摘要 This paper presents a single-phase Z-source inverter as a power conditioning system for a single phase utility connected system. Z-source inverter is a single-stage topology that has buck-boost feature, which is possible because of additional shoot through state introduced in zero state of the conventional inverter pulse width modulation and provides desired output AC voltage. Small distributed generation (DG) system with alternate energy sources requires power conditioning units with low cost, high efficiency and tolerance to wide range of input voltage variation and has to perform various functions such as dc-ac conversion, system control and achieve power quality norms. To meet some of these requirements a two-loop control strategy for ac side control with grid current feedback with PI control and inner filter capacitor current feedback with proportional control and on dc side PID control for Z-source capacitor voltage regulation are employed, which gives good transient response also suppress load and source disturbances effectively. Theoretical analysis of proposed scheme is established and then simulation results are presented to validate proposed control strategy.
出处 《Journal of Energy and Power Engineering》 2011年第5期447-454,共8页 能源与动力工程(美国大卫英文)
关键词 BUCK-BOOST Z-source inverter distributed generation phase locked loop. 公用工程系统 控制策略 逆变器 单相 AC 连接 功率调节系统 交流电压
  • 相关文献

参考文献14

  • 1J.L.D. Monaco, The role of distributed generation in the critical electric power infrastructure, in: Proc. 2001 IEEE Power Engineering Society WinterMeeting, vol. 1, Columbus, OH, USA, Jan.-Feb., 2001, pp. 144-145.
  • 2Y. Xue, L. Chang, S.B. Kjaer, J. Bordonau, T. Shimizu, Topologies of single-phase inverters for small distributed power generators: An overview, IEEE Trans. on Power Electron. 19 (5) (2004) 1305-1314.
  • 3IEEE 1547 Standard for Interconnecting Distributed Resources with Electric Power Systems, 2003.
  • 4M.P. Kazmierkowski, L. Malesani, Current control techniques for three-phase voltage-source PWM converters: A survey, IEEE Transactions on Industrial Electronics 45 (5) (1998) 691-703.
  • 5F.Z. Peng, Z-source inverter, IEEE Trans. Ind. Appl. 39 (2) (2003) 504-510.
  • 6D.G. Holmes, The significance of zero space vector placement for carrier-based PWM schemes, IEEE Trans. Ind. Appl. 32 (5) (1996) 1122-1129.
  • 7P.C. Loh, D.M. Vilathgamuwa, Y.S. Lai, G.T. Chua, Y.W. Li, Pulse-width modulation of Z-source inverters, [EEE Trans. Power Electron. 21 (6) (2005) 1346-1355.
  • 8P.C. Loh, D.M. Vilathgamuwa, C.J. Gajanayake, Y.R. Lira, C.W. Teo, Transient modeling and analysis of pulse-width modulated Z-source inverter, IEEE Trans. on Power Electron. 22 (2) (2007) 498-507.
  • 9M. Veerachary, General rules for signal flowgraph modeling and analysis of dc-dc converters, IEEE Trans. Aerosp. Electron. Syst. 40 (1) (2004) 259-271.
  • 10X.P. Ding, Z.M. Qian, S.T. Yang, B. Cui, F.Z. Peng, A PID control strategy for DC-link voltage in Z-source inverter, in: IEEE Applied Power Electronics Conference, APEC, Feb. 25-Mar. 1, 2007, pp. 1145-1148.