期刊文献+
共找到72篇文章
< 1 2 4 >
每页显示 20 50 100
AN INCREMENTAL METHOD OF X-RAY DIFFRACTION QUANTITATIVE PHASE ANALYSIS OF SAMPLESCONTAINING AMORPHOUS MATERIAL
1
作者 G. Chu(Department of Applied Chemistry Fushun Petroleum Institute, Fushun 113001, China) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1997年第1期35-38,共4页
A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtai... A new method for quantitative X-ray diffraction phase analysis of a powder misture has been developed according to Popovic's doping method. The weight fraction of amorphous material in the analysed sample is obtained. For a multicomponent system in which (n-2) pure phases are added into an n-phase compnent sample and theweight fractions of all n phases can be determined by the method. The test results of confirmation agree well with the theory. 展开更多
关键词 x-ray diffraction quantitative phase analysis amorphous material mass absorption coefficient
在线阅读 下载PDF
A SOLUTION OF MINIMUM NORM FOR QUANTITATIVE PHASE ANALYSIS BY STANDARDLESS X-RAY DIFFRACTION
2
作者 ZHAO Han GONG Yansheng SHEN Jingyuan RUAN Qikuan JIN Jialing ZHU Hanyu Research Institute of Qiqihar Steel Works,Fulaerji,China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1991年第9期225-229,共5页
A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus.The criterion of standardless X-ray diffraction analysis was suggested,so as ... A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus.The criterion of standardless X-ray diffraction analysis was suggested,so as to separate the diffraction pattern of every phase from that of sample.The optimal solution could be obtained by the least squares regression. 展开更多
关键词 x-ray diffraction standardless phase analysis least square regression
在线阅读 下载PDF
A SOLUTION OF MINIMUM NORM FOR QUANTITATIVE PHASE ANALYSIS BY STANDARDLESS X-RAY DIFFRACTION
3
作者 ZHAO Han GONG Yansheng SHEN Jingyuan RUAN Qikuan JIN Jialing ZHU Hanyu Research Institute of Qiqihar Steel Works,Fulaerji,China GONG Yansheng Senior Engineer,Research Institute of Qiqihar Steel Works,Filaerji 161041,China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1990年第9期225-229,共5页
A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus,The criterion of standardless X-ray diffraction analysis was suggested,so as ... A new expression of quantitative phase analysis by standardless X-ray diffraction has been derived using intensity matrix of vector modulus,The criterion of standardless X-ray diffraction analysis was suggested,so as to separate the diffraction pattern of every phase from that of sample.The optimal solution could be obtained by the least squares regression. 展开更多
关键词 x-ray diffraction standardless phase analysis least square regression
在线阅读 下载PDF
AN EXTERNAL STANDARD METHOD OF QUANTITATIVE PHASE ANALYSIS OF THE SAMPLE CONTAINING AN AMORPHOUS PHASE BY X—RAY DIFFRACTION 被引量:5
4
作者 CHU Gang, SUI QinFushun Petroleum Institute. Fushun. China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1994年第3期179-182,共4页
A new method of the quantitative phase analysis of the sample containing an amorphous phase or a standardless phase by X-ray diffraction is proposed in the paper. The addtion of a reference phase or some analytical ph... A new method of the quantitative phase analysis of the sample containing an amorphous phase or a standardless phase by X-ray diffraction is proposed in the paper. The addtion of a reference phase or some analytical phase to the analyzed sample is not required in this method and the experimental results are satisfactory. 展开更多
关键词 quantitative phase analysis x-ray diffraction
在线阅读 下载PDF
MULTI-PEAK MATCH INTENSITY RATIO METHOD OF QUANTI-TATIVE X-RAY DIFFRACTION PHASE ANALYSIS 被引量:5
5
作者 G. Chu, Y.F. Cong and H.J. YouResearch Center of Analysis and Test, Liaoning University of Petroleum & Chemical Technology, Fushun 113001, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2003年第6期489-494,共6页
A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample ... A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory. 展开更多
关键词 x-ray diffraction multi-peak match intensity ratio quantitative phase analysis
在线阅读 下载PDF
Quantitative Phase Analysis of the Calcium Silicate Slag as the Residue of Extracting Alumina from High-Alumina Fly Ash
6
作者 黄冬波 宗燕兵 +2 位作者 刘晓明 彭丹丹 杨志杰 《Journal of Shanghai Jiaotong university(Science)》 EI 2016年第6期729-736,共8页
Calcium silicate slag is the residue of process of pre-desilication alkali lime sintering applied in the high-alumina fly ash to extract the alumina.The quantitative phase analysis(QPA) of the calcium silicate slag ha... Calcium silicate slag is the residue of process of pre-desilication alkali lime sintering applied in the high-alumina fly ash to extract the alumina.The quantitative phase analysis(QPA) of the calcium silicate slag has been performed by the Rietveld method based on the powder X-ray diffraction(XRD) with the aid of noncommercial software GSAS-EXPGUI.A known weight of crystalline internal standard(10% CaF_2) was added to the calcium silicate slag to calculate the fraction of amorphous phase and other crystalline phases on an absolute basis.Besides,the calcium silicate slag was characterized by X-ray fluorescence(XRF) and thermo gravimetric(TG) differential scanning calorimetry(DSC) to test the QPA results and investigate its other characters.Finally,the results show that the amorphous fraction is 17.5%(hereinafter,the percentages refer to the mass fraction),and the major crystalline phases detected in the calcium silicate slag consist of 23.5% Beta-Ca_2 SiO_4,10.0% bredigite,10.3% Ca_3Al_2O_6(C_3A) and 21.6% CaCO_3. 展开更多
关键词 calcium silicate slag x-ray diffraction(XRD) quantitative phase analysis(QPA) Rietveld method
原文传递
Quantification of flupirtine maleate polymorphs using X-ray powder diffraction 被引量:2
7
作者 Yu-Mei Zhao Zhi-Bing Zheng Song Li 《Chinese Chemical Letters》 SCIE CAS CSCD 2016年第11期1666-1672,共7页
Flupirtine maleate, a pharmaceutical compound for treating psychotic disease in clinics, has seven polymorphs. Form A, with better crystal stability and bioavailability, has been widely used as the pharmaceutical crys... Flupirtine maleate, a pharmaceutical compound for treating psychotic disease in clinics, has seven polymorphs. Form A, with better crystal stability and bioavailability, has been widely used as the pharmaceutical crystal form. Unfortunately, it is usually found in a polymorphic mixture with form B. In this study, pure crystal forms of A and B were prepared and characterized by X-ray powder diffraction (XRPD), Fourier transform infrared spectroscopy (FT-IR) and thermal analysis. An XRPD-based method for the quantitative determination of the amount of the flupirtine maleate polymorphs form A and form B was also established through a systematic optimization of instrumental parameters. The results of the analytical methodology validation showed that the XPRD method had a broad quantitative range of 0- 100% (w/w), good linear relationship, with R2= 0.999, excellent repeatability and precision and low limits of detection (LoD) of 0.15% (w/w) and quantification (LoQ) of 0.5% (w/w). The results also showed that the single-peak method was not as good as the whole pattern in reducing the influence of the preferred orientation, but this can be compensated for by a systematic optimization of instrumental parameters and validating the analytical methodology to reduce errors and obtain a good, repeatable, sensitive, and accurate method. This XRPD method can be used to analyze mixtures of flupirtine maleate polymorphs (forms A and B) quantitatively and control the quality of the bulk drug. 展开更多
关键词 Flupirtine maleate x-ray powder diffraction quantitative analysis of polymorphs Preferred orientation Transmission
原文传递
Leaching behavior of phosphorous compounds from sewage sludge ash based on quantitative X-ray diffraction analysis 被引量:2
8
作者 Pinjing He Xiaotong Zhang +2 位作者 Fan Lü Liming Shao Hua Zhang 《Waste Disposal and Sustainable Energy》 2020年第2期113-125,共13页
Phosphorus(P)is an essential and limited resource.Incineration sewage sludge ash(ISSA)contains a high amount of P,which can be recovered using chemical leaching methods.However,the recovery ratio depends on the specia... Phosphorus(P)is an essential and limited resource.Incineration sewage sludge ash(ISSA)contains a high amount of P,which can be recovered using chemical leaching methods.However,the recovery ratio depends on the speciation of P and the leaching conditions.In this study,hydrochloric acid was used as a leaching agent,and the effects of the hydrochloric acid concentration,leaching time,temperature,and liquid-solid ratio on the P leaching ratio were investigated.Furthermore,the co-leaching of macro-metals Ca,Al,Fe,and Mg was analyzed.The results showed that P leached rapidly within 30 min,where the leaching rate reached more than 80%and then gradually stabilized.The leaching concentrations of Ca and Mg had a significant correlation(correlation coefficient r^(2)>0.90),and both were leached completely.Al and P had similar leaching patterns,where the leaching rates increased initially and then decreased with time at 0.2 mol/L HCl.According to X-ray diffraction analysis and Rietveld refinement,the P in ISSA was mainly present in the forms of Mg_(3)Ca_(3)(PO_(4))_(4) and AlPO_(4).When leached using 0.2 mol/L HCl at 55℃ with a liquid-to-solid ratio of 20 L/kg,the AlPO_(4) and Fe_(3)(H_(2)O)_(3)(PO_(4))_(2) in ISSA dissolved initially and then precipitated on the surface of the solid phase,thereby impeding further P leaching. 展开更多
关键词 Sewage sludge ash Acid leaching Phosphorous speciation quantitative x-ray diffraction analysis Rietveld refinement
原文传递
A New Method for Clay Mineral Analysis and Its Application in Geology 被引量:3
9
作者 王河锦 鲁安怀 陈涛 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2002年第4期429-436,共8页
X-ray diffraction (XRD) peaks in a low-angle diffraction section of clayminerals, especially those of authigenic origin, have broadening and tailing features in shape.Using the five basic parameters, peak position, pe... X-ray diffraction (XRD) peaks in a low-angle diffraction section of clayminerals, especially those of authigenic origin, have broadening and tailing features in shape.Using the five basic parameters, peak position, peak height, width, shape coefficient and asymmetry,to describe an XRD peak is more accurate, comprehensive and integrated than using only 3 of them,position, height and width. Following the concept of the five basic parameters of an XRD peak, theprogram Decoform proposed in this study provides more information in mineralogical analyses byfitting actual XRD profiles. In combination with the HW-IR plot, Decoform can he systematically andaccurately used in the comprehensive analyses of crystallinity, domain size, lattice strain andquantitative phase. It is also of value for the geological investigations of diagenesis,metamorphism, basin maturity, structural stress field and so on. 展开更多
关键词 clay minerals x-ray diffraction analysis XRD peak fitting CRYSTALLINITY domain size lattice strain quantitative analysis application in geology
在线阅读 下载PDF
Phase diagram of the CsBr-CaBr_2 system 被引量:1
10
作者 BAO Xinhua CHEN Nianyi +4 位作者 LU Wencong CHENG Zhixuan LUO Yunyun LU Weiying XIA Yiben 《Rare Metals》 SCIE EI CAS CSCD 2006年第3期293-296,共4页
The phase diagram of the CsBr-CaBr2 system was re-determined by using differential thermal analysis and high ternperature and room ternperature X-ray diffraction analysis. It is concluded that there are three intermed... The phase diagram of the CsBr-CaBr2 system was re-determined by using differential thermal analysis and high ternperature and room ternperature X-ray diffraction analysis. It is concluded that there are three intermediate compounds in this system: a.congruently melting compound, CsCaBr3, with a melting point of 823℃ and two incongruently melting compounds, Cs2CaBr4 and Cs3Ca2Br7, whose peritectic points being 597℃ and 635℃, respectively. X-ray diffraction analysis indicated that compound CsCaBr3 is of slightly distorted perovskite structure. 展开更多
关键词 phase diagram CsBr-CaBr2 system differential thermal analysis (DTA) x-ray diffraction analysis perovskite structure
在线阅读 下载PDF
Identification of Rare Earth Phase in the Deformed High Lead-Brasses
11
作者 谈荣生 郭芳 孙连超 《Journal of Rare Earths》 SCIE EI CAS CSCD 1991年第3期228-230,共3页
Deformed high lead-brasses have excellent machining characteristics and good mechanical and physicalproperties.They are widely used in mechanical,clock-watch and pen-making field.Especially,they are suit-able for deep... Deformed high lead-brasses have excellent machining characteristics and good mechanical and physicalproperties.They are widely used in mechanical,clock-watch and pen-making field.Especially,they are suit-able for deep-hole machining.Because of their worse hot-working characteristics,there exists trouble inproduction process.It is reported that the rare earth metals could improve the hot-rolling property,but themechanism is still unclear. 展开更多
关键词 Lead-brasses REM phase analysis Intermetallic compound x-ray diffraction
在线阅读 下载PDF
EQUILIBRIUM PHASE DIAGRAMS IN SYSTEM CuO-PbO-Ag
12
作者 SHAO Zhongbao LIU Kuiren +3 位作者 MENG Bo LI Ying YANG Yuqing(Department of Chemistry,Northeastern University,Shenyang 110006, China) LIU Huakun DOU Shixue(University of New South Wales,Kensington,Australia) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1996年第2期99-102,共4页
Phase equilibrium in the ternary CuO-PbO-Ag system has been investigated using differential thermal analysis(DTA),thermogravimetry(TG),scanning electron microscopy(SEM) and X-ray diffraction(XRD) techniques.In the ter... Phase equilibrium in the ternary CuO-PbO-Ag system has been investigated using differential thermal analysis(DTA),thermogravimetry(TG),scanning electron microscopy(SEM) and X-ray diffraction(XRD) techniques.In the ternary CuO-PbO-Ag system,there is a eutectic reaction CuO+PbO+Ag=L at 750℃ and a composition of 12.04 mol.% Ag,16.35 mol.% CuO and 71.61 mol.% PbO.Two miscibility gaps near the two binary tie lines PbO-Ag and CuO-Ag were detected. No binary or ternary compound was detected in the ternary system.SEM and energy dispersive spectroscopy(EDS) confirm the presence of two liquid phases and the eutectic point. 展开更多
关键词 phase equilibrium CuO-PbO-Ag system phase diagram differential thermal analysis x-ray diffraction
在线阅读 下载PDF
实验条件对X射线衍射物相定量分析结果的影响 被引量:32
13
作者 房俊卓 张霞 徐崇福 《岩矿测试》 CAS CSCD 2008年第1期60-62,共3页
通过实验验证了多物相试样X射线衍射定量分析的基体效应,着重研究了参比强度K值、衍射强度、混合物各物相粒度、X射线管功率等实验条件对物相定量分析结果的影响。结果表明,物相定性分析是定量分析的前提,采用积分强度、使各物相颗粒尽... 通过实验验证了多物相试样X射线衍射定量分析的基体效应,着重研究了参比强度K值、衍射强度、混合物各物相粒度、X射线管功率等实验条件对物相定量分析结果的影响。结果表明,物相定性分析是定量分析的前提,采用积分强度、使各物相颗粒尽可能细而且均匀、采用较高的X射线管功率以及适合的扫描速率均有利于提高物相X射线衍射定量分析的准确度。 展开更多
关键词 X射线衍射 衍射强度 物相定量分析 实验条件
在线阅读 下载PDF
X射线衍射里特沃尔德全谱图拟合法测定粉尘中游离的SiO2 被引量:16
14
作者 曾令民 杨喜英 +2 位作者 王力珩 李小萍 葛宪民 《分析化学》 SCIE EI CAS CSCD 北大核心 2008年第5期599-603,共5页
应用X射线衍射技术与Rietveld全谱图拟合法测定了粉尘中游离SiO2的含量,并同时得到粉尘样品中其它晶相和非晶相物质的含量。实验采用日本理学D/MAX2500V型X射线衍射仪,CuKα辐射带石墨单色器,管电压44kV,管电流150mA,步进扫描收... 应用X射线衍射技术与Rietveld全谱图拟合法测定了粉尘中游离SiO2的含量,并同时得到粉尘样品中其它晶相和非晶相物质的含量。实验采用日本理学D/MAX2500V型X射线衍射仪,CuKα辐射带石墨单色器,管电压44kV,管电流150mA,步进扫描收集衍射数据,经Jade5.0软件定性分析,DBWS9807a软件定量分析,结果为:Rp平均等于11.29%,Rwp平均等于13.74%,Rexpected平均等于4.04%。SiO2在各样品中的含量为15.61%-37.83%;加标回收率为102.6%-119.9%;重现性测定相对标准偏差(RSD)为1.14%。结果表明:用Rietveld全谱图拟合法测定粉尘中游离SiO2的含量是一种快速、准确、方便的方法。 展开更多
关键词 定量分析 游离二氧化硅 非晶体 X射线衍射 Rietveld全谱图拟合法
暂未订购
蒙脱石X射线衍射定量分析方法影响因素研究 被引量:19
15
作者 谌刚 严春杰 +3 位作者 寿瑾枫 韩秀山 陈立松 梅娟 《非金属矿》 CAS CSCD 北大核心 2011年第1期60-62,共3页
蒙脱石作为万能黏土已经在24个领域100多个部门得到广泛应用,其含量的判断标准至关重要。本实验通过分析蒙脱石应用中控制蒙脱石中杂质含量的重要方法——X射线衍射定量分析方法,指出了影响目前蒙脱石X射线衍射定量分析方法的7个主要因素。
关键词 蒙脱石 X射线衍射 定量分析 影响因素
在线阅读 下载PDF
X射线衍射物相定量分析内标法标准曲线库的建立 被引量:18
16
作者 吴建鹏 黄剑锋 +1 位作者 贺海燕 羊俊 《岩矿测试》 CAS CSCD 2006年第3期215-218,共4页
在Rigaku D/Max-2200型X射线衍射仪(XRD)定量分析软件的基础上,制作了无机非金属材料中常用的SiO2(石英)、Al2O3(刚玉)、TiO2等9种组分用XRD采用内标法进行物相定量分析时的标准曲线。结果表明,这些标准曲线的可信度R在0.928... 在Rigaku D/Max-2200型X射线衍射仪(XRD)定量分析软件的基础上,制作了无机非金属材料中常用的SiO2(石英)、Al2O3(刚玉)、TiO2等9种组分用XRD采用内标法进行物相定量分析时的标准曲线。结果表明,这些标准曲线的可信度R在0.928~0.980。通过对已知含量样品的测量,分析结果与实际值一致,说明建立的标准曲线完全可用于高精度物相定量分析。 展开更多
关键词 物相定量分析 内标法 标准曲线 X射线衍射
在线阅读 下载PDF
S Zorb吸附剂Rietveld物相定量方法研究 被引量:26
17
作者 邹亢 黄南贵 徐广通 《石油学报(石油加工)》 EI CAS CSCD 北大核心 2012年第4期598-604,共7页
S Zorb技术是生产低硫清洁汽油的核心技术之一,在装置工业运行过程中发现吸附剂失活快、剂耗高等问题。为了研究吸附剂失活原因,并为国产剂的开发提供支持,利用X射线衍射(XRD)表征S Zorb工业装置中吸附剂的新鲜剂、待生剂和再生剂的晶... S Zorb技术是生产低硫清洁汽油的核心技术之一,在装置工业运行过程中发现吸附剂失活快、剂耗高等问题。为了研究吸附剂失活原因,并为国产剂的开发提供支持,利用X射线衍射(XRD)表征S Zorb工业装置中吸附剂的新鲜剂、待生剂和再生剂的晶体结构,探讨吸附剂物相变化规律,结果表明非活性锌类尖晶石的生成是导致吸附剂失活的主要因素。针对不同剂型的S Zorb吸附剂分别建立了Rietveld相定量方法,表征不同形态吸附剂晶相和非晶相物质的质量分数,并利用XRF方法表征吸附剂化学组成,进一步验证了Rietveld相定量法的准确性,利用29Si NMR表征吸附剂中Si元素的化学环境,验证Rietveld相定量法对无定型SiO2定量结果的准确性。Rietveld相定量法可广泛应用于S Zorb工业装置运行情况监控以及新剂的研究开发。 展开更多
关键词 S ZORB 吸附剂 X射线衍射(XRD) 物相定量分析
在线阅读 下载PDF
X射线衍射多谱峰匹配强度比定量相分析方法 被引量:13
18
作者 储刚 翟秀静 +1 位作者 符岩 毕诗文 《分析测试学报》 CAS CSCD 北大核心 2004年第1期48-51,共4页
提出了1种采用X射线衍射多谱峰匹配强度比进行定量相分析的新方法 ;该法是利用混合物样品X射线衍射谱图中的多谱峰数据 ,结合ICDD卡中的各相标准谱峰的相对强度分布数据进行最小二乘法回归分析 ,求得混合物样品中各相间的多谱峰匹配强度... 提出了1种采用X射线衍射多谱峰匹配强度比进行定量相分析的新方法 ;该法是利用混合物样品X射线衍射谱图中的多谱峰数据 ,结合ICDD卡中的各相标准谱峰的相对强度分布数据进行最小二乘法回归分析 ,求得混合物样品中各相间的多谱峰匹配强度比 ;以多谱峰匹配强度比取代通常采用的特定单一谱线强度比 ,用于混合物样品的X射线衍射定量相分析 ,有利于提高定量相分析的精度 ;采用多谱峰匹配强度比结合绝热法和基体清洗法X射线衍射定量相分析原理 ,通过对4组分混合物样品的分析 ,证实实验结果和理论完全一致。 展开更多
关键词 X射线衍射 多谱峰匹配强度比 定量相分析 混合物样品 晶相
在线阅读 下载PDF
真空铝热还原法制备金属锶的反应机理 被引量:6
19
作者 于金 吴三械 +2 位作者 董岩 谈荣生 朱鸣芳 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2006年第6期951-955,共5页
为提高锶还原率,研究了真空铝热还原法制备金属锶的反应机理.对锶还原率和渣相间关系进行了理论分析;对实际锶还原率进行了计量;并对实际渣相进行了XRD定量分析.理论分析认为,锶还原率越高,则渣相中SrO.A l2O3相数量越多.实验结果表明:... 为提高锶还原率,研究了真空铝热还原法制备金属锶的反应机理.对锶还原率和渣相间关系进行了理论分析;对实际锶还原率进行了计量;并对实际渣相进行了XRD定量分析.理论分析认为,锶还原率越高,则渣相中SrO.A l2O3相数量越多.实验结果表明:制备的金属Sr纯度可达99.5%以上;实际渣相中SrO.A l2O3相质量分数大大高于理论值;且实际锶还原率越低,渣相中SrO.A l2O3相质量分数反而越高.分析认为,原料A l粉被氧化后生成A l2O3,会大量消耗原料SrO,生成SrO.A l2O3相.尽量减少原料A l粉被氧化,是保证高锶还原率的关键. 展开更多
关键词 铝热还原法 XRD 定量分析 锶还原率
在线阅读 下载PDF
粗制氧化锌的X射线衍射全谱图拟合定量相分析探讨 被引量:13
20
作者 吴景武 于泓锦 +1 位作者 冯均利 唐梦奇 《冶金分析》 CAS CSCD 北大核心 2018年第9期14-19,共6页
采用X射线荧光光谱(XRF)半定量法或化学法分析粗制氧化锌中ZnO含量时,如存在Zn、ZnFe_2O_4等非ZnO物相,结果往往偏高,导致一些禁止进口的固体废物进入我国。为此,实验选取两种粗制氧化锌试样,先采用X射线荧光光谱半定量法测定ZnO含量,... 采用X射线荧光光谱(XRF)半定量法或化学法分析粗制氧化锌中ZnO含量时,如存在Zn、ZnFe_2O_4等非ZnO物相,结果往往偏高,导致一些禁止进口的固体废物进入我国。为此,实验选取两种粗制氧化锌试样,先采用X射线荧光光谱半定量法测定ZnO含量,然后采用X射线衍射(XRD)分析技术和Rietveld全谱图拟合定量相分析。利用整个衍射空间的散射信息,用多个不同物理含义的模型对实验数字衍射谱进行Rietveld全谱图拟合。拟合过程采用线性最小平方拟合算法不断调节模型中参数,获得与实际谱线吻合的理论谱线(加权图形剩余方差因子Rwp<10%),最后获得试样组成相的含量。采用在粗制氧化锌中分别加入一定量ZnO,按照上述方法进行Rietveld全谱图拟合分析,结果差值小于5.0%。结果表明:方法精修后得到粗制氧化锌中各常见物相的晶体结构参数与已报道的文献非常接近,实现了ZnO相含量的更准确测定,可用于进口粗制氧化锌的检验监管和属性鉴别。 展开更多
关键词 粗制氧化锌 X射线荧光光谱(XRF) X射线衍射 RIETVELD 定量分析 物相分析
在线阅读 下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部