Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluct...Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system.展开更多
Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,i...Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,in certain regions,the installation of buried pipes for heat exchangers may be complicated,and these pipes may not always serve as efficient low-temperature heat sources for the heat pumps of the system.To address this issue,the current study explored the use of solar-energy-collecting equipment to supplement buried pipes.In this design,both solar energy and geothermal energy provide low-temperature heat to the heat pump.First,a simulation model of a solar‒ground source heat pump coupling system was established using TRNSYS.The accuracy of this model was validated through experiments and simulations on various system configurations,including varying numbers of buried pipes,different areas of solar collectors,and varying volumes of water tanks.The simulations examined the coupling characteristics of these components and their influence on system performance.The results revealed that the operating parameters of the system remained consistent across the following configurations:three buried pipes,burial depth of 20 m,collector area of 6 m^(2),and water tank volume of 0.5 m^(3);four buried pipes,burial depth of 20 m,collector area of 3 m^(2),and water tank volume of 0.5 m^(3);and five buried pipes with a burial depth of 20 m.Furthermore,the heat collection capacity of the solar collectors spanning an area of 3 m^(2)was found to be equivalent to that of one buried pipe.Moreover,the findings revealed that the solar‒ground source heat pump coupling system demonstrated a lower annual cumulative energy consumption compared to the ground source heat pump system,presenting a reduction of 5.31%compared to the energy consumption of the latter.展开更多
Typhoons can cause large-area blackouts or partial outages of distribution networks.We define a partial outage state in the distribution network as a gray state and propose a gray-start strategy and two-stage distribu...Typhoons can cause large-area blackouts or partial outages of distribution networks.We define a partial outage state in the distribution network as a gray state and propose a gray-start strategy and two-stage distribution network emergency recovery framework.A phase-space reconstruction and stacked integrated model for predicting wind and photovoltaic generation during typhoon disasters is proposed in the first stage.This provides guidance for second-stage post-disaster emergency recovery scheduling.The emergency recovery scheduling model is established in the second stage,and this model is supported by a thermal power-generating unit,mobile emergency generators,and distributed generators.Distributed generation includes wind power generation,photovoltaics,fuel cells,etc.Simultaneously,we con-sider the gray-start based on the pumped storage unit to be an important first step in the emergency recovery strategy.This model is val-idated on the improved IEEE 33 node system,which utilizes data from the 2022 super typhoon“Muifa”in Zhoushan,Zhejiang,China.Simulations indicate the superiority of a gray start with a pumped storage unit and the proposed emergency recovery strategy.展开更多
In the printing industry,vacuum pumps play a critical role in sheet feeding and gripping processes.In order to improve the efficiency of vacuum pumps,By analyzing the internal flow field of the vane type vacuum pump,t...In the printing industry,vacuum pumps play a critical role in sheet feeding and gripping processes.In order to improve the efficiency of vacuum pumps,By analyzing the internal flow field of the vane type vacuum pump,the CFD method was used to simulate the internal flow field of the air pump,and it was found that a main vortex was formed near the rotor of the trailing blade.Based on this observation,a new rotor shape design was proposed in this study,which design places arc-shaped depressed on the circumference of the rotor where the main vortex forms.The existence of the depression facilitated forward motion of the main airflow and thus effectively restricting reverse flow.Simulation results demonstrated that the proposed design is able to decrease pressure-induced torque load on the pump,and the reduction increases for an increasing operating speed.For all three operating speeds tested,the reduction in pressure-induced torque ranges from 5%to up to 10%comparing to the original pump.展开更多
BACKGROUND Proton pump inhibitors(PPIs)are widely used,including among cancer patients,to manage gastroesophageal reflux and other gastric acid-related disorders.Recent evidence suggests associations between long-term...BACKGROUND Proton pump inhibitors(PPIs)are widely used,including among cancer patients,to manage gastroesophageal reflux and other gastric acid-related disorders.Recent evidence suggests associations between long-term PPI use and higher risks for various adverse health outcomes,including greater mortality.AIM To investigate the association between PPI use and all-cause mortality among cancer patients by a comprehensive analysis after adjustment for various confounders and a robust methodological approach to minimize bias.METHODS This retrospective cohort study used data from the TriNetX research network,with electronic health records from multiple healthcare organizations.The study employed a new-user,active comparator design,which compared newly treated PPI users with non-users and newly treated histamine2 receptor antagonists(H2RA)users among adult cancer patients.Newly prescribed PPIs(esomeprazole,lansoprazole,omeprazole,pantoprazole,or rabeprazole)users were compared to non-users or newly prescribed H2RAs(cimetidine,famotidine,nizatidine,or ranitidine)users.The primary outcome was all-cause mortality.Each patient in the main group was matched to a patient in the control group using 1:1 propensity score matching to reduce confounding effects.Multivariable Cox regression models were used to estimate hazard ratios(HRs)and 95% confidence interval(CI).RESULTS During the follow-up period(median 5.4±1.8 years for PPI users and 6.5±1.0 years for non-users),PPI users demonstrated a higher all-cause mortality rate than non-users after 1 year,2 years,and at the end of follow up(HRs:2.34-2.72).Compared with H2RA users,PPI users demonstrated a higher rate of all-cause mortality HR:1.51(95%CI:1.41-1.69).Similar results were observed across sensitivity analyses by excluding deaths from the first 9 months and 1-year post-exposure,confirming the robustness of these findings.In a sensitivity analysis,we analyzed all-cause mortality outcomes between former PPI users and individuals who have never used PPIs,providing insights into the long-term effects of past PPI use.In addition,at 1-year follow-up,the analysis revealed a significant difference in mortality rates between former PPI users and non-users(HR:1.84;95%CI:1.82-1.96).CONCLUSION PPI use among cancer patients was associated with a higher risk of all-cause mortality compared to non-users or H2RA users.These findings emphasize the need for cautious use of PPIs in cancer patients and suggest that alternative treatments should be considered when clinically feasible.However,further studies are needed to corroborate our findings,given the significant adverse outcomes in cancer patients.展开更多
The study was carried out in the Tahoua region at the market gardening sites of the Taddis 1 and 2 valley. Small-scale pumping irrigation is one of the most interesting uses of solar energy. The objective of this stud...The study was carried out in the Tahoua region at the market gardening sites of the Taddis 1 and 2 valley. Small-scale pumping irrigation is one of the most interesting uses of solar energy. The objective of this study is to carry out a comparative analysis of two dewatering pumping systems (Solar Kit and GMP) for water mobilization on a certain number of criteria such as sustainable use, economic aspect and performance. To achieve this, the adapted methodology consisted first of all in the development of a data collection tool in the field. Then flow measurements, estimation of fuel consumption, pressure height, etc., were carried out. Thus, the data collection involved a sample of 120 irrigators who had to use the two (2) types of pumping systems. The collected data were analyzed and processed with appropriate software. The results of the study show that the two pumping systems studied have strengths and constraints. Thus, the solar pumping system has a significant investment cost, very low maintenance and a low operating cost. On the other hand, the system with a generator has a relatively low investment cost (25 to 30 times less than solar), but a relatively high operating, upkeep and maintenance cost. He adds that these assets and constraints must be taken into consideration when an investment is made. This study shows that 74% of producers use GMP compared to 26% who use the Solar Kit. But in practice, the Solar Kit is more reliable for producers from the point of view of planted area, environmental management and investment costs, supply of fuel and lubricant. These results indicate better performance of the solar pumping system compared to GMP at the study sites.展开更多
We present experimental results on kilojoule ultraviolet laser output with 1%spectral broadening.Through stimulated rotational Raman scattering(SRRS)with signal laser injection,we achieve effective spectral broadening...We present experimental results on kilojoule ultraviolet laser output with 1%spectral broadening.Through stimulated rotational Raman scattering(SRRS)with signal laser injection,we achieve effective spectral broadening in short-range propagation,with good retention of the original near-field distribution and time waveform.Theoretical calculations show that 2%bandwidth spectral broadening can be achieved by injecting 20 kW/cm^(2) signal light at 2.2 GW/cm^(2) flux of the pump laser.In addition,high-frequency modulation in the near field can be effectively avoided through replacement of the original random noise signal light by the controllable signal light.The SRRS in the atmospheric environment excited with signal laser injection can provide wide-band light output with controllable beam quality without long-distance propagation,representing an important potential route to realization of broadband laser drivers.展开更多
Cavitation is an unavoidable phenomenon in the operation of centrifugal pumps.Prolonged cavitation can cause significant damage to the components of the flow channel,and in severe cases,it may even interfere with the ...Cavitation is an unavoidable phenomenon in the operation of centrifugal pumps.Prolonged cavitation can cause significant damage to the components of the flow channel,and in severe cases,it may even interfere with the normal energy exchange processes within the pump.Therefore,effective monitoring of cavitation in centrifugal pumps is crucial.This article presents a study that approaches the issue from an acoustic perspective,using experimental methods to gather and analyze acoustic data at the inlet and outlet of centrifugal pumps across various flow rates,with hydrophones as the primary measuring instruments.Results show that flow rate significantly affects noise levels in both non-cavitation and mild cavitation stages,with noise increasing as the flow rate rises.As the cavitation margin(NPSHa)decreases,inlet and outlet noise trends diverge:inlet noise drops sharply,while outlet noise initially increases before sharply decreasing.Both exhibit a distinct zone of abrupt change,where NPSHa values offer earlier cavitation detection than traditional methods.The noise at the pump’s inlet and outlet primarily consists of discrete and broadband noise,with most energy concentrated at discrete frequencies—shaft frequency(24 Hz),blade frequency(144 Hz),and their harmonics.As NPSHa decreases,the inlet’s discrete and broadband noise frequencies decline,while they increase at the outlet.Monitoring changes in these spectrum characteristics provides an additional means of predicting cavitation onset.展开更多
A centrifugal pump with a specific speed ns=67 is considered in this study to investigate the impact of blade cutting(at the outlet edge)on the fluid-induced noise,while keeping all the other geometric parameters unch...A centrifugal pump with a specific speed ns=67 is considered in this study to investigate the impact of blade cutting(at the outlet edge)on the fluid-induced noise,while keeping all the other geometric parameters unchanged.The required unsteady numerical calculations are conducted by applying the RNG k-εturbulence model with the volute dipole being used as the sound source.The results indicate that the internal pressure energy of the centrifugal pump essentially depends on the blade passing frequency and its low-frequency harmonic frequency.Moreover,the pressure pulsation distribution directly affects the noise caused by the centrifugal pump.The sound pressure inside and outside the centrifugal pump and the sound power at the blade passing frequency gradually decrease increasing cutting distance of the impeller blades.When the cutting percentage is 1.21%,that is,the clearance ratio between impeller blade and tongue is 8.57%,the comprehensive performance of the centrifugal pump is the best.展开更多
Although a new-class of heat pumps based on mechanically flexible nanoporous materials holds great poten-tial for the utilization of sustainable refrigerants with a considerably high coefficient of performance(COP),re...Although a new-class of heat pumps based on mechanically flexible nanoporous materials holds great poten-tial for the utilization of sustainable refrigerants with a considerably high coefficient of performance(COP),reducing their system volume remains a challenge.In this study,we explored the potential of this innovative type of heat pump in terms of COP and system volume.To broaden the scope of material exploration,we devised a new thermodynamic heat pump system applicable to soft mesoporous materials,in addition to the conventional system that is suitable only for flexible microporous materials.Several key factors have been identified through the comparison of various nanoporous materials and refrigerants.Our systematic investigation reveals that the combination of mechanically softer nanoporous materials with ammonia refrigerants can achieve a high COP and a reduced system volume.展开更多
Owing to their rolling friction,two-dimensional piston pumps are highly suitable as power components for electro-hydrostatic actuators(EHAs).These pumps are particularly advantageous for applications requiring high ef...Owing to their rolling friction,two-dimensional piston pumps are highly suitable as power components for electro-hydrostatic actuators(EHAs).These pumps are particularly advantageous for applications requiring high efficiency and reliability.However,the ambiguity surrounding the output flow characteristics of individual two-dimensional pumps poses a significant challenge in achieving precise closed-loop control of the EHA positions.To address this issue,this study established a comprehensive numerical model that included gap leakage to analyze the impact of leakage on the output flow characteristics of a two-dimensional piston pump.The validity of the numerical analysis was indirectly confirmed through meticulous measurements of the leakage and volumetric efficiency,ensuring robust results.The research findings indicated that,at lower pump speeds,leakage significantly affected the output flow rate,leading to potential inefficiencies in the system.Conversely,at higher rotational speeds,the impact of leakage was less pronounced,implying that the influence of leakage on the pump outlet flow must be carefully considered and managed for EHAs to perform position servo control.Additionally,the research demonstrates that two-dimensional motion does not have a unique or additional effect on pump leakage,thus simplifying the design considerations.Finally,the study concluded that maintaining an oil-filled leakage environment is beneficial because it helps reduce the impact of leakage and enhances the overall volumetric efficiency of the pump system.展开更多
Erosion in slurry pumps presents a persistent challenge in industrial applications.This study examines the erosion of the static components of a 150ZJ-C42 centrifugal slurry pump,currently in operation at a beneficiat...Erosion in slurry pumps presents a persistent challenge in industrial applications.This study examines the erosion of the static components of a 150ZJ-C42 centrifugal slurry pump,currently in operation at a beneficiation plant,under varying particle conditions.Utilizing high-precision three-dimensional reverse engineering,the pump’s flow passage geometry was reconstructed to facilitate detailed erosion analysis.Focusing on the front and rear baffles of the pump chamber,as well as the volute,erosion patterns were analyzed for different particle volume concentrations and sizes.The results reveal that the highest erosion damage consistently occurs near the volute tongue,with wear being most severe in regions adjacent to the partition plate near the rear cover.Erosion damage intensity in this area correlates positively with particle diameter.Notably,the average erosion rate in the volute surpasses that of the front and rear chamber liners,reaching a value as high as 6.03×10^(-7)kg·m^(-2)·s^(-1)at a particle concentration of 9%and diameter of 0.1 mm,adversely impacting pump stability.For the pump chamber baffles,increased erosion is observed at a particle diameter of 0.05 mm under constant volume concentration conditions,while higher particle concentrations exacerbate localized erosion.展开更多
Centrifugal pumps are extensively employed in ocean engineering,such as ship power systems,water transportation,and mineral exploitation.Pressure fluctuation suppression is essential for the operation stability and se...Centrifugal pumps are extensively employed in ocean engineering,such as ship power systems,water transportation,and mineral exploitation.Pressure fluctuation suppression is essential for the operation stability and service life of the centrifugal pump.In this paper,a new method of bionic structure is proposed for the blade surface of a centrifugal pump,which is inspired by the fish scale and comprises a leading edge,a trailing edge,and two symmetrical side edges.This fish scale structure is applied to the blade pressure and suction surfaces,and an impeller with a fish scale structure is constructed.A test rig for a centrifugal pump is developed to determine the pressure fluctuation in the pump with a prototype impeller and fish scale structure impeller.Results reveal that the dominant frequency of pressure fluctuation in volute is the blade passing frequency(f_(bpf))of 193.33 Hz,which is triggered by the interaction between the tongue and the impeller.The bionic structure of the fish scale effectively suppresses the pressure fluctuation amplitude at f_(bpf).From flow rates of 0.6 Q_(d)to 1.2 Q_(d),the average suppressions in pressure fluctuation amplitudes at f_(bpf)are 20.98%,5.85%,19.20%,and 25.77%.展开更多
The accelerated pace of natural and human-driven climate change presents profound challenges for Earth's systems.Oceans and ice sheets are critical regulators of climate systems,functioning as carbon sinks and the...The accelerated pace of natural and human-driven climate change presents profound challenges for Earth's systems.Oceans and ice sheets are critical regulators of climate systems,functioning as carbon sinks and thermal reservoirs.However,they are increasingly vulnerable to warming and greenhouse gas emissions.展开更多
The enhancement of acid stress tolerance in yeast is critical for advancing its industrial application in biomanufacturing,given yeast's capacity to synthesize a wide range of acidic chemicals.Intracellular acidit...The enhancement of acid stress tolerance in yeast is critical for advancing its industrial application in biomanufacturing,given yeast's capacity to synthesize a wide range of acidic chemicals.Intracellular acidity can be mitigated by endogenous proton pumps;however,this process consumes substantial ATP(Adenosine Triphosphate)and imposes a metabolic burden on cells.To address this problem,this study introduced a light-driven proton pump in yeast to regulate intracellular acidity.The rhodopsin dR from Natrinema thermotolerans was expressed heterologously in Saccharomyces cerevisiae.However,it was found that dR could not be correctly localized to the plasma membrane.To realize its proton pump function,dR was relocated to the plasma membrane by fusing the signal peptide MLS to the N-terminus of dR.The activation of dR-mediated proton translocation across the membrane was successfully achieved through the application of light and retinene.The ability of the system to pump protons is enhanced with light intensity.This system significantly enhanced the survival ability of yeast in acidic environments.An increase in cell biomass of 6.6%was observed at a pH of 2.3 in comparison to the control.This study has expanded the application of photosensitive proteins for acid tolerance and provides a new strategy for the optimization of light-driven biosystems,which can help to enhancepotential of yeast in the biomanufacturing.展开更多
In the context of the accelerated global transition to green and low-carbon energy,China’s energy structure is undergoing profound changes.As of early 2025,the installed capacity of wind and photovoltaic power in Chi...In the context of the accelerated global transition to green and low-carbon energy,China’s energy structure is undergoing profound changes.As of early 2025,the installed capacity of wind and photovoltaic power in China has exceeded 1.4 billion kilowatts,accounting for 42.9%of the total installed power generation capacity,historically surpassing thermal power as the largest power source.However,the randomness,volatility,and intermittency of renewable energy generation pose unprecedented challenges to the power system’s regulatory capacity.In this context,pumped storage,as the most technically mature and economically advantageous large-scale energy storage method,is experiencing explosive growth,providing strategic opportunities for the transformation and upgrading of manufacturing enterprises.展开更多
Pump valve pipeline vibration brings serious safety hazards to the operation of the equipment,for the pump valve system in the process of variable flow,variable speed,variable openings lead to excessive pipeline vibra...Pump valve pipeline vibration brings serious safety hazards to the operation of the equipment,for the pump valve system in the process of variable flow,variable speed,variable openings lead to excessive pipeline vibration.An active damping device(ADD)is used to the vibration of the pump valve pipeline system to apply the control force,to achieve the active control of the pipeline vibration.A pump-valve pipeline vibration test bench was built to compare the control effect of active damping device on pipeline vibration under different pump valve working conditions,and the results show that applying ADD control could effectively suppress the vibration of the pump valve pipeline and enhance the stability of the equipment during operation.At different pump operating rotation frequencies,the vibration amplitude of the pump valve pipeline in working frequency and its multiple frequencies are also effectively suppressed,with the maximum amplitude reduction of more than 60%.For the valve vibration caused by different operating openings,the vibration of the highest reduction of 68%,and the centrifugal pump drive shaft vi-bration reduced by up to 73%,which provides a new idea for vibration control of pump valve pipeline system.展开更多
This research investigates the design and optimization of a photovoltaic(PV)water pumping system to address seasonal water demands across five locations with varying elevation heads.The systemdraws water froma deep we...This research investigates the design and optimization of a photovoltaic(PV)water pumping system to address seasonal water demands across five locations with varying elevation heads.The systemdraws water froma deep well with a static water level of 30mand a dynamic level of 50m,serving agricultural and livestock needs.The objective of this study is to accurately size a PV system that balances energy generation and demand while minimizing grid dependency.Meanwhile,the study presents a comprehensivemethodology to calculate flowrates,pumping power,daily energy consumption,and system capacity.Therefore,the PV system rating,energy output,and economic performance were evaluated using metrics such as discounted payback period(DPP),net present value(NPV),and sensitivity analysis.The results show that a 2.74 kWp PV system is optimal,producing 4767 kWh/year to meet the system’s annual energy demand of 4686 kWh.In summer,energy demand peaks at 1532.7 kWh,while in winter,it drops to 692.1 kWh.Meanwhile,flow rates range from 11.71 m^(3)/h at 57 m head to 10.49 m^(3)/h at 70 m head,demonstrating the system’s adaptability to diverse hydraulic conditions.Economic analysis reveals that at a 5%interest rate and an electricity price of$0.15/kWh,the NPV is$6981.82 with a DPP of 3.76 years.However,a 30%increase in electricity prices improves the NPV to$10,005.18 and shortens the DPP to 2.76 years,whereas a 20%interest rate reduces the NPV to$1038.79 and extends the DPP to 6.08 years.Nevertheless,the annual PV energy generation exceeds total energy demand by 81 kWh,reducing grid dependency and lowering electricity costs.Additionally,the PV system avoids approximately 3956.6 kg of CO_(2) emissions annually,underscoring its environmental benefits over traditional pumping systems.As a result,this study highlights the economic and environmental viability of PV-powered water pumping systems,offering actionable insights for sustainable energy solutions in agriculture.展开更多
基金supported by the National Natural Science Foundation of China(Project No.52377082)the Scientific Research Program of Jilin Provincial Department of Education(Project No.JJKH20230123KJ).
文摘Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system.
基金supported by 2024 Central Guidance Local Science and Technology Development Fund Project"Study on the mechanism and evaluation method of thermal pollution in water bodies,as well as research on thermal carrying capacity".(Grant 246Z4506G)Key Research and Development Project in Hebei Province:"Key Technologies and Equipment Research and Demonstration of Multiple Energy Complementary(Electricity,Heat,Cold System)for Solar Energy,Geothermal Energy,Phase Change Energy"(Grant 236Z4310G)the Hebei Academy of Sciences Key Research and Development Program"Research on Heat Transfer Mechanisms and Efficient Applications of Intermediate and Deep Geothermal Energy"(22702)。
文摘Ground source heat pump systems demonstrate significant potential for northern rural heating applications;however,the effectiveness of these systems is often limited by challenging geological conditions.For instance,in certain regions,the installation of buried pipes for heat exchangers may be complicated,and these pipes may not always serve as efficient low-temperature heat sources for the heat pumps of the system.To address this issue,the current study explored the use of solar-energy-collecting equipment to supplement buried pipes.In this design,both solar energy and geothermal energy provide low-temperature heat to the heat pump.First,a simulation model of a solar‒ground source heat pump coupling system was established using TRNSYS.The accuracy of this model was validated through experiments and simulations on various system configurations,including varying numbers of buried pipes,different areas of solar collectors,and varying volumes of water tanks.The simulations examined the coupling characteristics of these components and their influence on system performance.The results revealed that the operating parameters of the system remained consistent across the following configurations:three buried pipes,burial depth of 20 m,collector area of 6 m^(2),and water tank volume of 0.5 m^(3);four buried pipes,burial depth of 20 m,collector area of 3 m^(2),and water tank volume of 0.5 m^(3);and five buried pipes with a burial depth of 20 m.Furthermore,the heat collection capacity of the solar collectors spanning an area of 3 m^(2)was found to be equivalent to that of one buried pipe.Moreover,the findings revealed that the solar‒ground source heat pump coupling system demonstrated a lower annual cumulative energy consumption compared to the ground source heat pump system,presenting a reduction of 5.31%compared to the energy consumption of the latter.
基金supported in part by the National Nat-ural Science Foundation of China(52177110)Key Pro-gram of the National Natural Science Foundation of China(U22B20106,U2142206)+2 种基金Shenzhen Science and Technology Program(JCYJ20210324131409026)the Science and Technology Project of the State Grid Corpo-ration of China(5200-202319382A-2-3-XG)State Grid Zhejiang Elctric Power Co.,Ltd.Science and Tech-nology Project(B311DS24001A).
文摘Typhoons can cause large-area blackouts or partial outages of distribution networks.We define a partial outage state in the distribution network as a gray state and propose a gray-start strategy and two-stage distribution network emergency recovery framework.A phase-space reconstruction and stacked integrated model for predicting wind and photovoltaic generation during typhoon disasters is proposed in the first stage.This provides guidance for second-stage post-disaster emergency recovery scheduling.The emergency recovery scheduling model is established in the second stage,and this model is supported by a thermal power-generating unit,mobile emergency generators,and distributed generators.Distributed generation includes wind power generation,photovoltaics,fuel cells,etc.Simultaneously,we con-sider the gray-start based on the pumped storage unit to be an important first step in the emergency recovery strategy.This model is val-idated on the improved IEEE 33 node system,which utilizes data from the 2022 super typhoon“Muifa”in Zhoushan,Zhejiang,China.Simulations indicate the superiority of a gray start with a pumped storage unit and the proposed emergency recovery strategy.
文摘In the printing industry,vacuum pumps play a critical role in sheet feeding and gripping processes.In order to improve the efficiency of vacuum pumps,By analyzing the internal flow field of the vane type vacuum pump,the CFD method was used to simulate the internal flow field of the air pump,and it was found that a main vortex was formed near the rotor of the trailing blade.Based on this observation,a new rotor shape design was proposed in this study,which design places arc-shaped depressed on the circumference of the rotor where the main vortex forms.The existence of the depression facilitated forward motion of the main airflow and thus effectively restricting reverse flow.Simulation results demonstrated that the proposed design is able to decrease pressure-induced torque load on the pump,and the reduction increases for an increasing operating speed.For all three operating speeds tested,the reduction in pressure-induced torque ranges from 5%to up to 10%comparing to the original pump.
文摘BACKGROUND Proton pump inhibitors(PPIs)are widely used,including among cancer patients,to manage gastroesophageal reflux and other gastric acid-related disorders.Recent evidence suggests associations between long-term PPI use and higher risks for various adverse health outcomes,including greater mortality.AIM To investigate the association between PPI use and all-cause mortality among cancer patients by a comprehensive analysis after adjustment for various confounders and a robust methodological approach to minimize bias.METHODS This retrospective cohort study used data from the TriNetX research network,with electronic health records from multiple healthcare organizations.The study employed a new-user,active comparator design,which compared newly treated PPI users with non-users and newly treated histamine2 receptor antagonists(H2RA)users among adult cancer patients.Newly prescribed PPIs(esomeprazole,lansoprazole,omeprazole,pantoprazole,or rabeprazole)users were compared to non-users or newly prescribed H2RAs(cimetidine,famotidine,nizatidine,or ranitidine)users.The primary outcome was all-cause mortality.Each patient in the main group was matched to a patient in the control group using 1:1 propensity score matching to reduce confounding effects.Multivariable Cox regression models were used to estimate hazard ratios(HRs)and 95% confidence interval(CI).RESULTS During the follow-up period(median 5.4±1.8 years for PPI users and 6.5±1.0 years for non-users),PPI users demonstrated a higher all-cause mortality rate than non-users after 1 year,2 years,and at the end of follow up(HRs:2.34-2.72).Compared with H2RA users,PPI users demonstrated a higher rate of all-cause mortality HR:1.51(95%CI:1.41-1.69).Similar results were observed across sensitivity analyses by excluding deaths from the first 9 months and 1-year post-exposure,confirming the robustness of these findings.In a sensitivity analysis,we analyzed all-cause mortality outcomes between former PPI users and individuals who have never used PPIs,providing insights into the long-term effects of past PPI use.In addition,at 1-year follow-up,the analysis revealed a significant difference in mortality rates between former PPI users and non-users(HR:1.84;95%CI:1.82-1.96).CONCLUSION PPI use among cancer patients was associated with a higher risk of all-cause mortality compared to non-users or H2RA users.These findings emphasize the need for cautious use of PPIs in cancer patients and suggest that alternative treatments should be considered when clinically feasible.However,further studies are needed to corroborate our findings,given the significant adverse outcomes in cancer patients.
文摘The study was carried out in the Tahoua region at the market gardening sites of the Taddis 1 and 2 valley. Small-scale pumping irrigation is one of the most interesting uses of solar energy. The objective of this study is to carry out a comparative analysis of two dewatering pumping systems (Solar Kit and GMP) for water mobilization on a certain number of criteria such as sustainable use, economic aspect and performance. To achieve this, the adapted methodology consisted first of all in the development of a data collection tool in the field. Then flow measurements, estimation of fuel consumption, pressure height, etc., were carried out. Thus, the data collection involved a sample of 120 irrigators who had to use the two (2) types of pumping systems. The collected data were analyzed and processed with appropriate software. The results of the study show that the two pumping systems studied have strengths and constraints. Thus, the solar pumping system has a significant investment cost, very low maintenance and a low operating cost. On the other hand, the system with a generator has a relatively low investment cost (25 to 30 times less than solar), but a relatively high operating, upkeep and maintenance cost. He adds that these assets and constraints must be taken into consideration when an investment is made. This study shows that 74% of producers use GMP compared to 26% who use the Solar Kit. But in practice, the Solar Kit is more reliable for producers from the point of view of planted area, environmental management and investment costs, supply of fuel and lubricant. These results indicate better performance of the solar pumping system compared to GMP at the study sites.
基金supported by the Presidential Foundation of CAEP(Grant No.YZJJZL2023116)the National Nature Science Foundation of China(Grant No.12275249)the Youth Talent Fund of the Laser Fusion Research Center,CAEP(Grant Nos.RCFCZ7-2024-2 and RCFPD4-2020-4).
文摘We present experimental results on kilojoule ultraviolet laser output with 1%spectral broadening.Through stimulated rotational Raman scattering(SRRS)with signal laser injection,we achieve effective spectral broadening in short-range propagation,with good retention of the original near-field distribution and time waveform.Theoretical calculations show that 2%bandwidth spectral broadening can be achieved by injecting 20 kW/cm^(2) signal light at 2.2 GW/cm^(2) flux of the pump laser.In addition,high-frequency modulation in the near field can be effectively avoided through replacement of the original random noise signal light by the controllable signal light.The SRRS in the atmospheric environment excited with signal laser injection can provide wide-band light output with controllable beam quality without long-distance propagation,representing an important potential route to realization of broadband laser drivers.
基金supported by the National Natural Science Foundation of China(Research Project No.52169018).
文摘Cavitation is an unavoidable phenomenon in the operation of centrifugal pumps.Prolonged cavitation can cause significant damage to the components of the flow channel,and in severe cases,it may even interfere with the normal energy exchange processes within the pump.Therefore,effective monitoring of cavitation in centrifugal pumps is crucial.This article presents a study that approaches the issue from an acoustic perspective,using experimental methods to gather and analyze acoustic data at the inlet and outlet of centrifugal pumps across various flow rates,with hydrophones as the primary measuring instruments.Results show that flow rate significantly affects noise levels in both non-cavitation and mild cavitation stages,with noise increasing as the flow rate rises.As the cavitation margin(NPSHa)decreases,inlet and outlet noise trends diverge:inlet noise drops sharply,while outlet noise initially increases before sharply decreasing.Both exhibit a distinct zone of abrupt change,where NPSHa values offer earlier cavitation detection than traditional methods.The noise at the pump’s inlet and outlet primarily consists of discrete and broadband noise,with most energy concentrated at discrete frequencies—shaft frequency(24 Hz),blade frequency(144 Hz),and their harmonics.As NPSHa decreases,the inlet’s discrete and broadband noise frequencies decline,while they increase at the outlet.Monitoring changes in these spectrum characteristics provides an additional means of predicting cavitation onset.
文摘A centrifugal pump with a specific speed ns=67 is considered in this study to investigate the impact of blade cutting(at the outlet edge)on the fluid-induced noise,while keeping all the other geometric parameters unchanged.The required unsteady numerical calculations are conducted by applying the RNG k-εturbulence model with the volute dipole being used as the sound source.The results indicate that the internal pressure energy of the centrifugal pump essentially depends on the blade passing frequency and its low-frequency harmonic frequency.Moreover,the pressure pulsation distribution directly affects the noise caused by the centrifugal pump.The sound pressure inside and outside the centrifugal pump and the sound power at the blade passing frequency gradually decrease increasing cutting distance of the impeller blades.When the cutting percentage is 1.21%,that is,the clearance ratio between impeller blade and tongue is 8.57%,the comprehensive performance of the centrifugal pump is the best.
文摘Although a new-class of heat pumps based on mechanically flexible nanoporous materials holds great poten-tial for the utilization of sustainable refrigerants with a considerably high coefficient of performance(COP),reducing their system volume remains a challenge.In this study,we explored the potential of this innovative type of heat pump in terms of COP and system volume.To broaden the scope of material exploration,we devised a new thermodynamic heat pump system applicable to soft mesoporous materials,in addition to the conventional system that is suitable only for flexible microporous materials.Several key factors have been identified through the comparison of various nanoporous materials and refrigerants.Our systematic investigation reveals that the combination of mechanically softer nanoporous materials with ammonia refrigerants can achieve a high COP and a reduced system volume.
基金Supported by National Natural Science Foundation of China(Grant No.52205072).
文摘Owing to their rolling friction,two-dimensional piston pumps are highly suitable as power components for electro-hydrostatic actuators(EHAs).These pumps are particularly advantageous for applications requiring high efficiency and reliability.However,the ambiguity surrounding the output flow characteristics of individual two-dimensional pumps poses a significant challenge in achieving precise closed-loop control of the EHA positions.To address this issue,this study established a comprehensive numerical model that included gap leakage to analyze the impact of leakage on the output flow characteristics of a two-dimensional piston pump.The validity of the numerical analysis was indirectly confirmed through meticulous measurements of the leakage and volumetric efficiency,ensuring robust results.The research findings indicated that,at lower pump speeds,leakage significantly affected the output flow rate,leading to potential inefficiencies in the system.Conversely,at higher rotational speeds,the impact of leakage was less pronounced,implying that the influence of leakage on the pump outlet flow must be carefully considered and managed for EHAs to perform position servo control.Additionally,the research demonstrates that two-dimensional motion does not have a unique or additional effect on pump leakage,thus simplifying the design considerations.Finally,the study concluded that maintaining an oil-filled leakage environment is beneficial because it helps reduce the impact of leakage and enhances the overall volumetric efficiency of the pump system.
基金The authors gratefully acknowledge the filnancial support of the National Natural Science Foundation of China(Grant No.52369018)the Major Training Program of University Research and Innovation Platform of Gansu Provincial Department of Education(No.2024CXPT-09)+1 种基金the Administration of Central Funds Guiding the Local Science and Technology Development,China(Grant No.23ZYQA0320)the Double First-Class Key Program of Gansu Provincial Department of Education,Grant No.GCJ2022-38.
文摘Erosion in slurry pumps presents a persistent challenge in industrial applications.This study examines the erosion of the static components of a 150ZJ-C42 centrifugal slurry pump,currently in operation at a beneficiation plant,under varying particle conditions.Utilizing high-precision three-dimensional reverse engineering,the pump’s flow passage geometry was reconstructed to facilitate detailed erosion analysis.Focusing on the front and rear baffles of the pump chamber,as well as the volute,erosion patterns were analyzed for different particle volume concentrations and sizes.The results reveal that the highest erosion damage consistently occurs near the volute tongue,with wear being most severe in regions adjacent to the partition plate near the rear cover.Erosion damage intensity in this area correlates positively with particle diameter.Notably,the average erosion rate in the volute surpasses that of the front and rear chamber liners,reaching a value as high as 6.03×10^(-7)kg·m^(-2)·s^(-1)at a particle concentration of 9%and diameter of 0.1 mm,adversely impacting pump stability.For the pump chamber baffles,increased erosion is observed at a particle diameter of 0.05 mm under constant volume concentration conditions,while higher particle concentrations exacerbate localized erosion.
基金supported by the Open Fund of Science and Technology on Thermal Energy and Power Laboratory[TPL2021A02]the State Key Laboratory of Hydroscience and Engineering[sklhse-2023-E-01].
文摘Centrifugal pumps are extensively employed in ocean engineering,such as ship power systems,water transportation,and mineral exploitation.Pressure fluctuation suppression is essential for the operation stability and service life of the centrifugal pump.In this paper,a new method of bionic structure is proposed for the blade surface of a centrifugal pump,which is inspired by the fish scale and comprises a leading edge,a trailing edge,and two symmetrical side edges.This fish scale structure is applied to the blade pressure and suction surfaces,and an impeller with a fish scale structure is constructed.A test rig for a centrifugal pump is developed to determine the pressure fluctuation in the pump with a prototype impeller and fish scale structure impeller.Results reveal that the dominant frequency of pressure fluctuation in volute is the blade passing frequency(f_(bpf))of 193.33 Hz,which is triggered by the interaction between the tongue and the impeller.The bionic structure of the fish scale effectively suppresses the pressure fluctuation amplitude at f_(bpf).From flow rates of 0.6 Q_(d)to 1.2 Q_(d),the average suppressions in pressure fluctuation amplitudes at f_(bpf)are 20.98%,5.85%,19.20%,and 25.77%.
文摘The accelerated pace of natural and human-driven climate change presents profound challenges for Earth's systems.Oceans and ice sheets are critical regulators of climate systems,functioning as carbon sinks and thermal reservoirs.However,they are increasingly vulnerable to warming and greenhouse gas emissions.
基金supported by the National Key Research and Development Program of China(2023YFA0913600)the National Natural Science Foundation of China(22138006,22278240).
文摘The enhancement of acid stress tolerance in yeast is critical for advancing its industrial application in biomanufacturing,given yeast's capacity to synthesize a wide range of acidic chemicals.Intracellular acidity can be mitigated by endogenous proton pumps;however,this process consumes substantial ATP(Adenosine Triphosphate)and imposes a metabolic burden on cells.To address this problem,this study introduced a light-driven proton pump in yeast to regulate intracellular acidity.The rhodopsin dR from Natrinema thermotolerans was expressed heterologously in Saccharomyces cerevisiae.However,it was found that dR could not be correctly localized to the plasma membrane.To realize its proton pump function,dR was relocated to the plasma membrane by fusing the signal peptide MLS to the N-terminus of dR.The activation of dR-mediated proton translocation across the membrane was successfully achieved through the application of light and retinene.The ability of the system to pump protons is enhanced with light intensity.This system significantly enhanced the survival ability of yeast in acidic environments.An increase in cell biomass of 6.6%was observed at a pH of 2.3 in comparison to the control.This study has expanded the application of photosensitive proteins for acid tolerance and provides a new strategy for the optimization of light-driven biosystems,which can help to enhancepotential of yeast in the biomanufacturing.
文摘In the context of the accelerated global transition to green and low-carbon energy,China’s energy structure is undergoing profound changes.As of early 2025,the installed capacity of wind and photovoltaic power in China has exceeded 1.4 billion kilowatts,accounting for 42.9%of the total installed power generation capacity,historically surpassing thermal power as the largest power source.However,the randomness,volatility,and intermittency of renewable energy generation pose unprecedented challenges to the power system’s regulatory capacity.In this context,pumped storage,as the most technically mature and economically advantageous large-scale energy storage method,is experiencing explosive growth,providing strategic opportunities for the transformation and upgrading of manufacturing enterprises.
基金The Fundamental Research Funds for the Central Universities(JD2423)。
文摘Pump valve pipeline vibration brings serious safety hazards to the operation of the equipment,for the pump valve system in the process of variable flow,variable speed,variable openings lead to excessive pipeline vibration.An active damping device(ADD)is used to the vibration of the pump valve pipeline system to apply the control force,to achieve the active control of the pipeline vibration.A pump-valve pipeline vibration test bench was built to compare the control effect of active damping device on pipeline vibration under different pump valve working conditions,and the results show that applying ADD control could effectively suppress the vibration of the pump valve pipeline and enhance the stability of the equipment during operation.At different pump operating rotation frequencies,the vibration amplitude of the pump valve pipeline in working frequency and its multiple frequencies are also effectively suppressed,with the maximum amplitude reduction of more than 60%.For the valve vibration caused by different operating openings,the vibration of the highest reduction of 68%,and the centrifugal pump drive shaft vi-bration reduced by up to 73%,which provides a new idea for vibration control of pump valve pipeline system.
文摘This research investigates the design and optimization of a photovoltaic(PV)water pumping system to address seasonal water demands across five locations with varying elevation heads.The systemdraws water froma deep well with a static water level of 30mand a dynamic level of 50m,serving agricultural and livestock needs.The objective of this study is to accurately size a PV system that balances energy generation and demand while minimizing grid dependency.Meanwhile,the study presents a comprehensivemethodology to calculate flowrates,pumping power,daily energy consumption,and system capacity.Therefore,the PV system rating,energy output,and economic performance were evaluated using metrics such as discounted payback period(DPP),net present value(NPV),and sensitivity analysis.The results show that a 2.74 kWp PV system is optimal,producing 4767 kWh/year to meet the system’s annual energy demand of 4686 kWh.In summer,energy demand peaks at 1532.7 kWh,while in winter,it drops to 692.1 kWh.Meanwhile,flow rates range from 11.71 m^(3)/h at 57 m head to 10.49 m^(3)/h at 70 m head,demonstrating the system’s adaptability to diverse hydraulic conditions.Economic analysis reveals that at a 5%interest rate and an electricity price of$0.15/kWh,the NPV is$6981.82 with a DPP of 3.76 years.However,a 30%increase in electricity prices improves the NPV to$10,005.18 and shortens the DPP to 2.76 years,whereas a 20%interest rate reduces the NPV to$1038.79 and extends the DPP to 6.08 years.Nevertheless,the annual PV energy generation exceeds total energy demand by 81 kWh,reducing grid dependency and lowering electricity costs.Additionally,the PV system avoids approximately 3956.6 kg of CO_(2) emissions annually,underscoring its environmental benefits over traditional pumping systems.As a result,this study highlights the economic and environmental viability of PV-powered water pumping systems,offering actionable insights for sustainable energy solutions in agriculture.