illustrated by carrying out comprehensive experiments using synthetic data as well as real image sequences. Unreasonable initial values can often make self-calibration impossible, yet a precise initialization guarantees a better and successful reconstruction. Trying to obtain a more reasonable initialization is worthwhile the effort in camera self-calibration. 展开更多
关键词 self-calibration Euclidean reconstruction computer vision
在线阅读 下载PDF
An improved self-calibration approach based on adaptive genetic algorithm for position-based visual servo 被引量:1
13
作者 Ding LIU Xiongjun WU Yanxi YANG 《控制理论与应用(英文版)》 EI 2008年第3期246-252,共7页
An improved self-calibrating algorithm for visual servo based on adaptive genetic algorithm is proposed in this paper. Our approach introduces an extension of Mendonca-Cipolla and G. Chesi's self-calibration for the ... An improved self-calibrating algorithm for visual servo based on adaptive genetic algorithm is proposed in this paper. Our approach introduces an extension of Mendonca-Cipolla and G. Chesi's self-calibration for the positionbased visual servo technique which exploits the singular value property of the essential matrix. Specifically, a suitable dynamic online cost function is generated according to the property of the three singular values. The visual servo process is carried out simultaneous to the dynamic self-calibration, and then the cost function is minimized using the adaptive genetic algorithm instead of the gradient descent method in G. Chesi's approach. Moreover, this method overcomes the limitation that the initial parameters must be selected close to the true value, which is not constant in many cases. It is not necessary to know exactly the camera intrinsic parameters when using our approach, instead, coarse coding bounds of the five parameters are enough for the algorithm, which can be done once and for all off-line. Besides, this algorithm does not require knowledge of the 3D model of the object. Simulation experiments are carried out and the results demonstrate that the proposed approach provides a fast convergence speed and robustness against unpredictable perturbations of camera parameters, and it is an effective and efficient visual servo algorithm. 展开更多
关键词 Dynamic self-calibration Visual servo Adaptive genetic algorithm Parameter optimizing Essential matrix Computer vision
在线阅读 下载PDF
Self-calibration Applied in Converting Simulation Surveying
14
作者 WANG Ren ZHU Xinhui 《Geo-Spatial Information Science》 2007年第1期57-60,共4页
In the field of converting simulation surveying and traditional close range photogrammetry, it has been developed so far to survey objects by commercial digital camera and this technique is applied widely in every par... In the field of converting simulation surveying and traditional close range photogrammetry, it has been developed so far to survey objects by commercial digital camera and this technique is applied widely in every part of production. In order to get three-dimensional information of objects, commercial digital camera must be examined. For a long time, digital camera has been examined by DLT. Then there must be a high-precision control field. For realizing surveying without control points, a method for self-calibration is proposed. 展开更多
关键词 absolute conic absolute quadric self-calibration
在线阅读 下载PDF
Self-calibration and algorithm of sample set of piezoresistive pressure sensors
15
作者 黄晓因 晋芳伟 周平 《Journal of Shanghai University(English Edition)》 CAS 2007年第2期178-181,共4页
Aiming at piezoresistive pressure sensors, this paper studies simulation of standard pressure by using benchmark current source and self-calibration of the sampling data characteristics. A data fusion algorithm for sa... Aiming at piezoresistive pressure sensors, this paper studies simulation of standard pressure by using benchmark current source and self-calibration of the sampling data characteristics. A data fusion algorithm for sample set is presented which transforms a surface problem into a curve fitting and interpolation problem. The simulation result shows that benchmark current source simulating pressure is successful and data fusion algorithm is effective. The maximum measurement error is only 0.098 kPa and maximum relative error is 0.92% at 0-45 kPa and -10-45~C. 展开更多
关键词 pressure sensor constant current source SAMPLE data fusion self-calibration.
在线阅读 下载PDF
Structural Modal Parameter Recognition and Related Damage Identification Methods under Environmental Excitations:A Review 被引量:5
16
作者 Chao Zhang Shang-Xi Lai Hua-Ping Wang 《Structural Durability & Health Monitoring》 EI 2025年第1期25-54,共30页
Modal parameters can accurately characterize the structural dynamic properties and assess the physical state of the structure.Therefore,it is particularly significant to identify the structural modal parameters accordi... Modal parameters can accurately characterize the structural dynamic properties and assess the physical state of the structure.Therefore,it is particularly significant to identify the structural modal parameters according to the monitoring data information in the structural health monitoring(SHM)system,so as to provide a scientific basis for structural damage identification and dynamic model modification.In view of this,this paper reviews methods for identifying structural modal parameters under environmental excitation and briefly describes how to identify structural damages based on the derived modal parameters.The paper primarily introduces data-driven modal parameter recognition methods(e.g.,time-domain,frequency-domain,and time-frequency-domain methods,etc.),briefly describes damage identification methods based on the variations of modal parameters(e.g.,natural frequency,modal shapes,and curvature modal shapes,etc.)and modal validation methods(e.g.,Stability Diagram and Modal Assurance Criterion,etc.).The current status of the application of artificial intelligence(AI)methods in the direction of modal parameter recognition and damage identification is further discussed.Based on the pre-vious analysis,the main development trends of structural modal parameter recognition and damage identification methods are given to provide scientific references for the optimized design and functional upgrading of SHM systems. 展开更多
关键词 Structural health monitoring data information modal parameters damage identification AI method
在线阅读 下载PDF
Study of the Transport Behavior of Multispherical Proppant in Intersecting Fracture Based on Discrete Element Method 被引量:1
17
作者 Chengyong Peng JianshuWu +2 位作者 Mao Jiang Biao Yin Yishan Lou 《Energy Engineering》 EI 2025年第1期185-201,共17页
To analyze the differences in the transport and distribution of different types of proppants and to address issues such as the short effective support of proppant and poor placement in hydraulically intersecting fract... To analyze the differences in the transport and distribution of different types of proppants and to address issues such as the short effective support of proppant and poor placement in hydraulically intersecting fractures,this study considered the combined impact of geological-engineering factors on conductivity.Using reservoir production parameters and the discrete elementmethod,multispherical proppants were constructed.Additionally,a 3D fracture model,based on the specified conditions of the L block,employed coupled(Computational Fluid Dynamics)CFD-DEM(Discrete ElementMethod)for joint simulations to quantitatively analyze the transport and placement patterns of multispherical proppants in intersecting fractures.Results indicate that turbulent kinetic energy is an intrinsic factor affecting proppant transport.Moreover,the efficiency of placement and migration distance of low-sphericity quartz sand constructed by the DEM in the main fracture are significantly reduced compared to spherical ceramic proppants,with a 27.7%decrease in the volume fraction of the fracture surface,subsequently affecting the placement concentration and damaging fracture conductivity.Compared to small-angle fractures,controlling artificial and natural fractures to expand at angles of 45°to 60°increases the effective support length by approximately 20.6%.During hydraulic fracturing of gas wells,ensuring the fracture support area and post-closure conductivity can be achieved by controlling the sphericity of proppants and adjusting the perforation direction to control the direction of artificial fractures. 展开更多
关键词 Hydraulic fracturing discrete element method PROPPANT SPHERICITY CFD-DEM
在线阅读 下载PDF
Combing the Entropy Weight Method with Fuzzy Mathematics for Assessing the Quality and Post-Ripening Mechanism of High-Temperature Daqu during Storage 被引量:1
18
作者 YANG Junlin YANG Shaojuan +8 位作者 WU Cheng YIN Yanshun YOU Xiaolong ZHAO Wenyu ZHU Anran WANG Jia HU Feng HU Jianfeng WANG Diqiang 《食品科学》 北大核心 2025年第9期48-62,共15页
This study investigated the physicochemical properties,enzyme activities,volatile flavor components,microbial communities,and sensory evaluation of high-temperature Daqu(HTD)during the maturation process,and a standar... This study investigated the physicochemical properties,enzyme activities,volatile flavor components,microbial communities,and sensory evaluation of high-temperature Daqu(HTD)during the maturation process,and a standard system was established for comprehensive quality evaluation of HTD.There were obvious changes in the physicochemical properties,enzyme activities,and volatile flavor components at different storage periods,which affected the sensory evaluation of HTD to a certain extent.The results of high-throughput sequencing revealed significant microbial diversity,and showed that the bacterial community changed significantly more than did the fungal community.During the storage process,the dominant bacterial genera were Kroppenstedtia and Thermoascus.The correlation between dominant microorganisms and quality indicators highlighted their role in HTD quality.Lactococcus,Candida,Pichia,Paecilomyces,and protease activity played a crucial role in the formation of isovaleraldehyde.Acidic protease activity had the greatest impact on the microbial community.Moisture promoted isobutyric acid generation.Furthermore,the comprehensive quality evaluation standard system was established by the entropy weight method combined with multi-factor fuzzy mathematics.Consequently,this study provides innovative insights for comprehensive quality evaluation of HTD during storage and establishes a groundwork for scientific and rational storage of HTD and quality control of sauce-flavor Baijiu. 展开更多
关键词 microbial community high-temperature Daqu comprehensive quality evaluation entropy weight method maturation process
在线阅读 下载PDF
In situ stress inversion using nonlinear stress boundaries achieved by the bubbling method 被引量:1
19
作者 Xige Liu Chenchun Huang +3 位作者 Wancheng Zhu Joung Oh Chengguo Zhang Guangyao Si 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第3期1510-1527,共18页
Due to the heterogeneity of rock masses and the variability of in situ stress,the traditional linear inversion method is insufficiently accurate to achieve high accuracy of the in situ stress field.To address this cha... Due to the heterogeneity of rock masses and the variability of in situ stress,the traditional linear inversion method is insufficiently accurate to achieve high accuracy of the in situ stress field.To address this challenge,nonlinear stress boundaries for a numerical model are determined through regression analysis of a series of nonlinear coefficient matrices,which are derived from the bubbling method.Considering the randomness and flexibility of the bubbling method,a parametric study is conducted to determine recommended ranges for these parameters,including the standard deviation(σb)of bubble radii,the non-uniform coefficient matrix number(λ)for nonlinear stress boundaries,and the number(m)and positions of in situ stress measurement points.A model case study provides a reference for the selection of these parameters.Additionally,when the nonlinear in situ stress inversion method is employed,stress distortion inevitably occurs near model boundaries,aligning with the Saint Venant's principle.Two strategies are proposed accordingly:employing a systematic reduction of nonlinear coefficients to achieve high inversion accuracy while minimizing significant stress distortion,and excluding regions with severe stress distortion near the model edges while utilizing the central part of the model for subsequent simulations.These two strategies have been successfully implemented in the nonlinear in situ stress inversion of the Xincheng Gold Mine and have achieved higher inversion accuracy than the linear method.Specifically,the linear and nonlinear inversion methods yield root mean square errors(RMSE)of 4.15 and 3.2,and inversion relative errors(δAve)of 22.08%and 17.55%,respectively.Therefore,the nonlinear inversion method outperforms the traditional multiple linear regression method,even in the presence of a systematic reduction in the nonlinear stress boundaries. 展开更多
关键词 In situ stress field Inversion method The bubbling method Nonlinear stress boundary Multiple linear regression method
在线阅读 下载PDF
A self-calibrating fluorescent probe for the selective detection and bioimaging of HClO
20
作者 GAO Wei SONG Meiqi +4 位作者 REN Xuan BAI Jianliang SU Jing MA Jianlong WANG Zhijun 《无机化学学报》 北大核心 2025年第6期1173-1182,共10页
In this study,a self-calibrating near-infrared fluorescence probe was designed and synthesized based on the dual-fluorophore strategy utilizing methylene blue and coumarin.The probe utilized methylene blue(emission sp... In this study,a self-calibrating near-infrared fluorescence probe was designed and synthesized based on the dual-fluorophore strategy utilizing methylene blue and coumarin.The probe utilized methylene blue(emission spectrum range:640-740 nm)and coumarin fluorophore(emission spectrum range:440-600 nm)as signal output units,thereby achieving effective spectral separation and highly selective detection of HClO.Under physiological pH conditions,HClO triggers an oxidation-cleavage reaction,releasing methylene blue and coumarin,which emit distinct red and green fluorescence,respectively.This dual-emission feature enabled rapid HClO detection with two-channel detection limits of 25.13 nmol·L^(-1)(green channel)and 31.55 nmol·L^(-1)(red channel).Furthermore,in cell imaging experiments,this probe demonstrated excellent cell membrane permeability and low cytotoxicity,successfully enabling the monitoring of both endogenous and exogenous HClO in living cells.By incorporating a twochannel self-calibration system,the probe effectively mitigated signal variations caused by instrumental or environmental interference,substantially improving detection sensitivity and reliability. 展开更多
关键词 fluorescent probe fluorescent crosstalk self-calibrated hypochloric acid dual channel
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部