期刊文献+
共找到3,098篇文章
< 1 2 155 >
每页显示 20 50 100
双边LCC无线充电系统ZVS参数优化
1
作者 刘春喜 常洪赫 +1 位作者 孙小鹏 李磊 《电子测量与仪器学报》 北大核心 2025年第10期142-152,共11页
为提高双边LCC补偿无线充电系统的效率,提出一种通过优化补偿元件参数使逆变器在恒流、恒压双模式均实现零电压开关(zero-voltage switch, ZVS)的参数优化方法。首先,采用基尔霍夫定理对双边LCC补偿拓扑进行建模,分析系统在零相位角条... 为提高双边LCC补偿无线充电系统的效率,提出一种通过优化补偿元件参数使逆变器在恒流、恒压双模式均实现零电压开关(zero-voltage switch, ZVS)的参数优化方法。首先,采用基尔霍夫定理对双边LCC补偿拓扑进行建模,分析系统在零相位角条件下实现与负载无关的恒流、恒压输出条件;其次,提出一种双模式参数协同优化策略:引入扰动系数,定量分析补偿元件在双模式下参数扰动对系统等效输入阻抗虚部的影响趋势,筛选在双模式均能使等效阻抗呈现弱感性的元件,依据此筛选结果,给出系统在恒流、恒压双模式均实现零电压开关的参数优化方法,从而实现双模式ZVS;最后,搭建双LCC补偿无线充电系统仿真模型与输入电压15 V的实验样机进行验证。结果表明,系统具有与负载无关的恒流、恒压输出能力,优化后系统逆变器在双模式均能实现零电压开关,系统最大效率可达91.31%,较传统单模式参数优化方法效率提升1%~1.1%,验证了所提参数优化方法的有效性。 展开更多
关键词 双边Lcc 无线充电 恒流 恒压 零电压开关 零相位角
原文传递
Dynamics and stabilization of peak current-mode controlled buck converter with constant current load 被引量:3
2
作者 冷敏瑞 周国华 +1 位作者 张凯暾 李振华 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期101-109,共9页
The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on th... The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. 展开更多
关键词 buck converter constant current load discrete iterative map model ramp compensation
原文传递
Low voltage substrate current: a monitor for interface states generation in ultra-thin oxide n-MOSFETs under constant voltage stresses
3
作者 王彦刚 许铭真 谭长华 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第11期3502-3506,共5页
The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is f... The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is found that the low voltage Ib is formed by electrons tunnelling through interface states, and the variations of Ib(△Ib) are proportional to variations of Nit (△Nit). The Nit energy distributions were determined by differentiating Nit(Vg). The results have been compared with that measured by using gate diode technique. 展开更多
关键词 interface states substrate current ultra-thin oxide constant voltage stress
原文传递
Field-induced phase transitions in chiral smectic liquid crystals studied by the constant current method
4
作者 H Dhaouadi R Zgueb +2 位作者 O Riahi F Trabelsi T Othman 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期373-379,共7页
In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied pr... In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied product can be obtained.In this work, we make a slight modification to the measurement principles based on this method. This modification allows the characteristic parameters of ferroelectric liquid crystal to be quantitatively measured. The use of a current square signal highlights a phenomenon of ferroelectric hysteresis with remnant polarization at null field, which points out an effect of memory in this compound. 展开更多
关键词 chiral smectic liquid crystal constant current method ferroelectric polarization dielectric permittivity
原文传递
Numerical Solution of MHD Convection and Mass Transfer Flow of Viscous Incompressible Fluid about an Inclined Plate with Hall Current and Constant Heat Flux
5
作者 Mohammad Wahiduzzaman Runu Biswas +2 位作者 Md. Eaqub Ali Md. Shakhaoath Khan Ifsana Karim 《Journal of Applied Mathematics and Physics》 2015年第12期1688-1709,共22页
The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifest... The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifestation of transverse magnetic field near an inclined vertical permeable flat plate. It is assumed that the induced magnetic field is negligible compared with the imposed magnetic field. The governing boundary layer equations have been transferred into non-similar model by implementing similarity approaches. The physical dimensionless parameter has been set up into the model as Prandtl number, Eckert number, Magnetic parameter, Schmidt number, local Grashof number and local modified Grashof number. The numerical method of Nactsheim-Swigert shooting iteration technique together with Runge-Kutta six order iteration scheme has been used to solve the system of governing non-similar equations. The physical effects of the various parameters on dimensionless primary velocity profile, secondary velocity profile, and temperature and concentration profile are discussed graphically. Moreover, the local skin friction coefficient, the local Nusselt number and Sherwood number are shown in tabular form for various values of the parameters. 展开更多
关键词 MHD HEAT and Mass Transfer HALL current Inclined Plate constant HEAT FLUX
在线阅读 下载PDF
Non-inverting buck-boost DC-DC converter based on constant inductor current control
6
作者 Yao Suyi Jiang Jianguo 《Journal of Southeast University(English Edition)》 EI CAS 2021年第2期171-176,共6页
The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the ... The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the dependence on the external components and device variation and make smooth transition between hysteresis control loop and pulse width modulation(PWM)control loop.The small signal model was deduced for the buck and boost operation mode.The inductor current slope control(ICSC)was proposed to implement the automatic mode transition between buck and boost mode in one switching cycle.The results show that the converter prototype has good dynamic response capability,achieving 94%efficiency and 95%peak efficiency at full 10 A load current. 展开更多
关键词 four switch buck-boost converter inductor current slope control constant inductor current control small signal model
在线阅读 下载PDF
Multi-stage constant current charging strategy considering SOC intervals and voltage thresholds
7
作者 Yu Zhang Si Xu Tiezhou Wu 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期143-153,共11页
Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,w... Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,while shortening the charging time.This in turn affects the safety of the charging process.Furthermore,the higher charging currents are not ideal for shortening the charging time in the later stages of charging.To solve the aforementioned problems,in this study,a multi-stage constant current charging strategy is presented.This strategy can shorten the battery charging time by using the increase in battery temperature during the charging process as a constraint,using a genetic algorithm to calculate the charging current value,and investigating the phased approach to charging.Finally,the charging strategy is experimentally validated at different ambient temperatures and different initial SOCs.The experimental results show that the charging strategy proposed in this paper not only reduces the amount of calculations,but also reduces the temperature rise by up to 46.4%and charging time by up to 4.2%under different operating conditions. 展开更多
关键词 Charging time Battery temperature rise Genetic algorithm Multi-stage constant current charging
在线阅读 下载PDF
Circulating current suppression for ground tied variable frequency to constant frequency converter system in aircraft
8
作者 Wei WEI Ming HUANG +2 位作者 Wenli YAO Weilin LI Xiaobin ZHANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第11期386-397,共12页
This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400... This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400 Hz load in an aircraft with a variable frequency power supply.Due to the requirement of aircraft standards,both grounds of the rectification and inversion stage are tied to the metal frame of the aircraft.With such a tied ground,the DC bus voltage rises greatly,and a large circulating current appears in the casing as the ground,which leads to equipment failure and potential safety hazards.According to the existing methods of circulating current fault suppression,this paper analyzes the causes of the above faults and the harmonic components of circulating current and points out the limitations of the existing methods.Therefore,a Common-Mode(CM)choke-based method is proposed to provide a high impedance in the path of the CM circulating current.By doing so,the circulating current can be suppressed without the additional burden of the hardware and control algorithm,which is quite friendly for quality control of mass-production aircraft.Moreover,a simplified mathematic model of the VFCF converter system is derived to calculate the minimum inductance value reference of the CM choke,which saves the weight of passive devices to the greatest extent.Finally,simulation and experimental results are studied to verify the effectiveness of the proposed method. 展开更多
关键词 Aircraft power supply Circulating current Common mode choke Power supply circuits Variable Speed constant Frequency
原文传递
High Frequency Oscillator Design Using a Single 45 nm CMOS Current Controlled Current Conveyor (CCCII+) with Minimum Passive Components
9
作者 Mohd Yusuf Yasin Bal Gopal 《Circuits and Systems》 2011年第2期53-59,共7页
In the field of analog VLSI design, current conveyors have reasonably established their identity as an important circuit design element. In the literature published during the past few years, numerous application have... In the field of analog VLSI design, current conveyors have reasonably established their identity as an important circuit design element. In the literature published during the past few years, numerous application have been reported which are based on a variety of current conveyors. In this paper, an oscillator circuit has been proposed. This oscillator is designed using a single positive type second generation current controlled current conveyor (CCCII+). A CCCII has parasitic input resistance on it’s current input node. This resistance could be exploited to reduce circuit complexities. Thus in this accord, a novel oscillator circuit is proposed which utilizes the parasitic resistance of the CCCII+ along with a few more passive components. 展开更多
关键词 current Mode (CM) CIRCUIT Applications current CONVEYOR (cc) current Controlled current CONVEYOR (ccC) Applications ccCII OSCILLATOR CIRCUIT SINGLE ccCII+ OSCILLATOR CIRCUIT Low Power OSCILLATOR CIRCUIT
在线阅读 下载PDF
基于LCC/S-LCL/S切换型双向无线充电系统设计
10
作者 夏涛 夏彧飏 +2 位作者 刘海涛 张仰飞 余海涛 《电机与控制学报》 北大核心 2025年第11期155-167,共13页
本文旨在设计一种用于水下探测设备的双向无线充电系统,以提升其在海洋勘探、环境监测等应用中的能源供应效率。该系统采用多弧型磁耦合结构与LCC/S-LCL/S补偿拓扑切换技术,通过复合补偿网络实现能量双向流动控制及恒流/恒压充电模式的... 本文旨在设计一种用于水下探测设备的双向无线充电系统,以提升其在海洋勘探、环境监测等应用中的能源供应效率。该系统采用多弧型磁耦合结构与LCC/S-LCL/S补偿拓扑切换技术,通过复合补偿网络实现能量双向流动控制及恒流/恒压充电模式的自动切换。为了验证性能,搭建实验平台进行测试。结果表明,系统在正向与反向能量传输中均运行稳定,其输出特性与理论及仿真结果高度一致,有效验证了所提方案的正确性。此外,研究定量分析了在空气与海水两种介质中磁耦合器横向错位对系统传输性能的影响。实验结果证明,该系统在不同错位条件下能保持可靠的传输性能。结论表明,本系统成功实现了高效的双向无线能量传输,具备良好的环境适应性,为水下设备持久、稳定的能源供应提供了实用解决方案。 展开更多
关键词 双向无线充电 多弧型 拓扑切换 恒流 恒压 抗错位
在线阅读 下载PDF
An improved analysis method of constant-current charge/discharge curves and its application to nickel hydroxide electrode
11
作者 潘滔 王建明 +3 位作者 陈惠 赵彦琳 肖慧明 张鉴清 《中国有色金属学会会刊:英文版》 CSCD 2003年第2期462-466,共5页
The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/disch... The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/discharge rates and intermittent discharge experiment are discussed. Though the d t /d E ? 獷 plot is affected by many factors, it clearly has intrinsic relation with the nature of active material such as conductivity and thermodynamic potential of active material, which changes with the state of charge. The d t /d E—E plot can also be applied to other electrochemical active materials, especially to those having several phases during charge or discharge. 展开更多
关键词 镍氢电池 电极 分析方法 改进 放电曲线
在线阅读 下载PDF
Constant Ripple Current Control for Switching DC-DC Converter
12
作者 Gwo-Tarng Chern Jenn-Jong Shieh 《Journal of Energy and Power Engineering》 2012年第9期1437-1441,共5页
The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microele... The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microelectronic load applications. This paper proposes a DC-DC converter using variable on-time and variable switching frequency control enhanced constant ripple current control and reduced magnetic components. The proposed converter is realized by making the turn-offtime proportional to the on-time of the converter, according to the input and output voltage, thereby reducing the corresponding current ripple on output voltage in the continuous conduction mode. A Buck DC-DC converter using the proposed control strategy is analyzed in detail, along with some experimental results to show the performance and effectiveness of this converter. 展开更多
关键词 constant ripple current DC-DC converter variable switching frequency continuous conduction mode indirect currentsensor magnetic component.
在线阅读 下载PDF
An Adaptive Response Compensation Technique for the Constant-Current Hot-Wire Anemometer
13
作者 Soe Minn Khine Tomoya Houra Masato Tagawa 《Open Journal of Fluid Dynamics》 2013年第2期95-108,共14页
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we... An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its effectiveness experimentally for hot-wires of 5 μm, 10 μm and 20 μm in diameter. Then, another novel technique based on a two-sensor probe technique—originally developed for the response compensation of fine-wire thermocouples (Tagawa and Ohta 1997;Tagawa et al. 1998)—has been proposed for estimating thermal time-constants of hot-wires to realize the in-situ response compensation of the CCA. To demonstrate the usefulness of the CCA, we have applied the response compensation schemes to multipoint velocity measure- ment of a turbulent wake flow formed behind a circular cylinder by using a CCA probe consisting of 16 hot-wires, which were driven simultaneously by a very simple constant-current circuit. As a result, the proposed response compensation techniques for the CCA work quite successfully and are capable of improving the response speed of the CCA to obtain reliable measurements comparable to those by the commercially-available constant-temperature hot-wire anemometer (CTA). 展开更多
关键词 Flow Measurement HOT-WIRE ANEMOMETER Turbulent Flow constant-current HOT-WIRE ANEMOMETER Response COMPENSATION Frequency Response Time-constant Multipoint Measurement Digital Signal Processing
暂未订购
Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load
14
作者 Said Oucheriah Abul Azad 《Circuits and Systems》 2024年第3期29-43,共15页
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ... The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations. 展开更多
关键词 Boost Converter Robust Sliding Mode Control constant Power Load (CPL) current-Sensorless Control Extended State Observer
在线阅读 下载PDF
LCC-LCC/S自切换恒流-恒压复合型无线电能传输系统 被引量:15
15
作者 杨云虎 贾维娜 +2 位作者 梁大壮 薛建志 李钰 《电工技术学报》 EI CSCD 北大核心 2023年第18期4823-4837,4852,共16页
为了解决蓄电池充电过程中的恒流过充或恒压欠充问题,该文提出一种LCC-LCC/S自切换恒流-恒压复合型无线电能传输系统。通过副边电力开关切换,该系统不仅可实现恒流-恒压输出,且能有效应对蓄电池充电过程中的各种异常工况;另外,在充电完... 为了解决蓄电池充电过程中的恒流过充或恒压欠充问题,该文提出一种LCC-LCC/S自切换恒流-恒压复合型无线电能传输系统。通过副边电力开关切换,该系统不仅可实现恒流-恒压输出,且能有效应对蓄电池充电过程中的各种异常工况;另外,在充电完成负载移除时,该系统能自动进入低功耗待机状态。首先,给出LCC-LCC/S自切换复合拓扑,分析恒压-恒流及零相角(ZPA)特性;其次,分析恒流-恒压切换点并验证其最优性;然后,通过分析充电过程中出现的副边缺失、负载短路、负载断路等异常工况,系统能通过开关切换有效应对以上异常工作情况,并且充电完成负载移除后系统能自动进入低功耗待机状态;接着,通过与目前研究较多的S-SP拓扑的系统特性进行对比,突出了LCC-LCC/S拓扑的优势;最后,搭建仿真和实验平台,实现最大电流为5.03 A、最大电压为48.92 V的高效率输出,验证了所提理论的正确性。 展开更多
关键词 无线电能传输 自切换 恒流-恒压 复合拓扑
在线阅读 下载PDF
基于CCS软件的IIR滤波器实验设计 被引量:3
16
作者 姜恩华 李素文 +2 位作者 窦德召 陈得宝 邵芬 《实验技术与管理》 CAS 北大核心 2015年第8期130-133,共4页
借助CCS软件完成了IIR滤波器实验设计,主要设计工作包括输入序列x(n)设计、求解系统函数H(z)的程序设计和求解常系数差分方程的程序设计。首先,通过输入序列x(n)设计和系统函数H(z)设计,求出x(n)和常系数差分方程的系数;其次,调用递推... 借助CCS软件完成了IIR滤波器实验设计,主要设计工作包括输入序列x(n)设计、求解系统函数H(z)的程序设计和求解常系数差分方程的程序设计。首先,通过输入序列x(n)设计和系统函数H(z)设计,求出x(n)和常系数差分方程的系数;其次,调用递推方法求解常系数差分方程的子程序,计算IIR滤波器的输出序列y(n)。借助time/frequency选单观察y(n)的时域波形和频谱。 展开更多
关键词 IIR滤波器 ccS软件 实验设计 常系数差分方程
在线阅读 下载PDF
基于LCC谐振变换器的锂电池充电电路 被引量:4
17
作者 廖鸿飞 帅定新 龙涛元 《电源技术》 CAS 北大核心 2021年第5期669-672,共4页
针对以LLC谐振变换器为主电路的锂电池充电器开关频率变化范围较大,恒压涓流充电时调节特性差的问题,提出了以电容输出滤波的半桥LCC谐振变换器作为主电路的锂电池充电电源设计方法。分析了电容输出滤波半桥LCC谐振变换器的恒流和恒压... 针对以LLC谐振变换器为主电路的锂电池充电器开关频率变化范围较大,恒压涓流充电时调节特性差的问题,提出了以电容输出滤波的半桥LCC谐振变换器作为主电路的锂电池充电电源设计方法。分析了电容输出滤波半桥LCC谐振变换器的恒流和恒压输出特性以及恒流恒压模式的转换过程,给出了变换器精确的参数设计方法。搭建了160 W的实验样机,实验结果验证了该方法是可行的。恒流模式下,当输出电压在20~80 V变化时,变换器的工作频率变化仅有3.33%,并且通过调节工作频率,可以实现空载恒压输出。变换器的开关管能在全范围内实现软开关,最高效率94.5%。 展开更多
关键词 Lcc谐振变换器 充电 恒流 恒压 效率
在线阅读 下载PDF
感应耦合能量传输系统中双边LCC谐振腔恒流和恒压模式的研究 被引量:27
18
作者 陆江华 朱国荣 +2 位作者 黎文静 李博 姜晶 《中国电机工程学报》 EI CSCD 北大核心 2019年第9期2768-2778,共11页
感应耦合能量传输(inductively coupled power transfer,ICPT)系统中补偿网络能够改善系统特性,目前针对谐振补偿网络的输出电流和电压特性没有一种简单易行的分析模型。首先分析了LC电路、??型电路和T型电路实现与负载无关的恒流或恒... 感应耦合能量传输(inductively coupled power transfer,ICPT)系统中补偿网络能够改善系统特性,目前针对谐振补偿网络的输出电流和电压特性没有一种简单易行的分析模型。首先分析了LC电路、??型电路和T型电路实现与负载无关的恒流或恒压输出的谐振条件,并针对高阶无源谐振网络提出一种建模方法,通过将谐振网络等效成2阶LC网络和多级3阶???型电路或多级3阶T型电路的串联,研究其恒流或恒压输出的物理机理。ICPT系统中双边LCC谐振腔实质上是一个9阶谐振网络,基于所提建模方法,分析双边LCC谐振腔输出电流和电压特性。此外,提出仅切换一次系统工作频率便可以实现系统先恒流再恒压输出的方法,且恒流和恒压模式下系统工作频率均满足SAEJ2954标准要求,分别能实现谐振腔输入电压、电流之间的零相角和原边逆变器MOSFETs的零电压开通。搭建3.3kW电动汽车感应耦合能量传输系统的Matlab仿真平台和实验样机,验证理论分析的正确性和可行性。恒流和恒压模式下实验样机谐振腔的效率分别为92.1%和89.7%。 展开更多
关键词 恒流 恒压 感应耦合能量传输 电动汽车 零相位角 零电压开关
原文传递
一种新颖的高阶全极点CC高通滤波器 被引量:5
19
作者 何怡刚 吴杰 蔡国昌 《科技通报》 1998年第5期326-329,共4页
提出了一种高阶全极点CC高通滤波器的设计方法.用该方法对二~七阶最平坦型Butter-worth高通滤波器进行了设计和PSPICE模拟分析,结果与理论分析吻合,表明本文所提方法的可行性.
关键词 电路理论 有源滤波器 电流传送器 高通滤波器
在线阅读 下载PDF
用于EIT成象系统基于CCⅡ-低通滤波电路设计 被引量:2
20
作者 王超 胡华东 +1 位作者 解涛 王化祥 《电子测量技术》 2001年第2期8-9,共2页
文中阐述用于EIT成像系统的低通滤波电路,该电路采用基于CCⅡ原理的集成芯片AD844,其设计方法为零泛器中间等效转化法。
关键词 成像系统 电阻抗层析成像 低通滤波器 电路设计
在线阅读 下载PDF
上一页 1 2 155 下一页 到第
使用帮助 返回顶部