期刊文献+
共找到811篇文章
< 1 2 41 >
每页显示 20 50 100
The Effect of Oxygen Partial Pressure during Active Layer Deposition on Bias Stability of a-InGaZnO TFTs 被引量:2
1
作者 黄晓明 武辰飞 +3 位作者 陆海 任芳芳 朱洪波 王永进 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第7期171-174,共4页
The effect of oxygen partial pressure (Po2) during the channel layer deposition on bias stability of amorphous indium-gallium-zinc oxide (a-IGZO) thin film transistors (TFTs) is investigated. As Po2 increases fr... The effect of oxygen partial pressure (Po2) during the channel layer deposition on bias stability of amorphous indium-gallium-zinc oxide (a-IGZO) thin film transistors (TFTs) is investigated. As Po2 increases from 10% to 30%, it is found that the device shows enhanced bias stress stability with significantly reduced threshold voltage drift under positive gate bias stress. Based on the x-ray photoelectron spectroscopy measurement, the concentration of oxygen vacancies (Or) within the a-IGZO layer is suppressed by increasing Po2. Meanwhile, the low-frequency noise analysis indicates that the average trap density near the channel/dielectric interface continuously drops with increasing Po2. Therefore, the improved interface quality with increasing Po2 during the channel layer deposition can be attributed to the reduction of interface Ov-related defects, which agrees with the enhanced bias stress stability of the a-IGZO TFTs. 展开更多
关键词 TFT The effect of Oxygen partial Pressure during Active Layer Deposition on Bias Stability of a-InGaZnO TFTs
原文传递
Analysis of Partial Volume Effects on Accurate Measurement of the Hippocampus Volume
2
作者 Maryam Hajiesmaeili Jamshid Dehmeshki Tim Ellis 《Journal of Electronic Science and Technology》 CAS 2014年第2期182-186,共5页
Hippocampal volume loss is an important biomarker in distinguishing subjects with Alzheimer's disease (AD) and its measurement in magnetic resonance images (MRI) is influenced by partial volume effects (PVE). T... Hippocampal volume loss is an important biomarker in distinguishing subjects with Alzheimer's disease (AD) and its measurement in magnetic resonance images (MRI) is influenced by partial volume effects (PVE). This paper describes a post-processing approach to quantify PVE for correction of the hippocampal volume by using a spatial fuzzyC-means (SFCM) method. The algorithm is evaluated on a dataset of 20 T1-weighted MRI scans sampled at two different resolutions. The corrected volumes for left and right hippocampus (HC) which are 23% and 18% for the low resolution and 6% and 5% for the high resolution datasets, respectively are lower than hippocampal volume results from manual segmentation. Results show the importance of applying this technique in AD detection with low resolution datasets. 展开更多
关键词 HIPPOCAMPUS magnetic resonance images partial volume effects spatial fuzzy C-means
暂未订购
Effect of salt solutions on chain structure of partially hydrolyzed polyacrylamide 被引量:3
3
作者 张青 周吉生 +2 位作者 翟永爱 刘凤岐 高歌 《Journal of Central South University》 SCIE EI CAS 2008年第S1期80-83,共4页
The effect of salt solutions(NaCl,Na2SO4 and CaCl2) on the conformational properties of partially hydrolyzed polyacrylamide(HPAM) was investigated by using static laser light scattering(SLLS).The special interaction b... The effect of salt solutions(NaCl,Na2SO4 and CaCl2) on the conformational properties of partially hydrolyzed polyacrylamide(HPAM) was investigated by using static laser light scattering(SLLS).The special interaction between CaCl2 solution and HPAM was also researched.Experimental results show that the chain structure of HPAM is interrelated with the charge density,the kind and the concentration of salt solutions.The mean-square radius of gyration(Rz) and the second virial coefficient(A2) of HPAM decrease with increasing concentration of salt solutions,and the salt effect tends towards the maximum when the concentration of salt solution is increased to some amount. 展开更多
关键词 partialLY hydrolyzed polyacrylamide(HPAM) SALT effect chain structure static laser light scattering(SLLS)
在线阅读 下载PDF
Effects of terlipressin versus splenectomy on liver regeneration after partial hepatectomy in rats: What we know so far? 被引量:6
4
作者 antonios athanasiou eleftherios spartalis +4 位作者 mairead hennessy michael spartalis demetrios moris christos damaskos emmanouil pikoulis 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2018年第1期91-92,共2页
To the editor:We read with great interest the article entitled "Comparative study of the effects of terlipressin versus splenectomy on liver regeneration after partial hepatectomy in rats" by Ulmer et al.[1]... To the editor:We read with great interest the article entitled "Comparative study of the effects of terlipressin versus splenectomy on liver regeneration after partial hepatectomy in rats" by Ulmer et al.[1].The aim of this study was to analyse the impact of terlipressin ver- 展开更多
关键词 effects of terlipressin versus splenectomy on liver regeneration after partial hepatectomy in rats What we know so far
暂未订购
Partial Volume Effect on MR Elastography
5
作者 Daiki Ito Tomokazu Numano +3 位作者 Kazuyuki Mizuhara Toshikatsu Washio Masaki Misawa Naotaka Nitta 《Open Journal of Medical Imaging》 2017年第4期131-143,共13页
Magnetic resonance elastography (MRE) allows the quantitative assessment of the stiffness of tissues based on the tissue response to oscillatory shear stress. Shear wave displacements of the tissues are encoded as pha... Magnetic resonance elastography (MRE) allows the quantitative assessment of the stiffness of tissues based on the tissue response to oscillatory shear stress. Shear wave displacements of the tissues are encoded as phase shifts and converted to stiffness (elastogram). Generally, a partial volume effect occurs when different materials are encompassed on the same voxel. In MRE, however, the partial volume effect occurs even if the voxel is filled with the same materials because wave displacements due to vibrations are spatially distributed. The purpose of this study was to investigate how the partial volume effect can affect the phase shift and the elastogram in MRE. We assumed that the partial volume effect appears only in the slice thickness direction and performed a simulation and MRE experiment with various slice thicknesses (1 - 19 mm), two types of imaging plane (coronal and axial) and two types of vibration frequency (100 and 200 Hz). The results of the simulation and the MRE experiment were similar, and indicated that the phase shift and the elastogram changed variously depending on the slice thickness, the wave pattern and the vibration frequency, even if the voxel was filled with the same material. To reduce the partial volume effect, it is necessary to perform the MRE under the following conditions: Use a wave pattern which barely causes this artefact, a smaller voxel size and a lower vibration frequency. 展开更多
关键词 Magnetic RESONANCE ELASTOGRAPHY partial Volume effect ARTEFACT ELASTICITY VISCOELASTICITY
暂未订购
Effect of the Partial Substitution of V for Nb on the Magnetic Properties of Fe-based Nanocrystalline Alloy
6
作者 Guiqin ZHOU, Fazeng LIAN and Guozhen LI (Institute of Materials and Metallurgy, Northeastern University, Shenyang 110006,China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第6期643-644,共2页
The variation of the magnetic properties of the nanocrystalline alloys for the partial substitution of V for Nb with crystallizing treatment temperature and time was investigated. The variation law of the magnetic pro... The variation of the magnetic properties of the nanocrystalline alloys for the partial substitution of V for Nb with crystallizing treatment temperature and time was investigated. The variation law of the magnetic properties with the annealing temperature and time is essentially the same. The magnetic properties of the Fe-based nanocrystalline alloys for the partial substitution of V for Nb reduce, and the crystallizing treatment temperature of the alloys increases. The optimum properties of Fe74Cu1Nb3Si13B9 nanocrystalline alloys crystallized at 550℃x60 min are μ0=9.2xl0^4, μm=54.8xl0^4, Hc=1.14 A/m and Bs=1.26 T. The best properties for Fe74Cu1Nb3Si13B9 alloys annealed at 560℃x60 min are μ0=8.79x10^4, μm=50.18xl0^4, Hc=1.26 A/m and Bs=1.24 T. 展开更多
关键词 Fe effect of the partial Substitution of V for Nb on the Magnetic Properties of Fe-based Nanocrystalline Alloy
在线阅读 下载PDF
Effect of topiramate on partial excitatory amino acids in hippocampal dentate gyrus of rats after alcohol withdrawal
7
作者 Qinghua Yang Guang Wu +2 位作者 Haiying Jiang Yuanzhe Jin Songbiao Cui 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第2期147-150,共4页
BACKGROUND: Many researches have indicated that the imbalances of various amino acid transmitters and neurotransmitters in brain are involved in the formation of alcohol withdrawal, especially that glutamic acid is o... BACKGROUND: Many researches have indicated that the imbalances of various amino acid transmitters and neurotransmitters in brain are involved in the formation of alcohol withdrawal, especially that glutamic acid is one of the important transmitters for alcohol tolerance in central nervous system. OBJECTIVE: To observe the changes of excitatory amino acids in hippocampal dentate gyrus in rats with long-term alcohol drinking after withdrawal under consciousness, and investigate the therapeutic effect of topiramate on alcohol withdrawal. DESIGN : A randomized control animal experiment SETTING : Department of Neurology, Affiliated Hospital of Yanbian University MATERIALS: Thirty male Wistar rats of 4 months old, weighing 300-350 g, were purchased from the Experimental Animal Department, Medical College of Yanbian University. Topiramate was produced by Swish Cilag Company, and the batch number was 02CS063. METHODS: The experiments were carried out in the Department of Physiology, Medical College of Yanbian University from August 2005 to February 2006. ① The rats were divided randomly into three groups: control group (n=10), alcohol group (n=10) and topiramate-treated group (n=10). Rats in the alcohol group and topiramate-treated group were given intragastric perfusion of 500 g/L alcohol (10 mL/kg), once a day for 4 weeks successively, and then those in the topiramate-treated group were treated with 80 mg/kg topiramate at 24 hours after the last perfusion of alcohol, once a day for 3 days successively. Rats in the control group were intragastricly given isovolume saline. ② The withdrawal symptoms were assessed at 6, 30, 48 and 72 hours after the last perfusion of alcohol by using the withdrawal rating scale set by Erden et al, which had four observational indexes of stereotyped behaviors, agitation, tail stiffness and abnormal posture, each index was scored by 5 points, the higher the score, the more obvious the symptoms. ③ The contents of aspartic acid and glutamic acid in hippocampal dentate gyrus were detected with microdialysis technique and high-performance liquid chromatograpy (HPLC) respectively at 6, 30, 48 and 72 hours after the last perfusion of alcohol in the three groups. MAIN OUTCOME MEASURES : ① Scoring results of alcohol withdrawal symptoms; ② Changes of the contents of aspartic acid and glutamic acid in hippocampal dentate gyrus at the alcohol withdrawal symptoms, and the effects of topiramate. RESULTS: Seven rats were excluded due to inaccurate localization and natural death, and 23 rats were involved in the analysis of results. ①In the alcohol group, the scores of alcohol withdrawal symptoms at 30 and 48 hours after the last perfusion of alcohol were obviously higher than those in the control group (10.50±0.96, 14.17±1.25; 3.50±0.92, 3.16±0,31; P 〈 0.01). In the topiramate-treated group, the scores at 30 hours after the last perfusion of alcohol (6.06±0.82, 3.50±0.92, P 〈 0.05), and the withdrawal scores at 48 and 72 hours were close to those in the control group (4.57±0.58, 3.30±0.71; 3.16±0.31, 3.66±0.67; P 〉 0.05).② Changes of the contents of glutamic acid in hippocampal dentate gyrus: In the alcohol group, the content of glutamic acid at 48 hours after the last perfusion of alcohol was significantly increased as compared with that at 6 hours [(143.32±11.42)%, (99.12±0.69)%; P 〈 0.05], and that at 72 hours was close to that at 6 hours [(78.50±16.40)%, (99.12±0.69)%; P 〉 0.05]. The contents of glutamic acid had no obvious differences at 6, 30, 48 and 72 hours after the last perfusion of alcohol in the topiramate-treated group [(100.30±0.37)%, (118.91±10.40)%, (99.55±12.81)%, (99.08±11.42)%; P 〉 0.05], The content of glutamic acid at 48 hours after the last perfusion of alcohol in the topiramate-treated group was obviously lower than that in the alcohol group (P 〈 0.05), and those at 30 and 72 hours were close (P 〉 0.05). ③ Changes of the contents of aspartic acid in hippocampal dentate gyrus: In the alcohol group, the contents of aspartic acid at 30 and 48 hours after the last perfusion of alcohol were significantly increased as compared with that at 6 hours [(126.60±8.67)%, (129.17±10.40)%, (99.25±0.87)%; P 〈 0.05], and that at 72 hours was close to that at 6 hours [(89.87±9.93)%, (99.25±0.87)%; P 〉 0.05]. The contents of aspartic acid had no obvious differences at 6, 30, 48 and 72 hours after the last perfusion of alcohol in the topiramate-treated group [(100.27±0.32)%, (120.81 ±12.63)%, (98.91±7.83)%, (85.92±8.07)%; P 〉 0.05]. The content of aspartic acid at 48 hours after the last perfusion of alcohol in the topiramate-treated group was obviously lower than that in the alcohol group (P 〈 0.05), and those at 30 and 72 hours were close (P 〉 0.05). CONCLUSION: ① The occurrences of alcohol withdrawal symptoms are correlated with the increased contents of excitatory amino acids in hippocampal dentate gyrus in rats. ② Topiramate can alleviate the alcohol withdrawal symptoms, which may be correlated with the decreased contents of excitatory amino acids in hippocampal dentate gyrus in rats. 展开更多
关键词 effect of topiramate on partial excitatory amino acids in hippocampal dentate gyrus of rats after alcohol withdrawal
暂未订购
Impact of back-gate bias on the hysteresis effect in partially depleted SOI MOSFETs
8
作者 罗杰馨 陈静 +4 位作者 周建华 伍青青 柴展 余涛 王曦 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第5期473-478,共6页
The hysteresis effect in the output characteristics,originating from the floating body effect,has been measured in partially depleted(PD) silicon-on-insulator(SOI) MOSFETs at different back-gate biases.I D hystere... The hysteresis effect in the output characteristics,originating from the floating body effect,has been measured in partially depleted(PD) silicon-on-insulator(SOI) MOSFETs at different back-gate biases.I D hysteresis has been developed to clarify the hysteresis characteristics.The fabricated devices show the positive and negative peaks in the I D hysteresis.The experimental results show that the I D hysteresis is sensitive to the back gate bias in 0.13-渭m PD SOI MOSFETs and does not vary monotonously with the back-gate bias.Based on the steady-state Shockley-Read-Hall(SRH) recombination theory,we have successfully interpreted the impact of the back-gate bias on the hysteresis effect in PD SOI MOSFETs. 展开更多
关键词 floating body effect hysteresis effect back gate bias partially depleted (PD) SOl
原文传递
Efficient Shrinkage Estimation about the Partially Linear Varying Coefficient Model with Random Effect for Longitudinal Data
9
作者 Wanbin Li 《Open Journal of Statistics》 2016年第5期862-872,共12页
In this paper, an efficient shrinkage estimation procedure for the partially linear varying coefficient model (PLVC) with random effect is considered. By selecting the significant variable and estimating the nonzero c... In this paper, an efficient shrinkage estimation procedure for the partially linear varying coefficient model (PLVC) with random effect is considered. By selecting the significant variable and estimating the nonzero coefficient, the model structure specification is accomplished by introducing a novel penalized estimating equation. Under some mild conditions, the asymptotic properties for the proposed model selection and estimation results, such as the sparsity and oracle property, are established. Some numerical simulation studies and a real data analysis are presented to examine the finite sample performance of the procedure. 展开更多
关键词 partially Linear Varying Coefficient Model Mixed effect Penalized Estimating Equation
在线阅读 下载PDF
Effect of doxazosin on rabbit bladder compliance after partial bladder outlet obstruction
10
作者 皇甫雪军 《外科研究与新技术》 2011年第4期243-244,共2页
Objective To explore the effect of doxazosin on rabbit bladder compliance after partial bladder outlet ob- struction. Methods A total of 40 male New Zealand white rabbits were randomized into 4 groups,with 10 rabbits ... Objective To explore the effect of doxazosin on rabbit bladder compliance after partial bladder outlet ob- struction. Methods A total of 40 male New Zealand white rabbits were randomized into 4 groups,with 10 rabbits in each group. Partial bladder outlet 展开更多
关键词 effect of doxazosin on rabbit bladder compliance after partial bladder outlet obstruction der
暂未订购
Open Partial Nephrectomy: One Night Length of Stay Is Safe and Cost Effective
11
作者 Mohit Sirohi Kyrollis Attalla +1 位作者 Harris M. Nagler Erik T. Goluboff 《Open Journal of Urology》 2016年第9期139-146,共9页
Objective: To review our open partial nephrectomy (OPN) experience and compare to known robotic partial nephrectomy (RPN) data to determine whether length of stay (LOS) and morbidity are significant drivers in the sur... Objective: To review our open partial nephrectomy (OPN) experience and compare to known robotic partial nephrectomy (RPN) data to determine whether length of stay (LOS) and morbidity are significant drivers in the surgical approach employed for partial nephrectomy. Methods: We reviewed our OPN experience during the last 3 years examining age, tumor size, LOS, pathology, blood loss, complications, recurences, and deaths. Results: Seventy-five patients underwent OPN during this period. Mean age was 59 years, tumor size 2.8 cm, percent malignant 75%, estimated blood loss 350 cc. With a median follow-up of 18 months, there was one urinoma managed by drain-age, one pseudo aneurysm that required embolization and one pulmonary embolism that required anticoagulation. There were no readmissions, no tumor recurences, and no deaths. Our major complication rate was 4% as compared to other trials that re-ported major complication rates between 1% - 9% for RPN and between 3% - 24% for OPN. In the first half of the experience (n = 37), median LOS was 57 hours. Using a pathway encouraging early ambulation and smaller incisions in the second half of the experience (n = 38), median LOS was 35 hours. This is much shorter than reported RPN LOS of 62 - 67 hours and OPN LOS of 108 - 142 hours. Conclusion: OPN can be performed safely and effectively with one night hospital stay. This provides a more cost-effective approach to partial nephrectomy with similar or better complication rates and calls into question the main value drivers of RPN. 展开更多
关键词 Cost effective Length of Stay Open partial Nephrectomy Robotic partial Nephrectomy
暂未订购
Configuration model of partial repairable spares under batch ordering policy based on inventory state 被引量:21
12
作者 Ruan Minzhi Luo Yi Li Hua 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2014年第3期558-567,共10页
Rational planning of spares configuration project is an effective approach to improve equipment availability as well as reduce life cycle cost (LCC). With an analysis of various impacts on support system, the spares... Rational planning of spares configuration project is an effective approach to improve equipment availability as well as reduce life cycle cost (LCC). With an analysis of various impacts on support system, the spares demand rate forecast model is constructed. According to systemic analysis method, spares support effectiveness evaluation indicators system is built, and then, initial spares configuration and optimization method is researched. To the issue of discarding and con-sumption for incomplete repairable items, its expected backorders function is approximated by Laplace demand distribution. Combining the (s-1, s) and (R, Q) inventory policy, the spares resup-ply model is established under the batch ordering policy based on inventory state, and the optimi-zation analysis flow for spares configuration is proposed. Through application on shipborne equipment spares configuration, the given scenarios are analyzed under two constraint targets:one is the support effectiveness, and the other is the spares cost. Analysis reveals that the result is consistent with practical regulation;therefore, the model's correctness, method's validity as well as optimization project's rationality are proved to a certain extent. 展开更多
关键词 Batch ordering Inventory state Operations research partial repairable spares Support effectiveness evaluation
原文传递
A new structure and its analytical model for the vertical interface electric field of a partial-SOI high voltage device 被引量:2
13
作者 胡盛东 张波 +1 位作者 李肇基 罗小蓉 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第3期496-502,共7页
A new partial-SOI (PSOI) high voltage device structure called a CI PSOI (charge island PSOI) is proposed for the first time in this paper. The device is characterized by a charge island layer on the interface of t... A new partial-SOI (PSOI) high voltage device structure called a CI PSOI (charge island PSOI) is proposed for the first time in this paper. The device is characterized by a charge island layer on the interface of the top silicon layer and the dielectric buried layer in which a series of equidistant high concentration n+-regions is inserted. Inversion holes resulting from the vertical electric field are located in the spacing between two neighbouring n+-regions on the interface by the force with ionized donors in the undepleted n+-regions, and therefore effectively enhance the electric field of the dielectric buried layer (Ei) and increase the breakdown voltage (BV), thereby alleviating the self-heating effect (SHE) by the silicon window under the source. An analytical model of the vertical interface electric field for the CI PSOI is presented and the analytical results are in good agreement with the 2D simulation results. The BV and El of the CI PSOI LDMOS increase to 631 V and 584 V/μm from 246 V and 85.8 V/μm for the conventional PSOI with a lower SHE, respectively. The effects of the structure parameters on the device characteristics are analysed for the proposed device in detail. 展开更多
关键词 interface charges breakdown voltage partial-SOI self-heating effect
原文传递
EFFECTIVE DYNAMICS OF A COUPLED MICROSCOPIC-MACROSCOPIC STOCHASTIC SYSTEM 被引量:2
14
作者 任剑 付红波 +1 位作者 曹道民 段金桥 《Acta Mathematica Scientia》 SCIE CSCD 2010年第6期2064-2076,共13页
A conceptual model for microscopic-macroscopic slow-fast stochastic systems is considered. A dynamical reduction procedure is presented in order to extract effective dynamics for this kind of systems. Under appropriat... A conceptual model for microscopic-macroscopic slow-fast stochastic systems is considered. A dynamical reduction procedure is presented in order to extract effective dynamics for this kind of systems. Under appropriate assumptions, the effective system is shown to approximate the original system, in the sense of a probabilistic convergence. 展开更多
关键词 microscopic-macroscopic system stochastic partial differential equations averaging principle effective dynamics slow-fast scales
在线阅读 下载PDF
Isotope effect in collision between helium atom and hydrogen bromide molecule
15
作者 余春日 程新路 杨向东 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第9期3322-3328,共7页
The anisotropic potential developed in our previous research and the close-coupling method are applied to the HBr-3He (4He, 5He, 6He, 7He) system, and the partial cross sections (PCSs) at the incident energy of 60... The anisotropic potential developed in our previous research and the close-coupling method are applied to the HBr-3He (4He, 5He, 6He, 7He) system, and the partial cross sections (PCSs) at the incident energy of 60meV are calculated. Based on the calculations, the influences of the isotope helium atom on PCSs are discussed in detail. The results show that the excitation PCSs converge faster than the elastic PCSs for the collision energy and the systems considered here. Also the excitation PCSs converge more rapidly for the high-excited states. The tail effect is present only in elastic scattering and low-exclted states but not in high-excited states. With the increase of reduced mass of the collision system, the converging speed of the elastic and excitation PCSs slows down, and the tail effect goes up. 展开更多
关键词 isotope effect partial cross section anisotropic potential HBr-He collision
原文传递
Numerical Solution for Variable Accelerated Flow Subject to Slip Effect
16
作者 H. A. Ashi 《Open Journal of Fluid Dynamics》 2017年第4期485-500,共16页
In this paper, we examine the unsteady magneto hydrodynamic (MHD) flow generated by a disc that is making non-coaxial rotations with a third grade fluid at infinity and moving with a variable acceleration. The fluid i... In this paper, we examine the unsteady magneto hydrodynamic (MHD) flow generated by a disc that is making non-coaxial rotations with a third grade fluid at infinity and moving with a variable acceleration. The fluid is assumed to satisfy slip boundary condition on the disc. The governing equations are three dimensional and highly non-linear in nature. The assumed slip boundary condition is non-linear as well. The governing equations are transformed to a nonlinear boundary value problem which is solved numerically. Comparison of this generalized problem with uniformly accelerated disk satisfying no slip condition is made. Variations of the characterizing dimensionless parameters such as slip parameter λ, acceleration parameter c, unsteady parameter τ, third grade parameter β, suction parameter S, and magnetic parameter N on the flow field are discussed and analyzed graphically. 展开更多
关键词 Non-Newtonian Fluid partial SLIP effect VARIABLE ACCELERATED DISK Non-Coaxial Rotation Numerical Solution
在线阅读 下载PDF
PARTIAL REGULARITY FOR THE NAVIER-STOKES-FOURIER SYSTEM 被引量:2
17
作者 Luisa Consiglieri 《Acta Mathematica Scientia》 SCIE CSCD 2011年第5期1653-1670,共18页
This paper addresses a nonstationary flow of heat-conductive incompressible Newtonian fluid with temperature-dependent viscosity coupled with linear heat transfer with advection and a viscous heat source term, under N... This paper addresses a nonstationary flow of heat-conductive incompressible Newtonian fluid with temperature-dependent viscosity coupled with linear heat transfer with advection and a viscous heat source term, under Navier/Dirichlet boundary conditions. The partial regularity for the velocity of the fluid is proved for each proper weak solution, that is, for such weak solutions which satisfy some local energy estimates in a similar way to the suitable weak solutions of the Navier-Stokes system. Finally, we study the nature of the set of points in space and time upon which proper weak solutions could be singular. 展开更多
关键词 partial regularity Navier-Stokes-Fourier system Joule effect suitable weak solutions
在线阅读 下载PDF
ROBUST ESTIMATION IN PARTIAL LINEAR MIXED MODEL FOR LONGITUDINAL DATA
18
作者 秦国友 朱仲义 《Acta Mathematica Scientia》 SCIE CSCD 2008年第2期333-347,共15页
In this article, robust generalized estimating equation for the analysis of partial linear mixed model for longitudinal data is used. The authors approximate the nonparametric function by a regression spline. Under so... In this article, robust generalized estimating equation for the analysis of partial linear mixed model for longitudinal data is used. The authors approximate the nonparametric function by a regression spline. Under some regular conditions, the asymptotic properties of the estimators are obtained. To avoid the computation of high-dimensional integral, a robust Monte Carlo Newton-Raphson algorithm is used. Some simulations are carried out to study the performance of the proposed robust estimators. In addition, the authors also study the robustness and the efficiency of the proposed estimators by simulation. Finally, two real longitudinal data sets are analyzed. 展开更多
关键词 Generalized estimating equation longitudinal data metropolis algorithm mixed effect partial linear model ROBUSTNESS
在线阅读 下载PDF
Shape-memory effect in Co-Ni single crystal
19
作者 周伟敏 刘岩 +1 位作者 张少宗 江伯鸿 《中国有色金属学会会刊:英文版》 CSCD 2004年第2期223-226,共4页
The thermal shape-memory effect at room temperature for Co-32%Ni(mass fraction) magnetic shape memory alloy of single crystal was presented. When compressing the sample along the direction at room temperature, strain ... The thermal shape-memory effect at room temperature for Co-32%Ni(mass fraction) magnetic shape memory alloy of single crystal was presented. When compressing the sample along the direction at room temperature, strain can be recovered to some extent during later heating and the recovery rate varies with the pre-strain. But no obvious recoverable strain can be obtained along other crystal directions. For the thermal-mechanical training of the sample along , the recovery strain decreases obviously during the second round of compress and nearly no recovery happens after the third round of compress. A possible mechanism based on reversible motions of Shockley partial dislocations was proposed. 展开更多
关键词 钴基合金 形状记忆合金 形状记忆效应 Co-Ni单晶 DSC SME
在线阅读 下载PDF
The direct ionization processes in the collisions of partially stripped carbon and oxygen ions with helium atoms at low-to-intermediate energies
20
作者 周春林 邵剑雄 +2 位作者 陈熙萌 孙光智 邹贤容 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第11期4193-4198,共6页
The values of direct double- to-single ionization ratio R of helium atoms induced by C^q+, O^q+ (q = 1 -4) ions at incident energies from 0.2 to 8.5MeV are measured. Based on the existing model (Shao J X, Chen X ... The values of direct double- to-single ionization ratio R of helium atoms induced by C^q+, O^q+ (q = 1 -4) ions at incident energies from 0.2 to 8.5MeV are measured. Based on the existing model (Shao J X, Chen X M and Ding B W 2007 Phys. Rev. A 75 012701) the effective charge of the projectile is introduced to theoretically estimate the value of R for the partially stripped ions impacting on helium atoms. The results calculated from our "effective charge" model are in good agreement with the experimental data, and the dependence of the effective charge on the ionization energy of the projectile is also discussed qualitatively. 展开更多
关键词 effective charge partially stripped ions cross-section ratio direct ionization
原文传递
上一页 1 2 41 下一页 到第
使用帮助 返回顶部