We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-...We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.展开更多
We here report a high system detection efficiency(SDE)superconducting single-photon detector(SSPD)at 2μm wavelength.The device integrates a SiO_(2)/Ta_(2)O_(5)distributed Bragg reflector(DBR)and a sandwich-structured...We here report a high system detection efficiency(SDE)superconducting single-photon detector(SSPD)at 2μm wavelength.The device integrates a SiO_(2)/Ta_(2)O_(5)distributed Bragg reflector(DBR)and a sandwich-structured double-layer NbN nanowire to enhance the optical absorption efficiency.A cold development technique is implemented to optimize the superconducting nanowires with sub-40-nm linewidths,thus enhancing the intrinsic detection efficiency(IDE).The fabricated SSPD shows an SDE exceeding 90% at 2μm wavelength.Moreover,the detector allows an operational working temperature of 2.2 K provided by a compact GM cryo-cooler.This detector delivers excellent performance at the 2μm wavelength,and its optimized structural design implies promising potential for extending detection toward longer infrared bands.It thus holds value for advancing high-sensitivity quantum technologies,mid-infrared optical communications,and dark matter detection research.展开更多
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl...Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.展开更多
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi...Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.展开更多
In this paper Singular Decompositon Value (SVD) formula and modified Chi-square solution are provided, and the modified Chi-square is combined with FT-IR instrument to control biochemical reaction process. Using the m...In this paper Singular Decompositon Value (SVD) formula and modified Chi-square solution are provided, and the modified Chi-square is combined with FT-IR instrument to control biochemical reaction process. Using the modified Chi-square technique, the unknown concentration of reactants and products in test samples withdrawn from the process is determined. The technique avoids the need for the spectral data to conform to Beer’s Law and the best spectral range is determined automatically.展开更多
The application of frequency distribution statistics to data provides objective means to assess the nature of the data distribution and viability of numerical models that are used to visualize and interpret data.Two c...The application of frequency distribution statistics to data provides objective means to assess the nature of the data distribution and viability of numerical models that are used to visualize and interpret data.Two commonly used tools are the kernel density estimation and reduced chi-squared statistic used in combination with a weighted mean.Due to the wide applicability of these tools,we present a Java-based computer application called KDX to facilitate the visualization of data and the utilization of these numerical tools.展开更多
Diabetes mellitus is a metabolic disease that is ranked among the top 10 causes of death by the world health organization.During the last few years,an alarming increase is observed worldwide with a 70%rise in the dise...Diabetes mellitus is a metabolic disease that is ranked among the top 10 causes of death by the world health organization.During the last few years,an alarming increase is observed worldwide with a 70%rise in the disease since 2000 and an 80%rise in male deaths.If untreated,it results in complications of many vital organs of the human body which may lead to fatality.Early detection of diabetes is a task of significant importance to start timely treatment.This study introduces a methodology for the classification of diabetic and normal people using an ensemble machine learning model and feature fusion of Chi-square and principal component analysis.An ensemble model,logistic tree classifier(LTC),is proposed which incorporates logistic regression and extra tree classifier through a soft voting mechanism.Experiments are also performed using several well-known machine learning algorithms to analyze their performance including logistic regression,extra tree classifier,AdaBoost,Gaussian naive Bayes,decision tree,random forest,and k nearest neighbor.In addition,several experiments are carried out using principal component analysis(PCA)and Chi-square(Chi-2)fea-tures to analyze the influence of feature selection on the performance of machine learning classifiers.Results indicate that Chi-2 features show high performance than both PCA features and original features.However,the highest accuracy is obtained when the proposed ensemble model LTC is used with the proposed fea-ture fusion framework-work which achieves a 0.85 accuracy score which is the highest of the available approaches for diabetes prediction.In addition,the statis-tical T-test proves the statistical significance of the proposed approach over other approaches.展开更多
This study introduces a new classifier tailored to address the limitations inherent in conventional classifiers such as K-nearest neighbor(KNN),random forest(RF),decision tree(DT),and support vector machine(SVM)for ar...This study introduces a new classifier tailored to address the limitations inherent in conventional classifiers such as K-nearest neighbor(KNN),random forest(RF),decision tree(DT),and support vector machine(SVM)for arrhythmia detection.The proposed classifier leverages the Chi-square distance as a primary metric,providing a specialized and original approach for precise arrhythmia detection.To optimize feature selection and refine the classifier’s performance,particle swarm optimization(PSO)is integrated with the Chi-square distance as a fitness function.This synergistic integration enhances the classifier’s capabilities,resulting in a substantial improvement in accuracy for arrhythmia detection.Experimental results demonstrate the efficacy of the proposed method,achieving a noteworthy accuracy rate of 98% with PSO,higher than 89% achieved without any previous optimization.The classifier outperforms machine learning(ML)and deep learning(DL)techniques,underscoring its reliability and superiority in the realm of arrhythmia classification.The promising results render it an effective method to support both academic and medical communities,offering an advanced and precise solution for arrhythmia detection in electrocardiogram(ECG)data.展开更多
We study the asymptotics tot the statistic of chi-square in type Ⅱ error. By the contraction principle, the large deviations and moderate deviations are obtained, and the rate function of moderate deviations can be c...We study the asymptotics tot the statistic of chi-square in type Ⅱ error. By the contraction principle, the large deviations and moderate deviations are obtained, and the rate function of moderate deviations can be calculated explicitly which is a squared function.展开更多
We describe two new derivations of the chi-square distribution. The first derivation uses the induction method, which requires only a single integral to calculate. The second derivation uses the Laplace transform and ...We describe two new derivations of the chi-square distribution. The first derivation uses the induction method, which requires only a single integral to calculate. The second derivation uses the Laplace transform and requires minimum assumptions. The new derivations are compared with the established derivations, such as by convolution, moment generating function, and Bayesian inference. The chi-square testing has seen many applications to physics and other fields. We describe a unique version of the chi-square test where both the variance and location are tested, which is then applied to environmental data. The chi-square test is used to make a judgment whether a laboratory method is capable of detection of gross alpha and beta radioactivity in drinking water for regulatory monitoring to protect health of population. A case of a failure of the chi-square test and its amelioration are described. The chi-square test is compared to and supplemented by the t-test.展开更多
In large sample studies where distributions may be skewed and not readily transformed to symmetry, it may be of greater interest to compare different distributions in terms of percentiles rather than means. For exampl...In large sample studies where distributions may be skewed and not readily transformed to symmetry, it may be of greater interest to compare different distributions in terms of percentiles rather than means. For example, it may be more informative to compare two or more populations with respect to their within population distributions by testing the hypothesis that their corresponding respective 10th, 50th, and 90th percentiles are equal. As a generalization of the median test, the proposed test statistic is asymptotically distributed as Chi-square with degrees of freedom dependent upon the number of percentiles tested and constraints of the null hypothesis. Results from simulation studies are used to validate the nominal 0.05 significance level under the null hypothesis, and asymptotic power properties that are suitable for testing equality of percentile profiles against selected profile discrepancies for a variety of underlying distributions. A pragmatic example is provided to illustrate the comparison of the percentile profiles for four body mass index distributions.展开更多
A new six-parameter continuous distribution called the Generalized Kumaraswamy Generalized Power Gompertz (GKGPG) distribution is proposed in this study, a graphical illustration of the probability density function an...A new six-parameter continuous distribution called the Generalized Kumaraswamy Generalized Power Gompertz (GKGPG) distribution is proposed in this study, a graphical illustration of the probability density function and cumulative distribution function is presented. The statistical features of the Generalized Kumaraswamy Generalized Power Gompertz distribution are systematically derived and adequately studied. The estimation of the model parameters in the absence of censoring and under-right censoring is performed using the method of maximum likelihood. The test statistic for right-censored data, criteria test for GKGPG distribution, estimated matrix Ŵ, Ĉ, and Ĝ, criteria test Y<sup>2</sup>n</sub>, alongside the quadratic form of the test statistic is derived. Mean simulated values of maximum likelihood estimates and their corresponding square mean errors are presented and confirmed to agree closely with the true parameter values. Simulated levels of significance for Y<sup>2</sup>n</sub> (γ) test for the GKGPG model against their theoretical values were recorded. We conclude that the null hypothesis for which simulated samples are fitted by GKGPG distribution is widely validated for the different levels of significance considered. From the summary of the results of the strength of a specific type of braided cord dataset on the GKGPG model, it is observed that the proposed GKGPG model fits the data set for a significance level ε = 0.05.展开更多
Zero-inflated distributions are common in statistical problems where there is interest in testing homogeneity of two or more independent groups. Often, the underlying distribution that has an inflated number of zero-v...Zero-inflated distributions are common in statistical problems where there is interest in testing homogeneity of two or more independent groups. Often, the underlying distribution that has an inflated number of zero-valued observations is asymmetric, and its functional form may not be known or easily characterized. In this case, comparisons of the groups in terms of their respective percentiles may be appropriate as these estimates are nonparametric and more robust to outliers and other irregularities. The median test is often used to compare distributions with similar but asymmetric shapes but may be uninformative when there are excess zeros or dissimilar shapes. For zero-inflated distributions, it is useful to compare the distributions with respect to their proportion of zeros, coupled with the comparison of percentile profiles for the observed non-zero values. A simple chi-square test for simultaneous testing of these two components is proposed, applicable to both continuous and discrete data. Results of simulation studies are reported to summarize empirical power under several scenarios. We give recommendations for the minimum sample size which is necessary to achieve suitable test performance in specific examples.展开更多
X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorpho...X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors.展开更多
The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process th...The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process that leads to a significant deterioration of non-uniformity when scaling up to larger areas.Since the performance of gaseous detectors is highly dependent on the choice of working gas,optimizing the gas mixture offers a promising solution to improve the uniformity performance.This paper addresses these challenges through a combined approach of simulation based on Garfield++and experimental studies.The simulation investigates the properties of different mixing fractions of gas mixtures and their impact on detector performance,including gain uniformity and time resolution.To verify the simulation results,experimental tests were conducted using a multi-channel PICOSEC MM prototype with different gas mixtures.The experimental results are consistent with the findings of the simulation,indicating that a higher concentration of neon significantly improves the detector’s gain uniformity.Furthermore,the influence of gas mixtures on time resolution was explored as a critical performance indicator.The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance.展开更多
To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the...To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the glass-metal hetero-bonding process.This study focuses on the analysis and experimental re-search of the bonding layer in the integrated structure.By optimizing the structural configuration and select-ing suitable bonding processes,the reliability of the telescope system is enhanced.The research indicates that using J-133 adhesive achieves the best performance,with a bonding layer thickness of 0.30 mm and a metal substrate surface roughness of Ra 0.8.These findings significantly enhance the reliability of the optical sys-tem while minimizing potential risks.展开更多
基金supported by National Key R&D grant from the Ministry of Science and Technology of China(Nos.2021YFA1601600,2023YFA1606200)National Science Foundation of China(Nos.12090062,12105008)the Major State Basic Research Development Program of China.
文摘We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.
基金supported by the Strategic Priority Research Program of Chinese Academy of Sciences(Grant No.XDA0520403)Shanghai Municipal Science and Technology Major Project(Grant No.2019SHZDZX01))+1 种基金Innovation Program for Quantum Science and Technology(Grant No.2023ZD0300100)the National Natural Science Foundation of China(Grant Nos.U24A20320 and 62401554)。
文摘We here report a high system detection efficiency(SDE)superconducting single-photon detector(SSPD)at 2μm wavelength.The device integrates a SiO_(2)/Ta_(2)O_(5)distributed Bragg reflector(DBR)and a sandwich-structured double-layer NbN nanowire to enhance the optical absorption efficiency.A cold development technique is implemented to optimize the superconducting nanowires with sub-40-nm linewidths,thus enhancing the intrinsic detection efficiency(IDE).The fabricated SSPD shows an SDE exceeding 90% at 2μm wavelength.Moreover,the detector allows an operational working temperature of 2.2 K provided by a compact GM cryo-cooler.This detector delivers excellent performance at the 2μm wavelength,and its optimized structural design implies promising potential for extending detection toward longer infrared bands.It thus holds value for advancing high-sensitivity quantum technologies,mid-infrared optical communications,and dark matter detection research.
基金supports from the National Natural Science Foundation of China(22375220,U2001214,22471302)the Guangdong Basic and Applied Basic Research Foundation(2024B1515020101)Open Project Fund from State Key Laboratory of Optoelectronic Materials and Technologies(OEMT-2024-KF-08).
文摘Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.
基金supported by the NSFC under Grant No.62474169the National Key Research and Development Program of China under Grant No.2024YFB3212200the funding from USTC under Grant Nos.WK2100000025,KY2190000003,and KY2190000006。
文摘Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.
文摘In this paper Singular Decompositon Value (SVD) formula and modified Chi-square solution are provided, and the modified Chi-square is combined with FT-IR instrument to control biochemical reaction process. Using the modified Chi-square technique, the unknown concentration of reactants and products in test samples withdrawn from the process is determined. The technique avoids the need for the spectral data to conform to Beer’s Law and the best spectral range is determined automatically.
文摘The application of frequency distribution statistics to data provides objective means to assess the nature of the data distribution and viability of numerical models that are used to visualize and interpret data.Two commonly used tools are the kernel density estimation and reduced chi-squared statistic used in combination with a weighted mean.Due to the wide applicability of these tools,we present a Java-based computer application called KDX to facilitate the visualization of data and the utilization of these numerical tools.
基金supported by the Florida Center for Advanced Analytics and Data Science funded by Ernesto.Net(under the Algorithms for Good Grant).
文摘Diabetes mellitus is a metabolic disease that is ranked among the top 10 causes of death by the world health organization.During the last few years,an alarming increase is observed worldwide with a 70%rise in the disease since 2000 and an 80%rise in male deaths.If untreated,it results in complications of many vital organs of the human body which may lead to fatality.Early detection of diabetes is a task of significant importance to start timely treatment.This study introduces a methodology for the classification of diabetic and normal people using an ensemble machine learning model and feature fusion of Chi-square and principal component analysis.An ensemble model,logistic tree classifier(LTC),is proposed which incorporates logistic regression and extra tree classifier through a soft voting mechanism.Experiments are also performed using several well-known machine learning algorithms to analyze their performance including logistic regression,extra tree classifier,AdaBoost,Gaussian naive Bayes,decision tree,random forest,and k nearest neighbor.In addition,several experiments are carried out using principal component analysis(PCA)and Chi-square(Chi-2)fea-tures to analyze the influence of feature selection on the performance of machine learning classifiers.Results indicate that Chi-2 features show high performance than both PCA features and original features.However,the highest accuracy is obtained when the proposed ensemble model LTC is used with the proposed fea-ture fusion framework-work which achieves a 0.85 accuracy score which is the highest of the available approaches for diabetes prediction.In addition,the statis-tical T-test proves the statistical significance of the proposed approach over other approaches.
文摘This study introduces a new classifier tailored to address the limitations inherent in conventional classifiers such as K-nearest neighbor(KNN),random forest(RF),decision tree(DT),and support vector machine(SVM)for arrhythmia detection.The proposed classifier leverages the Chi-square distance as a primary metric,providing a specialized and original approach for precise arrhythmia detection.To optimize feature selection and refine the classifier’s performance,particle swarm optimization(PSO)is integrated with the Chi-square distance as a fitness function.This synergistic integration enhances the classifier’s capabilities,resulting in a substantial improvement in accuracy for arrhythmia detection.Experimental results demonstrate the efficacy of the proposed method,achieving a noteworthy accuracy rate of 98% with PSO,higher than 89% achieved without any previous optimization.The classifier outperforms machine learning(ML)and deep learning(DL)techniques,underscoring its reliability and superiority in the realm of arrhythmia classification.The promising results render it an effective method to support both academic and medical communities,offering an advanced and precise solution for arrhythmia detection in electrocardiogram(ECG)data.
基金the National Natural Science Foundation of China (10571139)
文摘We study the asymptotics tot the statistic of chi-square in type Ⅱ error. By the contraction principle, the large deviations and moderate deviations are obtained, and the rate function of moderate deviations can be calculated explicitly which is a squared function.
文摘We describe two new derivations of the chi-square distribution. The first derivation uses the induction method, which requires only a single integral to calculate. The second derivation uses the Laplace transform and requires minimum assumptions. The new derivations are compared with the established derivations, such as by convolution, moment generating function, and Bayesian inference. The chi-square testing has seen many applications to physics and other fields. We describe a unique version of the chi-square test where both the variance and location are tested, which is then applied to environmental data. The chi-square test is used to make a judgment whether a laboratory method is capable of detection of gross alpha and beta radioactivity in drinking water for regulatory monitoring to protect health of population. A case of a failure of the chi-square test and its amelioration are described. The chi-square test is compared to and supplemented by the t-test.
文摘In large sample studies where distributions may be skewed and not readily transformed to symmetry, it may be of greater interest to compare different distributions in terms of percentiles rather than means. For example, it may be more informative to compare two or more populations with respect to their within population distributions by testing the hypothesis that their corresponding respective 10th, 50th, and 90th percentiles are equal. As a generalization of the median test, the proposed test statistic is asymptotically distributed as Chi-square with degrees of freedom dependent upon the number of percentiles tested and constraints of the null hypothesis. Results from simulation studies are used to validate the nominal 0.05 significance level under the null hypothesis, and asymptotic power properties that are suitable for testing equality of percentile profiles against selected profile discrepancies for a variety of underlying distributions. A pragmatic example is provided to illustrate the comparison of the percentile profiles for four body mass index distributions.
文摘A new six-parameter continuous distribution called the Generalized Kumaraswamy Generalized Power Gompertz (GKGPG) distribution is proposed in this study, a graphical illustration of the probability density function and cumulative distribution function is presented. The statistical features of the Generalized Kumaraswamy Generalized Power Gompertz distribution are systematically derived and adequately studied. The estimation of the model parameters in the absence of censoring and under-right censoring is performed using the method of maximum likelihood. The test statistic for right-censored data, criteria test for GKGPG distribution, estimated matrix Ŵ, Ĉ, and Ĝ, criteria test Y<sup>2</sup>n</sub>, alongside the quadratic form of the test statistic is derived. Mean simulated values of maximum likelihood estimates and their corresponding square mean errors are presented and confirmed to agree closely with the true parameter values. Simulated levels of significance for Y<sup>2</sup>n</sub> (γ) test for the GKGPG model against their theoretical values were recorded. We conclude that the null hypothesis for which simulated samples are fitted by GKGPG distribution is widely validated for the different levels of significance considered. From the summary of the results of the strength of a specific type of braided cord dataset on the GKGPG model, it is observed that the proposed GKGPG model fits the data set for a significance level ε = 0.05.
文摘Zero-inflated distributions are common in statistical problems where there is interest in testing homogeneity of two or more independent groups. Often, the underlying distribution that has an inflated number of zero-valued observations is asymmetric, and its functional form may not be known or easily characterized. In this case, comparisons of the groups in terms of their respective percentiles may be appropriate as these estimates are nonparametric and more robust to outliers and other irregularities. The median test is often used to compare distributions with similar but asymmetric shapes but may be uninformative when there are excess zeros or dissimilar shapes. For zero-inflated distributions, it is useful to compare the distributions with respect to their proportion of zeros, coupled with the comparison of percentile profiles for the observed non-zero values. A simple chi-square test for simultaneous testing of these two components is proposed, applicable to both continuous and discrete data. Results of simulation studies are reported to summarize empirical power under several scenarios. We give recommendations for the minimum sample size which is necessary to achieve suitable test performance in specific examples.
基金supported by the National Natural Science Foundation of China(No.12235006)the National Key Research and Development Program of China(No.2020YFE0202002.
文摘X-ray detectors show potential applications in medical imaging,materials science,and nuclear energy.To achieve high detection efficiency and spatial resolution,many conventional semiconductor materials,such as amorphous selenium,cadmium telluride zinc,and perovskites,have been utilized in direct conversion X-ray detectors.However,these semiconductor materials are susceptible to temperature-induced performance degradation,crystallization,delamination,uneven lattice growth,radiation damage,and high dark current.This study explores a new approach by coupling an FC40 electronic fluorinated liquid with a specialized high-resolution and high-readout-speed complementary metal-oxide-semiconductor(CMOS)pixel array,specifically the Topmetal II−chip,to fabricate a direct conversion X-ray detector.The fluorinated liquid FC40(molecular formula:C_(21)F_(48)N_(2))is an electronic medium that is minimally affected by temperature and displays no issues with uniform conductivity.It exhibits a low dark current and minimal radiation damage and enables customizable thickness in X-ray absorption.This addresses the limitations inherent in conventional semiconductor-based detectors.In this study,simple X-ray detector imaging tests were conducted,demonstrating the excellent coupling capability between FC40 electronic fluorinated liquid and CMOS chips by the X-ray detector.A spatial resolution of 4.0 lp/mm was measured using a striped line par card,and a relatively clear image of a cockroach was displayed in the digital radiography imaging results.Preliminary test results indicated the feasibility of fabricating an X-ray detector by combining FC40 electronic fluorinated liquid and CMOS chips.Owing to the absence of issues related to chip-material coupling,a high spatial resolution could be achieved by reducing the chip pixel size.This method presents a new avenue for studies on novel liquid-based direct conversion X-ray detectors.
基金supported by the National Natural Science Foundation of China(12125505).
文摘The PICOSEC Micromegas(MM)is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure.It features a two-stage amplification process that leads to a significant deterioration of non-uniformity when scaling up to larger areas.Since the performance of gaseous detectors is highly dependent on the choice of working gas,optimizing the gas mixture offers a promising solution to improve the uniformity performance.This paper addresses these challenges through a combined approach of simulation based on Garfield++and experimental studies.The simulation investigates the properties of different mixing fractions of gas mixtures and their impact on detector performance,including gain uniformity and time resolution.To verify the simulation results,experimental tests were conducted using a multi-channel PICOSEC MM prototype with different gas mixtures.The experimental results are consistent with the findings of the simulation,indicating that a higher concentration of neon significantly improves the detector’s gain uniformity.Furthermore,the influence of gas mixtures on time resolution was explored as a critical performance indicator.The study presented in this paper offers valuable insights for improving uniformity in large-area PICOSEC MM detectors and optimizing overall performance.
文摘To detect space gravitational waves in the extremely low-frequency band,the telescope and optic-al platform require high stability and reliability.However,the cantilevered design presents challenges,espe-cially in the glass-metal hetero-bonding process.This study focuses on the analysis and experimental re-search of the bonding layer in the integrated structure.By optimizing the structural configuration and select-ing suitable bonding processes,the reliability of the telescope system is enhanced.The research indicates that using J-133 adhesive achieves the best performance,with a bonding layer thickness of 0.30 mm and a metal substrate surface roughness of Ra 0.8.These findings significantly enhance the reliability of the optical sys-tem while minimizing potential risks.