Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation o...Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method.展开更多
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w...In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.展开更多
同步参考坐标系锁相环是高压直流(high voltage direct current,HVDC)同步触发控制系统中广泛应用的一种窄带宽锁相环,在交流系统故障引起相位跳变情况下,其动态响应缓慢。为增大锁相环的带宽,一种滑动平均滤波器(moving average filter...同步参考坐标系锁相环是高压直流(high voltage direct current,HVDC)同步触发控制系统中广泛应用的一种窄带宽锁相环,在交流系统故障引起相位跳变情况下,其动态响应缓慢。为增大锁相环的带宽,一种滑动平均滤波器(moving average filter,MAF)被前置于锁相环路,然而MAF本身存在响应延迟,制约了锁相环的同步速度。为了缓解响应延迟问题,文中提出一种考虑MAF延时和前馈补偿的HVDC快速锁相环。首先,利用MAF线性暂态特征预测相位变化,并分别针对故障接入和切除引起的相位跳变问题提出不同的补偿策略;接着,利用不变性原理对锁相环路进行前馈补偿,在负反馈控制和前馈补偿共同构成的复合校正控制系统的作用下,锁相环能够在较小PI参数下实现快速响应;最后,将所提快速锁相环在CIGRE HVDC标准模型和三峡—上海直流工程模型中进行仿真验证。结果表明,该快速锁相环能够有效缓解滤波器响应延迟的制约,缩短失锁时间,进而提高高压直流逆变侧抵御换相失败的能力。展开更多
基金supported by National Natural Science Foundation of China (No. 61573303)Natural Science Foundation of Hebei Province (No. E2016203092)
文摘Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method.
基金supported by the Shanghai Education Committee Scientific Research Subsidization (Grant No.05AZ30)the Specialized Research Fund for the Doctoral Program of Higher Education (Grant No. 20060280018)
文摘In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method.
文摘同步参考坐标系锁相环是高压直流(high voltage direct current,HVDC)同步触发控制系统中广泛应用的一种窄带宽锁相环,在交流系统故障引起相位跳变情况下,其动态响应缓慢。为增大锁相环的带宽,一种滑动平均滤波器(moving average filter,MAF)被前置于锁相环路,然而MAF本身存在响应延迟,制约了锁相环的同步速度。为了缓解响应延迟问题,文中提出一种考虑MAF延时和前馈补偿的HVDC快速锁相环。首先,利用MAF线性暂态特征预测相位变化,并分别针对故障接入和切除引起的相位跳变问题提出不同的补偿策略;接着,利用不变性原理对锁相环路进行前馈补偿,在负反馈控制和前馈补偿共同构成的复合校正控制系统的作用下,锁相环能够在较小PI参数下实现快速响应;最后,将所提快速锁相环在CIGRE HVDC标准模型和三峡—上海直流工程模型中进行仿真验证。结果表明,该快速锁相环能够有效缓解滤波器响应延迟的制约,缩短失锁时间,进而提高高压直流逆变侧抵御换相失败的能力。