期刊文献+
共找到2,006篇文章
< 1 2 101 >
每页显示 20 50 100
CFD based extraction column design-Chances and challenges 被引量:2
1
作者 Mark W.Hlawitschka Menwer M.Attarakilh +1 位作者 Samer S.Alzyod Hans-Jorg Bart 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第2期259-263,共5页
This paper shows that one-dimensional (I-D) [and three-dimensional (3-D) computational fluid dynamics (CFD)] simulations can replace the state-of-the-art usage of pseudo-homogeneous dispersion or back mixing mod... This paper shows that one-dimensional (I-D) [and three-dimensional (3-D) computational fluid dynamics (CFD)] simulations can replace the state-of-the-art usage of pseudo-homogeneous dispersion or back mixing models. This is based on standardized lab-scale cell experiments for the determination of droplet rise, breakage, coalescence and mass transfer parameters in addition to a limited number of additional mini-plant experiments with original fluids. Alternatively, the hydrodynamic parameters can also be derived using more sophisticated 3- D CFD simulations. Computational 1-D modeling served as a basis to replace pilot-plant experiments in any column geometry. The combination of 3-D CFD simulations with droplet population balance models (DPBM) increased the accuracy of the hydrodynamic simulations and gave information about the local droplet size. The high computational costs can be reduced by open source CFD codes when using a flexible mesh generation. First combined simulations using a three way coupled CFD/DPBM/mass-transfer solver pave the way for a safer design of industrial-sized columns, where no correlations are available. 展开更多
关键词 CFD DPBM column design
在线阅读 下载PDF
From Single Droplet to Column Design
2
作者 Hans-Jrg Bart 《Tsinghua Science and Technology》 SCIE EI CAS 2006年第2期212-216,共5页
The technique state to design counter-current extraction columns is based on the performance of pilot plant experiments. The modelling is then either with the equilibrium or dispersion model, whereas in the latter the... The technique state to design counter-current extraction columns is based on the performance of pilot plant experiments. The modelling is then either with the equilibrium or dispersion model, whereas in the latter the dispersion coefficient accounts for all hydrodynamic non-idealities. A new approach uses single droplet experiments to obtain the basic laws and functions governing droplet breakage, coalescence, relative velocity, and axial dispersion when using droplet populance balance models (DPBM). The hydrodynamics simulation results show that the mean Sauter diameter, hold-up, and concentration profiles could be well predicted, which promotes the use of DPBM models for further applications in industrial scale. 展开更多
关键词 single droplet column design countercurrent extraction droplet populance balance model
原文传递
Reactive dividing wall column for hydrolysis of methyl acetate:Design and control 被引量:11
3
作者 Lumin Li Lanyi Sun +3 位作者 Delian Yang Wang Zhong Yi Zhu Yuanyu Tian 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第10期1360-1368,共9页
Reactive distillation and dividing wall column distillation are two kinds of effective separation technologies,and their integrated configuration,reactive dividing wall column(RDWC),presents attractive advantages.In t... Reactive distillation and dividing wall column distillation are two kinds of effective separation technologies,and their integrated configuration,reactive dividing wall column(RDWC),presents attractive advantages.In this study,the rigorous simulation of RDWC for methyl acetate hydrolysis is performed,and sensitivity analysis is conducted to obtain the minimum reboiler duty.Then a comparison is made between the conventional process and RDWC process,and it shows that 20.1% energy savings can be achieved by RDWC process.In addition,the dynamic characteristic of RDWC is studied and an effective control strategy is proposed.The simple PI control scheme with three temperature loops can obtain reasonable control performance and maintain products at desired purities.It is proved that this RDWC process is an energy efficiency alternative with good controllability. 展开更多
关键词 Reactive dividing wall column Methyl acetate Hydrolysis design Control
在线阅读 下载PDF
Shortcut Method of Design and Energy-Saving Analysis of Sargent Dividing Wall Column 被引量:1
4
作者 Fang Jing Cheng Xiaomin +2 位作者 Li Xiaochun Xiang Ning Li Chunli 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2018年第4期99-108,共10页
The Sargent dividing wall column can implement four products separation sequences in one column based on Fully Thermally Coupled Distillation Column. The initial design parameters are required for the design optimizat... The Sargent dividing wall column can implement four products separation sequences in one column based on Fully Thermally Coupled Distillation Column. The initial design parameters are required for the design optimization or dynamic control of the Sargent dividing wall column, and in order to make the rigorous simulation of the Sargent dividing wall column more conducive to convergence, a ten column model for complex Sargent column is established in this paper,and the shortcut design method of this model is proposed. The internal minimum vapor and liquid flow are obtained by the Underwood equations and the mass balance method and the V-min method. The separation for a 4-component shortcut mixture of pentane, hexane, heptane and octane was considered, while the initial values of design parameters and the ratio of vapor-liquid distribution of each column were calculated by using the shortcut design method of a ten column model. And by comparing the shortcut calculations with rigorous simulation results, the practicality and reliability of shortcut calculations were verified. The reason for energy saving was analyzed based on back-mixing. A virtual heat exchanger is proposed to make the Sargent dividing wall column more energy efficient. 展开更多
关键词 Sargent dividing WALL column shortcut design method energy SAVING VIRTUAL HEAT EXCHANGERS
在线阅读 下载PDF
Methodology for Design of Reactive Distillation Column and Kinetics for Isoamylene Etherification Catalysed by Amberlyst 35 被引量:1
5
作者 Wu Yanli Li Wenying +1 位作者 Li Qiang Feng Jie 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2016年第4期128-136,共9页
Isoamylene from the Fischer-Tropsch syncrude can be transformed to valuable fuel oxygenate additives through an equilibrium limited etherification reaction with methanol. A reactive distillation process is established... Isoamylene from the Fischer-Tropsch syncrude can be transformed to valuable fuel oxygenate additives through an equilibrium limited etherification reaction with methanol. A reactive distillation process is established to increase isoamylene conversion. Facing the challenge of improving product purity at the same time, an equilibrium stage model based design methodology is proposed and illustrated step-by-step for converting the Fischer-Tropsch C_5 olefins to tert-amyl methyl ether(TAME) process by using Aspen Plus. Under the guide of the proposed methodology, the design leads to a TAME product purity of higher than 95% and an isoamylene conversion of higher than 90%. The etherification kinetics over Amberlyst 35 is also studied within a temperature range of 60 ℃ to 75 ℃ to shed more light on the feasibility of process development. The methodology provides an effective reactive distillation column design to achieve the target reactant conversion and product purity simultaneously. 展开更多
关键词 Amberlyst 35 design methodology etherification isoamylene reactive distillation column
在线阅读 下载PDF
Design of Pilot Plant Packed Column for the Dehydration of Water from Ethanol-Water Mixtures
6
作者 A. O. Okewale P. K. Igbokwe K. A. Babayemi 《Advances in Chemical Engineering and Science》 2015年第2期152-157,共6页
This use of biomass-based adsorbent has been explored for the column study of the adsorptive dehydration of water in ethanol-water mixtures. The column study was carried out using enzyme modified corn starch and the b... This use of biomass-based adsorbent has been explored for the column study of the adsorptive dehydration of water in ethanol-water mixtures. The column study was carried out using enzyme modified corn starch and the breakthrough curve parameters were used to design the packed bed column. The effect of flow rate on the breakthrough curves revealed that adsorption efficiency decreased with increased inflow rate. The empty bed contact time (τ) of the pilot plant packed column was 35.35 min while the breakthrough time is 40.78 min. 66.7% was the fraction of capacity left unused for the pilot plant from the design. 展开更多
关键词 ENZYME Modified CORNSTARCH design Fixed column BREAKTHROUGH Curve DEHYDRATION ETHANOL-WATER Mixtures
在线阅读 下载PDF
Effect of seismic design details on hysteresis performance of SRC-RC transfer columns 被引量:3
7
作者 Wu Kai Zhai Jiangpeng +2 位作者 Xue Jianyang Zhao Hongtie Chen Feng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期117-135,共19页
Four types of seismic design details were tested using 11 transfer column specimens and one comparison specimen of RC under low cyclic reversed loading. Test results show that diagonal cracks control the failure patte... Four types of seismic design details were tested using 11 transfer column specimens and one comparison specimen of RC under low cyclic reversed loading. Test results show that diagonal cracks control the failure pattern and damage occurs mainly in the RC section with weak shear capacity in the transfer columns. There is a large difference in the bearing capacity and ductility of the transfer columns according to the test results, which indicates that the strengthening effect of diverse structural measures is quite different. The section ratio of I-section-encased steel and the axial compression ratio also have a great influence on the bearing capacity and ductility. Although the bearing capacity of transfer columns with additional longitudinal bars and additional X bars is relatively large, they have poor deformation capacity. Setting more stirrups along the columns is the best structural measure to enhance the seismic performance. The studs on the I-sectionencased steel by welding can help to complete the stress transfer between the steel and concrete, and avoid performance degradation of the two materials due to bonding failure. 展开更多
关键词 seismic design details hysteresis performance steel reinforced concrete transfer column energy dissipation
在线阅读 下载PDF
A Short-Cut Design Technique to Batch Distillation Column
8
作者 Wenfeng Hao 《Advances in Chemical Engineering and Science》 2019年第3期263-279,共17页
The effects of equipment parameters of batch distillation column on the yield proportion are discussed and analyzed, the relations between maximal yield proportion and the column equipment parameters are correlated, w... The effects of equipment parameters of batch distillation column on the yield proportion are discussed and analyzed, the relations between maximal yield proportion and the column equipment parameters are correlated, which not only can be used to appraise rationality of the design parameters of the columns being employed and which but also can be used to new batch distillation column design. Under the assistance of the separation difficulty defined in this paper, the minimum number of theoretical plates is determined by the limit loss proportion method given, and further the actual number of theoretical plates and the height for the batch distillation are calculated by using the redundancy coefficient found to complete the whole design of the batch distillation as shown in the computational sample. Research showed that the actual number of theoretical plates and the height of batch distillation column with the column diameter 0.6 m are 17 and 5.1 m in alcohol mixture separation system of the sample proposed. Moreover, the approach can be extended to the design of batch distillation column with a separation system of multi-component liquid mixture after those adjacent components are treated as numerous binary component systems. 展开更多
关键词 design Technique BATCH DISTILLATION column Separation DIFFICULTY REDUNDANCY Coefficient Theoretical Plate
暂未订购
Application of Artificial Neural Networks Based Monte Carlo Simulation in the Expert System Design and Control of Crude Oil Distillation Column of a Nigerian Refinery
9
作者 Lekan T. Popoola Alfred A. Susu 《Advances in Chemical Engineering and Science》 2014年第2期266-283,共18页
This research work investigated comparative studies of expert system design and control of crude oil distillation column (CODC) using artificial neural networks based Monte Carlo (ANNBMC) simulation of random processe... This research work investigated comparative studies of expert system design and control of crude oil distillation column (CODC) using artificial neural networks based Monte Carlo (ANNBMC) simulation of random processes and artificial neural networks (ANN) model which were validated using experimental data obtained from functioning crude oil distillation column of Port-Harcourt Refinery, Nigeria by MATLAB computer program. Ninety percent (90%) of the experimental data sets were used for training while ten percent (10%) were used for testing the networks. The maximum relative errors between the experimental and calculated data obtained from the output variables of the neural network for CODC design were 1.98 error % and 0.57 error % when ANN only and ANNBMC were used respectively while their respective values for the maximum relative error were 0.346 error % and 0.124 error % when they were used for the controller prediction. Larger number of iteration steps of below 2500 and 5000 were required to achieve convergence of less than 10-7?for the training error using ANNBMC for both the design of the CODC and controller respectively while less than 400 and 700 iteration steps were needed to achieve convergence of 10-4?using ANN only. The linear regression analysis performed revealed the minimum and maximum prediction accuracies to be 80.65% and 98.79%;and 98.38% and 99.98% when ANN and ANNBMC were used for the CODC design respectively. Also, the minimum and maximum prediction accuracies were 92.83% and 99.34%;and 98.89% and 99.71% when ANN and ANNBMC were used for the CODC controller respectively as both methodologies have excellent predictions. Hence, artificial neural networks based Monte Carlo simulation is an effective and better tool for the design and control of crude oil distillation column. 展开更多
关键词 NEURON Monte Carlo Simulation CRUDE Oil DISTILLATION column Artificial Neural Networks Architecture REFINERY design Control
暂未订购
Prediction of dispersed phase holdup in pulsed disc and doughnut solvent extraction columns under different mass transfer conditions 被引量:3
10
作者 Yong Wang Kathryn H.Smith +3 位作者 Kathryn Mumford Teobaldo F.Grabin Zheng Li Geoffrey W.Stevens 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第2期226-231,共6页
Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is present... Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is presented. Pulsed disc and doughnut solvent extraction columns (PDDC) have been used for a range of important applications such as ura- nium extraction and nuclear fuel recycling. Although the dispersed phase holdup in a PDDC has been presented by some researchers, there is still the need to develop a robust correlation that can predict the experimental dispersed phase holdup over a range of operating conditions including the effects of mass transfer direction. In this study, dis- persed phase holdup data from different literature sources for a PDDC were used to refit constants for the correlation presented by Kumar and Hartland lind. Eng. Chem. Res.,27 (1988),131-138] which did not consider the effect of col- umn geometry. In order to incorporate the characteristic length of the PDDC (i.e. the plate spacing), the unified cor- relation for holdup proposed by Kumar and Hartland based on data from eight different types of columns [Ind. Eng. Chem. Res.,34 (1995) 3925-3940] was refitted to the PDDC data. New constants have been presented for each hold- up correlation for a PDDC based on regression analysis using published holdup data from PDDCs that cover a range of onerating conditions and nhwical nronerties and consider the direction of mass transfer. 展开更多
关键词 Solvent extraction Liquid extraction Pulsed disc and doughnut columns Solvent extraction column design Holdup Dispersed phase holdup Hydrodynamics of extraction columns
在线阅读 下载PDF
部分包覆钢-混凝土组合柱-墙体防火设计
11
作者 李诗隽 《科学技术创新》 2026年第3期129-132,共4页
本文面向部分包覆钢-混凝土组合结构在住宅等建筑结构中应用,考虑填充墙体对主要PEC柱在火灾热场下的隔热影响,基于数值模拟分析了相关标准中复合防火保护方法的设计可靠性和相应改良方法。研究以ISO-834标准火灾升温曲线为火灾条件,以... 本文面向部分包覆钢-混凝土组合结构在住宅等建筑结构中应用,考虑填充墙体对主要PEC柱在火灾热场下的隔热影响,基于数值模拟分析了相关标准中复合防火保护方法的设计可靠性和相应改良方法。研究以ISO-834标准火灾升温曲线为火灾条件,以非膨胀型防火涂料的导热系数、涂覆厚度、涂覆延伸长度等为关键参数,依据《建筑钢结构防火技术规范》GB51249-2017中临界温度方法,系统分析了不同荷载比下PEC柱截面主钢件的防火效果,以供相关工程参考。 展开更多
关键词 部分包覆钢-混凝土组合柱 防火设计 热传导 极限温度
在线阅读 下载PDF
Application of the dividing wall column to olefin separation in fluidization methanol to propylene(FMTP) process 被引量:1
12
作者 Xiaolong Ge Botong Liu +2 位作者 Xigang Yuan Yiqing Luo Kuo-Ksong Yu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第8期1069-1078,共10页
Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in th... Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in the present work.Detailed design for pilot DWC was performed and five control structures,i.e.composition control(CC),temperature control(TC),composition-temperature control(CC-TC),temperature difference control(TDC),double temperature difference control(DTDC)were proposed to circumvent feed disturbance.Sensitivity analysis and singular value decomposition(SVD)were used as criterion to select the controlled temperature locations in TC,CC-TC,TDC and DTDC control loops.The steady simulation result demonstrates that 25.7% and 30.2% duty can be saved for condenser and reboiler by substituting conventional column sequence with DWC,respectively.As for control structure selection,TC and TDC perform better than other three control schemes with smaller maximum deviation and shorter settling time. 展开更多
关键词 Distillation Dividing wall column Olefin separation Detailed design Process control
在线阅读 下载PDF
Design Optimization of Reinforced Concrete Frames
13
作者 Abobakr A. A. Aga Fathelrahman M. Adam 《Open Journal of Civil Engineering》 2015年第1期74-83,共10页
In this paper, a design optimization for the reinforced concrete plane frame structure has been done in order to minimize the cost of the concrete and steel for beams and columns by adopting the Artificial Neural Netw... In this paper, a design optimization for the reinforced concrete plane frame structure has been done in order to minimize the cost of the concrete and steel for beams and columns by adopting the Artificial Neural Network (ANN) computational model trough the NeuroShell-2 software program. The design procedure conforms to the ACI-318-08 Code. The variables used for design optimization are the width, depth and the area of reinforced steel, including longitudinal reinforcement and shear reinforcement. A three-bay two-story RC frame is modeled with selecting different span length and different load cases. Acceptable design results are obtained from more than 50 examples which are subjected to all the constraints of the ACI Code, using different cross-section sizes and these results are used to train the NeuroShell-2 program. The results obtained demonstrate the efficiency of the ANN procedure for the multi story RC frame design. 展开更多
关键词 OPTIMIZATION design RC BEAM design RC column design Artificial NEURAL NETWORK
暂未订购
Failure mode classification of reinforced concrete column using Fisher method 被引量:12
14
作者 戚永乐 韩小雷 季静 《Journal of Central South University》 SCIE EI CAS 2013年第10期2863-2869,共7页
In order to apply the performance-based seismic design, an engineer must first find out whether the column is expected to fail in shear before or after flexural yielding. According to column failure characteristics an... In order to apply the performance-based seismic design, an engineer must first find out whether the column is expected to fail in shear before or after flexural yielding. According to column failure characteristics and failure mode of reinforced concrete column, the UW-PEER structure performance database was discussed and analyzed. In order to investigate the relevance of failure mode and factors such as longitudinal reinforcement ratio, transverse reinforcement ratio, hoop spacing to depth ratio, aspect ratio, shearing resistance demand to shear capacity ratio and axial load ratio, Fisher's discriminant analysis(FDA) of the above factors was carried out. A discriminant function was developed to identify column failure mode. Results show that three factors, i.e., Vp /Vn, hoop spacing to depth ratio and aspect ratio have important influence on the failure mode. The failure mode has less to do with longitudinal reinforcement ratio, transverse reinforcement ratio and axial load ratio. Through using these three factors and the model proposed, over 85.6% of the original grouped cases were correctly classified. The value of coefficient of Vp /Vn is the largest, which means that discriminant equation is most sensitive to the shearing resistance demand to shear capacity ratio. 展开更多
关键词 Fisher’s DISCRIMINANT analysis(FDA) CONCRETE column FAILURE mode identification performance-based SEISMIC design
在线阅读 下载PDF
Interpreting the dynamic effect of internal heat integration on reactive distillation columns
15
作者 Yang Yuan Liang Zhang +3 位作者 Haisheng Chen Shaofeng Wang Kejin Huang Huan Shao 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第1期89-102,共14页
In this work,the impact of internal heat integration upon process dynamics and controllability by superposing reactive section onto stripping section,relocating feed locations,and redistributing catalyst within the re... In this work,the impact of internal heat integration upon process dynamics and controllability by superposing reactive section onto stripping section,relocating feed locations,and redistributing catalyst within the reactive section is explored based on a hypothetical ideal reactive distillation system containing an exothermic reaction:A + BC + D.Steady state operation analysis and closed-loop controllability evaluation are carried out by comparing the process designs with and without the consideration of internal heat integration.For superposing reactive section onto stripping section,favorable effect is aroused due to its low sensitivities to the changes in operating condition.For ascending the lower feed stage,somewhat detrimental effect occurs because of the accompanied adverse internal heat integration and strong sensitivity to the changes in operating condition.For descending the upper feed stage,serious detrimental effect happens because of the introduced adverse internal heat integration and strong sensitivity to the changes in operating condition.For redistributing catalyst in the reactive section,fairly small negative influence is aroused by the sensitivity to the changes in operating condition.When reinforcing internal heat integration with a combinatorial use of these three strategies,the decent of the upper feed stage should be avoided in process development.Although the conclusions are derived based on the hypothetical ideal reactive distillation column studied,they are considered to be of general significance to the design and operation of other reactive distillation columns. 展开更多
关键词 Reactive distillation column Internal heat integration Process design Process dynamics Process control
在线阅读 下载PDF
Novel predictive tool for accurate estimation of packed column size
16
作者 Alireza Bahadori Hari B.Vuthaluru 《Journal of Natural Gas Chemistry》 EI CAS CSCD 2010年第2期146-150,共5页
Traditionally the majority of fractionation columns in natural gas processing plants were equipped with trays.However an option to trayed columns is to use packing.Packed columns offer a larger surface area per unit v... Traditionally the majority of fractionation columns in natural gas processing plants were equipped with trays.However an option to trayed columns is to use packing.Packed columns offer a larger surface area per unit volume for mass transfer and the continuous gas to liquid contact throughout the column rather than at specific levels (such as in tray columns).For process design purposes,it is essential to estimate the pressure drop for enabling the proper operation of packed columns.In this study,a simple generalized pressure drop correlation (GPDC) which is easier than existing approaches requiring more complicated and longer computations is developed for sizing randomly packed fractionation columns for pressure drops up to 150 mm water per meter of packing.This correlation can be used to estimate pressure drop for a given loading and column diameter.Alternatively,for a given pressure drop the diameter can be determined.The predictions from the proposed correlation have been compared with reported data and found good agreement with average absolute deviation hovering around 4.9%.The proposed predictive tool is superior owing to its accuracy and clear numerical background,wherein the relevant coefficients can be retuned quickly if new and more accurate data are available in the future.This proposed simple-to-use approach can be of immense practical value for the engineers and scientists to have a quick check on the pressure drop in packed columns for a given loading and column diameter.In particular,gas engineers would find the proposed approach can be used very friendly involving no complex expressions with transparent and easy-to-handle calculation steps. 展开更多
关键词 packed columns PACKING pressure drop FLOODING design principles
在线阅读 下载PDF
品牌学术活动助推医学期刊影响力提升的实践与思考——以“沽放共赏”疑难病例沙龙为例
17
作者 刘英佳 刘英虹 《天津科技》 2025年第8期98-102,107,共6页
举办学术会议或活动是科技期刊高质量发展的重要举措之一,学术活动不仅可以促进学术交流和知识传播,还可以提升期刊的学术水平、吸引高质量研究成果,从而有效助推期刊影响力的提升。通过分析《国际医学放射学杂志》“沽放共赏”疑难病... 举办学术会议或活动是科技期刊高质量发展的重要举措之一,学术活动不仅可以促进学术交流和知识传播,还可以提升期刊的学术水平、吸引高质量研究成果,从而有效助推期刊影响力的提升。通过分析《国际医学放射学杂志》“沽放共赏”疑难病例影像读片沙龙线下活动、线上直播、知识传播与成果转化的成效,从品牌建设、栏目策划、专家和作者培养、提升编辑能力等角度探讨期刊影响力提升的具体措施。 展开更多
关键词 医学期刊 学术活动 学术影响力 品牌建设 栏目设计 直播 编辑素养
在线阅读 下载PDF
Box-Behnken Design响应面法优化银杏叶总黄酮柱层析纯化工艺 被引量:4
18
作者 毕艳艳 马庆文 +5 位作者 许辉 刘健 龙瑞 唐伟铭 郭田甜 郝大伟 《山东科学》 CAS 2022年第6期8-15,共8页
为得到质量分数较高的银杏叶总黄酮提取物,在单因素试验基础上,以上样质量浓度、乙醇体积分数、洗脱液接收体积和洗脱流速为考察因素,以银杏叶总黄酮质量分数、收率为考察指标,采用BBD(Box-Behnken Design)响应面法对银杏叶总黄酮柱层... 为得到质量分数较高的银杏叶总黄酮提取物,在单因素试验基础上,以上样质量浓度、乙醇体积分数、洗脱液接收体积和洗脱流速为考察因素,以银杏叶总黄酮质量分数、收率为考察指标,采用BBD(Box-Behnken Design)响应面法对银杏叶总黄酮柱层析纯化工艺进行优化。得到最佳工艺为上样质量浓度3.1 mg/mL,乙醇体积分数71%,洗脱液接收体积2 BV(BV为装柱体积)及洗脱流速2 BV/h。在最佳工艺条件下,完成三批验证实验,银杏叶总黄酮平均质量分数可达到35.77%,收率为93.30%,银杏总内酯质量分数达到《中国药典》标准。利用BBD响应面法优化银杏叶总黄酮柱层析纯化工艺是科学、合理、可行的,可为工业化大生产提供参考。 展开更多
关键词 Box-Behnken design响应面法 大孔树脂 银杏叶总黄酮 柱层析 纯化
暂未订购
武两高速公路凤来大溪河特大桥主桥设计与技术特点
19
作者 陈克坚 王聪 +2 位作者 宋随弟 张超 陈雪峰 《桥梁建设》 北大核心 2025年第5期130-136,共7页
重庆武两高速公路凤来大溪河特大桥主桥采用跨径580 m的上承式钢桁拱桥,桥面距大溪河谷底高差约310 m,具有跨度大、横向刚度较小的特点,设计风速大,地基承载能力相对较低,横风荷载成为桥梁设计的控制因素之一。该桥采用“拱上梁变跨度... 重庆武两高速公路凤来大溪河特大桥主桥采用跨径580 m的上承式钢桁拱桥,桥面距大溪河谷底高差约310 m,具有跨度大、横向刚度较小的特点,设计风速大,地基承载能力相对较低,横风荷载成为桥梁设计的控制因素之一。该桥采用“拱上梁变跨度分联布置+变刚度水平弹性约束支座”体系,更好地协调拱、柱、梁的空间刚度匹配与协同受力。主拱采用递进增强式平行拱圈结构,两榀拱肋为变高度截面设计,中心矢高116 m,拱肋主桁采用N形桁,拱顶桁中心高13.5 m,拱脚桁中心高16 m,主桁弦杆采用内高、内宽相等的箱形截面,拱脚段弦杆截面尺寸增大,上、下弦平联均采用连续K形撑布置,横联采用X形、V形和倒V形撑。两岸拱座均采用轻型组合式拱座结构,有效降低拱座自重引起的基底应力。拱上立柱为钢结构双柱刚架,拱上梁采用相对较轻的钢板-混凝土结合梁,左、右分幅设置。主桥采用拱圈内力主动调节成拱方法,采用缆索吊装、斜拉扣挂方式施工。 展开更多
关键词 拱桥 上承式 钢桁拱 拱肋 拱座 拱上立柱 拱上梁 桥梁设计
在线阅读 下载PDF
HRB600级钢筋混凝土柱偏压性能试验研究 被引量:2
20
作者 陈安英 王兆峰 +3 位作者 完海鹰 刘西洋 邓松 王晨曦 《建筑结构》 北大核心 2025年第2期106-115,共10页
为研究配置HRB600级钢筋混凝土柱的偏压性能,考虑偏心距与配筋率等因素影响,设计制作了6根高为2000mm的HRB600级钢筋C50混凝土柱。采用偏压加载的方式对试验柱进行静力试验,对其破坏形态、挠度曲线、极限承载力、钢筋强度设计值取值及... 为研究配置HRB600级钢筋混凝土柱的偏压性能,考虑偏心距与配筋率等因素影响,设计制作了6根高为2000mm的HRB600级钢筋C50混凝土柱。采用偏压加载的方式对试验柱进行静力试验,对其破坏形态、挠度曲线、极限承载力、钢筋强度设计值取值及裂缝宽度等展开研究,并对HRB600级钢筋混凝土柱纵向受拉、受压钢筋应变数据进行分析。研究成果显示:HRB600级钢筋混凝土偏压柱的受力形式以及破坏模式与普通钢筋混凝土偏压柱并无差异,其极限承载力仍然可以按照《混凝土结构设计规范》(GB 50010—2010)(2015年版)公式进行计算,但限定混凝土相对受压区高度x≥3.2a′s(a′s为受压区纵筋合力点至截面边缘的距离);对于此类偏压柱,建议HRB600级钢筋的屈服强度标准值取600MPa,抗拉强度设计值取520MPa,抗压强度设计值取460MPa;HRB600级钢筋混凝土柱最大裂缝宽度实测值与规范理论计算值在正常使用阶段吻合良好。 展开更多
关键词 HRB600级钢筋 混凝土柱 偏心距 配筋率 偏压性能 强度设计值 承载力
在线阅读 下载PDF