Heating,Ventilation,andAir Conditioning(HVAC)systems are critical formaintaining thermal comfort in office environments which also crucial for occupant well-being and productivity.This study investigates the impact of...Heating,Ventilation,andAir Conditioning(HVAC)systems are critical formaintaining thermal comfort in office environments which also crucial for occupant well-being and productivity.This study investigates the impact of integrating ceiling fans with higher air conditioning setpoints on thermal comfort and energy efficiency in office environments.Field measurements and questionnaire surveys were conducted to evaluate thermal comfort and energysaving potential under varying conditions.Results show that increasing the AC setpoint from 25○C to 27○C,combined with ceiling fan operation,reduced power consumption by 10%,achieving significant energy savings.Survey data confirmed that 85%of participants reported consistent thermal sensations across all conditions,with ceiling fans effectively compensating for higher setpoints through enhanced air circulation.CFDsimulations revealed that mediumspeed ceiling fan operation produced the most uniformairflowdistribution,with an average air velocity of 0.45 m/s,and minimized temperature variations,ensuring balanced thermal conditions.Temperature analysis showed a reduction in hotspots and cold zones,maintaining an average temperature deviation of less than±0.5○C.Predicted Mean Vote(PMV)evaluations at a 27○C setpoint indicated improved thermal comfort,with average PMV values around−0.3,corresponding to a“neutral”thermal sensation.These findings demonstrate the effectiveness of integrating ceiling fans with HVAC systems in achieving energy efficiency and occupant comfort,offering a sustainable approach to reducing AC energy consumption in office environments.展开更多
Severe damage to suspended ceilings of metal grids and lay-in panels was observed in public buildings during the 2013 M7.0 Lushan earthquake in China. Over the past several years, suspended ceilings have been widely u...Severe damage to suspended ceilings of metal grids and lay-in panels was observed in public buildings during the 2013 M7.0 Lushan earthquake in China. Over the past several years, suspended ceilings have been widely used practice in public buildings throughout China, including government offices, schools and hospitals. To investigate the damage mechanism of suspended ceilings, a series of three-dimensional shake table tests was conducted to reproduce the observed damage. A full-scale reinforced concrete frame was constructed as the testing frame for the ceiling, which was single-story and infilled with brick masonry walls to represent the local construction of low-rise buildings. In general, the ceiling in the tests exhibited similar damage phenomena as the field observations, such as higher vulnerability of perimeter elements and extensive damage to the cross runners. However, it exhibited lower fragility in terms of peak ground/roof accelerations at the initiation of damage. Further investigations are needed to clarify the reasons for this behavior.展开更多
基金support by the National Science and Technology Council under Grant No.NSTC 112-2221-E-167-017-MY3.
文摘Heating,Ventilation,andAir Conditioning(HVAC)systems are critical formaintaining thermal comfort in office environments which also crucial for occupant well-being and productivity.This study investigates the impact of integrating ceiling fans with higher air conditioning setpoints on thermal comfort and energy efficiency in office environments.Field measurements and questionnaire surveys were conducted to evaluate thermal comfort and energysaving potential under varying conditions.Results show that increasing the AC setpoint from 25○C to 27○C,combined with ceiling fan operation,reduced power consumption by 10%,achieving significant energy savings.Survey data confirmed that 85%of participants reported consistent thermal sensations across all conditions,with ceiling fans effectively compensating for higher setpoints through enhanced air circulation.CFDsimulations revealed that mediumspeed ceiling fan operation produced the most uniformairflowdistribution,with an average air velocity of 0.45 m/s,and minimized temperature variations,ensuring balanced thermal conditions.Temperature analysis showed a reduction in hotspots and cold zones,maintaining an average temperature deviation of less than±0.5○C.Predicted Mean Vote(PMV)evaluations at a 27○C setpoint indicated improved thermal comfort,with average PMV values around−0.3,corresponding to a“neutral”thermal sensation.These findings demonstrate the effectiveness of integrating ceiling fans with HVAC systems in achieving energy efficiency and occupant comfort,offering a sustainable approach to reducing AC energy consumption in office environments.
基金Research fund for earthquake engineering of China Earthquake Administration(201508023)a project of the National Science&Technology Support Program during the Twelfth Five-year Plan Period of China(2015BAK17B03)a general program of National Natural Science Foundation of China(51578515)
文摘Severe damage to suspended ceilings of metal grids and lay-in panels was observed in public buildings during the 2013 M7.0 Lushan earthquake in China. Over the past several years, suspended ceilings have been widely used practice in public buildings throughout China, including government offices, schools and hospitals. To investigate the damage mechanism of suspended ceilings, a series of three-dimensional shake table tests was conducted to reproduce the observed damage. A full-scale reinforced concrete frame was constructed as the testing frame for the ceiling, which was single-story and infilled with brick masonry walls to represent the local construction of low-rise buildings. In general, the ceiling in the tests exhibited similar damage phenomena as the field observations, such as higher vulnerability of perimeter elements and extensive damage to the cross runners. However, it exhibited lower fragility in terms of peak ground/roof accelerations at the initiation of damage. Further investigations are needed to clarify the reasons for this behavior.