期刊文献+
共找到30,312篇文章
< 1 2 250 >
每页显示 20 50 100
Practical Implementation of Embedded Controlled Reduced Switch Z-Source Inverter-Fed Induction Motor Drive 被引量:1
1
作者 K. Srinivasan T. Vijayakumar 《Circuits and Systems》 2016年第9期2189-2195,共8页
A cost-effective component minimized embedded controlled Z-source inverter for induction motor drive is presented. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with t... A cost-effective component minimized embedded controlled Z-source inverter for induction motor drive is presented. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with the advantages of the z impedance network (two inductors in series and two X connected capacitors). This new topology, besides the self-boost property, has low switch count and it can operate as a buck-boost inverter. As a result, the new embedded controlled reduced switch Z-source inverter system provides ride through capability during voltage sags, reduces line harmonics, improves power factor, reliability and extends output voltage range. Analysis, simulation and experiment result will be presented to demonstrate these new features. 展开更多
关键词 Embedded Controller Harmonic Distortion Four-Switch Three-Phase inverter z-source inverter
在线阅读 下载PDF
A New Switching Scheme for Z-source Inverter to Minimize Ripples in the Z-source Elements
2
作者 Sengodan Thangaprakash Ammasai Krishnan 《International Journal of Automation and computing》 EI 2012年第2期200-210,共11页
This paper presents a modification in pulse width modulation (PWM) scheme with unequal shoot-through distribution for the Z-source inverter (ZSI) which can minimize ripples in the current through the Z-source indu... This paper presents a modification in pulse width modulation (PWM) scheme with unequal shoot-through distribution for the Z-source inverter (ZSI) which can minimize ripples in the current through the Z-source inductors as well as the voltage across the Z-source capacitors. For the same system parameters, the proposed control technique provides better voltage boost across the Z-source capacitor, DC-link, and also the AC output voltage than the traditional PWM. The ripples in the Z-network elements are found to be reduced by 75 % in the proposed modulation scheme with optimum harmonic profile in the AC output. Since the Zqnetwork requirement will be based on the ripple profile of the elements, the Z-network requirements can be greatly reduced. The effectiveness of the proposed modulation scheme has been simulated in Matlab/Simulink software and the results are validated by the experiment in the laboratory. 展开更多
关键词 z-source inverter (ZSI) pulse width modulation (PWM) shoot-through RIPPLES total harmonic distortion.
在线阅读 下载PDF
Ride through Strategy for a Three-Level Dual Z-Source Inverter Using TRIAC
3
作者 A. Nazar Ali Dr. R. Jeyabharath 《Circuits and Systems》 2016年第11期3911-3921,共11页
A new ride through strategy is introduced in a three-level dual Z-source inverter, for isolation under semiconductor switching failure condition. Here the output will have no significant decrease in the amplitude and ... A new ride through strategy is introduced in a three-level dual Z-source inverter, for isolation under semiconductor switching failure condition. Here the output will have no significant decrease in the amplitude and quality. Instead of diodes, the triacs are added to the inverter source ends, as it can perform a bidirectional power transfer also it can operate well in both low and high voltage operating conditions. The faulted part can be isolated by simply altering the firing pulses for turning on/off the triacs using the carrier based SPWM technique and resulting in a boosting output with zero common mode voltage. Consequently, it forms a common floating point or null point with a zero common mode voltage. It is experimentally verified by using MATLAB, and digital oscilloscope. 展开更多
关键词 Common Mode Voltage Fault Compensation Three-Level inverter Sinusoidal Pulse Width Modulation z-source inverter
在线阅读 下载PDF
Control of Z-Source Inverter Connected to a Single-Phase AC Utility System
4
作者 T. Chandrashekar M. Veerachary 《Journal of Energy and Power Engineering》 2011年第5期447-454,共8页
This paper presents a single-phase Z-source inverter as a power conditioning system for a single phase utility connected system. Z-source inverter is a single-stage topology that has buck-boost feature, which is possi... This paper presents a single-phase Z-source inverter as a power conditioning system for a single phase utility connected system. Z-source inverter is a single-stage topology that has buck-boost feature, which is possible because of additional shoot through state introduced in zero state of the conventional inverter pulse width modulation and provides desired output AC voltage. Small distributed generation (DG) system with alternate energy sources requires power conditioning units with low cost, high efficiency and tolerance to wide range of input voltage variation and has to perform various functions such as dc-ac conversion, system control and achieve power quality norms. To meet some of these requirements a two-loop control strategy for ac side control with grid current feedback with PI control and inner filter capacitor current feedback with proportional control and on dc side PID control for Z-source capacitor voltage regulation are employed, which gives good transient response also suppress load and source disturbances effectively. Theoretical analysis of proposed scheme is established and then simulation results are presented to validate proposed control strategy. 展开更多
关键词 BUCK-BOOST z-source inverter distributed generation phase locked loop.
在线阅读 下载PDF
Intensification of Power Quality Using PMSG and Cascaded Multi Cell Trans-Z-Source Inverter 被引量:1
5
作者 E. Rajendran Dr. C. Kumar Dr. P. Suresh 《Circuits and Systems》 2016年第11期3778-3793,共17页
This script depicts the power quality intensification of Wind Energy Transfer System (WETS) using Permanent Magnet Synchronous Generator (PMSG) and Cascaded Multi Cell Trans-Z-Source Inverter (CMCTZSI). The PMSG knock... This script depicts the power quality intensification of Wind Energy Transfer System (WETS) using Permanent Magnet Synchronous Generator (PMSG) and Cascaded Multi Cell Trans-Z-Source Inverter (CMCTZSI). The PMSG knocks the induction generator and earlier generators, because of their stimulating performances without taking the frame power. The Trans-Z-Source Inverter with one transformer and one capacitor is connected newly. To increase the boosting ratio gratuity a cascaded impression is proposed with adopting multi-winding transformer which provides an option for this manuscript to use coupled inductor as an alternative of multi-winding transformer and remains the matching voltage gain as cascaded multi cell trans-Z- source inverter. Accordingly the parallel capacitances are also balancing the voltage gain. The parallel correlation of the method is essentially to trim down the voltage stresses and to improve the input current gain of the inverter. By using MALAB Simulation, harmonics can be reduced up to 1.32% and also DC side can be boosted up our required level 200 - 1000 V achievable. The new hardware setup results demonstrate to facilitate the multi cell Trans Z-source inverter. This can be generated high-voltage gain [50 V - 1000 V] and also be credible. Moreover, the level of currents, voltages and Harmonics on the machinery is low. 展开更多
关键词 Neuro Fuzzy System (NFS) Permanent Magnet Synchronous Generator (PMSG) Cascaded Multi Cell Trans-z-source inverter (CMCTZSI) Wind Energy Transfer System (WETS)
在线阅读 下载PDF
A Comparison of Control Methods for Z-Source Inverter 被引量:6
6
作者 Cong-Thanh Pham Anwen Shen +2 位作者 Phan Quoc Dzung Nguyen Bao Anh Nguyen Xuan Phu 《Energy and Power Engineering》 2012年第4期187-195,共9页
In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection sho... In recent years, Z-source inverters (ZSI) have been proposed as an replacement power conversion concept which it has both voltage buck and boost abilities. In addition, ZSI doesn’t require dead-time to protection short circuit at two switches any of the same phase leg in the inverter bridge and to achieve optimal harmonic of current, voltage. This paper presents two different control methods (CM) for ZSI. The aim of this study to compare between two modulation methods, there are modi?ed space vector pulse width modulation method (MSVM) and the simple boost control (SBC) about the unique harmonic performance features, the total average and peak switching device power of the inverter system. In addition, this paper also analyzes about the ability exceed modulation index in linear region of two CM using MATLAB/Simulink. 展开更多
关键词 BUCK-BOOST Current SOURCE inverterS (CSIs) Pulse-Width Modulation (PWM) Voltage SOURCE inverterS (VSIs) z-source inverterS (ZSI)
在线阅读 下载PDF
A Comparative Study of Z-source Inverter and Enhanced Topologies 被引量:1
7
作者 Tao Li Qiming Cheng 《CES Transactions on Electrical Machines and Systems》 2018年第3期284-288,共5页
This paper does some theoretical analysis and simulation studies on the most common topologies of Z-source inverter.As we all know,the traditional Z-source inverter has some problems,such as the voltage of the capacit... This paper does some theoretical analysis and simulation studies on the most common topologies of Z-source inverter.As we all know,the traditional Z-source inverter has some problems,such as the voltage of the capacitor which belongs to this topology is higher and there is a startup shock,which caused researchers proposed a variety of improved Z-source topologies to solve these problems.Some of these topologies can increase boost capacity,and some can reduce the capacitor voltage.However,these topologies can improve only part of the problems of the traditional Z-source inverter,which leads to that the users are hard to choose which topologies.Faced with this situation,eleven Z-source topologies are analyzed in terms of boost capacity,inductance start-up current,capacitance stress and economy in this paper.Finally,two kinds of promising topologies were gotten. 展开更多
关键词 Terms-Boost capacity INDUCTANCE START-UP current CAPACITANCE stress economy simulation z-source inverter
在线阅读 下载PDF
A Review on Industrial Applications of Z-Source Inverter
8
作者 Nimrah Saeed Anas Ibrar Aimen Saeed 《Journal of Power and Energy Engineering》 2017年第9期14-31,共18页
Nowadays, Z-source inverters (ZSI) are one of the most emerging topologies in field of power electronics. This paper deals with brief review of Z-source inverter, comprehensive study of its various topologies and sign... Nowadays, Z-source inverters (ZSI) are one of the most emerging topologies in field of power electronics. This paper deals with brief review of Z-source inverter, comprehensive study of its various topologies and significance of ZSI in modern industry. Different PWM techniques are used to obtain wider modulation range and easier real time implementation. This paper provides a systematic reference for future scientists for further development and advancement of ZSI. 展开更多
关键词 BOOST FACTOR IMPEDANCE Network SHOOT Through State PWM Control Methods z-source inverter
暂未订购
Tapped Inductor Quasi-Z-source Inverters 被引量:17
9
作者 ZHOU Yufei HUANG Wenxin ZHAO Jianwu ZHAO Ping 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0016-I0016,192,共1页
提出一种高升压比的单级升压逆变器,它在传统准z源逆变器拓扑中引入抽头电感无源网络,因此称为“抽头电感准z源逆变器”(tapped inductor quasi-Z-source inverter,TL-qZSI)。该抽头电感无源网络包括一个抽头电感和两个二极管,替... 提出一种高升压比的单级升压逆变器,它在传统准z源逆变器拓扑中引入抽头电感无源网络,因此称为“抽头电感准z源逆变器”(tapped inductor quasi-Z-source inverter,TL-qZSI)。该抽头电感无源网络包括一个抽头电感和两个二极管,替代了原准Z源逆变器中的一个电感。类似于抽头电感Z源逆变器(tapped inductor Z-source inverter,TL-ZSI),所提出的逆变器也能提供高升压能力,但比TL-ZSI略低些。分析电路的工作机理、升压能力和控制策略,讨论设计上的考虑。最后通过基于简单升压控制方法的实验结果验证该拓扑的实际性能。 展开更多
关键词 逆变器 电感器 抽头 升压转换器 输入电流 直流电源电压 母线电压 电压应力
原文传递
Complementary inverter based on ZnO thin-film transistors 被引量:1
10
作者 Dunan Hu Genyuan Yu +2 位作者 Ruqi Yang Honglie Lin Jianguo Lu 《Journal of Semiconductors》 2025年第6期106-110,共5页
Complementary inverter is the basic unit for logic circuits,but the inverters based on full oxide thin-film transistors(TFTs)are still very limited.The next challenge is to realize complementary inverters using homoge... Complementary inverter is the basic unit for logic circuits,but the inverters based on full oxide thin-film transistors(TFTs)are still very limited.The next challenge is to realize complementary inverters using homogeneous oxide semiconduc-tors.Herein,we propose the design of complementary inverter based on full ZnO TFTs.Li-N dual-doped ZnO(ZnO:(Li,N))acts as the p-type channel and Al-doped ZnO(ZnO:Al)serves as the n-type channel for fabrication of TFTs,and then the complemen-tary inverter is produced with p-and n-type ZnO TFTs.The homogeneous ZnO-based complementary inverter has typical volt-age transfer characteristics with the voltage gain of 13.34 at the supply voltage of 40 V.This work may open the door for the development of oxide complementary inverters for logic circuits. 展开更多
关键词 complementary inverter thin-film transistor ZNO n-type channel p-type channel
在线阅读 下载PDF
Moving Towards the Reliability-oriented Design of Hairpin Winding for EV Traction Machines Driven by SiC Inverter 被引量:1
11
作者 Xiaowei Ju Yue Zhang +2 位作者 Zhiwei Xue Yuan Cheng Shumei Cui 《CES Transactions on Electrical Machines and Systems》 2025年第1期26-35,共10页
With the development of high-frequency and highvoltagetraction machines(TM)incorporating hairpin windings(HW)and SiC inverters for electric vehicles(EV),both theinterturn voltage stress and temperature within HW are r... With the development of high-frequency and highvoltagetraction machines(TM)incorporating hairpin windings(HW)and SiC inverters for electric vehicles(EV),both theinterturn voltage stress and temperature within HW are rising,increasing the risk of partial discharge(PD),and presentingsignificant challenges to insulation safety.Therefore,this paperaddresses this issue and proposes potential solutions.Firstly,thepaper examines an 8-pole,48-slot,6-layer HW TM to highlightthe unique characteristics of this winding structure,and explainsthe uneven distribution of interturn voltage stress andtemperature.Subsequently,a high-frequency equivalent circuitmodel of the HW TM prototype is developed.The error ofsimulation and experiment is only 5.7%,which proves theaccuracy of the model.Then,an improved HW scheme isproposed to lower the maximum voltage stress by 29.3%.Furthermore,the temperature distribution of HW TM isanalyzed to facilitate a detailed examination of the impact oftemperature on insulation PD.Finally,the partial dischargeinception voltage(PDIV)of interturn insulation,consideringtemperature effects,is calculated and verified throughexperiment.The paper proposes a reliability-oriented designmethod and process for HW TM.It demonstrates that thereliability-oriented design can achieve PD-free performance inthe design stage of HW. 展开更多
关键词 Hairpin winding INSULATION Electric-thermal stress Partial discharge SiC inverter
在线阅读 下载PDF
Grid-Connected/Islanded Switching Control Strategy for Photovoltaic Storage Hybrid Inverters Based on Modified Chimpanzee Optimization Algorithm
12
作者 Chao Zhou Narisu Wang +1 位作者 Fuyin Ni Wenchao Zhang 《Energy Engineering》 EI 2025年第1期265-284,共20页
Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,th... Uneven power distribution,transient voltage,and frequency deviations are observed in the photovoltaic storage hybrid inverter during the switching between grid-connected and island modes.In response to these issues,this paper proposes a grid-connected/island switching control strategy for photovoltaic storage hybrid inverters based on the modified chimpanzee optimization algorithm.The proposed strategy incorporates coupling compensation and power differentiation elements based on the traditional droop control.Then,it combines the angular frequency and voltage amplitude adjustments provided by the phase-locked loop-free pre-synchronization control strategy.Precise pre-synchronization is achieved by regulating the virtual current to zero and aligning the photovoltaic storage hybrid inverter with the grid voltage.Additionally,two novel operators,learning and emotional behaviors are introduced to enhance the optimization precision of the chimpanzee algorithm.These operators ensure high-precision and high-reliability optimization of the droop control parameters for photovoltaic storage hybrid inverters.A Simulink model was constructed for simulation analysis,which validated the optimized control strategy’s ability to evenly distribute power under load transients.This strategy effectively mitigated transient voltage and current surges during mode transitions.Consequently,seamless and efficient switching between gridconnected and island modes was achieved for the photovoltaic storage hybrid inverter.The enhanced energy utilization efficiency,in turn,offers robust technical support for grid stability. 展开更多
关键词 Photovoltaic storage hybrid inverters modified chimpanzee optimization algorithm droop control seamless switching
在线阅读 下载PDF
SVM strategy and analysis of a three-phase quasi-Z-source inverter with high voltage transmission ratio
13
作者 CHEN DaoLian ZHAO JiaWei QIN ShuRan 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2023年第10期2996-3010,共15页
Herein,we propose a novel three-phase quasi-Z-source inverter with a high voltage transmission ratio to address challenges such as high switching loss and sizeable magnetic components in the basic quasi-Z-source inver... Herein,we propose a novel three-phase quasi-Z-source inverter with a high voltage transmission ratio to address challenges such as high switching loss and sizeable magnetic components in the basic quasi-Z-source inverter.The proposed circuit topology,control strategy,and related analysis are presented.The circuit topology of the inverter comprises a quasi-Z-source network with an integrated magnetic inductor,an active clamp circuit,a three-phase inverter bridge,and an output LC filter,all of which are connected in series.An improved 12-sector space vector modulation scheme is proposed based on the root-mean-square value of the voltage and the instantaneous value of the current.Furthermore,analyses of the inverter voltage transmission ratio,resonant process,and parametric design guidelines for integrated magnetic inductor and zero-voltage switching conditions are presented.Experimental results on a 1-kVA prototype inverter demonstrate that the proposed inverter exhibits a higher transmission ratio and efficiency than existing inverters;thus,the proposed inverter would have broad prospects in low-voltage DC-AC applications. 展开更多
关键词 quasi-z-source inverter three-phase inverter ZERO-VOLTAGE-SWITCHING magnetically integrated inductor space vector modulation
原文传递
Applying Sliding Mode Control to Suppress Double Frequency Voltage Ripples in Single-phase Quasi-Z-source Inverters
14
作者 Jaber Merrikhi Ahangarkolaei Mahdi Izadi Tohid Nouri 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第2期671-681,共11页
The inherent double-line frequency ripple(DFR)of the single-phase quasi-Z-Source inverter(qZSI)strongly affects performance and design of the whole system,which requires hardware improvement methods such as additional... The inherent double-line frequency ripple(DFR)of the single-phase quasi-Z-Source inverter(qZSI)strongly affects performance and design of the whole system,which requires hardware improvement methods such as additional semiconductor components or increasing the volume of capacitors and inductors.As a result,hardware solutions increase the price,and the volume and also reduces reliability of the system.In this paper,as a non-hardware solution,a sliding mode control(SMC)method is presented to control the voltage of the qZSI capacitor.To suppress the DFR,a second-order harmonic is injected into the capacitor reference voltage.Simulation and experimental results show that the introduced controller will have satisfactory results in reducing the DFR without any hardware changes in the qZSI,such as increasing the volume of the capacitor and inductor,adding a semiconductor,or increasing the frequency.A simulation model and experimental prototype are provided to demonstrate the validation of the effectiveness of the proposed controller. 展开更多
关键词 Double-frequency ripple quasi-z-source inverter sliding mode control
原文传递
Fault Diagnosis Method for Open-circuit Faults in NPC Three-level Inverter based on WKCNN
15
作者 Guozheng Zhang Menghui Li +1 位作者 Xin Gu Wei Chen 《CES Transactions on Electrical Machines and Systems》 2025年第2期234-245,共12页
With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered wide... With the increasing demand for high reliability and availability in power conversion equipment within power electronics systems,the fault diagnosis of neutral-point-clamped(NPC) three-level inverters has garnered widespread attention.To address the challenges of fault feature extraction,this article proposes an end-to-end diagnostic approach based on a wavelet kernel convolutional neural network (WKCNN),capable of extracting multi-scale features from current signals to significantly enhance diagnostic accuracy.This method directly uses raw three-phase current signals as input,applying wavelet kernel convolution to automatically capture frequency-domain fault features,combined with a Softmax classifier optimized by the Adam algorithm to achieve fault diagnosis for NPC threelevel inverters.Experimental results under various operating conditions demonstrate that this approach maintains robust diagnostic accuracy across multiple fault scenarios,with comparative analysis further confirming its advantages in diagnostic efficiency and performance over traditional machine learning and other deep learning methods. 展开更多
关键词 NPC three-level inverter Open-circuit fault Wavelet transform Convolutional neural network END-TO-END
在线阅读 下载PDF
Integrated paralleling of NPC inverters with suppressed circulating current for high-power renewable energy conversion
16
作者 Weiwei Li Guoxiang Hua +1 位作者 Xing Huang Xueguang Zhang 《Global Energy Interconnection》 2025年第1期134-142,共9页
The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interl... The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices. 展开更多
关键词 Circulating current Neutral point clamped Parallel operating inverters Space vector modulation
在线阅读 下载PDF
Fault Diagnosis Method for Photovoltaic Grid-Connected Inverters Based on MPA-VMD-PSO BiLSTM
17
作者 Jingxian Ni Chaomeng Wang +2 位作者 Shiqi Sun Yuxuan Sun Gang Ma 《Energy Engineering》 2025年第9期3719-3736,共18页
To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which rel... To improve the fault diagnosis accuracy of a PV grid-connected inverter,a PV grid-connected inverter data diagnosis method based on MPA-VMD-PSO-BiLSTM is proposed.Firstly,unlike the traditional VMD algorithm which relies on manual experience to set parameters(e.g.,noise tolerance,penalty parameter,number of decompositions),this paper achieves adaptive optimization of parameters through MPA algorithmto avoid the problemof feature information loss caused by manual parameter tuning,and adopts the improved VMD algorithm for feature extraction of DC-side voltage data signals of PV-grid-connected inverters;and then,adopts the PSO algorithm for theThen,the PSO algorithm is used to optimize the optimal batch size,the number of nodes in the hidden layer and the learning rate of the BiLSTM network,which significantly improves the model’s ability to capture the long-term dependent features of the PV inverter’s timing signals,to construct the PV grid-connected inverter prediction model of PSO-BiLSTM,and predict the capacitance value of the PVgrid-connected inverter.Finally,diagnostic experiments are carried out based on the expected capacitance value and the capacitance failure criterion.The results showthat compared with the traditional VMD algorithm,the MPA-optimised VMD improves the signal-to-noise ratio(SNR)of the signal decomposition from 28.5 to 33.2 dB(16.5%improvement).After combining with the PSO-BiLSTM model,the mean absolute percentage error(MAPE)of the fault diagnosis is reduced to 1.31%,and the coefficient of determination(R2)is up to 0.99.It is concluded that the present method has excellent diagnostic performance of PV grid-connected inverter data signals and effectively improves the accuracy of PV grid-connected inverter diagnosis. 展开更多
关键词 Photovoltaic grid connection inverterS signal diagnostics MPA algorithm VMD algorithm BiLSTM network
在线阅读 下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
18
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 z-source inverter THREE-PHASE FOUR-LEG inverter Unbalanced Load Imbalanced VOLTAGE
在线阅读 下载PDF
Review of Fault-tolerant Control for Motor Inverter Failure with Operational Quality Considered 被引量:1
19
作者 Yuxuan Du Wenxiang Zhao +2 位作者 Yihua Hu Jinghua Ji Tao Tao 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期202-215,共14页
In recent years,motor drive systems have garnered increasing attention due to their high efficiency and superior control performance.This is especially apparent in aerospace,marine propulsion,and electric vehicles,whe... In recent years,motor drive systems have garnered increasing attention due to their high efficiency and superior control performance.This is especially apparent in aerospace,marine propulsion,and electric vehicles,where high performance,efficiency,and reliability are crucial.The ability of the drive system to maintain long-term fault-tolerant control(FTC)operation after a failure is essential.The likelihood of inverter failures surpasses that of other components in the drive system,highlighting its critical importance.Long-term FTC operation ensures the system retains its fundamental functions until safe repairs or replacements can be made.The focus of developing a FTC strategy has shifted from basic FTC operations to enhancing the post-fault quality to accommodate the realities of prolonged operation post-failure.This paper primarily investigates FTC strategies for inverter failures in various motor drive systems over the past decade.These strategies are categorized into three types based on post-fault operational quality:rescue,remedy,and reestablishment.The paper discusses each typical control strategy and its research focus,the strengths and weaknesses of various algorithms,and recent advancements in FTC.Finally,this review summarizes effective FTC techniques for inverter failures in motor drive systems and suggests directions for future research. 展开更多
关键词 FAULT-TOLERANT Motor drive Operation quality inverter failure
在线阅读 下载PDF
Review of Three-phase Soft Switching Inverters and Challenges for Motor Drives 被引量:1
20
作者 Haifeng Lu Qiao Wang +1 位作者 Jianyun Chai Yongdong Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期177-190,共14页
For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging ... For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging speed and power density.However,this trend poses significant challenges for high-voltage and high-frequency motor controllers,which are plagued by increased switching losses and pronounced switching oscillations as consequences of hard switching.The deployment of soft switching technology presents a viable solution to mitigate these issues.This paper reviews the applications of soft switching technologies for three-phase inverters and classifies them based on distinct characteristics.For each type of inverter,the advantages and disadvantages are evaluated.Then,the paper introduces the research progress and control methods of soft switching inverters (SSIs).Moreover,it presents a comparative analysis among the conventional hard switching inverters (HSIs),an active clamping resonant DC link inverter (ACRDCLI) and an auxiliary resonant commuted pole inverter (ARCPI).Finally,the problems and prospects of soft switching technology applied to motor controllers for EVs are put forward. 展开更多
关键词 Soft switching inverters Zero-voltage switching Electric vehicles Motor drives
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部