The SIS system of CTC-1 project of Guoneng Yulin Chemical Co., Ltd. adopts Triconex series control system. This paper describes and explains the construction of the SIS system on the network.
OBJECTIVE:To assess the clinical effectiveness and adverse effects of Yinchenwuling powder(YCWLP)in the treatment of hyperlipidemia using Meta-analysis.METHODS:Seven electronic databases were searched for randomized c...OBJECTIVE:To assess the clinical effectiveness and adverse effects of Yinchenwuling powder(YCWLP)in the treatment of hyperlipidemia using Meta-analysis.METHODS:Seven electronic databases were searched for randomized controlled trials designed to evaluate the clinical effectiveness of YCWLP for hyperlipidemia published in any language prior to February 2015.Two reviewers independently identified articles,extracted data,assessed quality,and cross-checked the results.Revman 5.3 was used to analyze the data.RESULTS:Only five randomized controlled trials with poor methodology were included in the analy-sis.The five trials compared YCWLP with conventional lipid-lowering drugs.Meta-analysis indicated that YCWLP was more effective at the levels of total cholesterol and triglycerides,while increasing the level of high-density lipoprotein cholesterol without serious adverse effects.However,it was not more effective than lipid-lowering drugs in reducing low-density lipoprotein cholesterol and improving hemorheology.CONCLUSION:YCWLP appeared to improve lipid levels.However,given the high risk of bias among the trials,we could not conclude that YCWLP was beneficial to patients with hyperlipidemia.More rigorous trials are required to provide stronger evidence for the conclusion.展开更多
Thermoelectric materials, Mg2Si1-xGex (x=0, 0.2, 0.4, 0.6, 0.8, 1), have been prepared by bulk mechanical alloying (BMA) and hot pressing (HP). The electrical conductivity, Seebeck coefficient and thermal conduc...Thermoelectric materials, Mg2Si1-xGex (x=0, 0.2, 0.4, 0.6, 0.8, 1), have been prepared by bulk mechanical alloying (BMA) and hot pressing (HP). The electrical conductivity, Seebeck coefficient and thermal conductivity were measured from room temperature up to about 700 K. The electrical conductivity of all the samples increases with increasing temperature, while the Seebeck coefficient and thermal conductivity decrease with increasing temperature. Mg2Si and Mg2Si0.8Ge0.2 possess negative type of conductivity, while for other compounds it is positive. At the same time, the effect of hot processing condition on thermoelectric properties was also investigated. The maximum figure of merit of Mg2Si0.6Ge0.4 was obtained with the processing parameter of BMA at 600 cycles and hot pressing at 773 K and i GPa for i h.展开更多
An ion beam analysis system was established on a 1.7 MV tandem accelerator, enabling Rutherford backscattering(RBS), elastic recoil detection(ERD), nuclear reaction analysis(NRA) and channeling measurements. The syste...An ion beam analysis system was established on a 1.7 MV tandem accelerator, enabling Rutherford backscattering(RBS), elastic recoil detection(ERD), nuclear reaction analysis(NRA) and channeling measurements. The system was tested by performing qualitative and quantitative analysis of Si, Ni/Si, Bi Fe O3:La/Si,Mo C/Mo/Si and Ti BN/Si samples. RBS of a Bi Fe O3:La film was used as system calibration. Tested by ion beam channeling, a Si(100) is of good crystallinity(χmin= 3.01%). For thin film samples, the measured thickness agrees well with simulation results by SIMNRA. In particular, composition of a Mo C/Mo/Si and Ti BN film samples were analyzed by RBS and non-Rutherford elastic backscattering.展开更多
Introduction:Robotic systems are designed to address the limitations of laparoscopic surgery,leading to a growing interest in robotic rectal surgery.However,certain technical limitations associated with the previous s...Introduction:Robotic systems are designed to address the limitations of laparoscopic surgery,leading to a growing interest in robotic rectal surgery.However,certain technical limitations associated with the previous systems(da Vinci S&Si)have arguably slowed down its wholesale adoption.The latest robotic platform,the da Vinci Xi,addresses these limitations.This study aims to examine the short-term surgical outcomes of 240 single-docking fully-robotic rectal cancer resections and compare the outcomes of cases performed with the da Vinci Xi vs Si systems.Materials and methods:All consecutive patients receiving robotic rectal cancer resections from three centres between 2013 and 2018 were identified from prospectively collated databases.The baseline characteristics and short-term surgical outcomes are presented and the da Vinci Xi vs Si system outcomes are analysed.Results:A total of 240 patients were identified(124 Si,116 Xi).Median operation-time and length-of-stay were 260 minutes and 6 days respectively.Conversion and 30-day mortality rates were 0.The da Vinci Si vs Xi system analysis shows that operation-time was lower in the Si group(230 vs 300 min,p=0.000)but length-of-stay,lymph node yield and circumferential resection margin favoured the Xi group(7 vs 5 days,p=0.010;17 vs 21,p=0.000;92.7%vs 99.1%,p=0.020).Conclusion:Single-docking fully-robotic rectal cancer surgery is safe,feasible and can lead to good shortterm outcomes,making it a good alternative to laparoscopic rectal cancer surgery.The new systems technological advances may result in better short-term outcomes but further larger scale observational studies are required if we are to reach such a conclusion.展开更多
Dear editor,Pupillary abnormalities, i.e., mydriasis, pupillary arefl exia, and/or anisocoria, may indicate the occurrence of acute clinical events in intensive care units (ICUs),which are particularly seen in severe ...Dear editor,Pupillary abnormalities, i.e., mydriasis, pupillary arefl exia, and/or anisocoria, may indicate the occurrence of acute clinical events in intensive care units (ICUs),which are particularly seen in severe patients with brain and/or cervical spinal cord injury. The pathophysiology of benign episodic mydriasis is still not completely clear. We present a patient with severe burns presented with temporary alternating bilateral pupil enlargement accompanied by paroxysmal increases in respiration,heart rate, and blood pressure.展开更多
To improve the wettability of hypereutectic Al−60Si alloy and enhance the mechanical properties of the joints,Al−60Si alloy was joined by ultrasonic soldering with Sn-9Zn solder,and a sound joint with in-situ Si parti...To improve the wettability of hypereutectic Al−60Si alloy and enhance the mechanical properties of the joints,Al−60Si alloy was joined by ultrasonic soldering with Sn-9Zn solder,and a sound joint with in-situ Si particle reinforcement was obtained.The oxide film of Al−60Si alloy at the interface was identified by transmission electron microscopy(TEM)analysis as amorphous Al_(2)O_(3).The oxide of Si particles in the base metal was also alumina.The oxide film of Al−60Si alloy was observed to be removed by ultrasonic vibration instead of holding treatment.Si particle-reinforced joints(35.7 vol.%)were obtained by increasing the ultrasonication time.The maximum shear strength peaked at 99.5 MPa for soldering at 330℃with an ultrasonic vibration time of 50 s.A model of forming of Si particles reinforced joint under the ultrasound was proposed,and ultrasonic vibration was considered to promote the dissolution of Al and migration of Si particles.展开更多
文摘The SIS system of CTC-1 project of Guoneng Yulin Chemical Co., Ltd. adopts Triconex series control system. This paper describes and explains the construction of the SIS system on the network.
基金Supported by the Chinese National Natural Science Foundation Key Project(Identification of the Molecular Signature Contributing to the Susceptibility of Phlegmatic Hygrosis Constitution to Metabolic Syndrome,No.81030064)
文摘OBJECTIVE:To assess the clinical effectiveness and adverse effects of Yinchenwuling powder(YCWLP)in the treatment of hyperlipidemia using Meta-analysis.METHODS:Seven electronic databases were searched for randomized controlled trials designed to evaluate the clinical effectiveness of YCWLP for hyperlipidemia published in any language prior to February 2015.Two reviewers independently identified articles,extracted data,assessed quality,and cross-checked the results.Revman 5.3 was used to analyze the data.RESULTS:Only five randomized controlled trials with poor methodology were included in the analy-sis.The five trials compared YCWLP with conventional lipid-lowering drugs.Meta-analysis indicated that YCWLP was more effective at the levels of total cholesterol and triglycerides,while increasing the level of high-density lipoprotein cholesterol without serious adverse effects.However,it was not more effective than lipid-lowering drugs in reducing low-density lipoprotein cholesterol and improving hemorheology.CONCLUSION:YCWLP appeared to improve lipid levels.However,given the high risk of bias among the trials,we could not conclude that YCWLP was beneficial to patients with hyperlipidemia.More rigorous trials are required to provide stronger evidence for the conclusion.
文摘Thermoelectric materials, Mg2Si1-xGex (x=0, 0.2, 0.4, 0.6, 0.8, 1), have been prepared by bulk mechanical alloying (BMA) and hot pressing (HP). The electrical conductivity, Seebeck coefficient and thermal conductivity were measured from room temperature up to about 700 K. The electrical conductivity of all the samples increases with increasing temperature, while the Seebeck coefficient and thermal conductivity decrease with increasing temperature. Mg2Si and Mg2Si0.8Ge0.2 possess negative type of conductivity, while for other compounds it is positive. At the same time, the effect of hot processing condition on thermoelectric properties was also investigated. The maximum figure of merit of Mg2Si0.6Ge0.4 was obtained with the processing parameter of BMA at 600 cycles and hot pressing at 773 K and i GPa for i h.
基金Supported by the National Natural Science Foundation of China(No.11405117)the State Key Lab of Advanced Welding and Joining of Harbin Institute of Technology(No.AWJ-M13-03)
文摘An ion beam analysis system was established on a 1.7 MV tandem accelerator, enabling Rutherford backscattering(RBS), elastic recoil detection(ERD), nuclear reaction analysis(NRA) and channeling measurements. The system was tested by performing qualitative and quantitative analysis of Si, Ni/Si, Bi Fe O3:La/Si,Mo C/Mo/Si and Ti BN/Si samples. RBS of a Bi Fe O3:La film was used as system calibration. Tested by ion beam channeling, a Si(100) is of good crystallinity(χmin= 3.01%). For thin film samples, the measured thickness agrees well with simulation results by SIMNRA. In particular, composition of a Mo C/Mo/Si and Ti BN film samples were analyzed by RBS and non-Rutherford elastic backscattering.
文摘Introduction:Robotic systems are designed to address the limitations of laparoscopic surgery,leading to a growing interest in robotic rectal surgery.However,certain technical limitations associated with the previous systems(da Vinci S&Si)have arguably slowed down its wholesale adoption.The latest robotic platform,the da Vinci Xi,addresses these limitations.This study aims to examine the short-term surgical outcomes of 240 single-docking fully-robotic rectal cancer resections and compare the outcomes of cases performed with the da Vinci Xi vs Si systems.Materials and methods:All consecutive patients receiving robotic rectal cancer resections from three centres between 2013 and 2018 were identified from prospectively collated databases.The baseline characteristics and short-term surgical outcomes are presented and the da Vinci Xi vs Si system outcomes are analysed.Results:A total of 240 patients were identified(124 Si,116 Xi).Median operation-time and length-of-stay were 260 minutes and 6 days respectively.Conversion and 30-day mortality rates were 0.The da Vinci Si vs Xi system analysis shows that operation-time was lower in the Si group(230 vs 300 min,p=0.000)but length-of-stay,lymph node yield and circumferential resection margin favoured the Xi group(7 vs 5 days,p=0.010;17 vs 21,p=0.000;92.7%vs 99.1%,p=0.020).Conclusion:Single-docking fully-robotic rectal cancer surgery is safe,feasible and can lead to good shortterm outcomes,making it a good alternative to laparoscopic rectal cancer surgery.The new systems technological advances may result in better short-term outcomes but further larger scale observational studies are required if we are to reach such a conclusion.
文摘Dear editor,Pupillary abnormalities, i.e., mydriasis, pupillary arefl exia, and/or anisocoria, may indicate the occurrence of acute clinical events in intensive care units (ICUs),which are particularly seen in severe patients with brain and/or cervical spinal cord injury. The pathophysiology of benign episodic mydriasis is still not completely clear. We present a patient with severe burns presented with temporary alternating bilateral pupil enlargement accompanied by paroxysmal increases in respiration,heart rate, and blood pressure.
基金financial support from the National Natural Science Foundation of China(Nos.52275385,U2167216)Sichuan Province Science and Technology Support Program,China(No.2022YFG0086).
文摘To improve the wettability of hypereutectic Al−60Si alloy and enhance the mechanical properties of the joints,Al−60Si alloy was joined by ultrasonic soldering with Sn-9Zn solder,and a sound joint with in-situ Si particle reinforcement was obtained.The oxide film of Al−60Si alloy at the interface was identified by transmission electron microscopy(TEM)analysis as amorphous Al_(2)O_(3).The oxide of Si particles in the base metal was also alumina.The oxide film of Al−60Si alloy was observed to be removed by ultrasonic vibration instead of holding treatment.Si particle-reinforced joints(35.7 vol.%)were obtained by increasing the ultrasonication time.The maximum shear strength peaked at 99.5 MPa for soldering at 330℃with an ultrasonic vibration time of 50 s.A model of forming of Si particles reinforced joint under the ultrasound was proposed,and ultrasonic vibration was considered to promote the dissolution of Al and migration of Si particles.