When the cold atom clock operates in microgravity around the near-earth orbit, its performance will be affected by the fluctuation of magnetic field. A strategy is proposed to suppress the fluctuation of magnetic fiel...When the cold atom clock operates in microgravity around the near-earth orbit, its performance will be affected by the fluctuation of magnetic field. A strategy is proposed to suppress the fluctuation of magnetic field by additional coils, whose current is changed accordingly to compensate the magnetic fluctuation by the linear and incremental compensation. The flight model of the cold atom clock is tested in a simulated orbital magnetic environment and the magnetic field fluctuation in the Ramsey cavity is reduced from 17 nT to 2 nT, which implied the uncertainty due to the second order Zeeman shift is reduced to be less than 2×10^(-16). In addition, utilizing the compensation, the magnetic field in the trapping zone can be suppressed from 7.5 μT to less than 0.3 μT to meet the magnetic field requirement of polarization gradients cooling of atoms.展开更多
The remaining challenges, confronting high-power microwave (HPM) sources and pulsed power generators, stim- ulate the developments of robust relativistic electron beam sources. This paper presents a carbon fibre cat...The remaining challenges, confronting high-power microwave (HPM) sources and pulsed power generators, stim- ulate the developments of robust relativistic electron beam sources. This paper presents a carbon fibre cathode which is tested in a single pulsed power generator. The distribution and the development of cathode plasma are observed by time-and-space resolved diagnostics, and the uniformity of electron beam density is checked by taking x-ray images. A quasistationary behaviour of cathode plasma expansion is observed. It is found that the uniformity of the extracted electron beam is satisfactory in spite of individual plasma jets on the cathode surface. These results show that carbon fibre cathodes can provide a positive prospect for developing a high-quality electron beam.展开更多
基金Project supported by the Ministry of Science and Technology of China(Grant No.2013YQ09094304)the Youth Innovation Promotion Association,Chinese Academy of Sciencesthe National Natural Science Foundation of China(Grant Nos.11034008 and 11274324)
文摘When the cold atom clock operates in microgravity around the near-earth orbit, its performance will be affected by the fluctuation of magnetic field. A strategy is proposed to suppress the fluctuation of magnetic field by additional coils, whose current is changed accordingly to compensate the magnetic fluctuation by the linear and incremental compensation. The flight model of the cold atom clock is tested in a simulated orbital magnetic environment and the magnetic field fluctuation in the Ramsey cavity is reduced from 17 nT to 2 nT, which implied the uncertainty due to the second order Zeeman shift is reduced to be less than 2×10^(-16). In addition, utilizing the compensation, the magnetic field in the trapping zone can be suppressed from 7.5 μT to less than 0.3 μT to meet the magnetic field requirement of polarization gradients cooling of atoms.
基金Project supported by the National High Technology Research and Development Program of China
文摘The remaining challenges, confronting high-power microwave (HPM) sources and pulsed power generators, stim- ulate the developments of robust relativistic electron beam sources. This paper presents a carbon fibre cathode which is tested in a single pulsed power generator. The distribution and the development of cathode plasma are observed by time-and-space resolved diagnostics, and the uniformity of electron beam density is checked by taking x-ray images. A quasistationary behaviour of cathode plasma expansion is observed. It is found that the uniformity of the extracted electron beam is satisfactory in spite of individual plasma jets on the cathode surface. These results show that carbon fibre cathodes can provide a positive prospect for developing a high-quality electron beam.