期刊文献+
共找到14,884篇文章
< 1 2 250 >
每页显示 20 50 100
Wavelet Transform-Based High-Definition Map Construction From a Panoramic Camera 被引量:1
1
作者 ZHUANG Hanyang ZHOU Xuejun +1 位作者 WANG Chunxiang QIAN Yuhan 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第5期569-576,共8页
High-definition(HD)maps are key components that provide rich topologic and semantic information for decision-making in vehicle autonomous driving systems.A complete ground orthophoto is usually used as the base image ... High-definition(HD)maps are key components that provide rich topologic and semantic information for decision-making in vehicle autonomous driving systems.A complete ground orthophoto is usually used as the base image to construct the HD map.The ground orthophoto is obtained through inverse perspective transformation and image mosaicing.During the image mosaicing,multiple consecutive orthophotos are stitched together using pose information and image registration.In this study,wavelet transform is introduced to the image mosaicing process to alleviate the information loss caused by image overlapping.In the orthophoto wavelet transform,high-frequency and low-frequency components are fused using different strategies to form a complete base image with clearer local details.Experimental results show that the accuracy of the orthophotos generated using this method is improved. 展开更多
关键词 high-definition(HD)map wavelet transform image registration PANORAMA
原文传递
Secure task offloading strategy optimization of UAV-aided outdoor mobile high-definition live streaming
2
作者 Ming YAN Yuxuan ZHANG +2 位作者 Chien Aun CHAN André F.GYGAX Chunguo LI 《Chinese Journal of Aeronautics》 2025年第10期201-215,共15页
Unmanned aerial vehicles(UAVs)bring more innovation and attraction to outdoor mobile high-definition(HD)live streaming with its unique perspective.Due to the heavy computational requirements of HD live broadcast tasks... Unmanned aerial vehicles(UAVs)bring more innovation and attraction to outdoor mobile high-definition(HD)live streaming with its unique perspective.Due to the heavy computational requirements of HD live broadcast tasks and the limited hardware performance of UAV equipment,how to reduce the system response delay and improve the energy efficiency of terminal equipment directly affects the secure broadcast of the system.Secure task offloading in this scenario is considered a promising solution and has received academic attention.In this paper,we simulate the UAV-aided outdoor mobile HD live streaming scenarios and optimize the relevant task offloading strategies.First,we design the total cost function of task offloading that jointly optimizes secure time latency and energy consumption.Additionally,we propose a collaborative computing model for multi-UAV task offloading.This model combines the idea of simulated annealing(SA)and introduces the compression factor to enhance the particle swarm optimization(PSO)to realize secure task offloading.The simulation results show that the proposed strategy has better performance in balancing network latency and energy consumption.Compared with the discrete teaching–learning-based optimization(DTLBO)and quantum PSO(QPSO)task offloading strategies,the fitness value of the proposed strategy is decreased by an average of 26.73%and 16.42%,respectively. 展开更多
关键词 Unmanned aerial vehicle(UAV) high-definition(HD)live streaming Secure task offloading Network energy consumption Particle swarm optimization(PSO)
原文传递
Optical design of wide-field and broadband light field camera for high-precision optical surface defect detection
3
作者 Chengchen Zhou Yukun Wang +7 位作者 Yue Ding Dacheng Wang Jiucheng Nie Jialong Li Zhixi Li Zheng Zhou Shuangshuang Zhang Xiaokun Wang 《Astronomical Techniques and Instruments》 2026年第1期64-74,共11页
To address the challenges of high-precision optical surface defect detection,we propose a novel design for a wide-field and broadband light field camera in this work.The proposed system can achieve a 50°field of ... To address the challenges of high-precision optical surface defect detection,we propose a novel design for a wide-field and broadband light field camera in this work.The proposed system can achieve a 50°field of view and operates at both visible and near-infrared wavelengths.Using the principles of light field imaging,the proposed design enables 3D reconstruction of optical surfaces,thus enabling vertical surface height measurements with enhanced accuracy.Using Zemax-based simulations,we evaluate the system’s modulation transfer function,its optical aberrations,and its tolerance to shape variations through Zernike coefficient adjustments.The results demonstrate that this camera can achieve the required spatial resolution while also maintaining high imaging quality and thus offers a promising solution for advanced optical surface defect inspection. 展开更多
关键词 Optical design Defect detection Wide-field camera Broadband light field camera
在线阅读 下载PDF
High-definition colonoscopy with i-Scan:Better diagnosis for small polyps and flat adenomas 被引量:12
4
作者 Pier Alberto Testoni Chiara Notaristefano +2 位作者 Cristian Vailati Milena Di Leo Edi Viale 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第37期5231-5239,共9页
AIM: To investigate if high-definition (HD) colonoscope with i-Scan gave a higher detection rate of mucosal le- sions vs standard white-light instruments. METHODS: Data were collected from the computer- ized datab... AIM: To investigate if high-definition (HD) colonoscope with i-Scan gave a higher detection rate of mucosal le- sions vs standard white-light instruments. METHODS: Data were collected from the computer- ized database of the endoscopy unit of our tertiary referral center. We retrospectively analyzed 1101 con- secutive colonoscopies that were performed over 1 year with standard white-light (n = 849) or HD+ with i-Scan (n = 252) instruments by four endoscopists, in an outpatient setting. Colonoscopy records included patients' main details and family history for colorectal cancer, indication for colonoscopy (screening, diagnos- tic or surveillance), type of instrument used (standard white-light or HD+ plus i-Scan), name of endoscopist and bowel preparation. Records for each procedure included whether the cecum was reached or not and the reason for failure, complications during or imme- diately after the procedure, and number, size, location and characteristics of the lesions. Polyps or protruding lesions were defined as sessile or pedunculated, and nonprotruding lesions were defined according to Paris classification. For each lesion, histological diagnosis was recorded. RESULTS: Eight hundred and forty-nine colonosco- pies were carried with the standard white-light video colonoscope and 252 with the HD+ plus i-Scan video colonoscope, The four endoscopists did 264, 300, 276 and 261 procedures, respectively; 21.6%, 24.0%, 21.7% and 24.1% of them with the HD+ plus i-Scan technique. There were no significant differences be- tween the four endoscopists in either the number of procedures done or the proportions of each imaging technique used. Both techniques detected one or more mucosal lesions in 522/1101 procedures (47.4%). The overall number of lesions recognized was 1266; 645 in the right colon and 621 in the left. A significantly higher number of colonoscopies recognized lesions in the HD+ plus i-Scan mode (171/252 = 67.9%) than with the standard white-light technique (408/849 = 48.1%) (P 〈 0.0001). HD+ with i-Scan colonoscopies identified more lesions than standard white-light imag- ing (459/252 and 807/849, P 〈 0.0001), in the right or left colon (mean :1: SD, 1.62±1.36 vs 1.33±0.73, P 〈 0.003 and 1.55±0.98 vs 1.17±0.93, P = 0.033), more lesions 〈 10 mm (P 〈 0.0001) or nonprotruding (P 〈 0.022), and flat polyps (P = 0.04). The cumulative mean number of lesions per procedure detected by the four endoscopists was significantly higher with HD+ with i-Scan than with standard white-light imaging (1.82 ± 2.89 vs 0.95± 1.35, P 〈 0.0001). CONCLUSION: HD imaging with i-Scan during the withdrawal phase of colonoscopy significantly increased the detection of colonic mucosal lesions, particularly small and nonprotruding polyps. 展开更多
关键词 COLONOSCOPY high-definition with i-Scancolonoscopy White-light colonoscopy Colonic polyps Nonprotruding lesions Adenoma detection rate With-drawal time Surface enhancement Contrast enhance-ment Tone enhancement
暂未订购
Standard-definition White-light,High-definition White-light versus Narrow-band Imaging Endoscopy for Detecting Colorectal Adenomas:A Multicenter Randomized Controlled Trial 被引量:1
5
作者 Chang-wei DUAN Hui-hong ZHAI +10 位作者 Hui XIE Xian-zong MA Dong-liang YU Lang YANG Xin WANG Yu-fen TANG Jie ZHANG Hui SU Jian-qiu SHENG Jun-feng XU Peng JIN 《Current Medical Science》 SCIE CAS 2024年第3期554-560,共7页
Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colore... Objective This study aimed to compare the performance of standard-definition white-light endoscopy(SD-WL),high-definition white-light endoscopy(HD-WL),and high-definition narrow-band imaging(HD-NBI)in detecting colorectal lesions in the Chinese population.Methods This was a multicenter,single-blind,randomized,controlled trial with a non-inferiority design.Patients undergoing endoscopy for physical examination,screening,and surveillance were enrolled from July 2017 to December 2020.The primary outcome measure was the adenoma detection rate(ADR),defined as the proportion of patients with at least one adenoma detected.The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression.Results Out of 653 eligible patients enrolled,data from 596 patients were analyzed.The ADRs were 34.5%in the SD-WL group,33.5%in the HD-WL group,and 37.5%in the HD-NBI group(P=0.72).The advanced neoplasm detection rates(ANDRs)in the three arms were 17.1%,15.5%,and 10.4%(P=0.17).No significant differences were found between the SD group and HD group regarding ADR or ANDR(ADR:34.5%vs.35.6%,P=0.79;ANDR:17.1%vs.13.0%,P=0.16,respectively).Similar results were observed between the HD-WL group and HD-NBI group(ADR:33.5%vs.37.7%,P=0.45;ANDR:15.5%vs.10.4%,P=0.18,respectively).In the univariate and multivariate logistic regression analyses,neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL(HD-WL:OR 0.91,P=0.69;HD-NBI:OR 1.15,P=0.80).Conclusion HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients.It can be concluded that HD-NBI or HD-WL is not superior to SD-WL,but more effective instruction may be needed to guide the selection of different endoscopic methods in the future.Our study’s conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources,especially advanced imaging technologies. 展开更多
关键词 standard-definition white-light endoscopy high-definition white-light endoscopy narrow-band imaging colonoscopy colorectal cancer screening adenoma detection rate
暂未订购
Optical diagnosis of colorectal polyps using high-definition i-scan: An educational experience
6
作者 Mariёlle WE Bouwens Rogier de Ridder +4 位作者 Ad AM Masclee Ann Driessen Robert G Riedl Bjorn Winkens Silvia Sanduleanu 《World Journal of Gastroenterology》 SCIE CAS 2013年第27期4334-4343,共10页
AIM:To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience. METHODS:We used a digital library of HD i-scan still ... AIM:To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience. METHODS:We used a digital library of HD i-scan still images, comprising twin pictures (surface enhancement and tone enhancement), collected at our university hospital. We defined endoscopic features of adenomatous and non-adenomatous polyps, according to the following parameters:color, surface pattern and vascular pattern. We familiarized the participating endoscopists on optical diagnosis of colorectal polyps using a 20-min didactic training session. All endoscopists were asked to evaluate an image set of 50 colorectal polyps with regard to polyp histology. We classified the diagnoses into high confidence (i.e., cases in which the endoscopist could assign a diagnosis with certainty) and low confidence diagnoses (i.e., cases in which the endoscopist preferred to send the polyp for formal histology). Mean sensitivity, specificity and accuracy per endoscopist/image were computed and differences between groups tested using independent-samples t tests. High vs low confidence diagnoses were compared using the pairedsamples t test. RESULTS:Eleven endoscopists without previous experience on optical diagnosis evaluated a total of 550 images (396 adenomatous, 154 non-adenomatous). Mean sensitivity, specificity and accuracy for diagnosing adenomas were 79.3%, 85.7% and 81.1%, respectively. No significant differences were found between gastroenterologists and trainees regarding performances of optical diagnosis (mean accuracy 78.0%vs 82.9%,P = 0.098). Diminutive lesions were predicted with a lower mean accuracy as compared to non-diminutive lesions (74.2% vs 93.1%, P = 0.008). A total of 446 (81.1%) diagnoses were made with high confidence. High confidence diagnoses corresponded to a significantly higher mean accuracy than low confidence diagnoses (84.0% vs 64.3%, P = 0.008). A total of 319 (58.0%) images were evaluated as having excellent quality. Considering excellent quality images in conjunction with high confidence diagnosis, overall accuracy increased to 92.8%. CONCLUSION:After a single training session, endoscopists with varying levels of experience can already provide optical diagnosis with an accuracy of 84.0%. 展开更多
关键词 COLONOSCOPY high-definition i-scan Optical diagnosis Colorectal POLYPS Training
暂未订购
A Reliable Adaptive High-Definition Transmission System for Distance Learning
7
作者 徐奇 李鹤廷 《Journal of Shanghai Jiaotong university(Science)》 EI 2007年第6期740-743,共4页
There is an increasing demand for supporting high-quality real-time audiovisual services for the next generation wired and wireless networks. However, due to variety of bandwidths of different networks, it is a great ... There is an increasing demand for supporting high-quality real-time audiovisual services for the next generation wired and wireless networks. However, due to variety of bandwidths of different networks, it is a great challenge for deployment. In this paper, a novel high-definition (HD) video transmission system was proposed which depends upon reliable compound multicast protocols and QoS control over the various kinds of networks. This system detects client's network condition and assigns it to a proper proxy. Each proxy is capable of detecting network parameters and adaptively tuning such transport parameters as bit rate, video resolution, frame rate and QoS mechanisms to this condition. It also provides FEC error recovery under consideration of characteristics of MPEG4 video codec. Our simulation demonstrates that different network clients such as ADSL, CERNET, and CERNET2 can receive more video reliability with less delay. 展开更多
关键词 ADAPTIVE high-definition(HD) transmission system distance learning RELIABLE compound MULTICAST protocol (RCMP)
在线阅读 下载PDF
Software-aided efficient identification of the components of compound formulae and their metabolites in rats by UHPLC/IM-QTOF-MS and an in-house high-definition MS^(2) library: Sishen formula as a case
8
作者 Lili Hong Wei Wang +9 位作者 Shiyu Wang Wandi Hu Yuyang Sha Xiaoyan Xu Xiaoying Wang Kefeng Li Hongda Wang Xiumei Gao De-an Guo Wenzhi Yang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第10期1484-1495,共12页
Identifying the compound formulae-related xenobiotics in bio-samples is full of challenges.Conventional strategies always exhibit the insufficiencies in overall coverage,analytical efficiency,and degree of automation,... Identifying the compound formulae-related xenobiotics in bio-samples is full of challenges.Conventional strategies always exhibit the insufficiencies in overall coverage,analytical efficiency,and degree of automation,and the results highly rely on the personal knowledge and experience.The goal of this work was to establish a software-aided approach,by integrating ultra-high performance liquid chromatography/ion-mobility quadrupole time-of-flight mass spectrometry(UHPLC/IM-QTOF-MS)and in-house high-definition MS^(2) library,to enhance the identification of prototypes and metabolites of the compound formulae in vivo,taking Sishen formula(SSF)as a template.Seven different MS2 acquisition methods were compared,which demonstrated the potency of a hybrid scan approach(namely high-definition data-independent/data-dependent acquisition(HDDIDDA))in the identification precision,MS1 coverage,and MS^(2) spectra quality.The HDDIDDA data for 55 reference compounds,four component drugs,and SSF,together with the rat bio-samples(e.g.,plasma,urine,feces,liver,and kidney),were acquired.Based on the UNIFI™platform(Waters),the efficient data processing workflows were established by combining mass defect filtering(MDF)-induced classification,diagnostic product ions(DPIs),and neutral loss filtering(NLF)-dominated structural confirmation.The high-definition MS^(2) spectral libraries,dubbed in vitro-SSF and in vivo-SSF,were elaborated,enabling the efficient and automatic identification of SSF-associated xenobiotics in diverse rat bio-samples.Consequently,118 prototypes and 206 metabolites of SSF were identified,with the identification rate reaching 80.51%and 79.61%,respectively.The metabolic pathways mainly involved the oxidation,reduction,hydrolysis,sulfation,methylation,demethylation,acetylation,glucuronidation,and the combined reactions.Conclusively,the proposed strategy can drive the identification of compound formulae-related xenobiotics in vivo in an intelligent manner. 展开更多
关键词 Ultra-high performance liquid chromatography/ion-mobility quadrupole time-of-flight mass spectrometry(UHPLC/IM-QTOF-MS) Hybrid scan high-definition MS^(2)spectral library Sishen formula
暂未订购
Fast-zoom and high-resolution sparse compound-eye camera based on dual-end collaborative optimization 被引量:1
9
作者 Yi Zheng Hao-Ran Zhang +5 位作者 Xiao-Wei Li You-Ran Zhao Zhao-Song Li Ye-Hao Hou Chao Liu Qiong-Hua Wang 《Opto-Electronic Advances》 2025年第6期4-15,共12页
Due to the limitations of spatial bandwidth product and data transmission bandwidth,the field of view,resolution,and imaging speed constrain each other in an optical imaging system.Here,a fast-zoom and high-resolution... Due to the limitations of spatial bandwidth product and data transmission bandwidth,the field of view,resolution,and imaging speed constrain each other in an optical imaging system.Here,a fast-zoom and high-resolution sparse compound-eye camera(CEC)based on dual-end collaborative optimization is proposed,which provides a cost-effective way to break through the trade-off among the field of view,resolution,and imaging speed.In the optical end,a sparse CEC based on liquid lenses is designed,which can realize large-field-of-view imaging in real time,and fast zooming within 5 ms.In the computational end,a disturbed degradation model driven super-resolution network(DDMDSR-Net)is proposed to deal with complex image degradation issues in actual imaging situations,achieving high-robustness and high-fidelity resolution enhancement.Based on the proposed dual-end collaborative optimization framework,the angular resolution of the CEC can be enhanced from 71.6"to 26.0",which provides a solution to realize high-resolution imaging for array camera dispensing with high optical hardware complexity and data transmission bandwidth.Experiments verify the advantages of the CEC based on dual-end collaborative optimization in high-fidelity reconstruction of real scene images,kilometer-level long-distance detection,and dynamic imaging and precise recognition of targets of interest. 展开更多
关键词 compound-eye camera ZOOM high resolution collaborative optimization
在线阅读 下载PDF
Photometry-free sky area visibility estimation method for All-sky Camera 被引量:1
10
作者 Haiwen Xie Hui Zhi +4 位作者 Zhe Kang Shiyu Deng Bingli Niu Lei Wang Xiaojun Jiang 《Astronomical Techniques and Instruments》 2025年第1期52-64,共13页
Observatories typically deploy all-sky cameras for monitoring cloud cover and weather conditions.However,many of these cameras lack scientific-grade sensors,r.esulting in limited photometric precision,which makes calc... Observatories typically deploy all-sky cameras for monitoring cloud cover and weather conditions.However,many of these cameras lack scientific-grade sensors,r.esulting in limited photometric precision,which makes calculating the sky area visibility distribution via extinction measurement challenging.To address this issue,we propose the Photometry-Free Sky Area Visibility Estimation(PFSAVE)method.This method uses the standard magnitude of the faintest star observed within a given sky area to estimate visibility.By employing a pertransformation refitting optimization strategy,we achieve a high-precision coordinate transformation model with an accuracy of 0.42 pixels.Using the results of HEALPix segmentation is also introduced to achieve high spatial resolution.Comprehensive analysis based on real allsky images demonstrates that our method exhibits higher accuracy than the extinction-based method.Our method supports both manual and robotic dynamic scheduling,especially under partially cloudy conditions. 展开更多
关键词 All-sky cameras Astronomy image processing Ground-based astronomy Calibration Computational methods Observational astronomy
在线阅读 下载PDF
Application of Visual High-definition Rigid Bronchoscope in Removal of Complicated Respiratory Foreign Body
11
作者 HE Meng CHENG Yanbin BAO Yan 《外文科技期刊数据库(文摘版)医药卫生》 2021年第12期997-1000,共6页
Objective: to explore and analyze the effect of applying visual high-definition rigid bronchoscopy in the removal of complicated respiratory foreign body. Methods: from September 2017 to June 2020, 97 patients with co... Objective: to explore and analyze the effect of applying visual high-definition rigid bronchoscopy in the removal of complicated respiratory foreign body. Methods: from September 2017 to June 2020, 97 patients with complex foreign body in respiratory tract with valid data registered in the database of our hospital were selected as the research subjects. The basic data of the patients were statistically analyzed. All the patients in this study had complicated foreign body obstruction in respiratory tract. After admission, the medical staff gave the patients visual high-definition rigid bronchoscopy for auxiliary treatment, and the final treatment effect was evaluated and analyzed. Results: in this study, 97 patients with complex foreign body in respiratory tract were improved after treatment, with a total effective rate of 100%. In this study, there were 2 patients with respiratory tract injury during surgery, with an incidence rate of 2.06%. Conclusion: in the removal of complicated respiratory foreign body, the choice of visual high-definition rigid bronchoscope for treatment can help medical staff to identify respiratory foreign body and promote the outcome of the patient's condition, which has good promotion value and is worthy of further application. 展开更多
关键词 visual high-definition rigid bronchoscopy removal of complex respiratory foreign body treatment op
暂未订购
无靶标LiDAR/IMU/Camera时空标定关键技术研究
12
作者 李圣雨 《武汉大学学报(信息科学版)》 北大核心 2025年第11期2400-2400,共1页
现有的激光雷达(light detection and ranging,LiDAR)/惯性测量单元(inertial measurement unit,IMU)/相机(Camera)标定方法普遍依赖特制靶标等先验知识,而且会因为采用离散时间建模而损失精度,无法满足高精度、高一致性、高灵活性的时... 现有的激光雷达(light detection and ranging,LiDAR)/惯性测量单元(inertial measurement unit,IMU)/相机(Camera)标定方法普遍依赖特制靶标等先验知识,而且会因为采用离散时间建模而损失精度,无法满足高精度、高一致性、高灵活性的时空标定应用需求。针对多源融合对高精度时空参数的迫切需求,围绕LiDAR/IMU/Camera时空标定开展了深入的研究。针对离线和在线不同标定需求,分别建立了一套基于连续时间的LiDAR/IMU/Camera离线高精度标定体系和GNSS原始观测值辅助的LiDAR/IMU/Camera自主在线标定体系。 展开更多
关键词 camera 高精度 离线标定 IMU LIDAR 时空标定 连续时间
原文传递
YOLO-Fastest-IR:Ultra-lightweight thermal infrared face detection method for infrared thermal camera
13
作者 LI Xi-Cai ZHU Jia-He +1 位作者 DONG Peng-Xiang WANG Yuan-Qing 《红外与毫米波学报》 北大核心 2025年第5期790-800,共11页
This paper presents a high-speed and robust dual-band infrared thermal camera based on an ARM CPU.The system consists of a low-resolution long-wavelength infrared detector,a digital temperature and humid⁃ity sensor,an... This paper presents a high-speed and robust dual-band infrared thermal camera based on an ARM CPU.The system consists of a low-resolution long-wavelength infrared detector,a digital temperature and humid⁃ity sensor,and a CMOS sensor.In view of the significant contrast between face and background in thermal infra⁃red images,this paper explores a suitable accuracy-latency tradeoff for thermal face detection and proposes a tiny,lightweight detector named YOLO-Fastest-IR.Four YOLO-Fastest-IR models(IR0 to IR3)with different scales are designed based on YOLO-Fastest.To train and evaluate these lightweight models,a multi-user low-resolution thermal face database(RGBT-MLTF)was collected,and the four networks were trained.Experiments demon⁃strate that the lightweight convolutional neural network performs well in thermal infrared face detection tasks.The proposed algorithm outperforms existing face detection methods in both positioning accuracy and speed,making it more suitable for deployment on mobile platforms or embedded devices.After obtaining the region of interest(ROI)in the infrared(IR)image,the RGB camera is guided by the thermal infrared face detection results to achieve fine positioning of the RGB face.Experimental results show that YOLO-Fastest-IR achieves a frame rate of 92.9 FPS on a Raspberry Pi 4B and successfully detects 97.4%of faces in the RGBT-MLTF test set.Ultimate⁃ly,an infrared temperature measurement system with low cost,strong robustness,and high real-time perfor⁃mance was integrated,achieving a temperature measurement accuracy of 0.3℃. 展开更多
关键词 artificial intelligence infrared face detection ultra-lightweight network infrared thermal camera YOLO-Fastest-IR
在线阅读 下载PDF
Blackmagic Micro Studio Camera 4K G2现支持Blackmagic PYXIS Monitor
14
《影视制作》 2025年第7期119-119,共1页
日前,Blackmagic Camera 9.6版软件更新已推出。新版本为Blackmagic Micro Studio Camera4K G2搭配使用Blackmagic PYXIS Monitor时添加了视频监看和触摸屏控制支持。如此一来,可更轻松地取景和对焦镜头,以及更改摄影机设置。
关键词 Blackmagic Micro Studio camera 4K G2 Blackmagic camera
在线阅读 下载PDF
iOS版Blackmagic Camera 3.2发布
15
《影视制作》 2025年第11期119-119,共1页
Blackmagic Camera for iOS 3.2版本可直接从i Phone推流到You Tube、Vimeo和Twitch,无需借助其他硬件或第三方软件,只要选择平台、输入推流密钥,就能以专业质量直播。本次更新还加入了对SRT推流的支持,可以把高质量、低延迟的视频发送... Blackmagic Camera for iOS 3.2版本可直接从i Phone推流到You Tube、Vimeo和Twitch,无需借助其他硬件或第三方软件,只要选择平台、输入推流密钥,就能以专业质量直播。本次更新还加入了对SRT推流的支持,可以把高质量、低延迟的视频发送到Blackmagic Streaming Decoder或其他支持SRT的广电制作系统,非常适合远程制作、新闻采集、活动实况报道。另外,现在用外部存储时会有更清晰的通知信息。当硬盘在录制、待机或上传素材过程中被断开时,警告会立即出现。 展开更多
关键词 3.2版本 Blackmagic camera IOS
在线阅读 下载PDF
Camera Planning for Physical Safety of Outdoor Electronic Devices:Perspective and Analysis
16
作者 Qin Su Lei Shu +5 位作者 Gerhard Petrus Hancke Kai Huang Edmond Nurellari Qingsong Zhao Nikumani Choudhury Anakhi Hazarika 《IEEE/CAA Journal of Automatica Sinica》 2025年第8期1530-1543,共14页
Camera technology advancement and deployment continue to play a vital role in modern life and production,amongst other capabilities,generating relevant visual information.The challenge of optimizing the use and deploy... Camera technology advancement and deployment continue to play a vital role in modern life and production,amongst other capabilities,generating relevant visual information.The challenge of optimizing the use and deployment of camera networks in various applications(e.g.,surveillance,traffic monitoring,and public safety to name but just a few)has attracted considerable attention from both academia and industries.Camera planning is the first step in addressing this challenge.The surveillance objectives and scenes of a camera network dictate the modelling and optimization algorithms for camera planning.However,existing reviews have primarily focused on models or optimization algorithms,with insufficient attention given to surveillance scenes.This review aims to bridge this gap by 1)Classifying surveillance scenes into the urban environment and rural outdoor environment and comparing the surveillance requirements and challenges;2)Summarizing the details of camera coverage optimization in the relevant literature from the perspective of deployment scenes;and 3)Proposing a new surveillance scene-Solar Insecticidal Lamps with the Internet of Things—as a case study to analyze the surveillance requirement and challenges in agricultural outdoor environment.Finally,we state the technical outlook on the physical safety of outdoor electronic devices in agriculture settings and provide insights to draw more attention and effort into this area. 展开更多
关键词 camera planning physical safety smart outdoor devices SURVEILLANCE
在线阅读 下载PDF
Design and Implementation of a 360°Panorama Imaging System Based on Motor-Driven Fisheye Camera
17
作者 Yongsheng Sun Xiaojuan Li +3 位作者 Guanjiang Liu Yue Li Huayang Zheng Jianke Li 《Journal of Electronic Research and Application》 2025年第6期127-138,共12页
This paper designs and implements a single-camera 360°panoramic imaging system based on motor-driven fisheye rotation.The system utilizes a stepper motor for precise angular control,enabling the camera to rotate ... This paper designs and implements a single-camera 360°panoramic imaging system based on motor-driven fisheye rotation.The system utilizes a stepper motor for precise angular control,enabling the camera to rotate around its optical center to capture multi-view images,thereby avoiding the parallax and geometric mismatch problems inherent in traditional multi-camera configurations.To address the strong distortion characteristics of fisheye images,an equidistant projection model is adopted for distortion correction.On this basis,a brightness normalization method combining global linear brightness correction and local illumination compensation is proposed to enhance stitching consistency.By establishing a geometry model constrained by camera rotation and integrating cylindrical projection with cosine-weighted blending,the system achieves high-precision panoramic stitching and seamless visual transitions. 展开更多
关键词 Fisheye camera Optical center alignment Brightness normalization Panoramic stitching
在线阅读 下载PDF
3D trajectory reconstruction of moving points based on asynchronous cameras
18
作者 Huayu Huang Yang Shang +1 位作者 Banglei Guan Qifeng Yu 《Acta Mechanica Sinica》 2025年第7期197-210,共14页
Photomechanics is a crucial branch of solid mechanics.The localization of point targets constitutes a fundamental problem in optical experimental mechanics,with extensive applications in various missions of unmanned a... Photomechanics is a crucial branch of solid mechanics.The localization of point targets constitutes a fundamental problem in optical experimental mechanics,with extensive applications in various missions of unmanned aerial vehicles.Localizing moving targets is crucial for analyzing their motion characteristics and dynamic properties.Reconstructing the trajectories of points from asynchronous cameras is a significant challenge.It encompasses two coupled sub-problems:Trajectory reconstruction and camera synchronization.Present methods typically address only one of these sub-problems individually.This paper proposes a 3D trajectory reconstruction method for point targets based on asynchronous cameras,simultaneously solving both sub-problems.Firstly,we extend the trajectory intersection method to asynchronous cameras to resolve the limitation of traditional triangulation that requires camera synchronization.Secondly,we develop models for camera temporal information and target motion,based on imaging mechanisms and target dynamics characteristics.The parameters are optimized simultaneously to achieve trajectory reconstruction without accurate time parameters.Thirdly,we optimize the camera rotations alongside the camera time information and target motion parameters,using tighter and more continuous constraints on moving points.The reconstruction accuracy is significantly improved,especially when the camera rotations are inaccurate.Finally,the simulated and real-world experimental results demonstrate the feasibility and accuracy of the proposed method.The real-world results indicate that the proposed algorithm achieved a localization error of 112.95 m at an observation distance range of 15-20 km. 展开更多
关键词 PHOTOMECHANICS 3D trajectory reconstruction Asynchronous cameras Temporal polynomials Bundle adjustment
原文传递
Blackmagic发布Camera ProDock,支持i Phone 17 Pro Genlock
19
《影视制作》 2025年第9期118-118,共1页
9月10日,Blackmagic发布了Camera ProDock,这款新的扩展坞为i Phone 17 Pro和17 ProMax添加了专业摄影机接口,包括同步锁相(Genlock)、外部时间码、HDMI输出、耳机和麦克风输入以及外部存储盘录制等功能。Genlock是用于多机位视频拍摄... 9月10日,Blackmagic发布了Camera ProDock,这款新的扩展坞为i Phone 17 Pro和17 ProMax添加了专业摄影机接口,包括同步锁相(Genlock)、外部时间码、HDMI输出、耳机和麦克风输入以及外部存储盘录制等功能。Genlock是用于多机位视频拍摄的同步技术,它通过统一信号锁定所有摄像机的帧时间,从而实现时间线精确对齐,避免出现画面不同步的问题。 展开更多
关键词 camera ProDock i Phone 17 Pro
在线阅读 下载PDF
Intelligent detection method for internal fractures in mine rock masses based on borehole camera images
20
作者 Xinbo Ma Fuming Qu +2 位作者 Wenxuan He Liancheng Wang Xiaobo Liu 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第8期4802-4814,共13页
It is important to understand the development of joints and fractures in rock masses to ensure drilling stability and blasting effectiveness.Traditional manual observation techniques for identifying and extracting fra... It is important to understand the development of joints and fractures in rock masses to ensure drilling stability and blasting effectiveness.Traditional manual observation techniques for identifying and extracting fracture characteristics have been proven to be inefficient and prone to subjective interpretation.Moreover,conventional image processing algorithms and classical deep learning models often encounter difficulties in accurately identifying fracture areas,resulting in unclear contours.This study proposes an intelligent method for detecting internal fractures in mine rock masses to address these challenges.The proposed approach captures a nodal fracture map within the targeted blast area and integrates channel and spatial attention mechanisms into the ResUnet(RU)model.The channel attention mechanism dynamically recalibrates the importance of each feature channel,and the spatial attention mechanism enhances feature representation in key areas while minimizing background noise,thus improving segmentation accuracy.A dynamic serpentine convolution module is also introduced that adaptively adjusts the shape and orientation of the convolution kernel based on the local structure of the input feature map.Furthermore,this method enables the automatic extraction and quantification of borehole nodal fracture information by fitting sinusoidal curves to the boundaries of the fracture contours using the least squares method.In comparison to other advanced deep learning models,our enhanced RU demonstrates superior performance across evaluation metrics,including accuracy,pixel accuracy(PA),and intersection over union(IoU).Unlike traditional manual extraction methods,our intelligent detection approach provides considerable time and cost savings,with an average error rate of approximately 4%.This approach has the potential to greatly improve the efficiency of geological surveys of borehole fractures. 展开更多
关键词 Fracture detection Borehole camera images Convolutional neural networks(CNNs) Attention mechanism
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部