摘要
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.
In this paper, a vector regulating principle of the phase and amplitude control ( PAC ) method for three-phase grid-connected inverters is presented. To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC. The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.
基金
supported by the Shanghai Education Committee Scientific Research Subsidization (Grant No.05AZ30)
the Specialized Research Fund for the Doctoral Program of Higher Education (Grant No. 20060280018)