In this paper, the robustness of the orbit structure is investigated for a partially hyperbolic endomorphism f on a compact manifold M. It is first proved that the dynamical structure of its orbit space (the inverse ...In this paper, the robustness of the orbit structure is investigated for a partially hyperbolic endomorphism f on a compact manifold M. It is first proved that the dynamical structure of its orbit space (the inverse limit space) M^f of f is topologically quasi-stable under C^0-small perturbations in the following sense: For any covering endomorphism g C^0-close to f, there is a continuous map φ from M^9 to Π-∞^∞ M such that for any {yi}i∈z∈φ(M^9), yi+1 and f(yi) differ only by a motion along the center direction. It is then proved that f has quasi-shadowing property in the following sense: For any pseudo-orbit {xi}i∈z, there is a sequence of points {yi}i∈z tracing it, in which yi+1 is obtained from f(yi) by a motion along the center direction.展开更多
In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also r...In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 + 0.1 mm (range: 0.77-1.05 mm), 0.77 + 0.11 mm (range: 0.60-0.94 mm), 0.70 + 0.08 mm (range: 0.62-0.80 ram), and 0.68 _+ 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the intraocular pressure before, during and after the intra-abdominal pressure elevation. These results verified that the increased intra-abdominal pressure widens the orbital subarachnoid space in this acute trial, but does not alter the intraocular pressure, indicating that intraocular pressure is not affected by rapid increased in- tra-abdominal pressure. This study was registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-ONRC-14004947).展开更多
AIM: To investigate the diffusion changes in both the optic nerve and optic tract in orbital space-occupying lesion patients with decreased visual acuity, and its clinical significance using probabilistic diffusion tr...AIM: To investigate the diffusion changes in both the optic nerve and optic tract in orbital space-occupying lesion patients with decreased visual acuity, and its clinical significance using probabilistic diffusion tractography(PDT). METHODS: Twenty patients with orbital space-occupying lesions and 25 age-and gender-matched healthy persons were included. All patients and controls underwent routine orbital magnetic resonance imaging and diffusion tensor imaging(DTI), using a 3.0 T magnetic resonance scanner(Trio Tim Siemens). After the image data were preprocessed, each DTI parameters of the optic nerve and optic tract was obtained by PDT, including fractional anisotropy(FA), mean diffusivity(MD), axial diffusivity(AD) and radial diffusivity(RD). The asymmetry index(AI) of each parameter was calculated. Compared the parameters of the affected side optic nerve and ipsilateral optic tract with the contralateral side by paired sample t-test;compared AI of parameters of optic nerve and optic tract between the patient group and the control group by independent sample t-test. Patients were divided into threesubgroups according to the low vision grade standard of WHO, compared the FA and AI of FA between the three subgroups by single factor variance analysis. RESULTS: The affected side optic nerve presented significantly decreased FA, increased MD, AD, and RD values compared to the unaffected side(P<0.05). The AI of FA, MD, AD, and RD of optic nerve in the patients was significantly higher than that of the controls(P<0.05). The comparison results of the optic tract showed that there was no significant difference between the patient group and control group in terms of the bilateral optic tracts in patients(P>0.05). The AIs of the FA value of the optic nerve in the eyesight <0.1 subgroup was significantly higher than that in the other groups(P<0.05). CONCLUSION: FA, MD, AD, and RD of the affected side optic nerve of the orbital space-occupying lesions have significantly changed, the FA value is the most sensitive. The PDT could be a useful tool to provide valid quantitative markers of optic nerve injuries and evaluate the severity of orbital diseases, which other examinations cannot be acquired.展开更多
This paper gives a brief introduction of YingHuo-1(YH-1),a Chinese Martian Space Environment Exploration Orbiter.YH-1 is a micro-satellite developed by Chinese Aerospace Industry,and will be launched together with Rus...This paper gives a brief introduction of YingHuo-1(YH-1),a Chinese Martian Space Environment Exploration Orbiter.YH-1 is a micro-satellite developed by Chinese Aerospace Industry,and will be launched together with Russian spacecraft,Phobos-Grunt,to orbit Mars in September,2009.Four payloads are selected for the mission,plasma package,including of electron analyzer,ion energy and mass analyzer;sat-sat occultation receiver;flux-gate magnetometer;and optical monitor.YH-1 mission focus on the investigation of the characteristics and its evolution of the Martian space Environment,and identifying major plasma processes,which provide channels for Martian volatiles escaping.展开更多
Objective:To analyze the clinical features,histopathologic classification and frequencies of various types of recurrent orbital space-occupying lesions.Methods:A retrospective study was carried out in 253 consecutiv...Objective:To analyze the clinical features,histopathologic classification and frequencies of various types of recurrent orbital space-occupying lesions.Methods:A retrospective study was carried out in 253 consecutive patients with recurrent orbital spaceoccupying lesions treated by surgical excision in the Institute of Orbital Diseases,the General Hospital of the Armed Police Force from January 2009 to December 2010.Results:The patients included 123 males and 130 females aged 2 to 78 years(mean,36.2 years),and the last recurrence interval after operation ranged from 1 month to 40 years(median,4.75 years).Of all the cases,159(62.8%),65(25.7%),20(7.9%),8(3.2%) and 1(0.4%) had previously experienced once,twice,three,four and six times of surgeries,respectively.Among them,29(11.5%) cases had recurred 3 times or over,and 37(14.6%) cases got recurrence in 10 or more years postoperatively.Most of the patients with local recurrence presented with various clinical manifestations,while 31(12.3%) cases were symptom-free.Two hundred and thirty-one(91.3%) cases underwent surgical removal of the recurrent orbital lesions,and another 22(8.7%) cases had to receive the exenteration of orbit.Categories of these recurrent orbital lesions after operation were as follows:lacrimal gland tumors,65(25.7%) cases;vasogenic diseases,54(21.3%) cases;neurogenic tumors,42(16.6%) cases;secondary tumors,24(9.5%) cases;orbital inflammation,21(8.3%) cases;myogenic tumors,14(5.5%) cases;fibrous and adipose tumors,12(4.7%) cases;lympho-hematopoietic tumors,7(2.8%) cases;bone or cartilage tumors,7(2.8%) cases;orbital cysts,6(2.4%) cases;and indefinitely differentiated tumor,1(0.4%) case.The 10 top histopathologic diagnoses were lacrimal gland pleomorphic adenoma,hemangiolymphangioma,lacrimal gland adenoid cystic carcinoma,meningioma,inflammatory pseudotumor,neurofibroma,sebaceous gland carcinoma,vascular malformation,rhabdomyosarcoma and hemangioma.Conclusions:The variety of recurrent orbital lesions after operation includes mainly of tumors except for vascular malformation and orbital inflammatory lesions.The lacrimal gland epithelial tumor is most prone to relapse after resection,and early and longer-term postoperative follow-up is needed.展开更多
Irregular phase-space orbits of the electrons are harmful to the electron-beam transport quality and hence deteriorate the performance of a free-electron laser (FEL). In previous literature, it was demonstrated that...Irregular phase-space orbits of the electrons are harmful to the electron-beam transport quality and hence deteriorate the performance of a free-electron laser (FEL). In previous literature, it was demonstrated that the irregularity of the electron phase-space orbits could be caused in several ways, such as varying the wiggler amplitude and inducing sidebands. Based on a Hamiltonian model with a set of self-consistent differential equations, it is shown in this paper that the electron- beam normalized plasma frequency functions not only couple the electron motion with the FEL wave, which results in the evolution of the FEL wave field and a possible power saturation at a large beam current, but also cause the irregularity of the electron phase-space orbits when the normalized plasma frequency has a sufficiently large value, even if the initial energy of the electron is equal to the synchronous energy or the FEL wave does not reach power saturation.展开更多
The light's orbital angular momentum (OAM) is a consequence of the spiral flow of the electromagnetic energy. In this paper, an analysis of light beams with OAM used for free space optics (FSO) is conducted. The ...The light's orbital angular momentum (OAM) is a consequence of the spiral flow of the electromagnetic energy. In this paper, an analysis of light beams with OAM used for free space optics (FSO) is conducted. The basic description and conception of light's OAM are reviewed. Both encoding information into OAM states of single light beam and encoding information into spatial structure of the mixed optical vortex with OAM are discussed, and feasibility to improve the FSO's performance of security and obstruction of line of sight is examined.展开更多
北斗三号全球卫星导航系统(BDS-3)于2020年7月31日正式开通,其空间段服务能力是决定系统整体性能表现的重要因素.本文对广播轨道、广播钟差、空间信号测距误差、广播电离层精度的评估计算方法进行了分析,分别以GFZ(German Research Cent...北斗三号全球卫星导航系统(BDS-3)于2020年7月31日正式开通,其空间段服务能力是决定系统整体性能表现的重要因素.本文对广播轨道、广播钟差、空间信号测距误差、广播电离层精度的评估计算方法进行了分析,分别以GFZ(German Research Centre for Geosciences)和iGMAS(International GNSS Monitoring and Assessment System)的最终产品为参考基准,对系统从2020年正式开通至2025年的变化情况进行了评估分析.研究表明, BDS-3广播轨道精度呈现明显的卫星类型相关性, MEO卫星高于IGSO卫星,与GFZ产品和iGMAS产品相比,径向、切向、法向95%的RMS值均得到不同程度地改善;广播钟差误差与SISRE(Signal-InSpace Range Error) 95%的RMS值则提升了分米级的精度;电离层模型误差方面,在评估周期内, Klobuchar模型的VTEC值分布范围相对较广,低VTEC区间BDGIM模型的频次分布更为集中;与CODE和iGMAS电离层产品相比,在太阳活动极小期的2020年BDGIM(Beidou Global Lonospheric Delay Correction Model)模型VTEC平均RMS值优于Klobuchar模型,而在太阳活动极大期的2025年两模型的VTEC平均RMS值均呈上升的趋势,且BDGIM模型的稳定性更强.展开更多
High-energy pulsed laser radiation may be the most feasible means to mitigate the threat of collision of a space station or other valuable space assets with orbital debris in the size range of 1–10 cm. Under laser ir...High-energy pulsed laser radiation may be the most feasible means to mitigate the threat of collision of a space station or other valuable space assets with orbital debris in the size range of 1–10 cm. Under laser irradiation, part of the debris material is ablated and provides an impulse to the debris particle. Proper direction of the impulse vector either deflects the object trajectory or forces the debris on a trajectory through the upper atmosphere, where it burns up. Most research concentrates on ground-based laser systems but pays little attention to space-based laser systems.There are drawbacks of a ground-based laser system in cleaning space debris. Therefore the placement of a laser system in space is proposed and investigated. Under assumed conditions,the elimination process of space debris is analyzed. Several factors such as laser repetition frequency, relative movement between the laser and debris, and inclination of debris particles which may exercise influence to the elimination effects are discussed. A project of a space-based laser system is proposed according to the numerical results of a computer study. The proposed laser system can eliminate debris of 1–10 cm and succeed in protecting a space station.展开更多
基金supported by the National Natural Science Foundation of China(No.11371120)the High-level Personnel for Institutions of Higher Learning in Hebei Province(No.GCC2014052)the Natural Science Foundation of Hebei Province(No.A2013205148)
文摘In this paper, the robustness of the orbit structure is investigated for a partially hyperbolic endomorphism f on a compact manifold M. It is first proved that the dynamical structure of its orbit space (the inverse limit space) M^f of f is topologically quasi-stable under C^0-small perturbations in the following sense: For any covering endomorphism g C^0-close to f, there is a continuous map φ from M^9 to Π-∞^∞ M such that for any {yi}i∈z∈φ(M^9), yi+1 and f(yi) differ only by a motion along the center direction. It is then proved that f has quasi-shadowing property in the following sense: For any pseudo-orbit {xi}i∈z, there is a sequence of points {yi}i∈z tracing it, in which yi+1 is obtained from f(yi) by a motion along the center direction.
文摘In accordance with the trans-lamina cribrosa pressure difference theory, decreasing the trans-lamina cribrosa pressure difference can re- lieve glaucomatous optic neuropathy. Increased intracranial pressure can also reduce optic nerve damage in glaucoma patients, and a safe, effective and noninvasive way to achieve this is by increasing the intra-abdominal pressure. The purpose of this study was to observe the changes in orbital subarachnoid space width and intraocular pressure at elevated intra-abdominal pressure. An inflatable abdominal belt was tied to each of 15 healthy volunteers, aged 22-30 years (12 females and 3 males), at the navel level, without applying pressure to the abdomen, before they laid in the magnetic resonance imaging machine. The baseline orbital subarachnoid space width around the optic nerve was measured by magnetic resonance imaging at 1, 3, 9, and 15 mm behind the globe. The abdominal belt was inflated to increase the pressure to 40 mmHg (1 mmHg = 0.133 kPa), then the orbital subarachnoid space width was measured every 10 minutes for 2 hours. After removal of the pressure, the measurement was repeated 10 and 20 minutes later. In a separate trial, the intraocular pressure was measured for all the subjects at the same time points, before, during and after elevated intra-abdominal pressure. Results showed that the baseline mean orbital subarachnoid space width was 0.88 + 0.1 mm (range: 0.77-1.05 mm), 0.77 + 0.11 mm (range: 0.60-0.94 mm), 0.70 + 0.08 mm (range: 0.62-0.80 ram), and 0.68 _+ 0.08 mm (range: 0.57-0.77 mm) at 1, 3, 9, and 15 mm behind the globe, respectively. During the elevated intra-abdominal pressure, the orbital subarachnoid space width increased from the baseline and dilation of the optic nerve sheath was significant at 1, 3 and 9 mm behind the globe. After decompression of the abdominal pressure, the orbital subarachnoid space width normalized and returned to the baseline value. There was no significant difference in the intraocular pressure before, during and after the intra-abdominal pressure elevation. These results verified that the increased intra-abdominal pressure widens the orbital subarachnoid space in this acute trial, but does not alter the intraocular pressure, indicating that intraocular pressure is not affected by rapid increased in- tra-abdominal pressure. This study was registered in the Chinese Clinical Trial Registry (registration number: ChiCTR-ONRC-14004947).
基金Supported by the National Natural Science Foundation of China (No.81471649)Beijing Municipal Science and Technology Commission (No. Z171100000117001)
文摘AIM: To investigate the diffusion changes in both the optic nerve and optic tract in orbital space-occupying lesion patients with decreased visual acuity, and its clinical significance using probabilistic diffusion tractography(PDT). METHODS: Twenty patients with orbital space-occupying lesions and 25 age-and gender-matched healthy persons were included. All patients and controls underwent routine orbital magnetic resonance imaging and diffusion tensor imaging(DTI), using a 3.0 T magnetic resonance scanner(Trio Tim Siemens). After the image data were preprocessed, each DTI parameters of the optic nerve and optic tract was obtained by PDT, including fractional anisotropy(FA), mean diffusivity(MD), axial diffusivity(AD) and radial diffusivity(RD). The asymmetry index(AI) of each parameter was calculated. Compared the parameters of the affected side optic nerve and ipsilateral optic tract with the contralateral side by paired sample t-test;compared AI of parameters of optic nerve and optic tract between the patient group and the control group by independent sample t-test. Patients were divided into threesubgroups according to the low vision grade standard of WHO, compared the FA and AI of FA between the three subgroups by single factor variance analysis. RESULTS: The affected side optic nerve presented significantly decreased FA, increased MD, AD, and RD values compared to the unaffected side(P<0.05). The AI of FA, MD, AD, and RD of optic nerve in the patients was significantly higher than that of the controls(P<0.05). The comparison results of the optic tract showed that there was no significant difference between the patient group and control group in terms of the bilateral optic tracts in patients(P>0.05). The AIs of the FA value of the optic nerve in the eyesight <0.1 subgroup was significantly higher than that in the other groups(P<0.05). CONCLUSION: FA, MD, AD, and RD of the affected side optic nerve of the orbital space-occupying lesions have significantly changed, the FA value is the most sensitive. The PDT could be a useful tool to provide valid quantitative markers of optic nerve injuries and evaluate the severity of orbital diseases, which other examinations cannot be acquired.
文摘This paper gives a brief introduction of YingHuo-1(YH-1),a Chinese Martian Space Environment Exploration Orbiter.YH-1 is a micro-satellite developed by Chinese Aerospace Industry,and will be launched together with Russian spacecraft,Phobos-Grunt,to orbit Mars in September,2009.Four payloads are selected for the mission,plasma package,including of electron analyzer,ion energy and mass analyzer;sat-sat occultation receiver;flux-gate magnetometer;and optical monitor.YH-1 mission focus on the investigation of the characteristics and its evolution of the Martian space Environment,and identifying major plasma processes,which provide channels for Martian volatiles escaping.
文摘Objective:To analyze the clinical features,histopathologic classification and frequencies of various types of recurrent orbital space-occupying lesions.Methods:A retrospective study was carried out in 253 consecutive patients with recurrent orbital spaceoccupying lesions treated by surgical excision in the Institute of Orbital Diseases,the General Hospital of the Armed Police Force from January 2009 to December 2010.Results:The patients included 123 males and 130 females aged 2 to 78 years(mean,36.2 years),and the last recurrence interval after operation ranged from 1 month to 40 years(median,4.75 years).Of all the cases,159(62.8%),65(25.7%),20(7.9%),8(3.2%) and 1(0.4%) had previously experienced once,twice,three,four and six times of surgeries,respectively.Among them,29(11.5%) cases had recurred 3 times or over,and 37(14.6%) cases got recurrence in 10 or more years postoperatively.Most of the patients with local recurrence presented with various clinical manifestations,while 31(12.3%) cases were symptom-free.Two hundred and thirty-one(91.3%) cases underwent surgical removal of the recurrent orbital lesions,and another 22(8.7%) cases had to receive the exenteration of orbit.Categories of these recurrent orbital lesions after operation were as follows:lacrimal gland tumors,65(25.7%) cases;vasogenic diseases,54(21.3%) cases;neurogenic tumors,42(16.6%) cases;secondary tumors,24(9.5%) cases;orbital inflammation,21(8.3%) cases;myogenic tumors,14(5.5%) cases;fibrous and adipose tumors,12(4.7%) cases;lympho-hematopoietic tumors,7(2.8%) cases;bone or cartilage tumors,7(2.8%) cases;orbital cysts,6(2.4%) cases;and indefinitely differentiated tumor,1(0.4%) case.The 10 top histopathologic diagnoses were lacrimal gland pleomorphic adenoma,hemangiolymphangioma,lacrimal gland adenoid cystic carcinoma,meningioma,inflammatory pseudotumor,neurofibroma,sebaceous gland carcinoma,vascular malformation,rhabdomyosarcoma and hemangioma.Conclusions:The variety of recurrent orbital lesions after operation includes mainly of tumors except for vascular malformation and orbital inflammatory lesions.The lacrimal gland epithelial tumor is most prone to relapse after resection,and early and longer-term postoperative follow-up is needed.
基金Project supported by the Science Foundation of Department of Education of Sichuan Province,China (Grant No.12233454)the Youth Foundation of Department of Education of Sichuan Province,China (Grant No.10ZB080)the Xihua University Foundation,China (Grant No.Z0913306)
文摘Irregular phase-space orbits of the electrons are harmful to the electron-beam transport quality and hence deteriorate the performance of a free-electron laser (FEL). In previous literature, it was demonstrated that the irregularity of the electron phase-space orbits could be caused in several ways, such as varying the wiggler amplitude and inducing sidebands. Based on a Hamiltonian model with a set of self-consistent differential equations, it is shown in this paper that the electron- beam normalized plasma frequency functions not only couple the electron motion with the FEL wave, which results in the evolution of the FEL wave field and a possible power saturation at a large beam current, but also cause the irregularity of the electron phase-space orbits when the normalized plasma frequency has a sufficiently large value, even if the initial energy of the electron is equal to the synchronous energy or the FEL wave does not reach power saturation.
文摘The light's orbital angular momentum (OAM) is a consequence of the spiral flow of the electromagnetic energy. In this paper, an analysis of light beams with OAM used for free space optics (FSO) is conducted. The basic description and conception of light's OAM are reviewed. Both encoding information into OAM states of single light beam and encoding information into spatial structure of the mixed optical vortex with OAM are discussed, and feasibility to improve the FSO's performance of security and obstruction of line of sight is examined.
文摘北斗三号全球卫星导航系统(BDS-3)于2020年7月31日正式开通,其空间段服务能力是决定系统整体性能表现的重要因素.本文对广播轨道、广播钟差、空间信号测距误差、广播电离层精度的评估计算方法进行了分析,分别以GFZ(German Research Centre for Geosciences)和iGMAS(International GNSS Monitoring and Assessment System)的最终产品为参考基准,对系统从2020年正式开通至2025年的变化情况进行了评估分析.研究表明, BDS-3广播轨道精度呈现明显的卫星类型相关性, MEO卫星高于IGSO卫星,与GFZ产品和iGMAS产品相比,径向、切向、法向95%的RMS值均得到不同程度地改善;广播钟差误差与SISRE(Signal-InSpace Range Error) 95%的RMS值则提升了分米级的精度;电离层模型误差方面,在评估周期内, Klobuchar模型的VTEC值分布范围相对较广,低VTEC区间BDGIM模型的频次分布更为集中;与CODE和iGMAS电离层产品相比,在太阳活动极小期的2020年BDGIM(Beidou Global Lonospheric Delay Correction Model)模型VTEC平均RMS值优于Klobuchar模型,而在太阳活动极大期的2025年两模型的VTEC平均RMS值均呈上升的趋势,且BDGIM模型的稳定性更强.
基金supported by the National Natural Science Foundation of China(No:11102234)Provincial Level Project of China
文摘High-energy pulsed laser radiation may be the most feasible means to mitigate the threat of collision of a space station or other valuable space assets with orbital debris in the size range of 1–10 cm. Under laser irradiation, part of the debris material is ablated and provides an impulse to the debris particle. Proper direction of the impulse vector either deflects the object trajectory or forces the debris on a trajectory through the upper atmosphere, where it burns up. Most research concentrates on ground-based laser systems but pays little attention to space-based laser systems.There are drawbacks of a ground-based laser system in cleaning space debris. Therefore the placement of a laser system in space is proposed and investigated. Under assumed conditions,the elimination process of space debris is analyzed. Several factors such as laser repetition frequency, relative movement between the laser and debris, and inclination of debris particles which may exercise influence to the elimination effects are discussed. A project of a space-based laser system is proposed according to the numerical results of a computer study. The proposed laser system can eliminate debris of 1–10 cm and succeed in protecting a space station.