The high-energy cosmic radiation detector(HERD)is a planned experimental instrument at the Chinese Space Station.The silicon charge detector(SCD),a subdetector in HERD,is used to detect cosmic-ray nuclei with a high c...The high-energy cosmic radiation detector(HERD)is a planned experimental instrument at the Chinese Space Station.The silicon charge detector(SCD),a subdetector in HERD,is used to detect cosmic-ray nuclei with a high charge resolution.In this study,we present a compact readout electronic system for the SCD that is designed for the HERD heavy-ion beam test.It comprises front-end readout electronics with 200 input channels as well as data acquisition and data management electronics.The test results showed that the SCD readout system had low noise with a silicon-strip detector connected.The dynamic range could be extended from 200 to 1200 fC,and the cosmic-ray test was performed as expected.展开更多
In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-ene...In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.展开更多
A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board ...A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board with a field-programmable gate array to implement the control logic, and a graphical user interface software based on LabWindows/CVI. The system has been successfully applied in a series of ground-based environmental experiments and almost all the performance tests throughout the entire manufacturing processes. These contribute significantly to the development of the BGO calorimeter before being submitted for satellite-level integration.展开更多
A new wide-range fast readout system capable of adaptive identification is designed for wire scanners,which are used to measure beam profiles and emittance.This system is capable of handling varying current signals wi...A new wide-range fast readout system capable of adaptive identification is designed for wire scanners,which are used to measure beam profiles and emittance.This system is capable of handling varying current signals with Gaussian distributions and current pulses up to 1000 counts/s, as well as an input current range of 1 n A–1 m A. When tested, the resolution was found to exceed 3.68% for full scale, the nonlinearity was found to be less than 0.11%, and the measurement sensibility was found to be less than 5 p A. We believe that the system will play a crucial role in improving the measurement accuracy of beam diagnosis and the efficiency of accelerator operation,as well as decreasing the time required for beam tuning.This system was applied to the beam diagnosis of an injector II prototype for an accelerator-driven subcritical system and produced excellent measurement results. A description of the adaptive fast readout system for wire scanners is presented in this paper.展开更多
The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are dist...The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are distributed on HFRS for particle identification and beam monitoring.The twin TPCs'readout electronics system operates in a trigger-less mode due to its high counting rate,leading to a challenge of handling large amounts of data.To address this problem,we introduced an event-building algorithm.This algorithm employs a hierarchical processing strategy to compress data during transmission and aggregation.In addition,it reconstructs twin TPCs'events online and stores only the reconstructed particle information,which significantly reduces the burden on data transmission and storage resources.Simulation studies demonstrated that the algorithm accurately matches twin TPCs'events and reduces more than 98%of the data volume at a counting rate of 500 kHz/channel.展开更多
A scalable readout system (SRS) is designed to provide a general solution for different micro-pattern gas detectors in various applications. The system mainly consists of three kinds of modules: the ASIC card, the ...A scalable readout system (SRS) is designed to provide a general solution for different micro-pattern gas detectors in various applications. The system mainly consists of three kinds of modules: the ASIC card, the adapter card and the front-end card (FEC). The ASIC cards, mounted with particular ASIC chips, are designed for receiving detector signals. The adapter card is in charge of digitizing the output signals from several ASIC cards. The FEC, edged-mounted with the adapter, has field-programmable gate array (FPGA)-based reconfigurable logic and I/O interfaces, allowing users to choose different ASIC cards and adapters for different experiments, which expands the system to various applications. The FEC transfers data through Gigabit Ethernet protocol realized by a TCP processor (SiTCP) IP core in FPGA. By assembling a flexible number of FECs in parallel through Gigabit Ethernet, the readout system can be tailored to specific sizes to adapt to the experiment scales and readout requirements. In this paper, two kinds of multi-channel ASIC chip, VA140 and AGET, are applied to verify the scalability of this SRS architecture. Based on this VA140 or AGET SRS, one FEC covers 8 ASIC (VA140) cards handling 512 detector channels, or 4 ASIC (AGET) cards handling 256 detector channels, respectively. More FECs can be assembled in crates to handle thousands of detector channels.展开更多
A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is ...A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is greatly alleviated. Using CCD47-10 as its target CCD, the readout system has achieved 8.6e^- readout noise and 142 eV FWHM at 5.9 keV Mn Kα under a pixel rate of 80 kHz. Also its performance of imaging has been investigated.展开更多
This paper describes a low-noise front-end readout circuit for CZT detectors based on TSMC 0.35 um mixed-single CMOS technology;mainly analyzes the noise model of the detector-preamplifier and presents the low-noise c...This paper describes a low-noise front-end readout circuit for CZT detectors based on TSMC 0.35 um mixed-single CMOS technology;mainly analyzes the noise model of the detector-preamplifier and presents the low-noise circuit schematic of charge sensitive preamplifier and shaper. Considering the parasitical influences, the circuit and layout-design are optimized to reduce noise. The preliminary simulation results show that, the equivalent noise charge (ENC) is 74 e﹣ (rms), noise slope is 9 e﹣/pF, power consumption is 2 mW, and non-linearity展开更多
The architecture of a multi-channel front-end system is important for realizing a high-resolution PET system. We propose a novel front-end readout electronic system with TDC to deal with time information for PET syste...The architecture of a multi-channel front-end system is important for realizing a high-resolution PET system. We propose a novel front-end readout electronic system with TDC to deal with time information for PET system which can easily design the timing control. Each channel consists of a charge preamplifier, slow/fast shaper, discriminator and an analog memory. There are an ADC and a TDC to process the energy information and time information for each channel at the same time. In this paper, the whole system signals flow is all simulated by MATLAB. The simulation results show that the proposed system can process slender current from the detector and achieve the energy and time information. The proposed architecture can be applied to high-resolution PET imaging systems with multi-channel ASICs.展开更多
The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(...The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(ETF)is located in the main ring of the HIRFL-CSR.The gamma detector of the ETF is built to measure emitted gamma rays with energies below 5 MeV in the center-of-mass frame and is planned to measure light fragments with energies up to 300 MeV.The readout electronics for the gamma detector were designed and commissioned.The readout electronics consist of thirty-two front-end cards,thirty-two readout control units(RCUs),one common readout unit,one synchronization&clock unit,and one sub-trigger unit.By using the real-time peak-detection algorithm implemented in the RCU,the data volume can be significantly reduced.In addition,trigger logic selection algorithms are implemented to improve the selection of useful events and reduce the data size.The test results show that the integral nonlinearity of the readout electronics is less than 1%,and the energy resolution for measuring the 60 Co source is better than 5.5%.This study discusses the design and performance of the readout electronics.展开更多
The Cooling Storage Ring(CSR)external-target experiment(CEE)will be the first large-scale nuclear physics experiment at the Heavy Ion Research Facility in Lanzhou(HIRFL).A beam monitor has been developed to monitor th...The Cooling Storage Ring(CSR)external-target experiment(CEE)will be the first large-scale nuclear physics experiment at the Heavy Ion Research Facility in Lanzhou(HIRFL).A beam monitor has been developed to monitor the beam status and to improve the reconstruction resolution of the primary vertex.Custom-designed pixel charge sensors,named TopmetalCEEv1,are employed in the detector to locate the position of each particle.Readout electronics for the beam monitor were designed,including front-end electronics utilizing the Topmetal-CEEv1 sensors,as well as a readout and control unit that communicates with the DAQ,trigger,and clock systems.A series of tests were performed to validate the functionality and performance of the system,including basic electronic verifications and responses toαparticles and heavy-ion beams.The results show that all designed functions of the readout electronics system work well,and this system could be used for beam monitoring in the CEE experiment.展开更多
The development of low-cost,non-enzymatic glucose biosensors is crucial for advancing accessible diabetes management.This paper presents the experimental testing of an extended-gate field-effect transistor(EG-FET)that...The development of low-cost,non-enzymatic glucose biosensors is crucial for advancing accessible diabetes management.This paper presents the experimental testing of an extended-gate field-effect transistor(EG-FET)that uses a gold film as the sensing structure.The system innovatively employs a custom-designed inverting operational amplifier circuit for precise signal acquisition and an Arduino Nano platform for real-time data processing and visualization,eliminating the need for expensive laboratory equipment.At the core of the design is a depletion-mode MOSFET,whose current-voltage properties were characterized.The function of the sensor was demonstrated by testing its response to phosphate-buffered saline containing glucose at different concentrations.A clear modulation of the drain current in the linear region of the EG-FET was observed,and a preliminary analysis revealed a linear correlation between the output current and glucose concentration,indicating the system’s potential for quantitative detection.This study successfully validates the feasibility of a compact,cost-effective,and non-enzymatic EG-FET biosensing platform,establishing a solid foundation for future development of point-of-care diagnostic devices.展开更多
Novel schemes for a charge sensitive amplifier (CSA) and a CR-(RC), semi-Gaussian shaper in a fully integrated CMOS readout circuit for particle detectors are presented. The CSA is designed with poly-resistors as ...Novel schemes for a charge sensitive amplifier (CSA) and a CR-(RC), semi-Gaussian shaper in a fully integrated CMOS readout circuit for particle detectors are presented. The CSA is designed with poly-resistors as feedback components to reduce noise. Compared with conventional CSA, the input referred equivalent noise charge(ENC) is simulated to be reduced from 5036e to 2381e with a large detector capacitance of 150pF at the cost of 0.5V output swing loss. The CR-(RC),semi-Gaussian shaper uses MOS transistors in the triode region in series with poly-resistors to compensate process variation without much linearity reduction.展开更多
Based on an avalanche photodiode( APD) detecting array working in Geiger mode( GM-APD), a high-performance infrared sensor readout integrated circuit( ROIC) used for infrared 3D( three-dimensional) imaging is ...Based on an avalanche photodiode( APD) detecting array working in Geiger mode( GM-APD), a high-performance infrared sensor readout integrated circuit( ROIC) used for infrared 3D( three-dimensional) imaging is proposed. The system mainly consists of three functional modules, including active quenching circuit( AQC), time-to-digital converter( TDC) circuit and other timing controller circuit. Each AQC and TDC circuit together constitutes the pixel circuit. Under the cooperation with other modules, the current signal generated by the GM-APD sensor is detected by the AQC, and the photon time-of-flight( TOF) is measured and converted to a digital signal output to achieve a better noise suppression and a higher detection sensitivity by the TDC. The ROIC circuit is fabricated by the CSMC 0. 5 μm standard CMOS technology. The array size is 8 × 8, and the center distance of two adjacent cells is 100μm. The measurement results of the chip showthat the performance of the circuit is good, and the chip can achieve 1 ns time resolution with a 250 MHz reference clock, and the circuit can be used in the array structure of the infrared detection system or focal plane array( FPA).展开更多
This article describes the prototype of the read-out subsystem which will be subject to the BESIII data acquisition system. According to the purpose of the BESIII, the event rate will be about 4000 Hz and the data rat...This article describes the prototype of the read-out subsystem which will be subject to the BESIII data acquisition system. According to the purpose of the BESIII, the event rate will be about 4000 Hz and the data rate up to 50 Mbytes/sec after Level 1 trigger. The read-out subsystem consists of some read-out crates and a read-out computer whose function is to initialize the hardware, to collect the event data from the front-end electronics after Level 1 trigger, to transfer data fragments to the computer in online form through two levels of computer pre-processing and high-speed network transmission. In this model, the crate level read-out implementation is based on the commercial single board computer MVME5100 running the VxWorks operating system. The article outlines the structure of the crate level testing platform of hardware and software. It puts emphasis on the framework of the read-out test model, data process flow and test method at crate level. Especially, it enumerates the key technologies in the process of design and analyses the test results. In addition, results which summarize the performance of the single board computer from the data transferring aspects will be presented.展开更多
“A Craftsman Must Sharpen His Tools to Do His Job,”said Confucius.Nuclear detection and readout techniques are the foundation of particle physics,nuclear physics,and particle astrophysics to reveal the nature of the...“A Craftsman Must Sharpen His Tools to Do His Job,”said Confucius.Nuclear detection and readout techniques are the foundation of particle physics,nuclear physics,and particle astrophysics to reveal the nature of the universe.Also,they are being increasingly used in other disciplines like nuclear power generation,life sciences,environmental sciences,medical sciences,etc.The article reviews the short history,recent development,and trend of nuclear detection and readout techniques,covering Semiconductor Detector,Gaseous Detector,Scintillation Detector,Cherenkov Detector,Transition Radiation Detector,and Readout Techniques.By explaining the principle and using examples,we hope to help the interested reader underst and this research field and bring exciting information to the community.展开更多
A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in uns...A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in unstable nuclei.The CAT-TPC consists of an electronic field cage,double-thick gas-electron-multiplier foils,a general-purpose digital data acquisition system,and a newly developed two-dimensional strip-readout structure.The CAT-TPC was operated using a^(4)He(96%)+CO_(2)(4%)gas mixture at 400 mbar.The working gas also serves as an active target for tracking charged particles.The overall performance of the CAT-TPC was evaluated using a collimated a-particle source.A time resolution of less than 20 ns and a position resolution of less than 0.2 mm were observed along the electron drift direction.Threedimensional images of incident trajectories and scattering events can be clearly reconstructed under an angular resolution of approximately 0.45 degree.展开更多
A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for fut...A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper.展开更多
Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By...Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By utilizing a constant fraction discriminator(CFD) and time-to-digital converter(TDC), challenging dynamic range measurements were performed with high time resolution and event rates. CFD was employed to discriminate the TOF signals from the micro-channel plate and channel electron multipliers. TDC based on the combination of counter and OR-gate delay chain was designed in a highreliability flash field programmable gate array. Owing to the non-uniformity of the delay chain, a correction algorithm based on integral nonlinearity compensation was implemented to reduce the time uncertainty. The test results showed that the electronics achieved a low timingerror of < 200 ps in the input range from 35 to 500 m V for the CFD, and a time resolution of ~550 ps with time uncertainty < 180 ps after correction and a time range of6.4 ls for the TDC. The TOF spectrum from an electron beam experiment of the impacting N_2 gas further indicated the good performance of this readout electronic.展开更多
The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly co...The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications.展开更多
基金supported by the CNSA program(D050102)National Natural Science Foundation of China(Nos.12061131007,12003038,42365006)Young Scientists Fund of the National Natural Science Foundation of China(No.11903037).
文摘The high-energy cosmic radiation detector(HERD)is a planned experimental instrument at the Chinese Space Station.The silicon charge detector(SCD),a subdetector in HERD,is used to detect cosmic-ray nuclei with a high charge resolution.In this study,we present a compact readout electronic system for the SCD that is designed for the HERD heavy-ion beam test.It comprises front-end readout electronics with 200 input channels as well as data acquisition and data management electronics.The test results showed that the SCD readout system had low noise with a silicon-strip detector connected.The dynamic range could be extended from 200 to 1200 fC,and the cosmic-ray test was performed as expected.
基金Foundation of China (Nos. 12227805, U1831206, 12103095, 12235012, 12273120, and 11973097)the Scientific Instrument Developing Project of the Chinese Academy of Sciences (No. GJJSTD20210009)。
文摘In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.
基金supported by the Strategic Priority Research Program on Space Science of Chinese Academy of Sciences(No.XDA04040202-4)the National Basic Research Program(973 Program)of China(No.2010CB833002)
文摘A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board with a field-programmable gate array to implement the control logic, and a graphical user interface software based on LabWindows/CVI. The system has been successfully applied in a series of ground-based environmental experiments and almost all the performance tests throughout the entire manufacturing processes. These contribute significantly to the development of the BGO calorimeter before being submitted for satellite-level integration.
基金supported by the National Natural Science Foundation of China(Nos.11475233,11705257,and 11775285)
文摘A new wide-range fast readout system capable of adaptive identification is designed for wire scanners,which are used to measure beam profiles and emittance.This system is capable of handling varying current signals with Gaussian distributions and current pulses up to 1000 counts/s, as well as an input current range of 1 n A–1 m A. When tested, the resolution was found to exceed 3.68% for full scale, the nonlinearity was found to be less than 0.11%, and the measurement sensibility was found to be less than 5 p A. We believe that the system will play a crucial role in improving the measurement accuracy of beam diagnosis and the efficiency of accelerator operation,as well as decreasing the time required for beam tuning.This system was applied to the beam diagnosis of an injector II prototype for an accelerator-driven subcritical system and produced excellent measurement results. A description of the adaptive fast readout system for wire scanners is presented in this paper.
基金partially supported by the Strategic Priority Research Program of Chinese Academy of Science(No.XDB 34030000)the National Natural Science Foundation of China(Nos.11975293 and 12205348)。
文摘The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are distributed on HFRS for particle identification and beam monitoring.The twin TPCs'readout electronics system operates in a trigger-less mode due to its high counting rate,leading to a challenge of handling large amounts of data.To address this problem,we introduced an event-building algorithm.This algorithm employs a hierarchical processing strategy to compress data during transmission and aggregation.In addition,it reconstructs twin TPCs'events online and stores only the reconstructed particle information,which significantly reduces the burden on data transmission and storage resources.Simulation studies demonstrated that the algorithm accurately matches twin TPCs'events and reduces more than 98%of the data volume at a counting rate of 500 kHz/channel.
基金Supported by National Natural Science Foundation of China(11222552)
文摘A scalable readout system (SRS) is designed to provide a general solution for different micro-pattern gas detectors in various applications. The system mainly consists of three kinds of modules: the ASIC card, the adapter card and the front-end card (FEC). The ASIC cards, mounted with particular ASIC chips, are designed for receiving detector signals. The adapter card is in charge of digitizing the output signals from several ASIC cards. The FEC, edged-mounted with the adapter, has field-programmable gate array (FPGA)-based reconfigurable logic and I/O interfaces, allowing users to choose different ASIC cards and adapters for different experiments, which expands the system to various applications. The FEC transfers data through Gigabit Ethernet protocol realized by a TCP processor (SiTCP) IP core in FPGA. By assembling a flexible number of FECs in parallel through Gigabit Ethernet, the readout system can be tailored to specific sizes to adapt to the experiment scales and readout requirements. In this paper, two kinds of multi-channel ASIC chip, VA140 and AGET, are applied to verify the scalability of this SRS architecture. Based on this VA140 or AGET SRS, one FEC covers 8 ASIC (VA140) cards handling 512 detector channels, or 4 ASIC (AGET) cards handling 256 detector channels, respectively. More FECs can be assembled in crates to handle thousands of detector channels.
基金Supported by National Natural Science Foundation of China (10978002)Youth Innovation Foundation of IHEP(H95461JOU2)
文摘A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is greatly alleviated. Using CCD47-10 as its target CCD, the readout system has achieved 8.6e^- readout noise and 142 eV FWHM at 5.9 keV Mn Kα under a pixel rate of 80 kHz. Also its performance of imaging has been investigated.
文摘This paper describes a low-noise front-end readout circuit for CZT detectors based on TSMC 0.35 um mixed-single CMOS technology;mainly analyzes the noise model of the detector-preamplifier and presents the low-noise circuit schematic of charge sensitive preamplifier and shaper. Considering the parasitical influences, the circuit and layout-design are optimized to reduce noise. The preliminary simulation results show that, the equivalent noise charge (ENC) is 74 e﹣ (rms), noise slope is 9 e﹣/pF, power consumption is 2 mW, and non-linearity
文摘The architecture of a multi-channel front-end system is important for realizing a high-resolution PET system. We propose a novel front-end readout electronic system with TDC to deal with time information for PET system which can easily design the timing control. Each channel consists of a charge preamplifier, slow/fast shaper, discriminator and an analog memory. There are an ADC and a TDC to process the energy information and time information for each channel at the same time. In this paper, the whole system signals flow is all simulated by MATLAB. The simulation results show that the proposed system can process slender current from the detector and achieve the energy and time information. The proposed architecture can be applied to high-resolution PET imaging systems with multi-channel ASICs.
基金supported by the National Natural Science Foundation of China (Nos. 12222512, 12375193, U2031206, U1831206, and U2032209)the Scientific Instrument Developing Project of the Chinese Academy of Sciences (GJJSTD20210009)+1 种基金the CAS Pioneer Hundred Talent Programthe CAS Light of West China Program
文摘The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(ETF)is located in the main ring of the HIRFL-CSR.The gamma detector of the ETF is built to measure emitted gamma rays with energies below 5 MeV in the center-of-mass frame and is planned to measure light fragments with energies up to 300 MeV.The readout electronics for the gamma detector were designed and commissioned.The readout electronics consist of thirty-two front-end cards,thirty-two readout control units(RCUs),one common readout unit,one synchronization&clock unit,and one sub-trigger unit.By using the real-time peak-detection algorithm implemented in the RCU,the data volume can be significantly reduced.In addition,trigger logic selection algorithms are implemented to improve the selection of useful events and reduce the data size.The test results show that the integral nonlinearity of the readout electronics is less than 1%,and the energy resolution for measuring the 60 Co source is better than 5.5%.This study discusses the design and performance of the readout electronics.
基金supported by the National Natural Science Foundation of China(Nos.11927901,12105110,U2032209,12275105)the National Key Research and Development Program of China(Nos.2020YFE0202002,2022YFA1602103)the Fundamental Research Funds for the Central Universities(No.CCNU22QN005)。
文摘The Cooling Storage Ring(CSR)external-target experiment(CEE)will be the first large-scale nuclear physics experiment at the Heavy Ion Research Facility in Lanzhou(HIRFL).A beam monitor has been developed to monitor the beam status and to improve the reconstruction resolution of the primary vertex.Custom-designed pixel charge sensors,named TopmetalCEEv1,are employed in the detector to locate the position of each particle.Readout electronics for the beam monitor were designed,including front-end electronics utilizing the Topmetal-CEEv1 sensors,as well as a readout and control unit that communicates with the DAQ,trigger,and clock systems.A series of tests were performed to validate the functionality and performance of the system,including basic electronic verifications and responses toαparticles and heavy-ion beams.The results show that all designed functions of the readout electronics system work well,and this system could be used for beam monitoring in the CEE experiment.
文摘The development of low-cost,non-enzymatic glucose biosensors is crucial for advancing accessible diabetes management.This paper presents the experimental testing of an extended-gate field-effect transistor(EG-FET)that uses a gold film as the sensing structure.The system innovatively employs a custom-designed inverting operational amplifier circuit for precise signal acquisition and an Arduino Nano platform for real-time data processing and visualization,eliminating the need for expensive laboratory equipment.At the core of the design is a depletion-mode MOSFET,whose current-voltage properties were characterized.The function of the sensor was demonstrated by testing its response to phosphate-buffered saline containing glucose at different concentrations.A clear modulation of the drain current in the linear region of the EG-FET was observed,and a preliminary analysis revealed a linear correlation between the output current and glucose concentration,indicating the system’s potential for quantitative detection.This study successfully validates the feasibility of a compact,cost-effective,and non-enzymatic EG-FET biosensing platform,establishing a solid foundation for future development of point-of-care diagnostic devices.
文摘Novel schemes for a charge sensitive amplifier (CSA) and a CR-(RC), semi-Gaussian shaper in a fully integrated CMOS readout circuit for particle detectors are presented. The CSA is designed with poly-resistors as feedback components to reduce noise. Compared with conventional CSA, the input referred equivalent noise charge(ENC) is simulated to be reduced from 5036e to 2381e with a large detector capacitance of 150pF at the cost of 0.5V output swing loss. The CR-(RC),semi-Gaussian shaper uses MOS transistors in the triode region in series with poly-resistors to compensate process variation without much linearity reduction.
基金The Natural Science Foundation of Jiangsu Province(No.BK2012559)Qing Lan Project of Jiangsu Province
文摘Based on an avalanche photodiode( APD) detecting array working in Geiger mode( GM-APD), a high-performance infrared sensor readout integrated circuit( ROIC) used for infrared 3D( three-dimensional) imaging is proposed. The system mainly consists of three functional modules, including active quenching circuit( AQC), time-to-digital converter( TDC) circuit and other timing controller circuit. Each AQC and TDC circuit together constitutes the pixel circuit. Under the cooperation with other modules, the current signal generated by the GM-APD sensor is detected by the AQC, and the photon time-of-flight( TOF) is measured and converted to a digital signal output to achieve a better noise suppression and a higher detection sensitivity by the TDC. The ROIC circuit is fabricated by the CSMC 0. 5 μm standard CMOS technology. The array size is 8 × 8, and the center distance of two adjacent cells is 100μm. The measurement results of the chip showthat the performance of the circuit is good, and the chip can achieve 1 ns time resolution with a 250 MHz reference clock, and the circuit can be used in the array structure of the infrared detection system or focal plane array( FPA).
基金The project supported by Beijing Electron Positron Collider (BEPCII) Upgrade Project
文摘This article describes the prototype of the read-out subsystem which will be subject to the BESIII data acquisition system. According to the purpose of the BESIII, the event rate will be about 4000 Hz and the data rate up to 50 Mbytes/sec after Level 1 trigger. The read-out subsystem consists of some read-out crates and a read-out computer whose function is to initialize the hardware, to collect the event data from the front-end electronics after Level 1 trigger, to transfer data fragments to the computer in online form through two levels of computer pre-processing and high-speed network transmission. In this model, the crate level read-out implementation is based on the commercial single board computer MVME5100 running the VxWorks operating system. The article outlines the structure of the crate level testing platform of hardware and software. It puts emphasis on the framework of the read-out test model, data process flow and test method at crate level. Especially, it enumerates the key technologies in the process of design and analyses the test results. In addition, results which summarize the performance of the single board computer from the data transferring aspects will be presented.
基金supported by the National Natural Science Foundation of China(No.12222512,U2032209,12075045,12335011,1875097,11975257,62074146,11975115,12205374,12305210,11975292,12005276,12005278,12375193,12227805,12235012,12375191,12005279)the National Key Research and Development Program of China(2021YFA1601300)+13 种基金the Strategic Priority Research Program of Chinese Academy of Sciences(XDB34000000)the CAS Pioneer Hundred Talent Programthe CAS“Light of West China”Programthe Natural Science Foundation of Liaoning Province(No.101300261)the Dalian Science and Technology Innovation Fund(2023JJ12GX013)the Special Projects of the Central Government in Guidance of Local Science and Technology Development(Research and development of three-dimensional prospecting technology based on Cosmic-ray muons)(YDZX20216200001297)the Science and Technology Planning Project of Gansu(20JR10RA645)the Lanzhou University Talent Cooperation Research Funds sponsored by both Lanzhou City(561121203)the Gansu provincial science and technology plan projects for talents(054000029)the Beijing Natural Science Foundation(No.1232033)the Beijing Hope Run Special Fund of Cancer Foundation of China(No.LC2021B23)the Guangdong Major Project of Basic and Applied Basic Research(No.2020B0301030008)the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.GJJSTD20210009)the Youth Innovation Promotion Association CAS(2021450)。
文摘“A Craftsman Must Sharpen His Tools to Do His Job,”said Confucius.Nuclear detection and readout techniques are the foundation of particle physics,nuclear physics,and particle astrophysics to reveal the nature of the universe.Also,they are being increasingly used in other disciplines like nuclear power generation,life sciences,environmental sciences,medical sciences,etc.The article reviews the short history,recent development,and trend of nuclear detection and readout techniques,covering Semiconductor Detector,Gaseous Detector,Scintillation Detector,Cherenkov Detector,Transition Radiation Detector,and Readout Techniques.By explaining the principle and using examples,we hope to help the interested reader underst and this research field and bring exciting information to the community.
基金supported by the National Key R&D Program of China(No.2018YFA0404403)the National Natural Science Foundation of China(Nos.U1967201,11875074,11875073,and 11961141003)the State Key Laboratory of Nuclear Physics and Technology,PKU(No.NPT2020KFY06)。
文摘A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in unstable nuclei.The CAT-TPC consists of an electronic field cage,double-thick gas-electron-multiplier foils,a general-purpose digital data acquisition system,and a newly developed two-dimensional strip-readout structure.The CAT-TPC was operated using a^(4)He(96%)+CO_(2)(4%)gas mixture at 400 mbar.The working gas also serves as an active target for tracking charged particles.The overall performance of the CAT-TPC was evaluated using a collimated a-particle source.A time resolution of less than 20 ns and a position resolution of less than 0.2 mm were observed along the electron drift direction.Threedimensional images of incident trajectories and scattering events can be clearly reconstructed under an angular resolution of approximately 0.45 degree.
基金supported by the National Natural Science Funds of China(Nos.11622327,11273070,11773087,U1631116)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.2014275)the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences(No.XDA15010200)
文摘A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper.
基金supported by the National Key Scientific Instrument and Equipment Development Projects of the National Natural Science Foundation of China(No.41327802)China Mars Project
文摘Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By utilizing a constant fraction discriminator(CFD) and time-to-digital converter(TDC), challenging dynamic range measurements were performed with high time resolution and event rates. CFD was employed to discriminate the TOF signals from the micro-channel plate and channel electron multipliers. TDC based on the combination of counter and OR-gate delay chain was designed in a highreliability flash field programmable gate array. Owing to the non-uniformity of the delay chain, a correction algorithm based on integral nonlinearity compensation was implemented to reduce the time uncertainty. The test results showed that the electronics achieved a low timingerror of < 200 ps in the input range from 35 to 500 m V for the CFD, and a time resolution of ~550 ps with time uncertainty < 180 ps after correction and a time range of6.4 ls for the TDC. The TOF spectrum from an electron beam experiment of the impacting N_2 gas further indicated the good performance of this readout electronic.
基金supported by the National Natural Science Foundation of China(Grant No.11205154)
文摘The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications.