期刊文献+
共找到3,059篇文章
< 1 2 153 >
每页显示 20 50 100
Dynamics and stabilization of peak current-mode controlled buck converter with constant current load 被引量:3
1
作者 冷敏瑞 周国华 +1 位作者 张凯暾 李振华 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期101-109,共9页
The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on th... The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. 展开更多
关键词 buck converter constant current load discrete iterative map model ramp compensation
原文传递
Low voltage substrate current: a monitor for interface states generation in ultra-thin oxide n-MOSFETs under constant voltage stresses
2
作者 王彦刚 许铭真 谭长华 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第11期3502-3506,共5页
The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is f... The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is found that the low voltage Ib is formed by electrons tunnelling through interface states, and the variations of Ib(△Ib) are proportional to variations of Nit (△Nit). The Nit energy distributions were determined by differentiating Nit(Vg). The results have been compared with that measured by using gate diode technique. 展开更多
关键词 interface states substrate current ultra-thin oxide constant voltage stress
原文传递
Field-induced phase transitions in chiral smectic liquid crystals studied by the constant current method
3
作者 H Dhaouadi R Zgueb +2 位作者 O Riahi F Trabelsi T Othman 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期373-379,共7页
In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied pr... In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied product can be obtained.In this work, we make a slight modification to the measurement principles based on this method. This modification allows the characteristic parameters of ferroelectric liquid crystal to be quantitatively measured. The use of a current square signal highlights a phenomenon of ferroelectric hysteresis with remnant polarization at null field, which points out an effect of memory in this compound. 展开更多
关键词 chiral smectic liquid crystal constant current method ferroelectric polarization dielectric permittivity
原文传递
Numerical Solution of MHD Convection and Mass Transfer Flow of Viscous Incompressible Fluid about an Inclined Plate with Hall Current and Constant Heat Flux
4
作者 Mohammad Wahiduzzaman Runu Biswas +2 位作者 Md. Eaqub Ali Md. Shakhaoath Khan Ifsana Karim 《Journal of Applied Mathematics and Physics》 2015年第12期1688-1709,共22页
The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifest... The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifestation of transverse magnetic field near an inclined vertical permeable flat plate. It is assumed that the induced magnetic field is negligible compared with the imposed magnetic field. The governing boundary layer equations have been transferred into non-similar model by implementing similarity approaches. The physical dimensionless parameter has been set up into the model as Prandtl number, Eckert number, Magnetic parameter, Schmidt number, local Grashof number and local modified Grashof number. The numerical method of Nactsheim-Swigert shooting iteration technique together with Runge-Kutta six order iteration scheme has been used to solve the system of governing non-similar equations. The physical effects of the various parameters on dimensionless primary velocity profile, secondary velocity profile, and temperature and concentration profile are discussed graphically. Moreover, the local skin friction coefficient, the local Nusselt number and Sherwood number are shown in tabular form for various values of the parameters. 展开更多
关键词 MHD HEAT and Mass Transfer HALL current Inclined Plate constant HEAT FLUX
在线阅读 下载PDF
Non-inverting buck-boost DC-DC converter based on constant inductor current control
5
作者 Yao Suyi Jiang Jianguo 《Journal of Southeast University(English Edition)》 EI CAS 2021年第2期171-176,共6页
The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the ... The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the dependence on the external components and device variation and make smooth transition between hysteresis control loop and pulse width modulation(PWM)control loop.The small signal model was deduced for the buck and boost operation mode.The inductor current slope control(ICSC)was proposed to implement the automatic mode transition between buck and boost mode in one switching cycle.The results show that the converter prototype has good dynamic response capability,achieving 94%efficiency and 95%peak efficiency at full 10 A load current. 展开更多
关键词 four switch buck-boost converter inductor current slope control constant inductor current control small signal model
在线阅读 下载PDF
Multi-stage constant current charging strategy considering SOC intervals and voltage thresholds
6
作者 Yu Zhang Si Xu Tiezhou Wu 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期143-153,共11页
Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,w... Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,while shortening the charging time.This in turn affects the safety of the charging process.Furthermore,the higher charging currents are not ideal for shortening the charging time in the later stages of charging.To solve the aforementioned problems,in this study,a multi-stage constant current charging strategy is presented.This strategy can shorten the battery charging time by using the increase in battery temperature during the charging process as a constraint,using a genetic algorithm to calculate the charging current value,and investigating the phased approach to charging.Finally,the charging strategy is experimentally validated at different ambient temperatures and different initial SOCs.The experimental results show that the charging strategy proposed in this paper not only reduces the amount of calculations,but also reduces the temperature rise by up to 46.4%and charging time by up to 4.2%under different operating conditions. 展开更多
关键词 Charging time Battery temperature rise Genetic algorithm Multi-stage constant current charging
在线阅读 下载PDF
Circulating current suppression for ground tied variable frequency to constant frequency converter system in aircraft
7
作者 Wei WEI Ming HUANG +2 位作者 Wenli YAO Weilin LI Xiaobin ZHANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第11期386-397,共12页
This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400... This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400 Hz load in an aircraft with a variable frequency power supply.Due to the requirement of aircraft standards,both grounds of the rectification and inversion stage are tied to the metal frame of the aircraft.With such a tied ground,the DC bus voltage rises greatly,and a large circulating current appears in the casing as the ground,which leads to equipment failure and potential safety hazards.According to the existing methods of circulating current fault suppression,this paper analyzes the causes of the above faults and the harmonic components of circulating current and points out the limitations of the existing methods.Therefore,a Common-Mode(CM)choke-based method is proposed to provide a high impedance in the path of the CM circulating current.By doing so,the circulating current can be suppressed without the additional burden of the hardware and control algorithm,which is quite friendly for quality control of mass-production aircraft.Moreover,a simplified mathematic model of the VFCF converter system is derived to calculate the minimum inductance value reference of the CM choke,which saves the weight of passive devices to the greatest extent.Finally,simulation and experimental results are studied to verify the effectiveness of the proposed method. 展开更多
关键词 Aircraft power supply Circulating current Common mode choke Power supply circuits Variable Speed constant Frequency
原文传递
An improved analysis method of constant-current charge/discharge curves and its application to nickel hydroxide electrode
8
作者 潘滔 王建明 +3 位作者 陈惠 赵彦琳 肖慧明 张鉴清 《中国有色金属学会会刊:英文版》 CSCD 2003年第2期462-466,共5页
The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/disch... The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/discharge rates and intermittent discharge experiment are discussed. Though the d t /d E ? 獷 plot is affected by many factors, it clearly has intrinsic relation with the nature of active material such as conductivity and thermodynamic potential of active material, which changes with the state of charge. The d t /d E—E plot can also be applied to other electrochemical active materials, especially to those having several phases during charge or discharge. 展开更多
关键词 镍氢电池 电极 分析方法 改进 放电曲线
在线阅读 下载PDF
Constant Ripple Current Control for Switching DC-DC Converter
9
作者 Gwo-Tarng Chern Jenn-Jong Shieh 《Journal of Energy and Power Engineering》 2012年第9期1437-1441,共5页
The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microele... The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microelectronic load applications. This paper proposes a DC-DC converter using variable on-time and variable switching frequency control enhanced constant ripple current control and reduced magnetic components. The proposed converter is realized by making the turn-offtime proportional to the on-time of the converter, according to the input and output voltage, thereby reducing the corresponding current ripple on output voltage in the continuous conduction mode. A Buck DC-DC converter using the proposed control strategy is analyzed in detail, along with some experimental results to show the performance and effectiveness of this converter. 展开更多
关键词 constant ripple current DC-DC converter variable switching frequency continuous conduction mode indirect currentsensor magnetic component.
在线阅读 下载PDF
An Adaptive Response Compensation Technique for the Constant-Current Hot-Wire Anemometer
10
作者 Soe Minn Khine Tomoya Houra Masato Tagawa 《Open Journal of Fluid Dynamics》 2013年第2期95-108,共14页
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we... An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its effectiveness experimentally for hot-wires of 5 μm, 10 μm and 20 μm in diameter. Then, another novel technique based on a two-sensor probe technique—originally developed for the response compensation of fine-wire thermocouples (Tagawa and Ohta 1997;Tagawa et al. 1998)—has been proposed for estimating thermal time-constants of hot-wires to realize the in-situ response compensation of the CCA. To demonstrate the usefulness of the CCA, we have applied the response compensation schemes to multipoint velocity measure- ment of a turbulent wake flow formed behind a circular cylinder by using a CCA probe consisting of 16 hot-wires, which were driven simultaneously by a very simple constant-current circuit. As a result, the proposed response compensation techniques for the CCA work quite successfully and are capable of improving the response speed of the CCA to obtain reliable measurements comparable to those by the commercially-available constant-temperature hot-wire anemometer (CTA). 展开更多
关键词 Flow Measurement HOT-WIRE ANEMOMETER Turbulent Flow constant-current HOT-WIRE ANEMOMETER Response COMPENSATION Frequency Response Time-constant Multipoint Measurement Digital Signal Processing
暂未订购
Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load
11
作者 Said Oucheriah Abul Azad 《Circuits and Systems》 2024年第3期29-43,共15页
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ... The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations. 展开更多
关键词 Boost Converter Robust Sliding Mode Control constant Power Load (CPL) current-Sensorless Control Extended State Observer
在线阅读 下载PDF
基于超声和图像的车灯控制模块设计方案
12
作者 李泰民 黄平 +3 位作者 徐青 张小虎 胡开威 李晓龙 《汽车电器》 2026年第1期102-104,共3页
本文提出一种融合超声探测与深度学习的智能车灯控制模块设计方案,通过硬件差异化设计、软件多任务调度和算法创新优化,实现前照灯、尾灯及其他小灯的集成化控制,提升系统在恶劣环境下的适应性和响应速度。
关键词 深度学习 超声 FREERTOS BUCK电路 恒流电路 SEPIC电路
在线阅读 下载PDF
汽车LED照明系统的驱动电路设计与光效提升研究
13
作者 史聪聪 徐赞扬 《汽车电器》 2026年第1期105-107,共3页
本文围绕汽车LED照明系统的工程化实现,聚焦两条核心主线:驱动电路的可落地设计与光效提升的系统路径。在驱动电路设计方面,明确了车规输入级、防反接电路与滤波网络在台架上可复现的边界条件;针对恒流与反馈环节,提出包含采样电阻开尔... 本文围绕汽车LED照明系统的工程化实现,聚焦两条核心主线:驱动电路的可落地设计与光效提升的系统路径。在驱动电路设计方面,明确了车规输入级、防反接电路与滤波网络在台架上可复现的边界条件;针对恒流与反馈环节,提出包含采样电阻开尔文走线、补偿网络迭代调试及基于非易失性存储器(Non-Volatile Memory,NVM)的出厂标定在内的完整流程;在EMC与诊断一体化设计上,制定了印刷电路板(Printed Circuit Board,PCB)叠层分区、单点接地与源头抑制的优化顺序。光效提升部分直接靶向光学路径衰减、热-电协同损耗及光谱色度稳定性三类核心损耗源,细化了材料选型、装配洁净控制、光学衍射元件(Diffractive Optical Element,DOE)微调、热接口压缩率验证、热管固定件耐久性测试及短波截止涂层抽检等关键工程动作。 展开更多
关键词 LED 驱动电路 恒流控制 光效提升 热-电协同
在线阅读 下载PDF
Neural network prediction of the shunt current in resistance spot welding
14
作者 张勇 谢红霞 +3 位作者 滕辉 白华 鄢君辉 汪帅兵 《China Welding》 EI CAS 2013年第3期73-78,共6页
An error back propagation (BP) neural network prediction model was established for the shunt current compensation in series resistance spot welding. The input variables for the neural network consist of the resistiv... An error back propagation (BP) neural network prediction model was established for the shunt current compensation in series resistance spot welding. The input variables for the neural network consist of the resistivity of the material, the thickness of workpiece and the spot spacing, and the shunt rate is outputted. A simplified calculation for the shunt rate was presented based on the feature of the constant-current resistance spot welding and the variation of the resistance in resistance spot welding process, and then the data generated by simplified calculation were used to train and adjust the neural network model. The neural network model proposed was used to predict the shunt rate in the spot welding of 20# mlid steel (in Chinese classification) (in 2. 0 mm thickness) and 10# mild steel (in 1.5 mm and 1.0 mm thickness). The maximum relative prediction errors are, respectively, 2. 83%, 1.77% and 3.67%. Shunt current compensation experiments were peoCormed based on the neural network prediction model proposed to check the diameter difference of nuggets. Experimental results show that maximum nugget diameter deviation is less than 4% for both 10# and 20# mlid steels with spot spacing of 30 mm and 50 mm. 展开更多
关键词 resistance spot welding constant current control shunt current neural network prediction model NUGGET
在线阅读 下载PDF
Pion Decay Constant and Masses of Light Quarks and In-medium Goldstone Bosons
15
作者 ZHOU Li-Juan MA Wei-Xing 《Communications in Theoretical Physics》 SCIE CAS CSCD 2006年第6期1085-1088,共4页
Based on the fully dressed confining quark propagator, the pion decay constant fπ, local quark vacuum condensate, and the masses of light quarks and in-medlum Goldstone bosons are investigated. The pion decay constan... Based on the fully dressed confining quark propagator, the pion decay constant fπ, local quark vacuum condensate, and the masses of light quarks and in-medlum Goldstone bosons are investigated. The pion decay constant fπ is predicted and compared with its value of experimental measurement. A great agreement is obtained. With the predicted fπ and values of Goldstone boson masses measured by experiments in free configuration the current masses of light quarks and the masses of in-medium Goldstone bosons are obtained. 展开更多
关键词 pion decay constant quark propagator current mass of light quark masses of in-medium Goldstone bosons
在线阅读 下载PDF
STUDY OF HIGH-STABILITY CURRENT REGULATORS FOR CURRENT FROM 0.1A TO 8A
16
作者 吕品桢 范雅俊 +3 位作者 洪云翔 吴荣权 徐信业 魏海波 《Journal of Electronics(China)》 1995年第1期90-96,共7页
Improving the temperature stability and widening the constant current range are two important problems to be solved in the application of the current regulators. This paper introduces a modular approach for the design... Improving the temperature stability and widening the constant current range are two important problems to be solved in the application of the current regulators. This paper introduces a modular approach for the design of the current regulator with a very wide current range. The test results show that their output current ranges from 0.1A to 8A, with its current temperature coefficient as low as 10-4/℃ to 10-5/℃ and limiting voltage lower than 0.4V. 展开更多
关键词 current REGULATOR constant-current circuit Module current temperature COEFFICIENT Limiting-voltage
在线阅读 下载PDF
A Novel Over-Current Protection Technique Applied to Peak-Current Type DC-DC Converter
17
作者 Yu Fang Tengfei Wei +2 位作者 Liang He Yong Xie Yan Xing 《Journal of Electromagnetic Analysis and Applications》 2010年第6期352-356,共5页
The change of the over-current protection point of the power switches, caused by slope compensation, is analyzed in detail. It is discovered that the peak current protecting value increases as the duty cycle decreases... The change of the over-current protection point of the power switches, caused by slope compensation, is analyzed in detail. It is discovered that the peak current protecting value increases as the duty cycle decreases. As a result, the safety operation of the switches is damaged greatly. A novel solution to improve over-current protection with constant peak current limitation is proposed by inducing synchronous slope compensation into the current limit function instead of the original constant voltage. The design principle and method of the protection circuit based on a UC3846 PWM controller for the interleaved dual-forward converter is presented. Experimental results are given to verify the analysis. 展开更多
关键词 DC-DC CONVERTER Peak-current Control constant Peak-current LIMITING
暂未订购
全固态参数可调脉冲电流源的研制 被引量:1
18
作者 董守龙 赵立胜 +2 位作者 项思哲 姚陈果 余亮 《电工技术学报》 北大核心 2025年第3期812-820,共9页
针对小负载阻值测量场景,该文提出了一种基于全固态方波脉冲电流源的新测量方法。全固态方波脉冲电流源采用现场可编程逻辑门阵列(FPGA)作为控制系统,使用金属-氧化物半导体场效应晶体管(MOSFET)作为控制开关,该系统采用模块化设计,每... 针对小负载阻值测量场景,该文提出了一种基于全固态方波脉冲电流源的新测量方法。全固态方波脉冲电流源采用现场可编程逻辑门阵列(FPGA)作为控制系统,使用金属-氧化物半导体场效应晶体管(MOSFET)作为控制开关,该系统采用模块化设计,每个模块包括一个二极管、一个开关和一个电感。开关导通时,电感串联充电;开关断开时,电感并联向负载放电。通过仿真验证了该拓扑的正确性和可行性。搭建了实验样机,样机可以在5?负载下产生800 ns灵活可调脉冲电流方波。最后,采用标称为0.05?的小负载进行系统测试,系统测试结果与商用精密电阻测试仪测试结果误差在1.5%以内。 展开更多
关键词 脉冲功率技术 脉冲恒流源 小负载测试 脉冲电流
在线阅读 下载PDF
基于复合拓扑切换的锂电池无线充电系统设计 被引量:1
19
作者 黄文聪 宋婷婷 +2 位作者 饶天彪 常雨芳 严怀成 《电机与控制学报》 北大核心 2025年第8期150-162,共13页
为了适应锂电池的恒流-恒压充电特性,避免过充欠充等问题,提出一种基于LCC-LCL/S拓扑的恒流-恒压自切换谐振式无线电能传输系统。该系统不涉及原、副边通信以及移相、调频等复杂的控制方式,仅通过控制副边的两个开关切换拓扑即可实现系... 为了适应锂电池的恒流-恒压充电特性,避免过充欠充等问题,提出一种基于LCC-LCL/S拓扑的恒流-恒压自切换谐振式无线电能传输系统。该系统不涉及原、副边通信以及移相、调频等复杂的控制方式,仅通过控制副边的两个开关切换拓扑即可实现系统输出特性的切换,且充电完成后系统能自动切换至低功耗状态。首先,提出基于LCC-LCL/S的新型混合拓扑,根据单拓扑的等效互感电路分析其输出特性以及零相角特性;其次,基于理论推导与最大安全电流约束给出一套参数配置方法,为参数设计提供理论支撑;然后,考虑切换点负载阻值大小以及系统空载对输出稳定性的影响,分析实际中可能出现的负载开路与充电完成负载移除的特殊情况,验证系统的稳定性与安全性;最后,搭建仿真和实验平台,实现系统最大输出效率为88.6%的恒定输出及平滑切换,验证所提方法的有效性和正确性。 展开更多
关键词 无线电能传输 恒流-恒压切换 LCC-LCL/S拓扑 零相角 参数优化设计 最优负载切换点
在线阅读 下载PDF
基于特征数据信息熵的锂离子储能电站电芯健康状态评估与预测方法研究 被引量:1
20
作者 夏向阳 岳家辉 +2 位作者 张媛 夏天 王明琦 《太阳能学报》 北大核心 2025年第2期78-89,共12页
针对锂离子储能电站簇内电芯老化程度及其一致性难以准确评估的问题,提出基于特征数据信息熵的储能电站锂离子电池健康状态评估与预测方法。该方法将传统属性数据进行优化预处理以形成特征数据集,提出将信息熵概念移植到储能电站特定运... 针对锂离子储能电站簇内电芯老化程度及其一致性难以准确评估的问题,提出基于特征数据信息熵的储能电站锂离子电池健康状态评估与预测方法。该方法将传统属性数据进行优化预处理以形成特征数据集,提出将信息熵概念移植到储能电站特定运行片段数据来展开分析,依据计算特征数据熵值大小情况来反映特征数据的有序程度,实现对簇内电芯老化程度及其一致性的分析判断,同时利用神经网络对熵值进行预测来对储能电站健康状态进行短期预测。最后通过储能电站实际运行数据与20S1P电池仿真模型验证基于特征数据信息熵值法对储能电站健康状态评估与预测的可行性与有效性,并在100 kW/200 kWh储能系统平台进行实际工程应用。 展开更多
关键词 锂离子电池 电池簇 信息熵 特征数据 恒流放电 健康状态
原文传递
上一页 1 2 153 下一页 到第
使用帮助 返回顶部