Directing to the strong position coupling problem of electro-hydraulic load simulator (EHLS), this article presents an adaptive nonlinear optimal compensation control strategy based on two estimated nonlinear paramete...Directing to the strong position coupling problem of electro-hydraulic load simulator (EHLS), this article presents an adaptive nonlinear optimal compensation control strategy based on two estimated nonlinear parameters, viz. the flow gain coefficient of servo valve and total factors of flow-pressure coefficient. Taking trace error of torque control system to zero as control object, this article designs the adaptive nonlinear optimal compensation control strategy, which regards torque control output of closed-loop controller converging to zero as the control target, to optimize torque tracking performance. Electro-hydraulic load simulator is a typical case of the torque system which is strongly coupled with a hydraulic positioning system. This article firstly builds and analyzes the mathematical models of hydraulic torque and positioning system, then designs an adaptive nonlinear optimal compensation controller, proves the validity of parameters estimation, and shows the comparison data among three control structures with various typical operating conditions, including proportion-integral-derivative (PID) controller only, the velocity synchronizing controller plus P1D controller and the proposed adaptive nonlinear optimal compensation controller plus PID controller. Experimental results show that systems' nonlinear parameters are estimated exactly using the proposed method, and the trace accuracy of the torque system is greatly enhanced by adaptive nonlinear optimal compensation control, and the torque servo system capability against sudden disturbance can be greatly improved.展开更多
This article, in order to precisely impose friction on aircraft and weapon actuation systems, presents a new friction loading method characteristic of "torque-zero velocity" switching control with an electro-hydraul...This article, in order to precisely impose friction on aircraft and weapon actuation systems, presents a new friction loading method characteristic of "torque-zero velocity" switching control with an electro-hydraulic load simulator. As the general Stribeck friction model has little related to static friction, it proposes a "torque-zero velocity" switcher, in which a zero-velocity controller is developed to load the static friction and a torque controller the kinetic friction. With the help of mathematical modeling, this article designs a "torque-zero velocity" switching controller and, correspondingly, provides a "dual-threshold judgment" algorithm. Simulation results indicate that the proposed method can be successfully used to carry out the static and kinetic friction simulation with an electro-hydraulic load simulator.展开更多
This paper studies a nonlinear robust control algorithm of the electro-hydraulic load simulator (EHLS). The tracking performance of the EHLS is mainly limited by the actuator's motion disturbance, flow nonlinearity...This paper studies a nonlinear robust control algorithm of the electro-hydraulic load simulator (EHLS). The tracking performance of the EHLS is mainly limited by the actuator's motion disturbance, flow nonlinearity, and friction, etc. The developed controller is developed based on the nonlinear motion loading model. The problems of the actuator's disturbance and flow nonlinearity are considered. To address the friction problem, the friction model of the loading motor is identified experimentally. The friction disturbance is compensated using the obtained friction model. Therefore, this paper considers the main three factors comprehensively. The developed algorithm is easy to apply since the controller can be obtained just with one step back-stepping design. The stability of the developed algorithm is proven via Lyapunov analysis. Both co-simulation and experiments are performed to verify the effectiveness of this method.展开更多
This paper investigates motion coupling disturbance(the so called surplus torque)in the hardware-in-the-loop(HIL)experiments.The''velocity synchronization scheme''was proposed by Jiao for an electro-hydraulic ...This paper investigates motion coupling disturbance(the so called surplus torque)in the hardware-in-the-loop(HIL)experiments.The''velocity synchronization scheme''was proposed by Jiao for an electro-hydraulic load simulator(EHLS)in 2004.In some situations,however,the scheme is limited in the implementation for certain reasons,as is the case when the actuator's valve signal is not available or it is seriously polluted by noise.To solve these problems,a''dual-loop scheme''is developed for EHLS.The dual-loop scheme is a combination of a torque loop and a position synchronization loop.The role of the position synchronization loop is to decouple the motion disturbance caused by the actuator system.To verify the feasibility and effectiveness of the proposed scheme,extensive simulations are performed using AMESim.Then,the performance of the developed method is validated by experiments.展开更多
Load simulator is a key test equipment for aircraft actuation systems in hardware-in-the-loop-simulation. Static loading is an essential function of the load simulator and widely used in the static/dynamic stiffness t...Load simulator is a key test equipment for aircraft actuation systems in hardware-in-the-loop-simulation. Static loading is an essential function of the load simulator and widely used in the static/dynamic stiffness test of aircraft actuation systems. The tracking performance of the static loading is studied in this paper. Firstly, the nonlinear mathematical models of the hydraulic load simulator are derived, and the feedback linearization method is employed to construct a feed-forward controller to improve the force tracking performance. Considering the effect of the friction, a LuGre model based friction compensation is synthesized, in which the unmeasurable state is estimated by a dual state observer via a controlled learning mechanism to guarantee that the estimation is bounded. The modeling errors are attenuated by a well-designed robust controller with a control accuracy measured by a design parameter. Employing the dual state observer is to capture the different effects of the unmeasured state and hence can improve the friction compensation accuracy. The tracking performance is summarized by a derived theorem. Experimental results are also obtained to verify the high performance nature of the proposed control strategy.展开更多
Current high power load simulators are generally incapable of obtaining both high loading performance and high energy efficiency. Simulators with high energy efficiency are used to simulate static-state load, and thos...Current high power load simulators are generally incapable of obtaining both high loading performance and high energy efficiency. Simulators with high energy efficiency are used to simulate static-state load, and those with high dynamic performance typically have low energy efficiency. In this paper, the variants of secondary control(VSC) with power recovery are developed to solve this problem for loading hydraulic driving devices that operate under variable pressure, unlike classical secondary control(CSC) that operates in constant pressure network. Hydrostatic secondary control units are used as the loading components, by which the absorbed mechanical power from the tested device is converted into hydraulic power and then fed back into the tested system through 4 types of feedback passages(FPs). The loading subsystem can operate in constant pressure network, controlled variable pressure network, or the same variable pressure network as that of the tested device by using different FPs. The 4 types of systems are defined, and their key techniques are analyzed, including work principle, simulating the work state of original tested device, static operation points, loading performance, energy efficiency, and control strategy, etc. The important technical merits of the 4 schemes are compared, and 3 of the schemes are selected, designed, simulated using AMESim and evaluated. The researching results show that the investigated systems can simulate the given loads effectively, realize the work conditions of the tested device, and furthermore attain a high power recovery efficiency that ranges from 0.54 to 0.85, even though the 3 schemes have different loading performances and energy efficiencies. This paper proposes several loading schemes that can achieve both high dynamic performance and high power recovery efficiency.展开更多
中压设备是列车上较大功率的设备,这些设备分散在列车各系统中,由辅助供电系统集中为其供电。由于电感效应,中压设备启动时的峰值电流会对辅助供电系统的安全性和稳定性产生不利影响。为保证列车辅助供电系统稳定、可靠运行,需要有效地...中压设备是列车上较大功率的设备,这些设备分散在列车各系统中,由辅助供电系统集中为其供电。由于电感效应,中压设备启动时的峰值电流会对辅助供电系统的安全性和稳定性产生不利影响。为保证列车辅助供电系统稳定、可靠运行,需要有效地控制中压设备启动时的峰值电流。基于列车控制与管理系统(TCMS,Train Control and Management System)的控制逻辑,研究列车上电自检阶段中压设备错时顺序启动控制方法,列车运行中空调压缩机错时启动控制方法,以及辅助供电系统故障工况下中压设备减载启动控制方法,避免中压负载峰值电流叠加对辅助供电系统造成的不良影响,确保在故障情况下有足够的辅助供电能力。通过实验室仿真测试和运营线上实车试验,初步验证了在辅助供电备用率和启动峰值电流的限制约束下,列车中压设备启动控制方法的有效性。展开更多
基金National Natural Science Foundation of China (50825502)
文摘Directing to the strong position coupling problem of electro-hydraulic load simulator (EHLS), this article presents an adaptive nonlinear optimal compensation control strategy based on two estimated nonlinear parameters, viz. the flow gain coefficient of servo valve and total factors of flow-pressure coefficient. Taking trace error of torque control system to zero as control object, this article designs the adaptive nonlinear optimal compensation control strategy, which regards torque control output of closed-loop controller converging to zero as the control target, to optimize torque tracking performance. Electro-hydraulic load simulator is a typical case of the torque system which is strongly coupled with a hydraulic positioning system. This article firstly builds and analyzes the mathematical models of hydraulic torque and positioning system, then designs an adaptive nonlinear optimal compensation controller, proves the validity of parameters estimation, and shows the comparison data among three control structures with various typical operating conditions, including proportion-integral-derivative (PID) controller only, the velocity synchronizing controller plus P1D controller and the proposed adaptive nonlinear optimal compensation controller plus PID controller. Experimental results show that systems' nonlinear parameters are estimated exactly using the proposed method, and the trace accuracy of the torque system is greatly enhanced by adaptive nonlinear optimal compensation control, and the torque servo system capability against sudden disturbance can be greatly improved.
基金National Natural Science Foundation of China (50825502)
文摘This article, in order to precisely impose friction on aircraft and weapon actuation systems, presents a new friction loading method characteristic of "torque-zero velocity" switching control with an electro-hydraulic load simulator. As the general Stribeck friction model has little related to static friction, it proposes a "torque-zero velocity" switcher, in which a zero-velocity controller is developed to load the static friction and a torque controller the kinetic friction. With the help of mathematical modeling, this article designs a "torque-zero velocity" switching controller and, correspondingly, provides a "dual-threshold judgment" algorithm. Simulation results indicate that the proposed method can be successfully used to carry out the static and kinetic friction simulation with an electro-hydraulic load simulator.
基金supported by the National Key Basic Research Program of China (No. 2014CB046406)the Key Projects of the National Natural Science Foundation of China (No. 51235002)
文摘This paper studies a nonlinear robust control algorithm of the electro-hydraulic load simulator (EHLS). The tracking performance of the EHLS is mainly limited by the actuator's motion disturbance, flow nonlinearity, and friction, etc. The developed controller is developed based on the nonlinear motion loading model. The problems of the actuator's disturbance and flow nonlinearity are considered. To address the friction problem, the friction model of the loading motor is identified experimentally. The friction disturbance is compensated using the obtained friction model. Therefore, this paper considers the main three factors comprehensively. The developed algorithm is easy to apply since the controller can be obtained just with one step back-stepping design. The stability of the developed algorithm is proven via Lyapunov analysis. Both co-simulation and experiments are performed to verify the effectiveness of this method.
基金sponsored by the National Basic Research Program of China (No.2014CB046406)the Key Projects of the National Natural Science Foundation (No.51235002)
文摘This paper investigates motion coupling disturbance(the so called surplus torque)in the hardware-in-the-loop(HIL)experiments.The''velocity synchronization scheme''was proposed by Jiao for an electro-hydraulic load simulator(EHLS)in 2004.In some situations,however,the scheme is limited in the implementation for certain reasons,as is the case when the actuator's valve signal is not available or it is seriously polluted by noise.To solve these problems,a''dual-loop scheme''is developed for EHLS.The dual-loop scheme is a combination of a torque loop and a position synchronization loop.The role of the position synchronization loop is to decouple the motion disturbance caused by the actuator system.To verify the feasibility and effectiveness of the proposed scheme,extensive simulations are performed using AMESim.Then,the performance of the developed method is validated by experiments.
基金National Science Fund for Distinguished Young Scholars (50825502)
文摘Load simulator is a key test equipment for aircraft actuation systems in hardware-in-the-loop-simulation. Static loading is an essential function of the load simulator and widely used in the static/dynamic stiffness test of aircraft actuation systems. The tracking performance of the static loading is studied in this paper. Firstly, the nonlinear mathematical models of the hydraulic load simulator are derived, and the feedback linearization method is employed to construct a feed-forward controller to improve the force tracking performance. Considering the effect of the friction, a LuGre model based friction compensation is synthesized, in which the unmeasurable state is estimated by a dual state observer via a controlled learning mechanism to guarantee that the estimation is bounded. The modeling errors are attenuated by a well-designed robust controller with a control accuracy measured by a design parameter. Employing the dual state observer is to capture the different effects of the unmeasured state and hence can improve the friction compensation accuracy. The tracking performance is summarized by a derived theorem. Experimental results are also obtained to verify the high performance nature of the proposed control strategy.
文摘Current high power load simulators are generally incapable of obtaining both high loading performance and high energy efficiency. Simulators with high energy efficiency are used to simulate static-state load, and those with high dynamic performance typically have low energy efficiency. In this paper, the variants of secondary control(VSC) with power recovery are developed to solve this problem for loading hydraulic driving devices that operate under variable pressure, unlike classical secondary control(CSC) that operates in constant pressure network. Hydrostatic secondary control units are used as the loading components, by which the absorbed mechanical power from the tested device is converted into hydraulic power and then fed back into the tested system through 4 types of feedback passages(FPs). The loading subsystem can operate in constant pressure network, controlled variable pressure network, or the same variable pressure network as that of the tested device by using different FPs. The 4 types of systems are defined, and their key techniques are analyzed, including work principle, simulating the work state of original tested device, static operation points, loading performance, energy efficiency, and control strategy, etc. The important technical merits of the 4 schemes are compared, and 3 of the schemes are selected, designed, simulated using AMESim and evaluated. The researching results show that the investigated systems can simulate the given loads effectively, realize the work conditions of the tested device, and furthermore attain a high power recovery efficiency that ranges from 0.54 to 0.85, even though the 3 schemes have different loading performances and energy efficiencies. This paper proposes several loading schemes that can achieve both high dynamic performance and high power recovery efficiency.
文摘中压设备是列车上较大功率的设备,这些设备分散在列车各系统中,由辅助供电系统集中为其供电。由于电感效应,中压设备启动时的峰值电流会对辅助供电系统的安全性和稳定性产生不利影响。为保证列车辅助供电系统稳定、可靠运行,需要有效地控制中压设备启动时的峰值电流。基于列车控制与管理系统(TCMS,Train Control and Management System)的控制逻辑,研究列车上电自检阶段中压设备错时顺序启动控制方法,列车运行中空调压缩机错时启动控制方法,以及辅助供电系统故障工况下中压设备减载启动控制方法,避免中压负载峰值电流叠加对辅助供电系统造成的不良影响,确保在故障情况下有足够的辅助供电能力。通过实验室仿真测试和运营线上实车试验,初步验证了在辅助供电备用率和启动峰值电流的限制约束下,列车中压设备启动控制方法的有效性。