期刊文献+
共找到184篇文章
< 1 2 10 >
每页显示 20 50 100
Design of a silicon charge detector readout system for beam test
1
作者 Xuan Liu Dong-Yu Wang +6 位作者 Wen-Xi Peng Rui Qiao Meng-Long Wu Ming Huang Ya-Qing Liu Dong-Ya Guo Ke Gong 《Nuclear Science and Techniques》 2025年第7期53-63,共11页
The high-energy cosmic radiation detector(HERD)is a planned experimental instrument at the Chinese Space Station.The silicon charge detector(SCD),a subdetector in HERD,is used to detect cosmic-ray nuclei with a high c... The high-energy cosmic radiation detector(HERD)is a planned experimental instrument at the Chinese Space Station.The silicon charge detector(SCD),a subdetector in HERD,is used to detect cosmic-ray nuclei with a high charge resolution.In this study,we present a compact readout electronic system for the SCD that is designed for the HERD heavy-ion beam test.It comprises front-end readout electronics with 200 input channels as well as data acquisition and data management electronics.The test results showed that the SCD readout system had low noise with a silicon-strip detector connected.The dynamic range could be extended from 200 to 1200 fC,and the cosmic-ray test was performed as expected. 展开更多
关键词 HERD Silicon charge detector readout electronics
在线阅读 下载PDF
Design of a high-dynamic-range prototype readout system for VLAST calorimeter 被引量:3
2
作者 Qiang Wan Jian-Hua Guo +10 位作者 Xing Xu Shen Wang Yong-Qiang Zhang Yi-Ming Hu Yan Zhang Xu Pan Xiang Li Chuan Yue Wei Jiang Yu-Xin Cui Deng-Yi Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第10期47-59,共13页
In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-ene... In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6. 展开更多
关键词 VLAST CALORIMETER readout system Front-end electronics Large dynamic range
在线阅读 下载PDF
Readout system for ground-based tests of BGO calorimeter of DAMPE satellite 被引量:2
3
作者 Jun-Bin Zhang Chang-Qing Feng +3 位作者 Si-Yuan Ma Qi Wang Shu-Bin Liu Qi An 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第10期45-50,共6页
A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board ... A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board with a field-programmable gate array to implement the control logic, and a graphical user interface software based on LabWindows/CVI. The system has been successfully applied in a series of ground-based environmental experiments and almost all the performance tests throughout the entire manufacturing processes. These contribute significantly to the development of the BGO calorimeter before being submitted for satellite-level integration. 展开更多
关键词 卫星地面测试 读出系统 BGO LABWINDOWS/CVI 现场可编程门阵列 阻尼 图形用户界面 暗物质粒子
在线阅读 下载PDF
Design of fast adaptive readout system for wire scanners
4
作者 Qian-Shun She Yi Qian +6 位作者 Jie Kong Hai-Bo Yang Hong-Yun Zhao Jing-Zhe Zhang Xiao-Yang Niu Jun-Xia Wu Hong Su 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第1期45-51,共7页
A new wide-range fast readout system capable of adaptive identification is designed for wire scanners,which are used to measure beam profiles and emittance.This system is capable of handling varying current signals wi... A new wide-range fast readout system capable of adaptive identification is designed for wire scanners,which are used to measure beam profiles and emittance.This system is capable of handling varying current signals with Gaussian distributions and current pulses up to 1000 counts/s, as well as an input current range of 1 n A–1 m A. When tested, the resolution was found to exceed 3.68% for full scale, the nonlinearity was found to be less than 0.11%, and the measurement sensibility was found to be less than 5 p A. We believe that the system will play a crucial role in improving the measurement accuracy of beam diagnosis and the efficiency of accelerator operation,as well as decreasing the time required for beam tuning.This system was applied to the beam diagnosis of an injector II prototype for an accelerator-driven subcritical system and produced excellent measurement results. A description of the adaptive fast readout system for wire scanners is presented in this paper. 展开更多
关键词 WIRE SCANNER WEAK current measurement ADAPTIVE identification FRONT-END readout electronics Beam diagnosis
在线阅读 下载PDF
Studies of an event-building algorithm of the readout system for the twin TPCs in HFRS
5
作者 Jing Tian Zhi-Peng Sun +4 位作者 Song-Bo Chang Yi Qian Hong-Yun Zhao Zheng-Guo Hu Xi-Meng Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期82-95,共14页
The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are dist... The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are distributed on HFRS for particle identification and beam monitoring.The twin TPCs'readout electronics system operates in a trigger-less mode due to its high counting rate,leading to a challenge of handling large amounts of data.To address this problem,we introduced an event-building algorithm.This algorithm employs a hierarchical processing strategy to compress data during transmission and aggregation.In addition,it reconstructs twin TPCs'events online and stores only the reconstructed particle information,which significantly reduces the burden on data transmission and storage resources.Simulation studies demonstrated that the algorithm accurately matches twin TPCs'events and reduces more than 98%of the data volume at a counting rate of 500 kHz/channel. 展开更多
关键词 High counting rate Twin TPCs Trigger-less readout electronics Event building Hierarchical data processing
在线阅读 下载PDF
A prototype scalable readout system for micro-pattern gas detectors
6
作者 郑其斌 刘树彬 +3 位作者 田静 李诚 封常青 安琪 《Chinese Physics C》 SCIE CAS CSCD 2016年第8期96-102,共7页
A scalable readout system (SRS) is designed to provide a general solution for different micro-pattern gas detectors in various applications. The system mainly consists of three kinds of modules: the ASIC card, the ... A scalable readout system (SRS) is designed to provide a general solution for different micro-pattern gas detectors in various applications. The system mainly consists of three kinds of modules: the ASIC card, the adapter card and the front-end card (FEC). The ASIC cards, mounted with particular ASIC chips, are designed for receiving detector signals. The adapter card is in charge of digitizing the output signals from several ASIC cards. The FEC, edged-mounted with the adapter, has field-programmable gate array (FPGA)-based reconfigurable logic and I/O interfaces, allowing users to choose different ASIC cards and adapters for different experiments, which expands the system to various applications. The FEC transfers data through Gigabit Ethernet protocol realized by a TCP processor (SiTCP) IP core in FPGA. By assembling a flexible number of FECs in parallel through Gigabit Ethernet, the readout system can be tailored to specific sizes to adapt to the experiment scales and readout requirements. In this paper, two kinds of multi-channel ASIC chip, VA140 and AGET, are applied to verify the scalability of this SRS architecture. Based on this VA140 or AGET SRS, one FEC covers 8 ASIC (VA140) cards handling 512 detector channels, or 4 ASIC (AGET) cards handling 256 detector channels, respectively. More FECs can be assembled in crates to handle thousands of detector channels. 展开更多
关键词 scalable readout system (SRS) micro-pattern gas detectors (MPGD) charge measurement front-endelectronics VA140 AGET
原文传递
Design and optimization of the readout system for X-ray CCDs
7
作者 陆波 崔苇苇 +14 位作者 王于仨 朱玥 张艺 徐玉朋 陈勇 霍嘉 李炜 韩大炜 李茂顺 杨彦佶 王娟 陈田祥 胡渭 李承奎 刘晓艳 《Chinese Physics C》 SCIE CAS CSCD 2012年第9期846-850,共5页
A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is ... A readout system for X-ray CCDs based on an improved architecture is presented; by optimizing several critical circuit blocks along the analog signal chain, the conflict between the readout speed and readout noise is greatly alleviated. Using CCD47-10 as its target CCD, the readout system has achieved 8.6e^- readout noise and 142 eV FWHM at 5.9 keV Mn Kα under a pixel rate of 80 kHz. Also its performance of imaging has been investigated. 展开更多
关键词 CCD X-RAY readout system
原文传递
Design of a Low-Noise Front-End Readout CSP-Shaper System for CZT Detectors 被引量:1
8
作者 Huiming Zeng Tingcun Wei +1 位作者 Bo Gan Wu Gao 《Journal of Signal and Information Processing》 2013年第2期118-122,共5页
This paper describes a low-noise front-end readout circuit for CZT detectors based on TSMC 0.35 um mixed-single CMOS technology;mainly analyzes the noise model of the detector-preamplifier and presents the low-noise c... This paper describes a low-noise front-end readout circuit for CZT detectors based on TSMC 0.35 um mixed-single CMOS technology;mainly analyzes the noise model of the detector-preamplifier and presents the low-noise circuit schematic of charge sensitive preamplifier and shaper. Considering the parasitical influences, the circuit and layout-design are optimized to reduce noise. The preliminary simulation results show that, the equivalent noise charge (ENC) is 74 e﹣ (rms), noise slope is 9 e﹣/pF, power consumption is 2 mW, and non-linearity 展开更多
关键词 CZTdetector FRONT-END readout CSP LOW-NOISE
在线阅读 下载PDF
Design of a Novel Front-End Readout ASIC for PET Imaging System
9
作者 Huiming Zeng Tingcun Wei +1 位作者 Linkai Shen Wu Gao 《Journal of Signal and Information Processing》 2013年第2期129-133,共5页
The architecture of a multi-channel front-end system is important for realizing a high-resolution PET system. We propose a novel front-end readout electronic system with TDC to deal with time information for PET syste... The architecture of a multi-channel front-end system is important for realizing a high-resolution PET system. We propose a novel front-end readout electronic system with TDC to deal with time information for PET system which can easily design the timing control. Each channel consists of a charge preamplifier, slow/fast shaper, discriminator and an analog memory. There are an ADC and a TDC to process the energy information and time information for each channel at the same time. In this paper, the whole system signals flow is all simulated by MATLAB. The simulation results show that the proposed system can process slender current from the detector and achieve the energy and time information. The proposed architecture can be applied to high-resolution PET imaging systems with multi-channel ASICs. 展开更多
关键词 PET FRONT-END readout ELECTRONICS TDC POSITRON Emission TOMOGRAPHY Imaging
暂未订购
Readout electronics for the gamma detector of the HIRFL-CSR external target facility
10
作者 Xian-Qin Li Hai-Bo Yang +10 位作者 Xiao-Meng Ma Chao-Jie Zou Tao Liu Xian-Cai Zhou Duo Yan Yang-Zhou Su Shu-Wen Tang Shi-Tao Wang Yu-Hong Yu Zhi-Yu Sun Cheng-Xin Zhao 《Nuclear Science and Techniques》 2025年第2期71-81,共11页
The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(... The Cooling Storage Ring of the Heavy Ion Research Facility in Lanzhou(HIRFL-CSR)was constructed to study nuclear physics,atomic physics,interdisciplinary science,and related applications.The External Target Facility(ETF)is located in the main ring of the HIRFL-CSR.The gamma detector of the ETF is built to measure emitted gamma rays with energies below 5 MeV in the center-of-mass frame and is planned to measure light fragments with energies up to 300 MeV.The readout electronics for the gamma detector were designed and commissioned.The readout electronics consist of thirty-two front-end cards,thirty-two readout control units(RCUs),one common readout unit,one synchronization&clock unit,and one sub-trigger unit.By using the real-time peak-detection algorithm implemented in the RCU,the data volume can be significantly reduced.In addition,trigger logic selection algorithms are implemented to improve the selection of useful events and reduce the data size.The test results show that the integral nonlinearity of the readout electronics is less than 1%,and the energy resolution for measuring the 60 Co source is better than 5.5%.This study discusses the design and performance of the readout electronics. 展开更多
关键词 HIRFL-CSR Gamma detector External target facility readout electronics readout control unit Common readout unit Peak-detection algorithm
在线阅读 下载PDF
Readout electronics for beam monitor in the External-Target Experiment of CSR
11
作者 Jun Liu Chao-Song Gao +9 位作者 Hu-Lin Wang Zhen Wang Xiang-Ming Sun Ran Chen Fei Yan Bi-Hui You Zi-Xuan Song Cheng-Xin Zhao Guang-Ming Huang Feng Liu 《Nuclear Science and Techniques》 2025年第5期113-125,共13页
The Cooling Storage Ring(CSR)external-target experiment(CEE)will be the first large-scale nuclear physics experiment at the Heavy Ion Research Facility in Lanzhou(HIRFL).A beam monitor has been developed to monitor th... The Cooling Storage Ring(CSR)external-target experiment(CEE)will be the first large-scale nuclear physics experiment at the Heavy Ion Research Facility in Lanzhou(HIRFL).A beam monitor has been developed to monitor the beam status and to improve the reconstruction resolution of the primary vertex.Custom-designed pixel charge sensors,named TopmetalCEEv1,are employed in the detector to locate the position of each particle.Readout electronics for the beam monitor were designed,including front-end electronics utilizing the Topmetal-CEEv1 sensors,as well as a readout and control unit that communicates with the DAQ,trigger,and clock systems.A series of tests were performed to validate the functionality and performance of the system,including basic electronic verifications and responses toαparticles and heavy-ion beams.The results show that all designed functions of the readout electronics system work well,and this system could be used for beam monitoring in the CEE experiment. 展开更多
关键词 CEE Beam monitor Topmetal-CEEv1 readout electronics
在线阅读 下载PDF
Development and Characterization of a Non-Enzymatic Glucose Biosensor Based on a Gold Film EG-FET and an Inverting Amplifier Readout Circuit
12
作者 Xintai Dong 《Journal of Electronic Research and Application》 2025年第6期302-312,共11页
The development of low-cost,non-enzymatic glucose biosensors is crucial for advancing accessible diabetes management.This paper presents the experimental testing of an extended-gate field-effect transistor(EG-FET)that... The development of low-cost,non-enzymatic glucose biosensors is crucial for advancing accessible diabetes management.This paper presents the experimental testing of an extended-gate field-effect transistor(EG-FET)that uses a gold film as the sensing structure.The system innovatively employs a custom-designed inverting operational amplifier circuit for precise signal acquisition and an Arduino Nano platform for real-time data processing and visualization,eliminating the need for expensive laboratory equipment.At the core of the design is a depletion-mode MOSFET,whose current-voltage properties were characterized.The function of the sensor was demonstrated by testing its response to phosphate-buffered saline containing glucose at different concentrations.A clear modulation of the drain current in the linear region of the EG-FET was observed,and a preliminary analysis revealed a linear correlation between the output current and glucose concentration,indicating the system’s potential for quantitative detection.This study successfully validates the feasibility of a compact,cost-effective,and non-enzymatic EG-FET biosensing platform,establishing a solid foundation for future development of point-of-care diagnostic devices. 展开更多
关键词 EG-FET Glucose detection Non-enzymatic biosensor readout circuit
在线阅读 下载PDF
A Fully Integrated CMOS Readout Circuit for Particle Detectors 被引量:2
13
作者 张雅聪 陈中建 +2 位作者 鲁文高 赵宝瑛 吉利久 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2007年第2期182-188,共7页
Novel schemes for a charge sensitive amplifier (CSA) and a CR-(RC), semi-Gaussian shaper in a fully integrated CMOS readout circuit for particle detectors are presented. The CSA is designed with poly-resistors as ... Novel schemes for a charge sensitive amplifier (CSA) and a CR-(RC), semi-Gaussian shaper in a fully integrated CMOS readout circuit for particle detectors are presented. The CSA is designed with poly-resistors as feedback components to reduce noise. Compared with conventional CSA, the input referred equivalent noise charge(ENC) is simulated to be reduced from 5036e to 2381e with a large detector capacitance of 150pF at the cost of 0.5V output swing loss. The CR-(RC),semi-Gaussian shaper uses MOS transistors in the triode region in series with poly-resistors to compensate process variation without much linearity reduction. 展开更多
关键词 charge sensitive amplifier SHAPER readout circuit noise optimization
在线阅读 下载PDF
Design and implementation of GM- APD array readout circuit for infrared imaging
14
作者 吴金 袁德军 +3 位作者 王灿 陈浩 郑丽霞 孙伟锋 《Journal of Southeast University(English Edition)》 EI CAS 2016年第1期11-15,共5页
Based on an avalanche photodiode( APD) detecting array working in Geiger mode( GM-APD), a high-performance infrared sensor readout integrated circuit( ROIC) used for infrared 3D( three-dimensional) imaging is ... Based on an avalanche photodiode( APD) detecting array working in Geiger mode( GM-APD), a high-performance infrared sensor readout integrated circuit( ROIC) used for infrared 3D( three-dimensional) imaging is proposed. The system mainly consists of three functional modules, including active quenching circuit( AQC), time-to-digital converter( TDC) circuit and other timing controller circuit. Each AQC and TDC circuit together constitutes the pixel circuit. Under the cooperation with other modules, the current signal generated by the GM-APD sensor is detected by the AQC, and the photon time-of-flight( TOF) is measured and converted to a digital signal output to achieve a better noise suppression and a higher detection sensitivity by the TDC. The ROIC circuit is fabricated by the CSMC 0. 5 μm standard CMOS technology. The array size is 8 × 8, and the center distance of two adjacent cells is 100μm. The measurement results of the chip showthat the performance of the circuit is good, and the chip can achieve 1 ns time resolution with a 250 MHz reference clock, and the circuit can be used in the array structure of the infrared detection system or focal plane array( FPA). 展开更多
关键词 infrared 3D(three-dimensional) imaging readout integrated circuit(ROIC) Geiger mode avalanche photodiode active quenching circuit(AQC) time-to-digital converter(TDC)
在线阅读 下载PDF
A Prototype of the Read-out Subsystem of the BESIII DAQ Based on PowerPC
15
作者 陶宁 初元萍 +1 位作者 金革 赵京伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期3065-3068,共4页
This article describes the prototype of the read-out subsystem which will be subject to the BESIII data acquisition system. According to the purpose of the BESIII, the event rate will be about 4000 Hz and the data rat... This article describes the prototype of the read-out subsystem which will be subject to the BESIII data acquisition system. According to the purpose of the BESIII, the event rate will be about 4000 Hz and the data rate up to 50 Mbytes/sec after Level 1 trigger. The read-out subsystem consists of some read-out crates and a read-out computer whose function is to initialize the hardware, to collect the event data from the front-end electronics after Level 1 trigger, to transfer data fragments to the computer in online form through two levels of computer pre-processing and high-speed network transmission. In this model, the crate level read-out implementation is based on the commercial single board computer MVME5100 running the VxWorks operating system. The article outlines the structure of the crate level testing platform of hardware and software. It puts emphasis on the framework of the read-out test model, data process flow and test method at crate level. Especially, it enumerates the key technologies in the process of design and analyses the test results. In addition, results which summarize the performance of the single board computer from the data transferring aspects will be presented. 展开更多
关键词 BESIII DAQ readout system single board computer VMEBUS DMA transfer
在线阅读 下载PDF
Advances in nuclear detection and readout techniques 被引量:29
16
作者 Rui He Xiao‑Yang Niu +48 位作者 Yi Wang Hong‑Wei Liang Hong‑Bang Liu Ye Tian Hong‑Lin Zhang Chao‑Jie Zou Zhi‑Yi Liu Yun‑Long Zhang Hai‑Bo Yang Ju Huang Hong‑Kai Wang Wei‑Jia Han Bei Cao Gang Chen Cong Dai Li‑Min Duan Rui‑Rui Fan Fang‑Fa Fu Jian‑Hua Guo Dong Han Wei Jiang Xian‑Qin Li Xin Li Zhuo‑Dai Li Yu‑Tie Liang Shun Liao De‑Xu Lin Cheng‑Ming Liu Guo‑Rui Liu Jun‑Tao Liu Ze Long Meng‑Chen Niu Hao Qiu Hu Ran Xiang‑Ming Sun Bo‑Tan Wang Jia Wang Jin‑Xiang Wang Qi‑Lin Wang Yong‑Sheng Wang Xiao‑Chuan Xia Hao‑Qing Xie He‑Run Yang Hong Yin Hong Yuan Chun‑Hui Zhang Rui‑Guang Zhao Ran Zheng Cheng‑Xin Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期281-358,共78页
“A Craftsman Must Sharpen His Tools to Do His Job,”said Confucius.Nuclear detection and readout techniques are the foundation of particle physics,nuclear physics,and particle astrophysics to reveal the nature of the... “A Craftsman Must Sharpen His Tools to Do His Job,”said Confucius.Nuclear detection and readout techniques are the foundation of particle physics,nuclear physics,and particle astrophysics to reveal the nature of the universe.Also,they are being increasingly used in other disciplines like nuclear power generation,life sciences,environmental sciences,medical sciences,etc.The article reviews the short history,recent development,and trend of nuclear detection and readout techniques,covering Semiconductor Detector,Gaseous Detector,Scintillation Detector,Cherenkov Detector,Transition Radiation Detector,and Readout Techniques.By explaining the principle and using examples,we hope to help the interested reader underst and this research field and bring exciting information to the community. 展开更多
关键词 Silicon detector Wide bandgap detector Time projection chamber(TPC) Multigap resistive plate chamber detector(MRPC) Scintillation detector CALORIMETERS Cherenkov detector Transition radiation detector Artificial intelligence Trigger-less readout
在线阅读 下载PDF
Performance of the CAT-TPC based on two-dimensional readout strips 被引量:6
17
作者 Li-Sheng Yang Jin-Yan Xu +12 位作者 Qi-Te Li Bin-Fei Ji Zi-Wei Cai Jia-Xing Han Shi-Wei Bai Yan-Lin Ye Xiao-Fei Yang Chen-Gui Lu Ning-Tao Zhang Xiao-Dong Tang Jian Gao Hong-Yi Wu Zhong Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第8期78-84,共7页
A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in uns... A gas detector 140×140×140 mm^(3)in size,termed the compact active target time projection chamber(CAT-TPC),was developed in this study to measure resonant scattering associated with cluster structures in unstable nuclei.The CAT-TPC consists of an electronic field cage,double-thick gas-electron-multiplier foils,a general-purpose digital data acquisition system,and a newly developed two-dimensional strip-readout structure.The CAT-TPC was operated using a^(4)He(96%)+CO_(2)(4%)gas mixture at 400 mbar.The working gas also serves as an active target for tracking charged particles.The overall performance of the CAT-TPC was evaluated using a collimated a-particle source.A time resolution of less than 20 ns and a position resolution of less than 0.2 mm were observed along the electron drift direction.Threedimensional images of incident trajectories and scattering events can be clearly reconstructed under an angular resolution of approximately 0.45 degree. 展开更多
关键词 AT-TPC readout strips Guard ring Three-dimensional image
在线阅读 下载PDF
High-resolution pixelated CdZnTe detector prototype system for solar hard X-ray imager 被引量:2
18
作者 Shen Wang Jian-Hua Guo +1 位作者 Yan Zhang Wei Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期53-58,共6页
A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for fut... A multichannel low-noise electronic prototype system was designed for a pixelated CdZnTe detector. This system is the result of preliminary work on a solar hard X-ray imager, which is one of the three payloads for future solar observations satellite-Advanced Space-based Solar Observatory(ASO-S). A new charge-sensitive amplifier application-specific integrated circuit, VATA450.3, with an on-chip analog-to-digital converter, is used to read out 8×8 anode pixel signals. Two CdZnTe detectors with a thickness of 2 mm and 5 mm were tested. The 2-mm-thick detector achieved energy resolution better than 5%(fullwidth at half-maximum, FWHM) at 59.5 keV, and the 5-mm-thick detector had better resolution than 1.2%(FWHM) at 662 keV. The design and test results of the prototype system are discussed in this paper. 展开更多
关键词 CDZNTE readout system SOLAR observation HARD X-ray IMAGER
在线阅读 下载PDF
Readout electronics of a prototype time-of-flight ion composition analyzer for space plasma 被引量:3
19
作者 Di Yang Zhe Cao +4 位作者 Xin-Jun Hao Yi-Ren Li Shu-Bin Liu Chang-Qing Feng Qi An 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第4期98-107,共10页
Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By... Readout electronics is developed for a prototype time-of-flight(TOF) ion composition spectrometer for in situ measurement of the mass/charge distributions of major ion species from 200 to 100 ke V/e in space plasma.By utilizing a constant fraction discriminator(CFD) and time-to-digital converter(TDC), challenging dynamic range measurements were performed with high time resolution and event rates. CFD was employed to discriminate the TOF signals from the micro-channel plate and channel electron multipliers. TDC based on the combination of counter and OR-gate delay chain was designed in a highreliability flash field programmable gate array. Owing to the non-uniformity of the delay chain, a correction algorithm based on integral nonlinearity compensation was implemented to reduce the time uncertainty. The test results showed that the electronics achieved a low timingerror of < 200 ps in the input range from 35 to 500 m V for the CFD, and a time resolution of ~550 ps with time uncertainty < 180 ps after correction and a time range of6.4 ls for the TDC. The TOF spectrum from an electron beam experiment of the impacting N_2 gas further indicated the good performance of this readout electronic. 展开更多
关键词 Space plasma Ion composition ANALYZER readout electronics Constant FRACTION DISCRIMINATOR Time-to-digital converter
在线阅读 下载PDF
Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector 被引量:3
20
作者 Er-Lei Chen Chang-Qing Feng +4 位作者 Shu-Bin Liu Chun-Feng Ye Dong-Dong Jin Jian Lian Hui-Jun Hu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第1期94-99,共6页
The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly co... The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications. 展开更多
关键词 Energy and time measurement SOFT X-ray detection Silicon DRIFT DETECTOR readout ELECTRONICS
在线阅读 下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部