Capacitive voltage transformers (CVTs) are essential in high-voltage systems. An accurate error assessment is crucial for precise energy metering. However, tracking real-time quantitative changes in capacitive voltage...Capacitive voltage transformers (CVTs) are essential in high-voltage systems. An accurate error assessment is crucial for precise energy metering. However, tracking real-time quantitative changes in capacitive voltage transformer errors, particularly minor variations in multi-channel setups, remains challenging. This paper proposes a method for online error tracking of multi-channel capacitive voltage transformers using a Co-Prediction Matrix. The approach leverages the strong correlation between in-phase channels, particularly the invariance of the signal proportions among them. By establishing a co-prediction matrix based on these proportional relationships, The influence of voltage changes on the primary measurements is mitigated. Analyzing the relationships between the co-prediction matrices over time allows for inferring true measurement errors. Experimental validation with real-world data confirms the effectiveness of the method, demonstrating its capability to continuously track capacitive voltage transformer measurement errors online with precision over extended durations.展开更多
电容式电压互感器(capacitor voltage transformer,CVT)是高压电网中广泛使用的测量设备,对CVT的内绝缘状态进行实时在线评估将有助于维护电力系统的安全稳定。但现有基于群体关联性的CVT内绝缘状态在线评估方法未考虑一次电压波动影响...电容式电压互感器(capacitor voltage transformer,CVT)是高压电网中广泛使用的测量设备,对CVT的内绝缘状态进行实时在线评估将有助于维护电力系统的安全稳定。但现有基于群体关联性的CVT内绝缘状态在线评估方法未考虑一次电压波动影响,导致评估结果可靠性不够高。针对这个问题,提出了一种计及一次电压波动影响的CVT内绝缘状态在线评估方法,该方法以CVT群体间的内在关联性和主成分分析方法对群体的输出信号进行特征提取,以排除一次电压波动的影响,得到表征CVT内绝缘异常的特征信息,再采用随机森林方法对该特征信息进行分析,实现CVT内绝缘状态的实时在线评估。实验分析表明,该方法可有效消除一次电压波动对CVT内绝缘状态在线评估的影响,实现CVT内绝缘状态的准确评估。展开更多
为提高电容量测试发现电容式电压互感器(capacitor voltage transformer,CVT)电容元件击穿缺陷的准确性,针对电容式电压互感器C11测试精度低和温度影响电容量计算结果的问题,提出诊断方案:一是采用全屏蔽反接线低压屏蔽法提高C11电容量...为提高电容量测试发现电容式电压互感器(capacitor voltage transformer,CVT)电容元件击穿缺陷的准确性,针对电容式电压互感器C11测试精度低和温度影响电容量计算结果的问题,提出诊断方案:一是采用全屏蔽反接线低压屏蔽法提高C11电容量测试精度;二是采用同构同温等比法将电容量换算到出厂温度,再进行初值差计算,减小温度对结果的影响。最后,通过一起电容式电压互感器电容元件击穿故障,验证所提方案可有效发现单片电容元件击穿故障,有效提升测试准确性,避免对CVT状态的误判。展开更多
为保证电网安全、稳定和可靠运行,对系统暂态过电压进行监测研究,从而采取相关措施解决其危害是具有重要意义的。文中基于500 kV电容式电压互感器(capacitor voltage transformer,CVT)对电网暂态过电压在线监测技术进行了系统研究。采...为保证电网安全、稳定和可靠运行,对系统暂态过电压进行监测研究,从而采取相关措施解决其危害是具有重要意义的。文中基于500 kV电容式电压互感器(capacitor voltage transformer,CVT)对电网暂态过电压在线监测技术进行了系统研究。采取改造CVT即内置串联低压电容C3形成可靠的耦合分压装置、雷电和操作冲击试验及分析结果表明,其性能满足电网暂态监测要求。基于该分压装置研制了一套智能型暂态过电压监测系统,在实验室通过了相关性能测试,主要为开关动作的单分、单合、重合闸、分合分以及工频电压耦合操作冲击模拟试验电压波形记录。在上述基础上,结合华东电网"瓶窑500 kV变电站配串调整工程"进行了现场安装和立屏,就窑阳5438线启动调试进行了录波。最后对后期运行监测获取的电网暂态过电压典型波形进行了示例,进一步说明该在线监测技术及系统在现场长期应用的可行性和可靠性。展开更多
为验证基于内置低压电容C3电容式试验互感器(Capacitor Voltage Transformer,CVT)测量电力系统过电压波形的分压方式,即低压电容C3与高压电容C1和中压电容C2进行串联分压作为低压臂输出,基于无锡日新厂500kV CVT进行设备改造,串入了自...为验证基于内置低压电容C3电容式试验互感器(Capacitor Voltage Transformer,CVT)测量电力系统过电压波形的分压方式,即低压电容C3与高压电容C1和中压电容C2进行串联分压作为低压臂输出,基于无锡日新厂500kV CVT进行设备改造,串入了自制大容量无感电容单元(54μF)C3,分别进行了模拟工频过电压试验、操作冲击试验和雷电冲击试验。对采集获取的C3两端输出的数字电压波形信号进行了时、频域分析,以及分压比稳定性验证。试验和数据分析结果表明,串接自制大容量无感电容C3两端输出的电压波形光滑平稳,基本无过冲和振荡,分压比与设计值的相对偏差小于1%,即该分压方式适合用于超高压电网系统单次过电压波形的测量。展开更多
文摘Capacitive voltage transformers (CVTs) are essential in high-voltage systems. An accurate error assessment is crucial for precise energy metering. However, tracking real-time quantitative changes in capacitive voltage transformer errors, particularly minor variations in multi-channel setups, remains challenging. This paper proposes a method for online error tracking of multi-channel capacitive voltage transformers using a Co-Prediction Matrix. The approach leverages the strong correlation between in-phase channels, particularly the invariance of the signal proportions among them. By establishing a co-prediction matrix based on these proportional relationships, The influence of voltage changes on the primary measurements is mitigated. Analyzing the relationships between the co-prediction matrices over time allows for inferring true measurement errors. Experimental validation with real-world data confirms the effectiveness of the method, demonstrating its capability to continuously track capacitive voltage transformer measurement errors online with precision over extended durations.
文摘电容式电压互感器(capacitor voltage transformer,CVT)是高压电网中广泛使用的测量设备,对CVT的内绝缘状态进行实时在线评估将有助于维护电力系统的安全稳定。但现有基于群体关联性的CVT内绝缘状态在线评估方法未考虑一次电压波动影响,导致评估结果可靠性不够高。针对这个问题,提出了一种计及一次电压波动影响的CVT内绝缘状态在线评估方法,该方法以CVT群体间的内在关联性和主成分分析方法对群体的输出信号进行特征提取,以排除一次电压波动的影响,得到表征CVT内绝缘异常的特征信息,再采用随机森林方法对该特征信息进行分析,实现CVT内绝缘状态的实时在线评估。实验分析表明,该方法可有效消除一次电压波动对CVT内绝缘状态在线评估的影响,实现CVT内绝缘状态的准确评估。
文摘为提高电容量测试发现电容式电压互感器(capacitor voltage transformer,CVT)电容元件击穿缺陷的准确性,针对电容式电压互感器C11测试精度低和温度影响电容量计算结果的问题,提出诊断方案:一是采用全屏蔽反接线低压屏蔽法提高C11电容量测试精度;二是采用同构同温等比法将电容量换算到出厂温度,再进行初值差计算,减小温度对结果的影响。最后,通过一起电容式电压互感器电容元件击穿故障,验证所提方案可有效发现单片电容元件击穿故障,有效提升测试准确性,避免对CVT状态的误判。
文摘为保证电网安全、稳定和可靠运行,对系统暂态过电压进行监测研究,从而采取相关措施解决其危害是具有重要意义的。文中基于500 kV电容式电压互感器(capacitor voltage transformer,CVT)对电网暂态过电压在线监测技术进行了系统研究。采取改造CVT即内置串联低压电容C3形成可靠的耦合分压装置、雷电和操作冲击试验及分析结果表明,其性能满足电网暂态监测要求。基于该分压装置研制了一套智能型暂态过电压监测系统,在实验室通过了相关性能测试,主要为开关动作的单分、单合、重合闸、分合分以及工频电压耦合操作冲击模拟试验电压波形记录。在上述基础上,结合华东电网"瓶窑500 kV变电站配串调整工程"进行了现场安装和立屏,就窑阳5438线启动调试进行了录波。最后对后期运行监测获取的电网暂态过电压典型波形进行了示例,进一步说明该在线监测技术及系统在现场长期应用的可行性和可靠性。
文摘为验证基于内置低压电容C3电容式试验互感器(Capacitor Voltage Transformer,CVT)测量电力系统过电压波形的分压方式,即低压电容C3与高压电容C1和中压电容C2进行串联分压作为低压臂输出,基于无锡日新厂500kV CVT进行设备改造,串入了自制大容量无感电容单元(54μF)C3,分别进行了模拟工频过电压试验、操作冲击试验和雷电冲击试验。对采集获取的C3两端输出的数字电压波形信号进行了时、频域分析,以及分压比稳定性验证。试验和数据分析结果表明,串接自制大容量无感电容C3两端输出的电压波形光滑平稳,基本无过冲和振荡,分压比与设计值的相对偏差小于1%,即该分压方式适合用于超高压电网系统单次过电压波形的测量。