The phenomena of molecular adsorption in the nanometer are significant to the research of biological and medical materials,bio-medical engineering and other fields.As a high-resolution surface analysis technique,Scann...The phenomena of molecular adsorption in the nanometer are significant to the research of biological and medical materials,bio-medical engineering and other fields.As a high-resolution surface analysis technique,Scanning tunneling microscope(STM)has the potential to detect the adsorption of the protein in the aqueous environment,but the image analysis and the dynamic trajectory of the adsorption is still a problem.Being developed rapidly in recent years,molecular simulation technology provides an effective method to study the static system and dynamic process.展开更多
In this study, salting-out assisted liquid-liquid extraction combined with high performance liquid chromatography diode array detector (SALLE-HPLC-DAD) method was developed and validated for simultaneous analysis of c...In this study, salting-out assisted liquid-liquid extraction combined with high performance liquid chromatography diode array detector (SALLE-HPLC-DAD) method was developed and validated for simultaneous analysis of carbaryl, atrazine, propazine, chlorothalonil, dimethametryn and terbutryn in environmental water samples. Parameters affecting the extraction efficiency such as type and volume of extraction solvent, sample volume, salt type and amount, centrifugation speed and time, and sample pH were optimized. Under the optimum extraction conditions the method was linear over the range of 10 - 100 μg/L (carbaryl), 8 - 100 μg/L (atarzine), 7 - 100 μg/L (propazine) and 9 - 100 μg/L (chlorothalonil, terbutryn and dimethametryn) with correlation coefficients (R2) between 0.99 and 0.999. Limits of detection and quantification ranged from 2.0 to 2.8 μg/L and 6.7 to 9.5 μg/L, respectively. The extraction recoveries obtained for ground, lake and river waters were in a range of 75.5% to 106.6%, with the intra-day and inter-day relative standard deviation lower than 3.4% for all the target analytes. All of the target analytes were not detected in these samples. Therefore, the proposed SALLE-HPLC-DAD method is simple, rapid, cheap and environmentally friendly for the determination of the aforementioned herbicides, insecticide and fungicide residues in environmental water samples.展开更多
A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methyl...A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH) was used as a chelating agent, and chloroform and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of cobalt and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, a preconcentration factor of 8 was reached. The detection limit for cobalt was 12.4 ng?mL–1, and the relative standard deviation (RSD) was 3.42% (n = 7, c = 100 ng?mL–1). The method was successfully applied to the determination of cobalt in food, environmental and water samples.展开更多
A method for determination of 226Ra and 228Ra in environmental samples using the α-β coincidence liquid scintillation counting (LSC) has been developed. Radium were preconcentrated from environmental samples by copr...A method for determination of 226Ra and 228Ra in environmental samples using the α-β coincidence liquid scintillation counting (LSC) has been developed. Radium were preconcentrated from environmental samples by coprecipitation with BaSO4, then purified from others radionuclide interferences using the cation column exchange (Bio-Rad AG 50 W-X4 resin with 200-400 mesh size and H+ form) and operating in warm temperature which is between 70-80oC. Then, the Ba(Ra)SO4 precipitate was filtered through the Millipore filter paper, dried and weighed to calculate chemical yield. The activity concentration of radium isotopes in mixture of liquid scintillation cocktails were measured using LSC after being stored for over 21 days to allow the growth of the progeny nuclides. The method has been validated with a certi-fied reference material supplied by the International Atomic Energy Agency and reliable results were obtained. The radiochemical yields for radium were 59% - 90% and recovery was 97% and 80% for 226Ra and 228Ra, respectively. Sixteen seawater and fish flesh samples collected in Kapar coastal water have been analyzed with the developed method. The obtained radium activity concentrations in seawater were in the range of 02.08 ± 0.82 mBq/L to 3.69 ± 1.29 mBq/L for 226Ra and 6.01 ± 3.05 mBq/L to 17.07 ± 6.62 mBq/L for 228Ra. Meanwhile, the activity concentrations of 226Ra and 228Ra in fish flesh were in the range of 11.82 ± 5.23 – 16.53 ± 6.53 Bq/kg dry wt. and 43.52 ± 16.34 – 53.57 ± 19.86 Bq/kg dry wt., respectively.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
A large-scale high altitude environment simulation test cabin was developed to accurately control temperatures and pressures encountered at high altitudes. The system was developed to provide slope-tracking dynamic co...A large-scale high altitude environment simulation test cabin was developed to accurately control temperatures and pressures encountered at high altitudes. The system was developed to provide slope-tracking dynamic control of the temperature–pressure two-parameter and overcome the control difficulties inherent to a large inertia lag link with a complex control system which is composed of turbine refrigeration device, vacuum device and liquid nitrogen cooling device. The system includes multi-parameter decoupling of the cabin itself to avoid equipment damage of air refrigeration turbine caused by improper operation. Based on analysis of the dynamic characteristics and modeling for variations in temperature, pressure and rotation speed, an intelligent controller was implemented that includes decoupling and fuzzy arithmetic combined with an expert PID controller to control test parameters by decoupling and slope tracking control strategy. The control system employed centralized management in an open industrial ethernet architecture with an industrial computer at the core. The simulation and field debugging and running results show that this method can solve the problems of a poor anti-interference performance typical for a conventional PID and overshooting that can readily damage equipment. The steady-state characteristics meet the system requirements.展开更多
To study the genotoxicity effect of environmental tobacco side-stream smokes (ETSS) on oxidative DNA damage and its molecular mechanism. Methods DNA adduct 8-hydroxydeoxyguanosine (8-OHdG) was used ...To study the genotoxicity effect of environmental tobacco side-stream smokes (ETSS) on oxidative DNA damage and its molecular mechanism. Methods DNA adduct 8-hydroxydeoxyguanosine (8-OHdG) was used as a biomarker of oxidative DNA damage. The level of 8-OHdG in DNA exposed to ETSS was detected by high performance liquid chromatography with electrochemical detection. Organic and inorganic components in ETSS were analyzed by gas chromatography-mass spectrum and atomic absorption spectrum respectively. Results Particle matters (PMs) and volatile organic compounds (VOCs) in ETSS could directly induce oxidative DNA damage and formation of 8-OHdG. There were 123 and 84 kinds of organic components in PMs and VOCs respectively, and 7 kinds of inorganic components in ETSS. Some components, especially quinones and polyphenols in ETSS, could produce free radicals in vitro by auto-oxidation without any biological activity systems, and with the catalytic reaction of metals, the DNA adduct 8-OHdG was produced. Conclusion ETSS have biological oxidative effect on DNA in vitro and in vivo, and expressed direct genotoxicity. 8-OHdG is a valuable biomarker of oxidative DNA damage.展开更多
文摘The phenomena of molecular adsorption in the nanometer are significant to the research of biological and medical materials,bio-medical engineering and other fields.As a high-resolution surface analysis technique,Scanning tunneling microscope(STM)has the potential to detect the adsorption of the protein in the aqueous environment,but the image analysis and the dynamic trajectory of the adsorption is still a problem.Being developed rapidly in recent years,molecular simulation technology provides an effective method to study the static system and dynamic process.
文摘In this study, salting-out assisted liquid-liquid extraction combined with high performance liquid chromatography diode array detector (SALLE-HPLC-DAD) method was developed and validated for simultaneous analysis of carbaryl, atrazine, propazine, chlorothalonil, dimethametryn and terbutryn in environmental water samples. Parameters affecting the extraction efficiency such as type and volume of extraction solvent, sample volume, salt type and amount, centrifugation speed and time, and sample pH were optimized. Under the optimum extraction conditions the method was linear over the range of 10 - 100 μg/L (carbaryl), 8 - 100 μg/L (atarzine), 7 - 100 μg/L (propazine) and 9 - 100 μg/L (chlorothalonil, terbutryn and dimethametryn) with correlation coefficients (R2) between 0.99 and 0.999. Limits of detection and quantification ranged from 2.0 to 2.8 μg/L and 6.7 to 9.5 μg/L, respectively. The extraction recoveries obtained for ground, lake and river waters were in a range of 75.5% to 106.6%, with the intra-day and inter-day relative standard deviation lower than 3.4% for all the target analytes. All of the target analytes were not detected in these samples. Therefore, the proposed SALLE-HPLC-DAD method is simple, rapid, cheap and environmentally friendly for the determination of the aforementioned herbicides, insecticide and fungicide residues in environmental water samples.
文摘A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH) was used as a chelating agent, and chloroform and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of cobalt and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, a preconcentration factor of 8 was reached. The detection limit for cobalt was 12.4 ng?mL–1, and the relative standard deviation (RSD) was 3.42% (n = 7, c = 100 ng?mL–1). The method was successfully applied to the determination of cobalt in food, environmental and water samples.
文摘A method for determination of 226Ra and 228Ra in environmental samples using the α-β coincidence liquid scintillation counting (LSC) has been developed. Radium were preconcentrated from environmental samples by coprecipitation with BaSO4, then purified from others radionuclide interferences using the cation column exchange (Bio-Rad AG 50 W-X4 resin with 200-400 mesh size and H+ form) and operating in warm temperature which is between 70-80oC. Then, the Ba(Ra)SO4 precipitate was filtered through the Millipore filter paper, dried and weighed to calculate chemical yield. The activity concentration of radium isotopes in mixture of liquid scintillation cocktails were measured using LSC after being stored for over 21 days to allow the growth of the progeny nuclides. The method has been validated with a certi-fied reference material supplied by the International Atomic Energy Agency and reliable results were obtained. The radiochemical yields for radium were 59% - 90% and recovery was 97% and 80% for 226Ra and 228Ra, respectively. Sixteen seawater and fish flesh samples collected in Kapar coastal water have been analyzed with the developed method. The obtained radium activity concentrations in seawater were in the range of 02.08 ± 0.82 mBq/L to 3.69 ± 1.29 mBq/L for 226Ra and 6.01 ± 3.05 mBq/L to 17.07 ± 6.62 mBq/L for 228Ra. Meanwhile, the activity concentrations of 226Ra and 228Ra in fish flesh were in the range of 11.82 ± 5.23 – 16.53 ± 6.53 Bq/kg dry wt. and 43.52 ± 16.34 – 53.57 ± 19.86 Bq/kg dry wt., respectively.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.
基金supported by the Aeronautical Science Foun-dation of China(No.2012XX51043)‘‘Fanzhou’’Youth Scientific Funds of China(No.20100504)
文摘A large-scale high altitude environment simulation test cabin was developed to accurately control temperatures and pressures encountered at high altitudes. The system was developed to provide slope-tracking dynamic control of the temperature–pressure two-parameter and overcome the control difficulties inherent to a large inertia lag link with a complex control system which is composed of turbine refrigeration device, vacuum device and liquid nitrogen cooling device. The system includes multi-parameter decoupling of the cabin itself to avoid equipment damage of air refrigeration turbine caused by improper operation. Based on analysis of the dynamic characteristics and modeling for variations in temperature, pressure and rotation speed, an intelligent controller was implemented that includes decoupling and fuzzy arithmetic combined with an expert PID controller to control test parameters by decoupling and slope tracking control strategy. The control system employed centralized management in an open industrial ethernet architecture with an industrial computer at the core. The simulation and field debugging and running results show that this method can solve the problems of a poor anti-interference performance typical for a conventional PID and overshooting that can readily damage equipment. The steady-state characteristics meet the system requirements.
基金The research was supported and financed by brainstorm project and public good fund from the Ministry of Science and TechnologyChina (2001BA704B01& 2001DIA10001).
文摘To study the genotoxicity effect of environmental tobacco side-stream smokes (ETSS) on oxidative DNA damage and its molecular mechanism. Methods DNA adduct 8-hydroxydeoxyguanosine (8-OHdG) was used as a biomarker of oxidative DNA damage. The level of 8-OHdG in DNA exposed to ETSS was detected by high performance liquid chromatography with electrochemical detection. Organic and inorganic components in ETSS were analyzed by gas chromatography-mass spectrum and atomic absorption spectrum respectively. Results Particle matters (PMs) and volatile organic compounds (VOCs) in ETSS could directly induce oxidative DNA damage and formation of 8-OHdG. There were 123 and 84 kinds of organic components in PMs and VOCs respectively, and 7 kinds of inorganic components in ETSS. Some components, especially quinones and polyphenols in ETSS, could produce free radicals in vitro by auto-oxidation without any biological activity systems, and with the catalytic reaction of metals, the DNA adduct 8-OHdG was produced. Conclusion ETSS have biological oxidative effect on DNA in vitro and in vivo, and expressed direct genotoxicity. 8-OHdG is a valuable biomarker of oxidative DNA damage.