The utilization of hybrid energy systems has necessitated to address the various Power Quality(PQ)concerns in Distributed Generation(DG)networks.Owing to the emergence of DG networks in recent times,it is envisaged fo...The utilization of hybrid energy systems has necessitated to address the various Power Quality(PQ)concerns in Distributed Generation(DG)networks.Owing to the emergence of DG networks in recent times,it is envisaged for every utility⁃grid⁃tied system to generate and utilize harmonic⁃less electric power.Therefore,the present research critically evaluates the operation of a utility⁃grid coordinated DG system and studies its islanding operation under faulted conditions.To achieve this,an Anti⁃Islanding Protection(AIP)scheme is developed which is capable of controlling the frequency and voltage variations.This scheme is operated by a coordinated operation of multivibrators.Their operation continuously traces the pre⁃defined limits of voltage,reactive,and real power,and matches with their reference values to avoid mismatch.It is revealed that,if the mismatched values of real and reactive power exceeded its threshold value of 0.1 p.u.,then the islanding condition is detected.Especially,the proposed system is assessed in two modes:utility⁃grid and islanding modes.In utility⁃grid mode,reactive power compensation is obtained by the control of voltage and frequency signals.However,in islanding mode,the real power requirement of the connected load is obtained with reduced harmonics under unsymmetrical faulted conditions.Incremental Conductance(IC)based Maximum Power Point Tracking(MPPT)technique ensures the extraction of maximum power under varying and stochastically atmospheric conditions.Simulation results reveal that the AIP scheme promptly disconnects the utility grid from the DG network in the minimum time during dynamic variations in frequency and voltage to prevent islanding.It is justified that there is violation of the considered threshold limits even under the faulted condition.The strategy of the switchgear scheme ensures the minimum detection time of the islanding operation.Total Harmonic Distortion(THD)is 0.26%for grid voltage.It validates according to the IEEE⁃1547 standard which stipulates that the THD of grid voltage must be less than 5%.Overall,satisfactory and accurate results are obtained,which are compared with the IEEE⁃1547 standard for validation.展开更多
The dynamics of network power response play a crucial role in system stability.However,the integration of power electronic equipment leads to amplitude and angular frequency(abbreviated as"frequency")time-va...The dynamics of network power response play a crucial role in system stability.However,the integration of power electronic equipment leads to amplitude and angular frequency(abbreviated as"frequency")time-varying characteristics of the node voltage during dynamic processes.As a result,traditional calcu-lation methods for and characteristics of the power response of the network based on phasor and impe-dance lose their validity.Therefore,this paper undertakes mathematical calculations to reveal the power response of a network under excitation by voltage with time-varying amplitude and frequency(TVAF),relying on the original mathematical relationships and superimposed step response.Then,the multi-timescale characteristics of both the active and reactive power of the network are explored physically.Additionally,this paper reveals a new phenomenon of storing and releasing the active and reactive power of the network.To meet practical engineering requirements,a simplified power expression is presented.Finally,the theoretical analysis is validated through time-domain simulations.展开更多
Countries worldwide are advocating for energy transition initiatives to promote the construction of low-carbon energy systems.The low voltage ride through(LVRT)characteristics of renewable energy units and commutation...Countries worldwide are advocating for energy transition initiatives to promote the construction of low-carbon energy systems.The low voltage ride through(LVRT)characteristics of renewable energy units and commutation failures in line commutated converter high voltage direct current(LCC-HVDC)systems at the receiving end leads to short-term power shortage(STPS),which differs from traditional frequency stability issues.STPS occurs during the generator’s power angle swing phase,before the governor responds,and is on a timescale that is not related to primary frequency regulation.This paper addresses these challenges by examining the impact of LVRT on voltage stability,developing a frequency response model to analyze the mechanism of frequency instability caused by STPS,deriving the impact of STPS on the maximum frequency deviation,and introducing an energy deficiency factor to assess its impact on regional frequency stability.The East China Power Grid is used as a case study,where the energy deficiency factor is calculated to validate the proposed mechanism.STPS is mainly compensated by the rotor kinetic energy of the generators in this region,with minimal impact on other regions.It is concluded that the energy deficiency factor provides an effective explanation for the spatial distribution of the impact of STPS on system frequency.展开更多
This study explores theoretical insights and experimental results on monitoring load-carrying capacity degradation in bridge spans through frequency analysis.Experiments were conducted on real bridge structures,includ...This study explores theoretical insights and experimental results on monitoring load-carrying capacity degradation in bridge spans through frequency analysis.Experiments were conducted on real bridge structures,including the Binh Thuan Bridge,focusing on analyzing the power spectral density(PSD)of vibration signals under random traffic loads.Detailed digital models of various bridge spans with different structural designs and construction periods were developed to ensure diversity.The study utilized PSD to analyze the vibration signals from the bridge spans under various loading conditions,identifying the vibration frequencies and the corresponding response regions.The research correlated the observed frequency changes of PSD with the actual deterioration of the bridges over time,identifying patterns that indicate a reduction in stiffness.Experiments demonstrated that frequency changes,particularly in high-frequency regions,are directly related to a reduction in the stiffness of bridge spans.This supports the hypothesis that natural frequencies can serve as effective indicators of structural damage.Furthermore,the emergence and shift of resonant frequency regions provide valuable insights into the extent of damage in actual bridge spans,highlighting the potential for using changes in resonant frequency regions as a new tool for structural damage detection.展开更多
Energy storage-equipped photovoltaic(PV-storage)systems can meet frequency regulation requirements under various operating conditions,and their coordinated support for grid frequency has become a future trend.To addre...Energy storage-equipped photovoltaic(PV-storage)systems can meet frequency regulation requirements under various operating conditions,and their coordinated support for grid frequency has become a future trend.To address frequency stability issues caused by low inertia and weak damping,this paper proposes a multi-timescale frequency regulation coordinated control strategy for PV-storage integrated systems.First,a self-synchronizing control strategy for grid-connected inverters is designed based on DC voltage dynamics,enabling active inertia support while transmitting frequency variation information.Next,an energy storage inertia support control strategy is developed to enhance the frequency nadir,and an active frequency support control strategy for PV system considering a frequency regulation deadband is proposed,where the deadband value is determined based on the power regulation margin of synchronous generators,allowing the PV-storage system to adaptively switch between inertia support and primary frequency regulation under different disturbance conditions.This approach ensures system frequency stability while fully leveraging the regulation capabilities of heterogeneous resources.Finally,the real-time digital simulation results of the PV-storage integrated system demonstrate that,compared to existing control methods,the proposed strategy effectively reduces the rate of change of frequency and improves the frequency nadir under various disturbance scenarios,verifying its effectiveness.展开更多
With the increasing penetration of renewable energy,the coordination of energy storage with thermal power for frequency regulation has become an effective means to enhance grid frequency security.Addressing the challe...With the increasing penetration of renewable energy,the coordination of energy storage with thermal power for frequency regulation has become an effective means to enhance grid frequency security.Addressing the challenge of improving the frequency regulation performance of a thermal-storage primary frequency regulation system while reducing its associated losses,this paper proposes a multi-dimensional cooperative optimization strategy for the control parameters of a combined thermal-storage system,considering regulation losses.First,the frequency regulation losses of various components within the thermal power unit are quantified,and a calculation method for energy storage regulation loss is proposed,based on Depth of Discharge(DOD)and C-rate.Second,a thermal-storage cooperative control method based on series compensation is developed to improve the system’s frequency regulation performance.Third,targeting system regulation loss cost and regulation output,and considering constraints on output overshoot and system parameters,an improved Particle Swarm Optimization(PSO)algorithm is employed to tune the parameters of the low-pass filter and the series compensator,thereby reducing regulation losses while enhancing performance.Finally,simulation results demonstrate that the total loss cost of the proposed control strategy is comparable to that of a system with only thermal power participation.However,the thermal power loss cost is reduced by 42.16%compared to the thermal-only case,while simultaneously improving system frequency stability.Thus,the proposed strategy effectively balances system frequency stability and economic efficiency.展开更多
The implementation of multifunctional application scenarios for mobile terminal devices has increased the energy density requirements of batteries.Increasing the charging voltage can rapidly increase the specific capa...The implementation of multifunctional application scenarios for mobile terminal devices has increased the energy density requirements of batteries.Increasing the charging voltage can rapidly increase the specific capacity of layered transition metal oxides;however,it also exacerbates the release of lattice oxygen and the contraction of the unit cell.Ternary materials are designed in a secondary particle state to meet the requirements of power battery applications.Therefore,to create ternary materials that can operate under ultrahigh voltages,attention should be given to both surface modification and particle integrity maintenance.By utilizing elemental selenium(Se)with a low melting point,easy sublimation,and multiple variable valence states,deep grain boundary modification was implemented inside the particles.The performance of the cathode material was evaluated through pouch cells,and the improvement mechanism was explored through molecular dynamics simulation calculations.Under the protection of a three-dimensional Se-rich modified layer,LiNi_(1/3)Co_(1/3)Mn_(1/3)O_(2)achieved stable operation at ultrahigh voltages(4.6 V vs.Li/Li^(+));a sacrificial protection mechanism based on the chronic decomposition of the Se-rich layer was proposed to explain the efficacy of Se modification in stabilizing ternary materials.This deep grain boundary modification based on elemental Se provides a new solution for the ultrahigh-voltage operation of transition metal oxides and provides a scientific basis and technical support for solving the interface contact problem of all-solid-state batteries.展开更多
Frequency hopping(FH)communication has good anti-fading,anti-jamming and anti-eavesdropping capabilities,so it is one of the main ways to combat electronic jamming.In order to further improve the anti-jamming capabili...Frequency hopping(FH)communication has good anti-fading,anti-jamming and anti-eavesdropping capabilities,so it is one of the main ways to combat electronic jamming.In order to further improve the anti-jamming capability of FH communication,the parameters such as fixed frequency interval,hopping rate and hopping frequency in conventional FH can be assigned with time-varying characteristics.In order to set appropriate hopping parameters to improve the performance of the system in the electromagnetic environment with various types of jamming,a heuristically accelerated Q-learning(HAQL)method is proposed in this paper.Firstly,a theoretical model for the parameter decision-making of FH system is made,and the key parameters affecting the energy efficiency of the system are analyzed.Secondly,a Q-learning model in complex electromagnetic environment is proposed,which includes setting states,actions and rewards,as well as a HAQL-based decisionmaking algorithm is put forward.Lastly,simulations are carried out under different jamming environments,and simulation results show that the average energy efficiency of HAQL algorithm is higher than that of the SARSA algorithm,the e-greedy QL algorithm and the HQL-OSGM algorithm,respectively.展开更多
The susceptibility of ore particles to electrical breakdown plays a critical role for high voltage pulse(HVP)breakage,yet its quantitative characterization still lacks deep understanding.Two indicators,namely breakdow...The susceptibility of ore particles to electrical breakdown plays a critical role for high voltage pulse(HVP)breakage,yet its quantitative characterization still lacks deep understanding.Two indicators,namely breakdown delay time(T_(d))and breakdown strength(E_(b))were compared,based on analysis on the two breakdown modes namely wavefront mode and post-wave mode.It was found that T_(d) is more suitable to characterize the susceptibility of ore particles to electrical breakdown in HVP breakage than E_(b).A probabilistic model based on the Weibull distribution is developed to describe the relation of breakdown probability to T_(d).Regression analyses were conducted to investigate how operating parameters and particle properties influence Td and size reduction degree of ore particles in HVP breakage.The regressed models demonstrate potential capability to predict metallic minerals content and HVP breakage degree based on operating parameters and particle properties.展开更多
Underwater images often affect the effectiveness of underwater visual tasks due to problems such as light scattering,color distortion,and detail blurring,limiting their application performance.Existing underwater imag...Underwater images often affect the effectiveness of underwater visual tasks due to problems such as light scattering,color distortion,and detail blurring,limiting their application performance.Existing underwater image enhancement methods,although they can improve the image quality to some extent,often lead to problems such as detail loss and edge blurring.To address these problems,we propose FENet,an efficient underwater image enhancement method.FENet first obtains three different scales of images by image downsampling and then transforms them into the frequency domain to extract the low-frequency and high-frequency spectra,respectively.Then,a distance mask and a mean mask are constructed based on the distance and magnitude mean for enhancing the high-frequency part,thus improving the image details and enhancing the effect by suppressing the noise in the low-frequency part.Affected by the light scattering of underwater images and the fact that some details are lost if they are directly reduced to the spatial domain after the frequency domain operation.For this reason,we propose a multi-stage residual feature aggregation module,which focuses on detail extraction and effectively avoids information loss caused by global enhancement.Finally,we combine the edge guidance strategy to further enhance the edge details of the image.Experimental results indicate that FENet outperforms current state-of-the-art underwater image enhancement methods in quantitative and qualitative evaluations on multiple publicly available datasets.展开更多
Dynamic disturbances with various frequencies could trigger different failure modes of deep excavations.Superimposed on this static stress are dynamic disturbances due to various dynamic vibrations,e.g.excavation blas...Dynamic disturbances with various frequencies could trigger different failure modes of deep excavations.Superimposed on this static stress are dynamic disturbances due to various dynamic vibrations,e.g.excavation blasting,blasting,tunnel boring machine(TBM)vibration,rockburst wave,earthquakes.Specifically,these dynamic sources are characterized by a wide range of wave frequencies f,resulting in differences in failure modes.A series of true-triaxial compression tests were conducted on granite to simulate the excavation-induced stress path in three-dimensional(3D)stresses.Subsequently,a dynamic disturbance with various frequencies was applied to a cuboid specimen,to reveal the behavior associated with brittle failure.The dynamic disturbance with frequencies f of 5 Hz,10 Hz,and 40 Hz generates less disturbed energy components in the granite together with higher peak strength.However,dynamic disturbances with f of 20 Hz and 30 Hz resulted in a lower peak strength;the peak strength of the rock increases sp albeit it decreases at first,then increases.This U-shaped phenomenon relates to the natural frequency of the granite under such stress conditions.Different rock lithologies consisting of diverse mineral composition,respond differently to each sensitive resonance frequency.Interestingly,the weak disturbance stress with a high frequency f and low amplitude A increases the ratio of crack damage to peak strength(scd/sp)in the granite.This leads to the inhibition of the expansion of the granite during the dynamic disturbance process.Multiple penetrating tensileeshear cracks appear in the s3-direction as the disturbance frequency f increases.展开更多
This paper presents a programmable frequency scan algorithm based on harmonic balance.The core idea involves treating systems under perturbation as nonlinear time-periodic(NTP)systems.Steady-state harmonics are first ...This paper presents a programmable frequency scan algorithm based on harmonic balance.The core idea involves treating systems under perturbation as nonlinear time-periodic(NTP)systems.Steady-state harmonics are first solved via Newton-Raphson iteration through a set of nonlinear equations,and then input-output variables are selected to estimate the linear transfer function of the original NTP system without perturbations.The applications and insights of the proposed algorithm are discussed,particularly in guiding existing frequency scan algorithms,which are restricted by time-domain signal generation or measurement.This improvement is achieved through linear stability analysis of NTP systems with perturbations.展开更多
In the image fusion field,fusing infrared images(IRIs)and visible images(VIs)excelled is a key area.The differences between IRIs and VIs make it challenging to fuse both types into a high-quality image.Accordingly,eff...In the image fusion field,fusing infrared images(IRIs)and visible images(VIs)excelled is a key area.The differences between IRIs and VIs make it challenging to fuse both types into a high-quality image.Accordingly,efficiently combining the advantages of both images while overcoming their shortcomings is necessary.To handle this challenge,we developed an end-to-end IRI andVI fusionmethod based on frequency decomposition and enhancement.By applying concepts from frequency domain analysis,we used the layering mechanism to better capture the salient thermal targets from the IRIs and the rich textural information from the VIs,respectively,significantly boosting the image fusion quality and effectiveness.In addition,the backbone network combined Restormer Blocks and Dense Blocks;Restormer blocks utilize global attention to extract shallow features.Meanwhile,Dense Blocks ensure the integration between shallow and deep features,thereby avoiding the loss of shallow attributes.Extensive experiments on TNO and MSRS datasets demonstrated that the suggested method achieved state-of-the-art(SOTA)performance in various metrics:Entropy(EN),Mutual Information(MI),Standard Deviation(SD),The Structural Similarity Index Measure(SSIM),Fusion quality(Qabf),MI of the pixel(FMI_(pixel)),and modified Visual Information Fidelity(VIF_(m)).展开更多
This study investigates the frequency-temperature behaviors in AT-cut quartz crystal resonators(QCRs).First,the dispersion relations of an infinite quartz plate are obtained through a semi-analytical finite element(SA...This study investigates the frequency-temperature behaviors in AT-cut quartz crystal resonators(QCRs).First,the dispersion relations of an infinite quartz plate are obtained through a semi-analytical finite element(SAFE)analysis,which explicitly reveals the intrinsic frequency-temperature dependence of different vibration modes.Subsequently,we address practical resonator configurations by examining finite quartz plates,where numerical simulations uncover critical interactions between the operational thickness-shear(TS)mode and coupling modes,i.e.,the flexure(F),face-shear(FS),and extension(E)modes.Through the frequency spectra analysis,we demonstrate that both the plate aspect ratio and thermal variations affect mode-coupling behaviors.Unstable frequency-temperature variations(activity dips)are observed at critical resonator dimensions.Validation through the free-vibration eigen-frequency analysis and forced-vibration admittance characterization confirms the stable or unstable states predicted by the frequency spectra.The established framework not only reveals the origin of temperatureinduced activity dips but also provides the crucial design criteria for suppressing the mode-coupling interference in high-stability resonators.展开更多
This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater pene...This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater penetration,power grids are becoming increasingly vulnerable to cyber threats,potentially leading to frequency instability and widespread disruptions.We model two significant attack vectors:load-altering attacks(LAAs)and false data injection attacks(FDIAs)that corrupt frequency measurements.These are analyzed for their impact on grid frequency stability in both linear and nonlinear LFC models,incorporating generation rate constraints and nonlinear loads.A coordinated attack strategy is presented,combining LAAs and FDIAs to achieve stealthiness by concealing frequency deviations from system operators,thereby maximizing disruption while evading traditional detection.To counteract these threats,we propose an Unknown Input Observer(UIO)-based detection framework for linear and nonlinear LFCs.The UIO is designed using linear matrix inequalities(LMIs)to estimate system states while isolating unknown attack inputs,enabling attack detection through monitoring measurement residuals against a predefined threshold.For mitigation,we leverage BESS capabilities with two adaptive strategies:dynamic mitigation for dynamic LAAs,which tunes BESS parameters to enhance the system’s stability margin and accelerate convergence to equilibrium;and staticmitigation for static LAAs and FDIAs.Simulations show that the UIO achieves high detection accuracy,with residuals exceeding thresholds promptly under coordinated attacks,even in nonlinear models.Mitigation strategies reduce frequency deviations by up to 80%compared to unmitigated cases,restoring stability within seconds.展开更多
The integration of a high proportion of renewable energy introduces significant challenges for the adaptability of traditional fault nature identification methods.To address these challenges,this paper presents a nove...The integration of a high proportion of renewable energy introduces significant challenges for the adaptability of traditional fault nature identification methods.To address these challenges,this paper presents a novel fault nature identification method for renewable energy grid-connected interconnection lines,leveraging wavelet packet decomposition and voltage waveform time-frequency morphology comparison algorithms.First,the paper investigates the harmonic injection mechanism during non-full-phase operation following fault isolation in photovoltaic renewable energy systems,and examines the voltage characteristics of faulted phases in renewable energy scenarios.The analysis reveals that substantial differences exist in both the time and frequency domains of phase voltages before and after the extinction of transient faults,whereas permanent faults do not exhibit such variations.Building on this observation,the paper proposes a voltage time-frequency feature extraction method based on wavelet packet decomposition,wherein low-frequency waveform components are selected to characterize fault features.Subsequently,a fault nature identification method is introduced,based on a voltage waveform time-frequency morphology comparison.By employing a windowing technique to quantify waveform differences before and after arc extinction,this method effectively distinguishes between permanent and transient faults and accurately determines the arc extinction time.Finally,a 220 kV renewable energy grid connection line model is developed using PSCAD for verification.The results demonstrate that the proposed method is highly adaptable across various fault locations,transition resistances,and renewable energy control strategies,and can reliably identify fault nature in renewable energy grid connection scenarios.展开更多
This paper introduces a small perturbation frequency domain thermal analysis model based on the nonlinear dynamics model.The model can be applied to study the high-precision temperature control of thermal systems unde...This paper introduces a small perturbation frequency domain thermal analysis model based on the nonlinear dynamics model.The model can be applied to study the high-precision temperature control of thermal systems under low-frequency complex perturbations.The frequency domain characteristics of the space gravitational wave detection satellite are analyzed,and a multi-channel perturbation structure is established.The effects of three kinds of heat flow perturbations,including external heat flow,power generation power,and waste heat of electronic equipment,on the temperature through five transfer paths are investigated.It has been discovered that the waste heat from electronic equipment inside the satellite has the most noticeable effect on the temperature power spectral density of temperature-sensitive optical loads,serving as the primary factor influencing thermal stability.For complex noise signals,the small perturbation analysis method can decompose the different frequency components or ranges,reducing the problem to linearized analysis and simplifying complex calculations.The results indicate that the temperature power spectral density decreases as signal frequency increases,with low-frequency signals exerting a greater influence on temperature stability.The small perturbation analysis method is a novel and effective method for temperature control of space thermal systems,with high accuracy and stability.展开更多
Accurate estimation of battery health status plays a crucial role in battery management systems.However,the lack of operational data still affects the accuracy of battery state of health(SOH)estimation.For this reason...Accurate estimation of battery health status plays a crucial role in battery management systems.However,the lack of operational data still affects the accuracy of battery state of health(SOH)estimation.For this reason,a SOH estimation method is proposed based on charging data reconstruction combined with image processing.The charging voltage data is used to train the least squares generative adversarial network(LSGAN),which is validated under different levels of missing data.From a visual perspective,the Gram angle field method is applied to convert one-dimensional time series data into image data.This method fully preserves the time series characteristics and nonlinear evolution patterns,which avoids the difficulties and limited expressive power associated with manual feature extraction.At the same time,the Swin Transformer model is introduced to extract global structures and local details from images,enabling better capture of sequence change trends.Combined with the long short-term memory network(LSTM),this enables accurate estimation of battery SOH.Two different types of batteries are used to validate the test.The experimental results show that the proposed method has good estimation accuracy under different training proportions.展开更多
Facing the economic challenges of significant frequency regulation wear and tear on thermal power units and short energy storage lifespan in thermal-energy storage combined systems participating in grid primary freque...Facing the economic challenges of significant frequency regulation wear and tear on thermal power units and short energy storage lifespan in thermal-energy storage combined systems participating in grid primary frequency regulation(PFR),this paper proposes a novel hybrid energy storage system(HESS)control strategy based on Newton-Raphson optimization algorithm(NRBO)-VMD and a fuzzy neural network(FNN)for PFR.In the primary power allocation stage,the high inertia and slow response of thermal power units prevent them from promptly responding to the high-frequency components of PFR signals,leading to increased mechanical stress.To address the distinct response characteristics of thermal units and HESS,an NRBO-VMD based decomposition method for PFR signals is proposed,enabling a flexible system response to grid frequency deviations.Within the HESS,an adaptive coordinated control strategy and a State of Charge(SOC)self-recovery strategy are introduced.These strategies autonomously adjust the virtual inertia and droop coefficients based on the depth of frequency regulation and the real-time SOC.Furthermore,a FNN is constructed to perform secondary refinement of the internal power distribution within the HESS.Finally,simulations under various operational conditions demonstrate that the proposed strategy effectively mitigates frequent power adjustments of the thermal unit during PFR,adaptively achieves optimal power decomposition and distribution,maintains the flywheel energy storage’s SOC within an optimal range,and ensures the long-term stable operation of the HESS.展开更多
Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication ...Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication infrastructure for LFC increases the risk of being attacked by malicious actors.The dynamic load altering attack(DLAA)is a typical attack that can destabilize the power system,causing the grid frequency to deviate fromits nominal value.Therefore,in this paper,we mathematically analyze the impact of DLAA on the stability of the grid frequency and propose the network parameter regulation(NPR)to mitigate the impact.To begin with,the dynamic LFC model is constructed by highlighting the importance of the network parameter.Then,we model the DLAA and analyze its impact on LFC using the theory of second-order dynamic systems.Finally,we model the NPR and prove its effect in mitigating the DLAA.Besides,we construct a least-effort NPR considering its infrastructure cost and aim to reduce the operation cost.Finally,we carry out extensive simulations to demonstrate the impact of the DLAA and evaluate the mitigation performance of NPR.The proposed cost-benefit NPR approach can not only mitigate the impact of DLAA with 100%and also save 41.18$/MWh in terms of the operation cost.展开更多
文摘The utilization of hybrid energy systems has necessitated to address the various Power Quality(PQ)concerns in Distributed Generation(DG)networks.Owing to the emergence of DG networks in recent times,it is envisaged for every utility⁃grid⁃tied system to generate and utilize harmonic⁃less electric power.Therefore,the present research critically evaluates the operation of a utility⁃grid coordinated DG system and studies its islanding operation under faulted conditions.To achieve this,an Anti⁃Islanding Protection(AIP)scheme is developed which is capable of controlling the frequency and voltage variations.This scheme is operated by a coordinated operation of multivibrators.Their operation continuously traces the pre⁃defined limits of voltage,reactive,and real power,and matches with their reference values to avoid mismatch.It is revealed that,if the mismatched values of real and reactive power exceeded its threshold value of 0.1 p.u.,then the islanding condition is detected.Especially,the proposed system is assessed in two modes:utility⁃grid and islanding modes.In utility⁃grid mode,reactive power compensation is obtained by the control of voltage and frequency signals.However,in islanding mode,the real power requirement of the connected load is obtained with reduced harmonics under unsymmetrical faulted conditions.Incremental Conductance(IC)based Maximum Power Point Tracking(MPPT)technique ensures the extraction of maximum power under varying and stochastically atmospheric conditions.Simulation results reveal that the AIP scheme promptly disconnects the utility grid from the DG network in the minimum time during dynamic variations in frequency and voltage to prevent islanding.It is justified that there is violation of the considered threshold limits even under the faulted condition.The strategy of the switchgear scheme ensures the minimum detection time of the islanding operation.Total Harmonic Distortion(THD)is 0.26%for grid voltage.It validates according to the IEEE⁃1547 standard which stipulates that the THD of grid voltage must be less than 5%.Overall,satisfactory and accurate results are obtained,which are compared with the IEEE⁃1547 standard for validation.
基金supported in part by the National Natural Science Fundation of China(52225704 and 52107096).
文摘The dynamics of network power response play a crucial role in system stability.However,the integration of power electronic equipment leads to amplitude and angular frequency(abbreviated as"frequency")time-varying characteristics of the node voltage during dynamic processes.As a result,traditional calcu-lation methods for and characteristics of the power response of the network based on phasor and impe-dance lose their validity.Therefore,this paper undertakes mathematical calculations to reveal the power response of a network under excitation by voltage with time-varying amplitude and frequency(TVAF),relying on the original mathematical relationships and superimposed step response.Then,the multi-timescale characteristics of both the active and reactive power of the network are explored physically.Additionally,this paper reveals a new phenomenon of storing and releasing the active and reactive power of the network.To meet practical engineering requirements,a simplified power expression is presented.Finally,the theoretical analysis is validated through time-domain simulations.
基金funded by the Technology Project of State Grid Corporation of China(Research on Safety and Stability Evaluation and Optimization Enhancement Technology of Flexible Ultra High Voltage Multiterminal DC System Adapting to the Background of“Sand and Gobi Deserts”),grant number J2024003。
文摘Countries worldwide are advocating for energy transition initiatives to promote the construction of low-carbon energy systems.The low voltage ride through(LVRT)characteristics of renewable energy units and commutation failures in line commutated converter high voltage direct current(LCC-HVDC)systems at the receiving end leads to short-term power shortage(STPS),which differs from traditional frequency stability issues.STPS occurs during the generator’s power angle swing phase,before the governor responds,and is on a timescale that is not related to primary frequency regulation.This paper addresses these challenges by examining the impact of LVRT on voltage stability,developing a frequency response model to analyze the mechanism of frequency instability caused by STPS,deriving the impact of STPS on the maximum frequency deviation,and introducing an energy deficiency factor to assess its impact on regional frequency stability.The East China Power Grid is used as a case study,where the energy deficiency factor is calculated to validate the proposed mechanism.STPS is mainly compensated by the rotor kinetic energy of the generators in this region,with minimal impact on other regions.It is concluded that the energy deficiency factor provides an effective explanation for the spatial distribution of the impact of STPS on system frequency.
文摘This study explores theoretical insights and experimental results on monitoring load-carrying capacity degradation in bridge spans through frequency analysis.Experiments were conducted on real bridge structures,including the Binh Thuan Bridge,focusing on analyzing the power spectral density(PSD)of vibration signals under random traffic loads.Detailed digital models of various bridge spans with different structural designs and construction periods were developed to ensure diversity.The study utilized PSD to analyze the vibration signals from the bridge spans under various loading conditions,identifying the vibration frequencies and the corresponding response regions.The research correlated the observed frequency changes of PSD with the actual deterioration of the bridges over time,identifying patterns that indicate a reduction in stiffness.Experiments demonstrated that frequency changes,particularly in high-frequency regions,are directly related to a reduction in the stiffness of bridge spans.This supports the hypothesis that natural frequencies can serve as effective indicators of structural damage.Furthermore,the emergence and shift of resonant frequency regions provide valuable insights into the extent of damage in actual bridge spans,highlighting the potential for using changes in resonant frequency regions as a new tool for structural damage detection.
基金supported by the State Grid Corporation of China under Grant for Science and Technology Projects(No.SGNXJYOOZWJS2500029).
文摘Energy storage-equipped photovoltaic(PV-storage)systems can meet frequency regulation requirements under various operating conditions,and their coordinated support for grid frequency has become a future trend.To address frequency stability issues caused by low inertia and weak damping,this paper proposes a multi-timescale frequency regulation coordinated control strategy for PV-storage integrated systems.First,a self-synchronizing control strategy for grid-connected inverters is designed based on DC voltage dynamics,enabling active inertia support while transmitting frequency variation information.Next,an energy storage inertia support control strategy is developed to enhance the frequency nadir,and an active frequency support control strategy for PV system considering a frequency regulation deadband is proposed,where the deadband value is determined based on the power regulation margin of synchronous generators,allowing the PV-storage system to adaptively switch between inertia support and primary frequency regulation under different disturbance conditions.This approach ensures system frequency stability while fully leveraging the regulation capabilities of heterogeneous resources.Finally,the real-time digital simulation results of the PV-storage integrated system demonstrate that,compared to existing control methods,the proposed strategy effectively reduces the rate of change of frequency and improves the frequency nadir under various disturbance scenarios,verifying its effectiveness.
基金supported by the Science and Technology Development Project of Jilin Province(Project No.YDZJ202301ZYTS284).
文摘With the increasing penetration of renewable energy,the coordination of energy storage with thermal power for frequency regulation has become an effective means to enhance grid frequency security.Addressing the challenge of improving the frequency regulation performance of a thermal-storage primary frequency regulation system while reducing its associated losses,this paper proposes a multi-dimensional cooperative optimization strategy for the control parameters of a combined thermal-storage system,considering regulation losses.First,the frequency regulation losses of various components within the thermal power unit are quantified,and a calculation method for energy storage regulation loss is proposed,based on Depth of Discharge(DOD)and C-rate.Second,a thermal-storage cooperative control method based on series compensation is developed to improve the system’s frequency regulation performance.Third,targeting system regulation loss cost and regulation output,and considering constraints on output overshoot and system parameters,an improved Particle Swarm Optimization(PSO)algorithm is employed to tune the parameters of the low-pass filter and the series compensator,thereby reducing regulation losses while enhancing performance.Finally,simulation results demonstrate that the total loss cost of the proposed control strategy is comparable to that of a system with only thermal power participation.However,the thermal power loss cost is reduced by 42.16%compared to the thermal-only case,while simultaneously improving system frequency stability.Thus,the proposed strategy effectively balances system frequency stability and economic efficiency.
基金supported by the National Natural Science Foundation of China (52302259)the China Postdoctoral Science Foundation (CPSF) under Grant Number 2023M741479+4 种基金the Postdoctoral Fellowship Program of CPSF under Grant Number GZB20240280the Jiangxi Provincial Natural Science Foundation (20224ACB218006)the financial support from High-level Talent Research Special Funds of Jiangxi University of Science and Technology (Grant No. 205200100670)the Jiangxi Provincial Key Laboratory of Power Energy Storage Batteries and Materials (2024SSY10011)the Major Scientific and Technological Research R&D Special Project of Jiangxi Province(20244AFI92002)
文摘The implementation of multifunctional application scenarios for mobile terminal devices has increased the energy density requirements of batteries.Increasing the charging voltage can rapidly increase the specific capacity of layered transition metal oxides;however,it also exacerbates the release of lattice oxygen and the contraction of the unit cell.Ternary materials are designed in a secondary particle state to meet the requirements of power battery applications.Therefore,to create ternary materials that can operate under ultrahigh voltages,attention should be given to both surface modification and particle integrity maintenance.By utilizing elemental selenium(Se)with a low melting point,easy sublimation,and multiple variable valence states,deep grain boundary modification was implemented inside the particles.The performance of the cathode material was evaluated through pouch cells,and the improvement mechanism was explored through molecular dynamics simulation calculations.Under the protection of a three-dimensional Se-rich modified layer,LiNi_(1/3)Co_(1/3)Mn_(1/3)O_(2)achieved stable operation at ultrahigh voltages(4.6 V vs.Li/Li^(+));a sacrificial protection mechanism based on the chronic decomposition of the Se-rich layer was proposed to explain the efficacy of Se modification in stabilizing ternary materials.This deep grain boundary modification based on elemental Se provides a new solution for the ultrahigh-voltage operation of transition metal oxides and provides a scientific basis and technical support for solving the interface contact problem of all-solid-state batteries.
基金State Key Program of National Natural Science of China under grant nos.U19B2016。
文摘Frequency hopping(FH)communication has good anti-fading,anti-jamming and anti-eavesdropping capabilities,so it is one of the main ways to combat electronic jamming.In order to further improve the anti-jamming capability of FH communication,the parameters such as fixed frequency interval,hopping rate and hopping frequency in conventional FH can be assigned with time-varying characteristics.In order to set appropriate hopping parameters to improve the performance of the system in the electromagnetic environment with various types of jamming,a heuristically accelerated Q-learning(HAQL)method is proposed in this paper.Firstly,a theoretical model for the parameter decision-making of FH system is made,and the key parameters affecting the energy efficiency of the system are analyzed.Secondly,a Q-learning model in complex electromagnetic environment is proposed,which includes setting states,actions and rewards,as well as a HAQL-based decisionmaking algorithm is put forward.Lastly,simulations are carried out under different jamming environments,and simulation results show that the average energy efficiency of HAQL algorithm is higher than that of the SARSA algorithm,the e-greedy QL algorithm and the HQL-OSGM algorithm,respectively.
基金The financial supports from National Natural Science Foundation of China(Nos.52574313,52204272 and 52074091)to this project。
文摘The susceptibility of ore particles to electrical breakdown plays a critical role for high voltage pulse(HVP)breakage,yet its quantitative characterization still lacks deep understanding.Two indicators,namely breakdown delay time(T_(d))and breakdown strength(E_(b))were compared,based on analysis on the two breakdown modes namely wavefront mode and post-wave mode.It was found that T_(d) is more suitable to characterize the susceptibility of ore particles to electrical breakdown in HVP breakage than E_(b).A probabilistic model based on the Weibull distribution is developed to describe the relation of breakdown probability to T_(d).Regression analyses were conducted to investigate how operating parameters and particle properties influence Td and size reduction degree of ore particles in HVP breakage.The regressed models demonstrate potential capability to predict metallic minerals content and HVP breakage degree based on operating parameters and particle properties.
基金supported in part by the National Natural Science Foundation of China[Grant number 62471075]the Major Science and Technology Project Grant of the Chongqing Municipal Education Commission[Grant number KJZD-M202301901].
文摘Underwater images often affect the effectiveness of underwater visual tasks due to problems such as light scattering,color distortion,and detail blurring,limiting their application performance.Existing underwater image enhancement methods,although they can improve the image quality to some extent,often lead to problems such as detail loss and edge blurring.To address these problems,we propose FENet,an efficient underwater image enhancement method.FENet first obtains three different scales of images by image downsampling and then transforms them into the frequency domain to extract the low-frequency and high-frequency spectra,respectively.Then,a distance mask and a mean mask are constructed based on the distance and magnitude mean for enhancing the high-frequency part,thus improving the image details and enhancing the effect by suppressing the noise in the low-frequency part.Affected by the light scattering of underwater images and the fact that some details are lost if they are directly reduced to the spatial domain after the frequency domain operation.For this reason,we propose a multi-stage residual feature aggregation module,which focuses on detail extraction and effectively avoids information loss caused by global enhancement.Finally,we combine the edge guidance strategy to further enhance the edge details of the image.Experimental results indicate that FENet outperforms current state-of-the-art underwater image enhancement methods in quantitative and qualitative evaluations on multiple publicly available datasets.
基金supported by the National Natural Science Foundation of China(Grant Nos.52222810 and 52178383).
文摘Dynamic disturbances with various frequencies could trigger different failure modes of deep excavations.Superimposed on this static stress are dynamic disturbances due to various dynamic vibrations,e.g.excavation blasting,blasting,tunnel boring machine(TBM)vibration,rockburst wave,earthquakes.Specifically,these dynamic sources are characterized by a wide range of wave frequencies f,resulting in differences in failure modes.A series of true-triaxial compression tests were conducted on granite to simulate the excavation-induced stress path in three-dimensional(3D)stresses.Subsequently,a dynamic disturbance with various frequencies was applied to a cuboid specimen,to reveal the behavior associated with brittle failure.The dynamic disturbance with frequencies f of 5 Hz,10 Hz,and 40 Hz generates less disturbed energy components in the granite together with higher peak strength.However,dynamic disturbances with f of 20 Hz and 30 Hz resulted in a lower peak strength;the peak strength of the rock increases sp albeit it decreases at first,then increases.This U-shaped phenomenon relates to the natural frequency of the granite under such stress conditions.Different rock lithologies consisting of diverse mineral composition,respond differently to each sensitive resonance frequency.Interestingly,the weak disturbance stress with a high frequency f and low amplitude A increases the ratio of crack damage to peak strength(scd/sp)in the granite.This leads to the inhibition of the expansion of the granite during the dynamic disturbance process.Multiple penetrating tensileeshear cracks appear in the s3-direction as the disturbance frequency f increases.
基金supported by China Southern Power Grid Corporation(036000KC23090005(GDKJXM20231027)).
文摘This paper presents a programmable frequency scan algorithm based on harmonic balance.The core idea involves treating systems under perturbation as nonlinear time-periodic(NTP)systems.Steady-state harmonics are first solved via Newton-Raphson iteration through a set of nonlinear equations,and then input-output variables are selected to estimate the linear transfer function of the original NTP system without perturbations.The applications and insights of the proposed algorithm are discussed,particularly in guiding existing frequency scan algorithms,which are restricted by time-domain signal generation or measurement.This improvement is achieved through linear stability analysis of NTP systems with perturbations.
基金funded by Anhui Province University Key Science and Technology Project(2024AH053415)Anhui Province University Major Science and Technology Project(2024AH040229)+3 种基金Talent Research Initiation Fund Project of Tongling University(2024tlxyrc019)Tongling University School-Level Scientific Research Project(2024tlxyptZD07)TheUniversity Synergy Innovation Programof Anhui Province(GXXT-2023-050)Tongling City Science and Technology Major Special Project(Unveiling and Commanding Model)(200401JB004).
文摘In the image fusion field,fusing infrared images(IRIs)and visible images(VIs)excelled is a key area.The differences between IRIs and VIs make it challenging to fuse both types into a high-quality image.Accordingly,efficiently combining the advantages of both images while overcoming their shortcomings is necessary.To handle this challenge,we developed an end-to-end IRI andVI fusionmethod based on frequency decomposition and enhancement.By applying concepts from frequency domain analysis,we used the layering mechanism to better capture the salient thermal targets from the IRIs and the rich textural information from the VIs,respectively,significantly boosting the image fusion quality and effectiveness.In addition,the backbone network combined Restormer Blocks and Dense Blocks;Restormer blocks utilize global attention to extract shallow features.Meanwhile,Dense Blocks ensure the integration between shallow and deep features,thereby avoiding the loss of shallow attributes.Extensive experiments on TNO and MSRS datasets demonstrated that the suggested method achieved state-of-the-art(SOTA)performance in various metrics:Entropy(EN),Mutual Information(MI),Standard Deviation(SD),The Structural Similarity Index Measure(SSIM),Fusion quality(Qabf),MI of the pixel(FMI_(pixel)),and modified Visual Information Fidelity(VIF_(m)).
基金Project supported by the National Key Research and Development Program of China(No.2023YFE0111000)the National Natural Science Foundation of China(Nos.12102183,12172171,and U24A2005)the Shenzhen Science and Technology Program of China(No.JCYJ20230807142004009)。
文摘This study investigates the frequency-temperature behaviors in AT-cut quartz crystal resonators(QCRs).First,the dispersion relations of an infinite quartz plate are obtained through a semi-analytical finite element(SAFE)analysis,which explicitly reveals the intrinsic frequency-temperature dependence of different vibration modes.Subsequently,we address practical resonator configurations by examining finite quartz plates,where numerical simulations uncover critical interactions between the operational thickness-shear(TS)mode and coupling modes,i.e.,the flexure(F),face-shear(FS),and extension(E)modes.Through the frequency spectra analysis,we demonstrate that both the plate aspect ratio and thermal variations affect mode-coupling behaviors.Unstable frequency-temperature variations(activity dips)are observed at critical resonator dimensions.Validation through the free-vibration eigen-frequency analysis and forced-vibration admittance characterization confirms the stable or unstable states predicted by the frequency spectra.The established framework not only reveals the origin of temperatureinduced activity dips but also provides the crucial design criteria for suppressing the mode-coupling interference in high-stability resonators.
基金supported by the Natural Science Foundation of China No.62303126the project Major Scientific and Technological Special Project of Guizhou Province([2024]014).
文摘This paper investigates the detection and mitigation of coordinated cyberattacks on Load Frequency Control(LFC)systems integrated with Battery Energy Storage Systems(BESS).As renewable energy sources gain greater penetration,power grids are becoming increasingly vulnerable to cyber threats,potentially leading to frequency instability and widespread disruptions.We model two significant attack vectors:load-altering attacks(LAAs)and false data injection attacks(FDIAs)that corrupt frequency measurements.These are analyzed for their impact on grid frequency stability in both linear and nonlinear LFC models,incorporating generation rate constraints and nonlinear loads.A coordinated attack strategy is presented,combining LAAs and FDIAs to achieve stealthiness by concealing frequency deviations from system operators,thereby maximizing disruption while evading traditional detection.To counteract these threats,we propose an Unknown Input Observer(UIO)-based detection framework for linear and nonlinear LFCs.The UIO is designed using linear matrix inequalities(LMIs)to estimate system states while isolating unknown attack inputs,enabling attack detection through monitoring measurement residuals against a predefined threshold.For mitigation,we leverage BESS capabilities with two adaptive strategies:dynamic mitigation for dynamic LAAs,which tunes BESS parameters to enhance the system’s stability margin and accelerate convergence to equilibrium;and staticmitigation for static LAAs and FDIAs.Simulations show that the UIO achieves high detection accuracy,with residuals exceeding thresholds promptly under coordinated attacks,even in nonlinear models.Mitigation strategies reduce frequency deviations by up to 80%compared to unmitigated cases,restoring stability within seconds.
基金supported by State Grid Sichuan Electric Power Company science and technology project“Research on Key Technologies for Reclosing of High-Ratio New Energy Grid Connection Lines.”(Program No:52199723002Q).
文摘The integration of a high proportion of renewable energy introduces significant challenges for the adaptability of traditional fault nature identification methods.To address these challenges,this paper presents a novel fault nature identification method for renewable energy grid-connected interconnection lines,leveraging wavelet packet decomposition and voltage waveform time-frequency morphology comparison algorithms.First,the paper investigates the harmonic injection mechanism during non-full-phase operation following fault isolation in photovoltaic renewable energy systems,and examines the voltage characteristics of faulted phases in renewable energy scenarios.The analysis reveals that substantial differences exist in both the time and frequency domains of phase voltages before and after the extinction of transient faults,whereas permanent faults do not exhibit such variations.Building on this observation,the paper proposes a voltage time-frequency feature extraction method based on wavelet packet decomposition,wherein low-frequency waveform components are selected to characterize fault features.Subsequently,a fault nature identification method is introduced,based on a voltage waveform time-frequency morphology comparison.By employing a windowing technique to quantify waveform differences before and after arc extinction,this method effectively distinguishes between permanent and transient faults and accurately determines the arc extinction time.Finally,a 220 kV renewable energy grid connection line model is developed using PSCAD for verification.The results demonstrate that the proposed method is highly adaptable across various fault locations,transition resistances,and renewable energy control strategies,and can reliably identify fault nature in renewable energy grid connection scenarios.
基金supported by the National Key Research and Development Program of China(No.2022YFC2204400)。
文摘This paper introduces a small perturbation frequency domain thermal analysis model based on the nonlinear dynamics model.The model can be applied to study the high-precision temperature control of thermal systems under low-frequency complex perturbations.The frequency domain characteristics of the space gravitational wave detection satellite are analyzed,and a multi-channel perturbation structure is established.The effects of three kinds of heat flow perturbations,including external heat flow,power generation power,and waste heat of electronic equipment,on the temperature through five transfer paths are investigated.It has been discovered that the waste heat from electronic equipment inside the satellite has the most noticeable effect on the temperature power spectral density of temperature-sensitive optical loads,serving as the primary factor influencing thermal stability.For complex noise signals,the small perturbation analysis method can decompose the different frequency components or ranges,reducing the problem to linearized analysis and simplifying complex calculations.The results indicate that the temperature power spectral density decreases as signal frequency increases,with low-frequency signals exerting a greater influence on temperature stability.The small perturbation analysis method is a novel and effective method for temperature control of space thermal systems,with high accuracy and stability.
基金supported in part by the National Natural Science Foundation of China(under Grant 62473309,62203352)the Shaanxi Outstanding Youth Science Fund Project(under Grant 2024JC-JCQN-68)+1 种基金the Xi’an Science and Technology Plan Project(under Grant 24GXFW0050)the Xi’an Key Laboratory(under Grant 24ZDSY0015).
文摘Accurate estimation of battery health status plays a crucial role in battery management systems.However,the lack of operational data still affects the accuracy of battery state of health(SOH)estimation.For this reason,a SOH estimation method is proposed based on charging data reconstruction combined with image processing.The charging voltage data is used to train the least squares generative adversarial network(LSGAN),which is validated under different levels of missing data.From a visual perspective,the Gram angle field method is applied to convert one-dimensional time series data into image data.This method fully preserves the time series characteristics and nonlinear evolution patterns,which avoids the difficulties and limited expressive power associated with manual feature extraction.At the same time,the Swin Transformer model is introduced to extract global structures and local details from images,enabling better capture of sequence change trends.Combined with the long short-term memory network(LSTM),this enables accurate estimation of battery SOH.Two different types of batteries are used to validate the test.The experimental results show that the proposed method has good estimation accuracy under different training proportions.
基金supported by the Lanzhou Science and Technology Plan Project(XM1753694781389).
文摘Facing the economic challenges of significant frequency regulation wear and tear on thermal power units and short energy storage lifespan in thermal-energy storage combined systems participating in grid primary frequency regulation(PFR),this paper proposes a novel hybrid energy storage system(HESS)control strategy based on Newton-Raphson optimization algorithm(NRBO)-VMD and a fuzzy neural network(FNN)for PFR.In the primary power allocation stage,the high inertia and slow response of thermal power units prevent them from promptly responding to the high-frequency components of PFR signals,leading to increased mechanical stress.To address the distinct response characteristics of thermal units and HESS,an NRBO-VMD based decomposition method for PFR signals is proposed,enabling a flexible system response to grid frequency deviations.Within the HESS,an adaptive coordinated control strategy and a State of Charge(SOC)self-recovery strategy are introduced.These strategies autonomously adjust the virtual inertia and droop coefficients based on the depth of frequency regulation and the real-time SOC.Furthermore,a FNN is constructed to perform secondary refinement of the internal power distribution within the HESS.Finally,simulations under various operational conditions demonstrate that the proposed strategy effectively mitigates frequent power adjustments of the thermal unit during PFR,adaptively achieves optimal power decomposition and distribution,maintains the flywheel energy storage’s SOC within an optimal range,and ensures the long-term stable operation of the HESS.
基金supported by the project Major Scientific and Technological Special Project of Guizhou Province([2024]014).
文摘Load frequency control(LFC)is a critical function to balance the power consumption and generation.Thegrid frequency is a crucial indicator for maintaining balance.However,the widely used information and communication infrastructure for LFC increases the risk of being attacked by malicious actors.The dynamic load altering attack(DLAA)is a typical attack that can destabilize the power system,causing the grid frequency to deviate fromits nominal value.Therefore,in this paper,we mathematically analyze the impact of DLAA on the stability of the grid frequency and propose the network parameter regulation(NPR)to mitigate the impact.To begin with,the dynamic LFC model is constructed by highlighting the importance of the network parameter.Then,we model the DLAA and analyze its impact on LFC using the theory of second-order dynamic systems.Finally,we model the NPR and prove its effect in mitigating the DLAA.Besides,we construct a least-effort NPR considering its infrastructure cost and aim to reduce the operation cost.Finally,we carry out extensive simulations to demonstrate the impact of the DLAA and evaluate the mitigation performance of NPR.The proposed cost-benefit NPR approach can not only mitigate the impact of DLAA with 100%and also save 41.18$/MWh in terms of the operation cost.