Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation o...Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method.展开更多
Based on the monitoring results of environmental quality in Yueqing Bay during 2007-2014,the current situation of environmental quality in the bay was analyzed and assessed. The results show that pH,DO,CODMn,petroleum...Based on the monitoring results of environmental quality in Yueqing Bay during 2007-2014,the current situation of environmental quality in the bay was analyzed and assessed. The results show that pH,DO,CODMn,petroleum,and heavy metals( Cu,Pb,Zn,Cd,Hg,As and Cr)in the seawater of Yueqing Bay did not exceed the second class standard of Seawater Quality Standard( GB 3097-1997),but inorganic nitrogen and reactive phosphate in the seawater of Yueqing Bay exceeded the second class standard seriously,and the water quality of the bay was in an eutrophic state; the standard index of evaluation factors of sediment quality was smaller than 1,meeting the demands of sediment quality for environmental protection.展开更多
In 2015, the area of first and second class land in Tongnan Distdct of Chongqing was 221.646 km2, accounting for 30% of the total cultivated area, and the area of the third, fourth and fifth class land was 517.861 km2...In 2015, the area of first and second class land in Tongnan Distdct of Chongqing was 221.646 km2, accounting for 30% of the total cultivated area, and the area of the third, fourth and fifth class land was 517.861 km2, accounting for 70% of the total cultivated area. The quality of cultivated land was at a low level. Comparison with the Second Soil Census in 2015 showed that the soil pH value has been improved; the organic matter content in the tillage layer showed a slight upward trend; the contents of available nitrogen, available phosphorus and available potassium in the topsoil increased. Countermeasures were proposed as follows: vig- orously promote the construction of high-standard farmland; adjust the industrial structure of agriculture and implement farming reform; combine organic and inorgan- ic fertilization to reduce the amount of fertilizers; popularize soil testing and formu- lated fertilization to change farmers' traditional fertilization habits; improve pollution control to ensure the sustainable productivity of farmland; strictly promote the quality management of cultivated land and strengthen the construction of quality monitoring system; increase investment and improve the monitoring mechanism; vigorously publicize and enhance the awareness of all citizens in protecting cultivated land; im- prove the law of cultivated land protection and enhance the seriousness of the law on the protection of cultivated land.展开更多
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w...In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.展开更多
In order to expand and strengthen the cucumber industry in Linyi City of Shandong City and make it more effective in revitalizing the rural economy,the authors surveyed the current situation of the cucumber planting a...In order to expand and strengthen the cucumber industry in Linyi City of Shandong City and make it more effective in revitalizing the rural economy,the authors surveyed the current situation of the cucumber planting area,production management,fresh-keeping processing and marketing in Linyi City.Based on the survey,it analyzed the current problems in the development of the cucumber industry in Linyi City,including low level of facilities and equipment,the post-picking processing technology,the imperfect quality control system,the low degree of information and the weak degree of organization.Finally,it came up with recommendations including developing increasing modern technological innovation of facility structure and equipment,accelerating research on post-picking commercial processing technology of cucumber,accelerating the construction of product quality traceability system,promoting in-depth integration of informationization and cucumber industry,and improving the degree of organization and industrialization,to improve the quality and benefits of cucumber industry,so as to provide guidance for improving the overall quality,benefit and market competitiveness of cucumber industry in Linyi City.展开更多
Background: Transcranial direct current stimulation (tDCS) has research evidence that it can reduce symptoms of depression. Flow FL-100 is a transcranial direct current stimulation (tDCS) device self-administered by a...Background: Transcranial direct current stimulation (tDCS) has research evidence that it can reduce symptoms of depression. Flow FL-100 is a transcranial direct current stimulation (tDCS) device self-administered by a patient at home in combination with a software application that delivers wellbeing behaviour therapy training. Purpose/aim: The purpose of this study was to investigate if Flow can be introduced to a Crisis Resolution & Home Treatment (CRT) service and the impact of Flow in treating depression. The study addresses the questions: 1) “what are the depression reliable improvement and remission rates?” and 2) “can Flow significantly reduce depressive symptoms and improve real world functioning (every-day, social and occupational functioning) and health-related quality of life?”. Methods: An open-label patient cohort design with no control group. Pre-intervention and 6-week follow-up intervention assessments using the participant self-report measures: Patient Health Questionnaire (PHQ-9), Work and Social Adjustment Scale (WSAS), and EuroQol five-dimension (EQ-5D-5L). Participants were 49 CRT patients, 19 males and 30 females, with an age range of 20 to 66 years, and average age of 42 years. Results: PHQ-9 reliable improvement and remission rates were 57.1% and 14.3%. PHQ-9 scores significantly improved, from 23.1 (SD 3.44) to 14.8 (SD 6.82) at 6 weeks, with a large effect size. PHQ-9 suicide/self-harm related question significantly improved from 2.51 (SD 0.77) to 1.08 (SD 1.17), with a large effect size. WSAS scores significantly improved, from 33.6 (SD 5.22) to 21.9 (SD 10.82) at 6 weeks, with a large effect size. EQ-5D-5L results showed significant improvements in the health index score, global assessment of health EQ-VAS from 34.2 (22.26) to 51.6 (24.95), and three EQ-5D-5L dimensions (“self-care”, “usual activity”, and “anxiety/depression”). Conclusion: A CRT service effectively integrated Flow tDCS treatment. Flow was beneficial in terms of improving functioning and quality of life and reducing depression symptoms and thoughts of suicide/self-harm. Flow FL100 tDCS and wellbeing behaviour therapy training could be offered through all CRT services to treat depression, reduce thoughts of suicide/self-harm, enable better functioning, and improve quality of life.展开更多
The current situation of employment quality in China allows no optimist during the period of economic transition. The disequilibrium is the most stressing characteristic in China's employment quality. The disequilibr...The current situation of employment quality in China allows no optimist during the period of economic transition. The disequilibrium is the most stressing characteristic in China's employment quality. The disequilibrium of this kind of level of the employment quality not only reflects among the areas where the economic development levels are different, but also reflects more differences of the employment quality due to the differences of the worker's identity in the labor market. At present, the problems of employment quality in China are mainly reflected in the labor contracts, working time, labor remuneration, job stability, safety in production, job hygiene, social security, and the respects of basic human rights and participating in the democratic management by the laborers, etc. During the economic transition period, the work relation fields in China appear some special colonies, such as the farmer's colony, the colony of ownership transformed enterprises, the colony of flexible persons who obtain employment themselves, whose employment quality demonstrates the questions of some peculiar ones and need special concern.展开更多
Wire-arc directed energy deposition(wire-arc DED)enables the fabrication of large-scale metal components with rapid manufacturing ability and diverse material selection,making it a compelling technology in industries ...Wire-arc directed energy deposition(wire-arc DED)enables the fabrication of large-scale metal components with rapid manufacturing ability and diverse material selection,making it a compelling technology in industries and defenses.However,challenges in both macroscale and microscale defects still limit printed component widespread applications.Recent advances in automatic and intelligent technologies have brought a range of quality controllable strategies to the forefront.This review covers these new strategies for the printing component,including path planning,process monitoring,auxiliary processes,and post processing,while discussing the expectation for structure and quality improvement.In addition,the work brings new areas of intelligent wire-arc DED development,including advances in digital twin,visualization,and human-processing interaction to promote its performance.It is anticipated that a focus on intelligent system will be key to smart and high-quality manufacturing for future wire-arc DED.展开更多
Objective:to study the effect of automatic tube current modulation on abdominal CT image quality and radiation dose. Methods: a total of 70 patients who underwent abdominal CT examination in our hospital from August 2...Objective:to study the effect of automatic tube current modulation on abdominal CT image quality and radiation dose. Methods: a total of 70 patients who underwent abdominal CT examination in our hospital from August 2019 to August 2020 were collected and divided into control group (35 cases) and study group (35 cases) according to the random number table. CT scan was performed in the control group according to the conventional parameters, while CT scan was performed in the research group using automatic tube current modulation technology. The CT image quality and radiation dose of patients in the two groups were compared. Results: the image quality of the study group was better than that of the control group (P < 0.05). When NI ≥8, the radiation dose in the study group was lower than that in the control group (P < 0.05). Conclusion Automatic tube current modulation technique can obtain better image quality in CT detection, and has significant significance in reducing radiation dose. It is worthy of affirmation, praise and application.展开更多
Energy is the bedrock of national economic development and a vital pillar for achieving sustainable growth.High-quality energy cooperation is critical to ensuring sustained,stable national economic development and the...Energy is the bedrock of national economic development and a vital pillar for achieving sustainable growth.High-quality energy cooperation is critical to ensuring sustained,stable national economic development and the transformation of the energy sector.Based on the achievements of high-quality energy cooperation within the Belt and Road Initiative,this paper systematically analyzes the current state of energy cooperation under the Belt and Road Initiative.In accordance with the intrinsic requirements for high-quality energy cooperation,and building upon the analysis and summary of prior research,this paper proposes strategies to promote high-quality energy cooperation within the Belt and Road Initiative:(1)Innovating cooperative concepts and optimizing the cooperative environment;(2)Innovating cooperation modes and expanding the scope of cooperation;(3)Improving the cooperation mechanism and building a multi-level cooperation platform;(4)Strengthening cultural exchanges and promoting dialogue.This paper offers insights and support for fostering high-quality collaboration within the Belt and Road Initiative and enhancing international energy cooperation.展开更多
This study addresses the critical challenge of reconfiguration in unbalanced power distribution networks(UPDNs),focusing on the complex 123-Bus test system.Three scenarios are investigated:(1)simultaneous power loss r...This study addresses the critical challenge of reconfiguration in unbalanced power distribution networks(UPDNs),focusing on the complex 123-Bus test system.Three scenarios are investigated:(1)simultaneous power loss reduction and voltage profile improvement,(2)minimization of voltage and current unbalance indices under various operational cases,and(3)multi-objective optimization using Pareto front analysis to concurrently optimize voltage unbalance index,active power loss,and current unbalance index.Unlike previous research that oftensimplified system components,this work maintains all equipment,including capacitor banks,transformers,and voltage regulators,to ensure realistic results.The study evaluates twelve metaheuristic algorithms to solve the reconfiguration problem(RecPrb)in UPDNs.A comprehensive statistical analysis is conducted to identify the most efficient algorithm for solving the RecPrb in the 123-Bus UPDN,employing multiple performance metrics and comparative techniques.The Artificial Hummingbird Algorithm emerges as the top-performing algorithm and is subsequently applied to address a multi-objective optimization challenge in the 123-Bus UPDN.This research contributes valuable insights for network operators and researchers in selecting suitable algorithms for specific reconfiguration scenarios,advancing the field of UPDN optimization and management.展开更多
Utilization of Micro Hydro Power Plant at the Gunung Halu case study type run-off the river is a household use only in the afternoon,around 5 pm until bedtime at about 10 pm.Therefore,more than 75%of the energy is los...Utilization of Micro Hydro Power Plant at the Gunung Halu case study type run-off the river is a household use only in the afternoon,around 5 pm until bedtime at about 10 pm.Therefore,more than 75%of the energy is lost.This case study lost power which can be used as a by-product,such as for drying coffee beans.In this case study,a design was carried out to obtain by-products and improve power quality in the electrical system.In addition,they complain about the poor quality of power controlled by frequency using Triac-Based Electronic Dummy Load Control.The heat from the dummy load in the case study is used as a by-product.MHP with a minimum power of 20 kW,and the usage time of customer service is about 6 h.The energy for the by-products is about 360 kWh/day,and the power quality improved by using Triac-Based Electronic Load Control and Hysteresis Current Control for the active filter.As a result,the power factor is close to one,the generator current harmonics is less than 2%,and the voltage harmonics is less than 5%.展开更多
AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-c...AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-centre study,consecutive patients in sinus rhythm underwent CCTA for suspected coronary artery disease(CAD)using a 320-row detector CT scanner.All patients underwent the standard CT acquisition protocol at our institute(Morriston Hospital)a combination of dose saving advances including prospective electrocardiogram-gating,automated tube current modulation,tube voltage reduction,heart rate reduction,and the most recent novel adaptive iterative dose reconstruction 3D(AIDR3D)algorithm.The cohort comprised real-world patients for routine CCTA who were not selected on age,body mass index,or heart rate.Subjective image quality was graded on a 4-point scale(4=excellent,1=non-diagnostic).RESULTS A total of 543 patients were included in the study with a mean body weight of 81±18 kg and a pre-scan mean heart rate of 70±11 beats per minute(bpm).When indicated,patients received rate-limiting medication with an oral beta-blocker followed by additional intravenous beta-blocker to achieve a heart rate below 65 bpm.The median effective radiation dose was 0.88 mSv(IQR,0.6-1.4 mSv)derived from a Dose Length Product of61.45 mGy.cm(IQR,42.86-100.00 mGy.cm).This also includes what we believe to be the lowest ever-reported radiation dose for a routine clinical CCTA(0.18 mSv).The mean image quality(SD)was 3.65±0.61,with a subjective image quality score of 3("good")or above for 93%of patient CCTAs.CONCLUSION Combining a low-dose scan protocol and AIDR3D with a 320-detector row CT scanner can provide high quality images at exceptionally low radiation dose in unselected patients being investigated for CAD.展开更多
Electrochemical polishing is the anodic dissolution process without contact with tools,is a surface treatment method to make a surface planarization using an electrochemical reaction with low applied current.The surfa...Electrochemical polishing is the anodic dissolution process without contact with tools,is a surface treatment method to make a surface planarization using an electrochemical reaction with low applied current.The surface quality is mainly affected by the many process parameters.To improve the surface quality,the control of parameters is very important.The aim of this study is to investigate the characteristic of electrochemical polishing effect for inner diameter of Stainless Steel Tube.In order to analyze the characteristics of surface quality were measured in terms of temperature, applied current and machining time.The investigation can enhance the surface quality of inner diameter Stainless Steel Tube.Therefore,we have verified improved results by using selected optimal conditions.展开更多
Based on the monitoring results of environmental quality of the waters near the Feiyun River estuary during 2011-2016, the current situation of environmental quality of the waters was analyzed and evaluated. The resul...Based on the monitoring results of environmental quality of the waters near the Feiyun River estuary during 2011-2016, the current situation of environmental quality of the waters was analyzed and evaluated. The results showed that pH, DO, COD Mn , petroleum, and heavy metals (Cu, Pb, Zn, Cd, Hg, As and Cr) in the waters near the Feiyun River estuary did not exceed the second-class standard of Seawater Quality Standard (GB 3097-1997), while both inorganic nitrogen and reactive phosphate in the waters exceeded the second-class standard obviously. The water quality of the waters near the Feiyun River estuary was in an eutrophic state. In terms of sediment quality, the standard index of most evaluation factors except for Cu was smaller than 1, meeting the demands of sediment quality for environmental protection.展开更多
Unregulated utilization of renewable generation including residential photovoltaic (PV) systems can have a significant impact on load characteristics in distribution networks. For improving PV generation capabilities,...Unregulated utilization of renewable generation including residential photovoltaic (PV) systems can have a significant impact on load characteristics in distribution networks. For improving PV generation capabilities, power quality aspects have to be coordinated with present load characteristics. This paper discusses the harmonic content of PV generation and the influence to power quality indicators in residential distribution networks. PV generation measurement results including current harmonic amplitude and phase angle values are presented. Results of different modelling scenarios are analysed and a simplified model of harmonics in PVs is offered. The results of the study showed a moderate additional harmonic distortion in residential load current and voltage distortion at the substation’s busbar when PVs were added. Novelty of the paper is that harmonic current values at higher orders are presented and analysed. The results pointed out in this paper could be further used for modelling the actual harmonic loads of the PVs in distribution networks.展开更多
The high utilization level of renewable generation including residential photovoltaic (PV) systems together with the uncontrolled charging of electric vehicles (EVs) can have a significant impact on load characteristi...The high utilization level of renewable generation including residential photovoltaic (PV) systems together with the uncontrolled charging of electric vehicles (EVs) can have a significant impact on load characteristics in distribution networks. Harmonic content of PV generation, EV charging loads, and their influence on power quality indicators in residential distribution networks are discussed in this paper. For investigating likely power quality scenarios, PV generation and EV charging measurement results including current harmonic amplitude and phase angle values are used and compared with present load characteristics. Different modelling scenarios are analysed and a simplified model of harmonics in PVs and EVs is offered. The results of the study show moderate additional harmonic distortion in residential load current and voltage distortion at the substation’s busbar when PV generation and EV loading are added. The scenarios presented in this paper can be further used for modelling the actual harmonic loads of the PVs and EVs in distribution networks.展开更多
<span style="font-family:Verdana;">Today, energy is a vital component in the functioning of a hospital. Hospital technical facilities have several types of technologies, these include appliances for us...<span style="font-family:Verdana;">Today, energy is a vital component in the functioning of a hospital. Hospital technical facilities have several types of technologies, these include appliances for use;examination apparatus. So, for Quality Health Care in a hospital, there is</span><span style="font-family:Verdana;"> a</span><span style="font-family:Verdana;"> need to ensure the proper functioning of hospital equipment. In addition to the required maintenance as specified by the device manufacturer, </span><span style="font-family:Verdana;">the </span><span style="font-family:Verdana;">quality of the electrical energy across the device must be ensured. This article is an analysis of the quality of electric energy at the substation of National Hospital of Niamey. Thereby, the data collection, followed by the data processing and analysis revealed the parameters characterizing the quality of electrical energy across the substation. Our studies have shown that the substation is underutilized as the maximum inrush current is less than half the available current. </span><span style="font-family:Verdana;">The </span><span style="font-family:Verdana;">current </span><span style="font-family:Verdana;">was </span><span style="font-family:Verdana;">consumed by the three phases ha</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> resulted </span><span style="font-family:Verdana;">in</span><span style="font-family:Verdana;"> a strong current unbalance (230</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">A). However, the current unbalance and the voltage amplitude</span><span style="font-family:Verdana;">,</span><span style="font-family:Verdana;"> are admissible according</span><span style="font-family:Verdana;">ly</span><span style="font-family:Verdana;"> base on EN50160 standard. Furthermore, the harmonics voltages present in this medium </span><span style="font-family:Verdana;">are</span><span style="font-family:Verdana;"> in the accepted range (1.8%) according to IEEE 519 standard. However, the fundamental frequency does not meet the standard, but the difference obtained has no adverse effect.</span>展开更多
The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is e...The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is exposed within the open which suggests they can be vulnerable to lightning strikes, road dwindling, windstorms, and a few engineering activities with the potential of causing different degrees of damage to the electrical equipment. One of the ways to guard the equipment is to deploy switching devices. However, the operations of most of these switching devices produce oscillatory transient in the electrical transmission and distribution systems which result in voltage, current, and frequency fluctuations in the load. This paper investigates the effect of switching devices on power quality and proposes a positive sequence voltage power transient suppression technique that can spontaneously improve the distorted voltage at the instant of capacitor switching using the capacitor line model as a case study. MATLAB/Simulink software was utilized for the analysis on an electrical network model with bus voltages of 69 kV/12.47 kV and 480 V. The results showed that, during switching operations, the positive sequence voltage power detector block produces ripple-free accurate results.展开更多
基金supported by National Natural Science Foundation of China (No. 61573303)Natural Science Foundation of Hebei Province (No. E2016203092)
文摘Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method.
基金Supported by National Natural Science Foundation of China(4127-6199)
文摘Based on the monitoring results of environmental quality in Yueqing Bay during 2007-2014,the current situation of environmental quality in the bay was analyzed and assessed. The results show that pH,DO,CODMn,petroleum,and heavy metals( Cu,Pb,Zn,Cd,Hg,As and Cr)in the seawater of Yueqing Bay did not exceed the second class standard of Seawater Quality Standard( GB 3097-1997),but inorganic nitrogen and reactive phosphate in the seawater of Yueqing Bay exceeded the second class standard seriously,and the water quality of the bay was in an eutrophic state; the standard index of evaluation factors of sediment quality was smaller than 1,meeting the demands of sediment quality for environmental protection.
文摘In 2015, the area of first and second class land in Tongnan Distdct of Chongqing was 221.646 km2, accounting for 30% of the total cultivated area, and the area of the third, fourth and fifth class land was 517.861 km2, accounting for 70% of the total cultivated area. The quality of cultivated land was at a low level. Comparison with the Second Soil Census in 2015 showed that the soil pH value has been improved; the organic matter content in the tillage layer showed a slight upward trend; the contents of available nitrogen, available phosphorus and available potassium in the topsoil increased. Countermeasures were proposed as follows: vig- orously promote the construction of high-standard farmland; adjust the industrial structure of agriculture and implement farming reform; combine organic and inorgan- ic fertilization to reduce the amount of fertilizers; popularize soil testing and formu- lated fertilization to change farmers' traditional fertilization habits; improve pollution control to ensure the sustainable productivity of farmland; strictly promote the quality management of cultivated land and strengthen the construction of quality monitoring system; increase investment and improve the monitoring mechanism; vigorously publicize and enhance the awareness of all citizens in protecting cultivated land; im- prove the law of cultivated land protection and enhance the seriousness of the law on the protection of cultivated land.
基金supported by the Shanghai Education Committee Scientific Research Subsidization (Grant No.05AZ30)the Specialized Research Fund for the Doctoral Program of Higher Education (Grant No. 20060280018)
文摘In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.
基金Vegetable Innovation Team of Modern Agricultural Industrial Technology System of Shandong Province(SDAIT-05-18).
文摘In order to expand and strengthen the cucumber industry in Linyi City of Shandong City and make it more effective in revitalizing the rural economy,the authors surveyed the current situation of the cucumber planting area,production management,fresh-keeping processing and marketing in Linyi City.Based on the survey,it analyzed the current problems in the development of the cucumber industry in Linyi City,including low level of facilities and equipment,the post-picking processing technology,the imperfect quality control system,the low degree of information and the weak degree of organization.Finally,it came up with recommendations including developing increasing modern technological innovation of facility structure and equipment,accelerating research on post-picking commercial processing technology of cucumber,accelerating the construction of product quality traceability system,promoting in-depth integration of informationization and cucumber industry,and improving the degree of organization and industrialization,to improve the quality and benefits of cucumber industry,so as to provide guidance for improving the overall quality,benefit and market competitiveness of cucumber industry in Linyi City.
文摘Background: Transcranial direct current stimulation (tDCS) has research evidence that it can reduce symptoms of depression. Flow FL-100 is a transcranial direct current stimulation (tDCS) device self-administered by a patient at home in combination with a software application that delivers wellbeing behaviour therapy training. Purpose/aim: The purpose of this study was to investigate if Flow can be introduced to a Crisis Resolution & Home Treatment (CRT) service and the impact of Flow in treating depression. The study addresses the questions: 1) “what are the depression reliable improvement and remission rates?” and 2) “can Flow significantly reduce depressive symptoms and improve real world functioning (every-day, social and occupational functioning) and health-related quality of life?”. Methods: An open-label patient cohort design with no control group. Pre-intervention and 6-week follow-up intervention assessments using the participant self-report measures: Patient Health Questionnaire (PHQ-9), Work and Social Adjustment Scale (WSAS), and EuroQol five-dimension (EQ-5D-5L). Participants were 49 CRT patients, 19 males and 30 females, with an age range of 20 to 66 years, and average age of 42 years. Results: PHQ-9 reliable improvement and remission rates were 57.1% and 14.3%. PHQ-9 scores significantly improved, from 23.1 (SD 3.44) to 14.8 (SD 6.82) at 6 weeks, with a large effect size. PHQ-9 suicide/self-harm related question significantly improved from 2.51 (SD 0.77) to 1.08 (SD 1.17), with a large effect size. WSAS scores significantly improved, from 33.6 (SD 5.22) to 21.9 (SD 10.82) at 6 weeks, with a large effect size. EQ-5D-5L results showed significant improvements in the health index score, global assessment of health EQ-VAS from 34.2 (22.26) to 51.6 (24.95), and three EQ-5D-5L dimensions (“self-care”, “usual activity”, and “anxiety/depression”). Conclusion: A CRT service effectively integrated Flow tDCS treatment. Flow was beneficial in terms of improving functioning and quality of life and reducing depression symptoms and thoughts of suicide/self-harm. Flow FL100 tDCS and wellbeing behaviour therapy training could be offered through all CRT services to treat depression, reduce thoughts of suicide/self-harm, enable better functioning, and improve quality of life.
文摘The current situation of employment quality in China allows no optimist during the period of economic transition. The disequilibrium is the most stressing characteristic in China's employment quality. The disequilibrium of this kind of level of the employment quality not only reflects among the areas where the economic development levels are different, but also reflects more differences of the employment quality due to the differences of the worker's identity in the labor market. At present, the problems of employment quality in China are mainly reflected in the labor contracts, working time, labor remuneration, job stability, safety in production, job hygiene, social security, and the respects of basic human rights and participating in the democratic management by the laborers, etc. During the economic transition period, the work relation fields in China appear some special colonies, such as the farmer's colony, the colony of ownership transformed enterprises, the colony of flexible persons who obtain employment themselves, whose employment quality demonstrates the questions of some peculiar ones and need special concern.
基金fully appreciate financial support from NingXia Natural Science Foundation for Outstanding Young Scholar(No.2024AAC04002)CAS“Light of West China”Program,National Natural Science Foundation of China(Key Program,No.12232013)Natural Science Foundation of Ningxia(Key Program,No.2022AAC2003)。
文摘Wire-arc directed energy deposition(wire-arc DED)enables the fabrication of large-scale metal components with rapid manufacturing ability and diverse material selection,making it a compelling technology in industries and defenses.However,challenges in both macroscale and microscale defects still limit printed component widespread applications.Recent advances in automatic and intelligent technologies have brought a range of quality controllable strategies to the forefront.This review covers these new strategies for the printing component,including path planning,process monitoring,auxiliary processes,and post processing,while discussing the expectation for structure and quality improvement.In addition,the work brings new areas of intelligent wire-arc DED development,including advances in digital twin,visualization,and human-processing interaction to promote its performance.It is anticipated that a focus on intelligent system will be key to smart and high-quality manufacturing for future wire-arc DED.
文摘Objective:to study the effect of automatic tube current modulation on abdominal CT image quality and radiation dose. Methods: a total of 70 patients who underwent abdominal CT examination in our hospital from August 2019 to August 2020 were collected and divided into control group (35 cases) and study group (35 cases) according to the random number table. CT scan was performed in the control group according to the conventional parameters, while CT scan was performed in the research group using automatic tube current modulation technology. The CT image quality and radiation dose of patients in the two groups were compared. Results: the image quality of the study group was better than that of the control group (P < 0.05). When NI ≥8, the radiation dose in the study group was lower than that in the control group (P < 0.05). Conclusion Automatic tube current modulation technique can obtain better image quality in CT detection, and has significant significance in reducing radiation dose. It is worthy of affirmation, praise and application.
基金National Social Science Fund Western Project,“Promoting strategies and realization paths for high-quality energy cooperation under the Belt and Road Initiative”(Grant No.24XGJ002)。
文摘Energy is the bedrock of national economic development and a vital pillar for achieving sustainable growth.High-quality energy cooperation is critical to ensuring sustained,stable national economic development and the transformation of the energy sector.Based on the achievements of high-quality energy cooperation within the Belt and Road Initiative,this paper systematically analyzes the current state of energy cooperation under the Belt and Road Initiative.In accordance with the intrinsic requirements for high-quality energy cooperation,and building upon the analysis and summary of prior research,this paper proposes strategies to promote high-quality energy cooperation within the Belt and Road Initiative:(1)Innovating cooperative concepts and optimizing the cooperative environment;(2)Innovating cooperation modes and expanding the scope of cooperation;(3)Improving the cooperation mechanism and building a multi-level cooperation platform;(4)Strengthening cultural exchanges and promoting dialogue.This paper offers insights and support for fostering high-quality collaboration within the Belt and Road Initiative and enhancing international energy cooperation.
基金supported by the Scientific and Technological Research Council of Turkey(TUBITAK)under Grant No.124E002(1001-Project).
文摘This study addresses the critical challenge of reconfiguration in unbalanced power distribution networks(UPDNs),focusing on the complex 123-Bus test system.Three scenarios are investigated:(1)simultaneous power loss reduction and voltage profile improvement,(2)minimization of voltage and current unbalance indices under various operational cases,and(3)multi-objective optimization using Pareto front analysis to concurrently optimize voltage unbalance index,active power loss,and current unbalance index.Unlike previous research that oftensimplified system components,this work maintains all equipment,including capacitor banks,transformers,and voltage regulators,to ensure realistic results.The study evaluates twelve metaheuristic algorithms to solve the reconfiguration problem(RecPrb)in UPDNs.A comprehensive statistical analysis is conducted to identify the most efficient algorithm for solving the RecPrb in the 123-Bus UPDN,employing multiple performance metrics and comparative techniques.The Artificial Hummingbird Algorithm emerges as the top-performing algorithm and is subsequently applied to address a multi-objective optimization challenge in the 123-Bus UPDN.This research contributes valuable insights for network operators and researchers in selecting suitable algorithms for specific reconfiguration scenarios,advancing the field of UPDN optimization and management.
基金This research was funded by Politeknik Negeri Bandung for funding this research in the 2021 budget year through a grant for applied research,Number B/78.14/PL1.R7/PG.00.03/2021.
文摘Utilization of Micro Hydro Power Plant at the Gunung Halu case study type run-off the river is a household use only in the afternoon,around 5 pm until bedtime at about 10 pm.Therefore,more than 75%of the energy is lost.This case study lost power which can be used as a by-product,such as for drying coffee beans.In this case study,a design was carried out to obtain by-products and improve power quality in the electrical system.In addition,they complain about the poor quality of power controlled by frequency using Triac-Based Electronic Dummy Load Control.The heat from the dummy load in the case study is used as a by-product.MHP with a minimum power of 20 kW,and the usage time of customer service is about 6 h.The energy for the by-products is about 360 kWh/day,and the power quality improved by using Triac-Based Electronic Load Control and Hysteresis Current Control for the active filter.As a result,the power factor is close to one,the generator current harmonics is less than 2%,and the voltage harmonics is less than 5%.
文摘AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-centre study,consecutive patients in sinus rhythm underwent CCTA for suspected coronary artery disease(CAD)using a 320-row detector CT scanner.All patients underwent the standard CT acquisition protocol at our institute(Morriston Hospital)a combination of dose saving advances including prospective electrocardiogram-gating,automated tube current modulation,tube voltage reduction,heart rate reduction,and the most recent novel adaptive iterative dose reconstruction 3D(AIDR3D)algorithm.The cohort comprised real-world patients for routine CCTA who were not selected on age,body mass index,or heart rate.Subjective image quality was graded on a 4-point scale(4=excellent,1=non-diagnostic).RESULTS A total of 543 patients were included in the study with a mean body weight of 81±18 kg and a pre-scan mean heart rate of 70±11 beats per minute(bpm).When indicated,patients received rate-limiting medication with an oral beta-blocker followed by additional intravenous beta-blocker to achieve a heart rate below 65 bpm.The median effective radiation dose was 0.88 mSv(IQR,0.6-1.4 mSv)derived from a Dose Length Product of61.45 mGy.cm(IQR,42.86-100.00 mGy.cm).This also includes what we believe to be the lowest ever-reported radiation dose for a routine clinical CCTA(0.18 mSv).The mean image quality(SD)was 3.65±0.61,with a subjective image quality score of 3("good")or above for 93%of patient CCTAs.CONCLUSION Combining a low-dose scan protocol and AIDR3D with a 320-detector row CT scanner can provide high quality images at exceptionally low radiation dose in unselected patients being investigated for CAD.
基金Item Sponsored by INHA UNIVERSITY Research Grant
文摘Electrochemical polishing is the anodic dissolution process without contact with tools,is a surface treatment method to make a surface planarization using an electrochemical reaction with low applied current.The surface quality is mainly affected by the many process parameters.To improve the surface quality,the control of parameters is very important.The aim of this study is to investigate the characteristic of electrochemical polishing effect for inner diameter of Stainless Steel Tube.In order to analyze the characteristics of surface quality were measured in terms of temperature, applied current and machining time.The investigation can enhance the surface quality of inner diameter Stainless Steel Tube.Therefore,we have verified improved results by using selected optimal conditions.
文摘Based on the monitoring results of environmental quality of the waters near the Feiyun River estuary during 2011-2016, the current situation of environmental quality of the waters was analyzed and evaluated. The results showed that pH, DO, COD Mn , petroleum, and heavy metals (Cu, Pb, Zn, Cd, Hg, As and Cr) in the waters near the Feiyun River estuary did not exceed the second-class standard of Seawater Quality Standard (GB 3097-1997), while both inorganic nitrogen and reactive phosphate in the waters exceeded the second-class standard obviously. The water quality of the waters near the Feiyun River estuary was in an eutrophic state. In terms of sediment quality, the standard index of most evaluation factors except for Cu was smaller than 1, meeting the demands of sediment quality for environmental protection.
文摘Unregulated utilization of renewable generation including residential photovoltaic (PV) systems can have a significant impact on load characteristics in distribution networks. For improving PV generation capabilities, power quality aspects have to be coordinated with present load characteristics. This paper discusses the harmonic content of PV generation and the influence to power quality indicators in residential distribution networks. PV generation measurement results including current harmonic amplitude and phase angle values are presented. Results of different modelling scenarios are analysed and a simplified model of harmonics in PVs is offered. The results of the study showed a moderate additional harmonic distortion in residential load current and voltage distortion at the substation’s busbar when PVs were added. Novelty of the paper is that harmonic current values at higher orders are presented and analysed. The results pointed out in this paper could be further used for modelling the actual harmonic loads of the PVs in distribution networks.
文摘The high utilization level of renewable generation including residential photovoltaic (PV) systems together with the uncontrolled charging of electric vehicles (EVs) can have a significant impact on load characteristics in distribution networks. Harmonic content of PV generation, EV charging loads, and their influence on power quality indicators in residential distribution networks are discussed in this paper. For investigating likely power quality scenarios, PV generation and EV charging measurement results including current harmonic amplitude and phase angle values are used and compared with present load characteristics. Different modelling scenarios are analysed and a simplified model of harmonics in PVs and EVs is offered. The results of the study show moderate additional harmonic distortion in residential load current and voltage distortion at the substation’s busbar when PV generation and EV loading are added. The scenarios presented in this paper can be further used for modelling the actual harmonic loads of the PVs and EVs in distribution networks.
文摘<span style="font-family:Verdana;">Today, energy is a vital component in the functioning of a hospital. Hospital technical facilities have several types of technologies, these include appliances for use;examination apparatus. So, for Quality Health Care in a hospital, there is</span><span style="font-family:Verdana;"> a</span><span style="font-family:Verdana;"> need to ensure the proper functioning of hospital equipment. In addition to the required maintenance as specified by the device manufacturer, </span><span style="font-family:Verdana;">the </span><span style="font-family:Verdana;">quality of the electrical energy across the device must be ensured. This article is an analysis of the quality of electric energy at the substation of National Hospital of Niamey. Thereby, the data collection, followed by the data processing and analysis revealed the parameters characterizing the quality of electrical energy across the substation. Our studies have shown that the substation is underutilized as the maximum inrush current is less than half the available current. </span><span style="font-family:Verdana;">The </span><span style="font-family:Verdana;">current </span><span style="font-family:Verdana;">was </span><span style="font-family:Verdana;">consumed by the three phases ha</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> resulted </span><span style="font-family:Verdana;">in</span><span style="font-family:Verdana;"> a strong current unbalance (230</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">A). However, the current unbalance and the voltage amplitude</span><span style="font-family:Verdana;">,</span><span style="font-family:Verdana;"> are admissible according</span><span style="font-family:Verdana;">ly</span><span style="font-family:Verdana;"> base on EN50160 standard. Furthermore, the harmonics voltages present in this medium </span><span style="font-family:Verdana;">are</span><span style="font-family:Verdana;"> in the accepted range (1.8%) according to IEEE 519 standard. However, the fundamental frequency does not meet the standard, but the difference obtained has no adverse effect.</span>
文摘The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is exposed within the open which suggests they can be vulnerable to lightning strikes, road dwindling, windstorms, and a few engineering activities with the potential of causing different degrees of damage to the electrical equipment. One of the ways to guard the equipment is to deploy switching devices. However, the operations of most of these switching devices produce oscillatory transient in the electrical transmission and distribution systems which result in voltage, current, and frequency fluctuations in the load. This paper investigates the effect of switching devices on power quality and proposes a positive sequence voltage power transient suppression technique that can spontaneously improve the distorted voltage at the instant of capacitor switching using the capacitor line model as a case study. MATLAB/Simulink software was utilized for the analysis on an electrical network model with bus voltages of 69 kV/12.47 kV and 480 V. The results showed that, during switching operations, the positive sequence voltage power detector block produces ripple-free accurate results.