This study presents the methodology to eliminate oil residual in copper pipe due to rolling process for manufacturing coil used in air conditioner. The pressure caused by Nitrogen flow rate was applied starting from 0...This study presents the methodology to eliminate oil residual in copper pipe due to rolling process for manufacturing coil used in air conditioner. The pressure caused by Nitrogen flow rate was applied starting from 0, 5, 10, and 15 bar, respectively which was depending on time delay and pipe length. The developed system was divided into 2 modules: Parallel pressure ladder module (PPLM) [1] and Serial pressure ladder module (SPLM) which were experimented with 2 sizes of copper pipe: diameter 7.29 mm, thickness 0.25 mm, and length 10 km, and diameter 8 mm, thickness 0.25 mm, and length 10 km. From experiment, it can be noted that PPLM would perform better in elimination of oil residual compared to SPLM. About 97.44% (0.04 mg/m) and 97.59% (0.05 mg/m) of oil residual can be respectively eliminated from diameter 7.29 mm pipe and diameter 8 mm pipe which exceeded the standard allowance of 30% or 0.1 mg/m. Moreover, the cost of Nitrogen can be reduced by 6.25% per month.展开更多
Recently,Hailiang Group’s Southwest copper production base was formally settled in the Jiangjin Luohuang Industrial Park.It’s reported that the project has attracted a total investment of RMB3 billion,covering an ar...Recently,Hailiang Group’s Southwest copper production base was formally settled in the Jiangjin Luohuang Industrial Park.It’s reported that the project has attracted a total investment of RMB3 billion,covering an area of 230 mu with an annual capacity of 90,000-ton copper pipes and60,000-ton copper busbars for air conditioning and refrigeration purposes(3 planned copper pipe production lines for refrigeration purposes,each展开更多
The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × ...The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × 7 mm and vapor and liquid lines with an outside diameter of 3 mm, whose lengths were 145 mm and 175 mm, respectively. The LHP was tested at heat loads from 5 W to 60 W, different orientations in the gravity field and heat-sink temperatures from -40°C to +50°C. It is shown that the LHP retains its efficiency at all testing conditions. It is also mentioned that at a heat-sink temperature of +50°C the device operates in the mode of constant conductivity in the whole range of heat loads, and in this case a minimum thermal resistance of the “heat source-heat sink” system equal to 0.16°C/W is achieved, which is independent of the LHP orientation in the gravity field.展开更多
The quality of micro heat pipe(MHP) is strongly affected by sealing technology. Based on the analysis of requirements of sealing technology, a cold welding technology was presented to seal MHP. In the cold welding pro...The quality of micro heat pipe(MHP) is strongly affected by sealing technology. Based on the analysis of requirements of sealing technology, a cold welding technology was presented to seal MHP. In the cold welding process, compression force was used to flatten micro groove copper(MGC) tube. Then the bonding of MGC tube was reached because of intensively plastic deformation of MGC tube under pressure. It is found that the plastic deformation area of the cold welding of MGC tube can be divided into three sections. The deformation of micro grooves in each section was investigated; the influence of the dimensions of cylindrical heads on the weld joint shape and strength was studied; and a comparison between smooth copper tube and MGC tube was done. The results show that a groove compression stage exists in the cold welding of MGC tube besides a flattened stage and a melting stage.展开更多
Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from ...Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from the mine was used in recreating the in situ conditions.Electric heaters were utilized to raise the temperature inside each pipe to simulate the essential element of the copper extraction process.The maximum vertical deflection reached by the test pipes was close to 20%,when the simulated heap pile height was 80 m.The plastic pipes and the overliner material were also tested in the laboratory.Based on the results,the maximum heap pile fll depth was recommended for the aeration system.The results indicated that the vertical deflection was the primary performance index for the aeration pipes installed in heap piles at mines.Lastly,the pipe made of polypropylene resin was super.展开更多
Objective To assess the health safety of copper, steel and plastic water pipes by field water quality investigations. Methods Four consumers were randomly selected for each type of water pipes. Two consumers of every ...Objective To assess the health safety of copper, steel and plastic water pipes by field water quality investigations. Methods Four consumers were randomly selected for each type of water pipes. Two consumers of every type of the water pipes had used the water pipes for more than 1 year and the other 2 consumers had used the water pipes for less than 3 months. The terminal volume of tap water in copper and steel water pipes should be not less than 0.1 liter, whereas that in plastic water pipes should be not less than 1 liter. Results The mean values of the experimental results in the second field water quality investigation of the copper and steel water pipes met the Sanitary Standards for Drinking Water Quality. The items of water sample of the plastic water pipes met the requirements of the Sanitary Standards for Drinking Water Quality. Conclusion Copper, steel, and plastic pipes can be used as drinking water pipes.展开更多
文摘This study presents the methodology to eliminate oil residual in copper pipe due to rolling process for manufacturing coil used in air conditioner. The pressure caused by Nitrogen flow rate was applied starting from 0, 5, 10, and 15 bar, respectively which was depending on time delay and pipe length. The developed system was divided into 2 modules: Parallel pressure ladder module (PPLM) [1] and Serial pressure ladder module (SPLM) which were experimented with 2 sizes of copper pipe: diameter 7.29 mm, thickness 0.25 mm, and length 10 km, and diameter 8 mm, thickness 0.25 mm, and length 10 km. From experiment, it can be noted that PPLM would perform better in elimination of oil residual compared to SPLM. About 97.44% (0.04 mg/m) and 97.59% (0.05 mg/m) of oil residual can be respectively eliminated from diameter 7.29 mm pipe and diameter 8 mm pipe which exceeded the standard allowance of 30% or 0.1 mg/m. Moreover, the cost of Nitrogen can be reduced by 6.25% per month.
文摘Recently,Hailiang Group’s Southwest copper production base was formally settled in the Jiangjin Luohuang Industrial Park.It’s reported that the project has attracted a total investment of RMB3 billion,covering an area of 230 mu with an annual capacity of 90,000-ton copper pipes and60,000-ton copper busbars for air conditioning and refrigeration purposes(3 planned copper pipe production lines for refrigeration purposes,each
文摘The paper presents the results of development and investigation of a copper miniature loop heat pipe (LHP) with acetone as a working fluid. The device was equipped with a flat evaporator measuring 80 × 42 × 7 mm and vapor and liquid lines with an outside diameter of 3 mm, whose lengths were 145 mm and 175 mm, respectively. The LHP was tested at heat loads from 5 W to 60 W, different orientations in the gravity field and heat-sink temperatures from -40°C to +50°C. It is shown that the LHP retains its efficiency at all testing conditions. It is also mentioned that at a heat-sink temperature of +50°C the device operates in the mode of constant conductivity in the whole range of heat loads, and in this case a minimum thermal resistance of the “heat source-heat sink” system equal to 0.16°C/W is achieved, which is independent of the LHP orientation in the gravity field.
基金Projects(50436010, 50705031) supported by the National Natural Science Foundation of ChinaProjects(07118064, 8151064101000058) supported by the Natural Science Foundation of Guangdong Province, China
文摘The quality of micro heat pipe(MHP) is strongly affected by sealing technology. Based on the analysis of requirements of sealing technology, a cold welding technology was presented to seal MHP. In the cold welding process, compression force was used to flatten micro groove copper(MGC) tube. Then the bonding of MGC tube was reached because of intensively plastic deformation of MGC tube under pressure. It is found that the plastic deformation area of the cold welding of MGC tube can be divided into three sections. The deformation of micro grooves in each section was investigated; the influence of the dimensions of cylindrical heads on the weld joint shape and strength was studied; and a comparison between smooth copper tube and MGC tube was done. The results show that a groove compression stage exists in the cold welding of MGC tube besides a flattened stage and a melting stage.
文摘Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from the mine was used in recreating the in situ conditions.Electric heaters were utilized to raise the temperature inside each pipe to simulate the essential element of the copper extraction process.The maximum vertical deflection reached by the test pipes was close to 20%,when the simulated heap pile height was 80 m.The plastic pipes and the overliner material were also tested in the laboratory.Based on the results,the maximum heap pile fll depth was recommended for the aeration system.The results indicated that the vertical deflection was the primary performance index for the aeration pipes installed in heap piles at mines.Lastly,the pipe made of polypropylene resin was super.
文摘在小径铜管钎焊结构的X射线数字化图像中,由于钎焊缺陷影像的尺寸、形态及对比度差异大,导致缺陷难以实现自动识别.为解决这一问题,通过多尺度特征表示与Biformer注意力机制相结合,提出一种基于TransUNet改进的缺陷分割模型AM-TransUNet.使用结合SimAM注意力机制的Res2Net模块替换基线模型TransUNet编码器部分的ResNet模块,以提升模型的多尺度特征提取能力和对复杂背景下缺陷局部细节特征的捕捉能力;在编码器末端级联Biformer动态稀疏注意力机制,以提高模型的检测速度和对全局信息的捕捉能力.利用构建的小径铜管X射线图像数据集进行缺陷分割试验,研究结果表明,AM-TransUNet模型的准确率、召回率比基线模型分别提高了2.8%和3.2%,HD95比基线模型减少了13.2,检测灵敏度优于径向0.5 mm的未钎透缺陷,AM-TransUNet缺陷分割模型具有更高的可靠性;同时,AM-TransUNet模型的检测速度比基线模型提高了9帧/s,模型参数量减小了66 M.
基金This work was sponsored by the International Copper Association.
文摘Objective To assess the health safety of copper, steel and plastic water pipes by field water quality investigations. Methods Four consumers were randomly selected for each type of water pipes. Two consumers of every type of the water pipes had used the water pipes for more than 1 year and the other 2 consumers had used the water pipes for less than 3 months. The terminal volume of tap water in copper and steel water pipes should be not less than 0.1 liter, whereas that in plastic water pipes should be not less than 1 liter. Results The mean values of the experimental results in the second field water quality investigation of the copper and steel water pipes met the Sanitary Standards for Drinking Water Quality. The items of water sample of the plastic water pipes met the requirements of the Sanitary Standards for Drinking Water Quality. Conclusion Copper, steel, and plastic pipes can be used as drinking water pipes.