BACKGROUND Conduction and rhythm abnormalities requiring permanent pacemakers(PPM)are short-term complications following transcatheter aortic valve replacement(TAVR),and their clinical outcomes remain conflicting.Pote...BACKGROUND Conduction and rhythm abnormalities requiring permanent pacemakers(PPM)are short-term complications following transcatheter aortic valve replacement(TAVR),and their clinical outcomes remain conflicting.Potential novel predictors of post-TAVR PPM,like QRS duration,QTc prolongation,and supraventricular arrhythmias,have been poorly studied.AIM To evaluate the effects of baseline nonspecific interventricular conduction delay and supraventricular arrhythmia on post-TAVR PPM requirement and determine the impact of PPM implantation on clinical outcomes.METHODS RESULTS Out of the 357 patients that met inclusion criteria,the mean age was 80 years,188(52.7%)were male,and 57(16%)had a PPM implantation.Baseline demographics,valve type,and cardiovascular risk factors were similar except for type II diabetes mellitus(DM),which was more prevalent in the PPM cohort(59.6%vs 40.7%;P=0.009).The PPM cohort had a significantly higher rate of pre-procedure right bundle branch block,prolonged QRS>120 ms,prolonged QTc>470 ms,and supraventricular arrhythmias.There was a consistently significant increase in the odds ratio(OR)of PPM implantation for every 20 ms increase in the QRS duration above 100 ms:QRS 101-120[OR:2.44;confidence intervals(CI):1.14-5.25;P=0.022],QRS 121-140(OR:3.25;CI:1.32-7.98;P=0.010),QRS 141-160(OR:6.98;CI:3.10-15.61;P<0.001).After model adjustment for baseline risk factors,the OR remained significant for type II DM(aOR:2.16;CI:1.18-3.94;P=0.012),QRS>120(aOR:2.18;CI:1.02-4.66;P=0.045)and marginally significant for supraventricular arrhythmias(aOR:1.82;CI:0.97-3.42;P=0.062).The PPM cohort had a higher adjusted OR of heart failure(HF)hospitalization(aOR:2.2;CI:1.1-4.3;P=0.022)and nonfatal myocardial infarction(MI)(aOR:3.9;CI:1.1-14;P=0.031)without any difference in mortality(aOR:1.1;CI:0.5-2.7;P=0.796)at one year.CONCLUSION Pre-TAVR type II DM and QRS duration>120,regardless of the presence of bundle branch blocks,are predictors of post-TAVR PPM.At 1-year post-TAVR,patients with PPM have higher odds of HF hospitalization and MI.展开更多
目的探讨前列腺素E1(prostaglandin E1,PGE1)在室间隔完整的大动脉转位(transposition of greatarteries with intact ventricular septum,TGA/IVS)新生患儿院间转运过程中的应用。方法回顾性分析34例TGA/IVS新生患儿在院间转运过程中P...目的探讨前列腺素E1(prostaglandin E1,PGE1)在室间隔完整的大动脉转位(transposition of greatarteries with intact ventricular septum,TGA/IVS)新生患儿院间转运过程中的应用。方法回顾性分析34例TGA/IVS新生患儿在院间转运过程中PGE1应用的临床资料。根据患儿动脉导管的开放状态,个性化应用PGE1,初始剂量10 ng.kg-1.min-1,密切监测患者生命体征及循环状态的同时,调整PGE1的用量。结果无患儿在转运过程中死亡。应用PGE1前,血氧饱和度为52%±12%;应用后,血氧饱和度为78%±11%。应用前、后血氧饱和度比较,差异有统计学意义(P<0.05)。转运完成后经超声心动图证实:34例TGA/IVS患儿的动脉导管均处于开放状态。10例患儿出现中、高发热(37.4℃~39.4℃),其他患儿未见发生明显PGE1使用并发症。结论对于TGA/IVS新生患儿,在接诊、转运的早期,及时应用PGE1可以有效地提高动脉血氧饱和度,改善术前内环境状态,稳定患者病情,为手术矫治赢得时间。展开更多
Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation patt...Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation pattern, which results in asynchronous ventricular contraction and relaxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class Ⅰ indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold: 0.87 V; mean P wave amplitude: 2.28 mV; mean ventricular pacing threshold: 0.53V; mean R wave amplitude: 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible.展开更多
文摘BACKGROUND Conduction and rhythm abnormalities requiring permanent pacemakers(PPM)are short-term complications following transcatheter aortic valve replacement(TAVR),and their clinical outcomes remain conflicting.Potential novel predictors of post-TAVR PPM,like QRS duration,QTc prolongation,and supraventricular arrhythmias,have been poorly studied.AIM To evaluate the effects of baseline nonspecific interventricular conduction delay and supraventricular arrhythmia on post-TAVR PPM requirement and determine the impact of PPM implantation on clinical outcomes.METHODS RESULTS Out of the 357 patients that met inclusion criteria,the mean age was 80 years,188(52.7%)were male,and 57(16%)had a PPM implantation.Baseline demographics,valve type,and cardiovascular risk factors were similar except for type II diabetes mellitus(DM),which was more prevalent in the PPM cohort(59.6%vs 40.7%;P=0.009).The PPM cohort had a significantly higher rate of pre-procedure right bundle branch block,prolonged QRS>120 ms,prolonged QTc>470 ms,and supraventricular arrhythmias.There was a consistently significant increase in the odds ratio(OR)of PPM implantation for every 20 ms increase in the QRS duration above 100 ms:QRS 101-120[OR:2.44;confidence intervals(CI):1.14-5.25;P=0.022],QRS 121-140(OR:3.25;CI:1.32-7.98;P=0.010),QRS 141-160(OR:6.98;CI:3.10-15.61;P<0.001).After model adjustment for baseline risk factors,the OR remained significant for type II DM(aOR:2.16;CI:1.18-3.94;P=0.012),QRS>120(aOR:2.18;CI:1.02-4.66;P=0.045)and marginally significant for supraventricular arrhythmias(aOR:1.82;CI:0.97-3.42;P=0.062).The PPM cohort had a higher adjusted OR of heart failure(HF)hospitalization(aOR:2.2;CI:1.1-4.3;P=0.022)and nonfatal myocardial infarction(MI)(aOR:3.9;CI:1.1-14;P=0.031)without any difference in mortality(aOR:1.1;CI:0.5-2.7;P=0.796)at one year.CONCLUSION Pre-TAVR type II DM and QRS duration>120,regardless of the presence of bundle branch blocks,are predictors of post-TAVR PPM.At 1-year post-TAVR,patients with PPM have higher odds of HF hospitalization and MI.
文摘目的探讨前列腺素E1(prostaglandin E1,PGE1)在室间隔完整的大动脉转位(transposition of greatarteries with intact ventricular septum,TGA/IVS)新生患儿院间转运过程中的应用。方法回顾性分析34例TGA/IVS新生患儿在院间转运过程中PGE1应用的临床资料。根据患儿动脉导管的开放状态,个性化应用PGE1,初始剂量10 ng.kg-1.min-1,密切监测患者生命体征及循环状态的同时,调整PGE1的用量。结果无患儿在转运过程中死亡。应用PGE1前,血氧饱和度为52%±12%;应用后,血氧饱和度为78%±11%。应用前、后血氧饱和度比较,差异有统计学意义(P<0.05)。转运完成后经超声心动图证实:34例TGA/IVS患儿的动脉导管均处于开放状态。10例患儿出现中、高发热(37.4℃~39.4℃),其他患儿未见发生明显PGE1使用并发症。结论对于TGA/IVS新生患儿,在接诊、转运的早期,及时应用PGE1可以有效地提高动脉血氧饱和度,改善术前内环境状态,稳定患者病情,为手术矫治赢得时间。
基金supported by a grant form a Program of Science and Technology Development of Hubei Province (2004AA304B09).
文摘Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation pattern, which results in asynchronous ventricular contraction and relaxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class Ⅰ indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold: 0.87 V; mean P wave amplitude: 2.28 mV; mean ventricular pacing threshold: 0.53V; mean R wave amplitude: 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible.