期刊文献+
共找到119篇文章
< 1 2 6 >
每页显示 20 50 100
Simulation study of energy resolution with changing pixel size for radon monitor based on Topmetal-Ⅱ^- TPC 被引量:6
1
作者 Meng-Yao Huang Hua Pei +1 位作者 Xiang-Ming Sun Shu-Guang Zou 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第1期49-57,共9页
In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector—a high sensitivity, low cost, and real-time radon monitor based on a Topmetal-Ⅱ^- time projection chamber(TPC). T... In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector—a high sensitivity, low cost, and real-time radon monitor based on a Topmetal-Ⅱ^- time projection chamber(TPC). This monitor was designed to improve spatial resolution for detecting radon alpha particles using Topmetal-Ⅱ^- sensors assembled by a 0.35 lm CMOS integrated circuit process.Owing to concerns that small pixel size might have the side effect of worsening energy resolution due to lower signalto-noise ratio, a Geant4-based simulation was used to investigate the dependence of energy resolution on pixel sizes ranging from 60 to 600 lm. A non-monotonic trend in this region shows the combined effect of pixel size and threshold on pixels, analyzed by introducing an empirical expression. Pixel noise contributes 50 keV full-width at half-maximum energy resolution for 400 lm pixel size at 1–4σ threshold that is comparable to the energy resolution caused by energy fluctuations in the TPC ionization process( ~20 keV). The total energy resolution after combining both factors is estimated to be 54 keV for a pixel size of 400 lm at 1–4σ threshold. The analysis presented in this paper would help choosing suitable pixel size for future pixelated detectors. 展开更多
关键词 GEANT4 Energy resolution PIXEL size radon monitor Topmetal
在线阅读 下载PDF
Monitoring and Evaluation on Indoor Radon Concentration in a District of Xi'an
2
作者 Huiping Guo Wenhui Lv +2 位作者 Ning Lv Lei Zhang Zhihao Wei 《Meteorological and Environmental Research》 CAS 2013年第10期25-27,31,共4页
[Objective] The research aimed to monitor and evaluate indoor radon concentration in one district of Xi'an City. r Method] In order to master the effective dose per year caused by natural radiation to local residents... [Objective] The research aimed to monitor and evaluate indoor radon concentration in one district of Xi'an City. r Method] In order to master the effective dose per year caused by natural radiation to local residents, the investigation about the level of indoor radon in one district of Xi'an was developed. Based on the proper monitoring scheme, some typical living rooms were sampled. Through the measurement result, the effects of different factors on radon concentration were obtained. Finally, the radon concentration was transferred into the effective dose per year of local residents. [ Result] Indoor radon concentration in the district was during 49.680 -128.856 Bq/m3, and average concentration in each building was within 100 Bq/m3, which belonged to normal range. When sunny day became rainy day, radon concentration firstly had a rise trend. If continuous rainy weather appeared, indoor radon concentration gradually declined. When other conditions were same, indoor radon concentration under window closing was significantly higher than that under window opening. Indoor radon concentration had a decline trend from 13:00 to 20:00 and a rise trend from 01:00 to 06:00. Condusion The district belonged to radon safety house. To protect residents' health to the maximum extent, according to transfer change rule of the radon, window should be opened to ventilate in the morning when radon concentration was higher. 展开更多
关键词 radon concentration monitoring and evaluation Variation regulation Effective dose China
在线阅读 下载PDF
双通道高灵敏放射性气溶胶在线监测仪的研制
3
作者 商洁 冒学勇 +3 位作者 杨屹 张艳婷 张富国 杨柳 《辐射防护》 北大核心 2025年第4期337-342,共6页
针对核设施放射性气溶胶监测既可快速预警又可达到接近实验室离线分析的灵敏度的需求,研制了一款高灵敏放射性气溶胶在线监测仪。通过采取即时与延时双通道结构设计,增加采样轨道长度,优化即时道响应时间,综合应用衰变法、能量甄别和α... 针对核设施放射性气溶胶监测既可快速预警又可达到接近实验室离线分析的灵敏度的需求,研制了一款高灵敏放射性气溶胶在线监测仪。通过采取即时与延时双通道结构设计,增加采样轨道长度,优化即时道响应时间,综合应用衰变法、能量甄别和α/β比值的氡扣除技术,降低探测限值。一台设备可同时满足快速响应(即时道响应时间1 min)与高灵敏度(延迟道探测限值α为10-4Bq/m^(3),β为10^(-2)Bq/m^(3))特性,巧妙地解决了常规气溶胶监测中两个参数相悖的问题。相比传统气溶胶在线监测仪,α与β探测限值均提高了2个量级,且降低了当前离线取样的实验室分析工作量和受照风险。 展开更多
关键词 高灵敏 在线监测 放射性气溶胶 响应时间 氡补偿
在线阅读 下载PDF
“测氡-磁”法探测小窑自然发火技术的应用研究
4
作者 胡相明 洪海博 +4 位作者 董浩 吴佰谦 孙自超 王伟 张茜 《煤炭科学技术》 北大核心 2025年第2期200-210,共11页
山西小窑煤矿自然发火区域存在火源多且分布范围较广、火源位置隐蔽难以准确探测、漏风通道多、难以防治的实际问题。为了准确探测火源位置及范围,首先,从自然发火区域探测手段的探测机理开展研究,基于测氡法与磁法探测火区基础理论,提... 山西小窑煤矿自然发火区域存在火源多且分布范围较广、火源位置隐蔽难以准确探测、漏风通道多、难以防治的实际问题。为了准确探测火源位置及范围,首先,从自然发火区域探测手段的探测机理开展研究,基于测氡法与磁法探测火区基础理论,提出了地面“测氡-磁”联合技术探测原理对小窑火源的位置与范围进行精确探测;其次,使用FD213α能谱氡测量仪和GSM-19T磁力仪现场采集小窑隐蔽火源数据,采用地面“测氡-磁”联合技术对采集数据处理分析,综合圈定小窑隐蔽火源的位置与范围,并利用井下测温与测气钻孔,结合初步探测结果和井下巷道分布情况,对火源位置进行了核实;最后采用钻孔注浆技术进行火区治理,并采取束管气体监测和复测氡法联合技术对火区治理效果进行检测。试验结果发现:井下测温与测气钻孔结果成功验证“测氡-磁”联合技术圈定的隐蔽火源的位置与范围,本次试验共圈定隐蔽火区面积约213 m^(2);钻孔注浆火区治理工作累积充填材料约1 862 m~3;治理效果检测表明圈定火区内部指标气体CO体积分数降为0,氡浓度趋于正常水平,治理工作取得良好的效果。 展开更多
关键词 小煤窑隐蔽火区 火源测探 磁法与测氡联用法 钻孔注浆技术 束管监测
在线阅读 下载PDF
广西典型锆钛矿加工企业辐射环境监测及辐射安全管理建议
5
作者 林晨 许明发 +3 位作者 张莹 崔伦 彭文斌 吴易超 《中国辐射卫生》 2025年第2期283-292,共10页
目的 为广西伴生放射性矿开发利用企业制定科学、合理的监管办法提供技术支撑。方法 集中对广西多家锆钛矿企业在选矿、加工等生产环节中产生的固体物料进行放射性核素分析,对流出物进行放射性水平测量,对企业厂界及周边环境保护目标的... 目的 为广西伴生放射性矿开发利用企业制定科学、合理的监管办法提供技术支撑。方法 集中对广西多家锆钛矿企业在选矿、加工等生产环节中产生的固体物料进行放射性核素分析,对流出物进行放射性水平测量,对企业厂界及周边环境保护目标的环境空气氡浓度水平和环境γ辐射剂量率进行测量分析。结果 厂界及周边环境γ辐射空气吸收剂量率、氡及其子体浓度、地表水、气溶胶放射性水平均处于正常水平;厂区内原矿、锆英产品、金红石产品和独居石产品中238U、232Th、226Ra核素比活度较高,相对应车间中的γ辐射空气吸收剂量率也较高,最大区域为锆英金红车间;锆英产品、金红石、独居石等物料均有一定的氡析出。结论 尾砂放射性水平达到可免于监管,企业不产生放射性固体废物;需要重视高辐射剂量率区域工作人员个人剂量问题。 展开更多
关键词 伴生放射性矿 辐射环境监测 辐射安全 氡析出率
原文传递
建材析出氡浓度持续监测研究及其应用 被引量:2
6
作者 范增伟 李婷 +1 位作者 段金松 武旭东 《世界核地质科学》 CAS 2024年第3期604-610,共7页
建筑材料析出的氡扩散至房屋内部导致室内氡浓度增加,对居住者产生健康威胁。提出了一种建材析出氡浓度持续监测方法,将自制具有不同放射性含量的建材实验样品块和氡浓度持续监测系统放置于密闭恒温容器内进行长时间监测,结果表明在2~9 ... 建筑材料析出的氡扩散至房屋内部导致室内氡浓度增加,对居住者产生健康威胁。提出了一种建材析出氡浓度持续监测方法,将自制具有不同放射性含量的建材实验样品块和氡浓度持续监测系统放置于密闭恒温容器内进行长时间监测,结果表明在2~9 h密封时间内建材析出氡浓度与密封时间的线性相关系数为0.99以上,连续密封72 h时氡浓度的析出量仍在增加,未出现饱和趋势。将氡浓度持续监测系统应用于室内氡浓度监测,当浓度超过报警阈值后自动开启通风系统进行空气置换,可实现快速排氡,有效改善室内空气质量,避免居住者长期暴露在高氡浓度环境中。 展开更多
关键词 室内氡浓度 建材氡析出 氡浓度监测 静态测量
在线阅读 下载PDF
浙江省某市地铁氡浓度监测及其对相关工作人员染色体畸变和微核的影响
7
作者 宣志强 黄芯瑜 +7 位作者 赖忠俊 郭佳娣 郝小吉 俞顺飞 曹艺耀 王东航 张舵 聂继华 《环境与职业医学》 CAS CSCD 北大核心 2024年第9期1025-1031,共7页
[背景]过量氡暴露被认为是导致肺癌的第二大危险因素。浙江省某市自地铁开通运行以来,地铁站放射性气体氡暴露水平及能否造成职业人群健康影响,已成为公众关注的重要问题之一。[目的]调查浙江省某市地下轨道交通的氡浓度,探讨氡暴露对... [背景]过量氡暴露被认为是导致肺癌的第二大危险因素。浙江省某市自地铁开通运行以来,地铁站放射性气体氡暴露水平及能否造成职业人群健康影响,已成为公众关注的重要问题之一。[目的]调查浙江省某市地下轨道交通的氡浓度,探讨氡暴露对职业人群染色体畸变和微核的影响。[方法]选择某市2条地铁线路,对55个站点的车控室连续监测1年,对55个站点的110个售票处和55个安检处监测1个时段(3月16日—6月14日),监测方法参照HJ 1212—2021《环境空气中氡的测量方法》,比较不同岗位类型监测点、地铁线路和季节间氡浓度之间的差异。同时对3个岗位类型监测点的165名工作人员开展外周血淋巴细胞染色体畸变和微核检测,检测方法参照GBZ/T 248—2014《放射工作人员职业健康检查外周血淋巴细胞染色体畸变检测与评价》和GBZ/T 328—2023《放射工作人员职业健康检查外周血淋巴细胞微核检测方法与受照剂量估算标准》,并进行影响因素分析。[结果]浙江省某市地铁氡浓度范围为10~320 Bq·m^(-3),均低于国家标准规定公共地下建筑氡浓度控制水平(≤400 Bq·m^(-3))。不同线路、不同岗位类型监测点、不同时段氡的放射性水平间差异具有统计学意义(P<0.05)。对165个研究对象进行染色体畸变和微核分析,染色体畸变和微核率分别为0.224%和0.024%,不同岗位(车控室、售票处、安检处)之间染色体畸变和微核率存在差异(P<0.05),但均低于相应国家标准异常率限值标准,未观察到岗位与染色体畸变、微核之间的相关性(P>0.05)。单因素分析显示不同年龄、地铁站工龄、吸烟者的染色体畸变与微核有差异(P<0.05),多因素分析未观察到上述因素对染色体畸变和微核的影响(P>0.05)。[结论]地铁站氡浓度处于正常水平;地铁岗位对染色体畸变和微核有影响,但染色体畸变率和微核率异常率明显低于国家标准规定限值,因此地铁氡暴露尚未对工作人员造成健康危害影响。 展开更多
关键词 地铁 监测 染色体畸变 微核 影响因素
原文传递
Detailed Study of Radon Spatial Anomaly in Tlamacas Mountain Area, Volcano Popocatepetl, Mexico
8
作者 Anatolyi Kotsarenko Vsevolod Yutsis +1 位作者 Vladimir Grimalsky Svetlana Koshevaya 《Open Journal of Geology》 2016年第3期158-164,共7页
Results of a soil radon survey accomplished by 2 different methods during 2 different periods in the area of Tlamacas Mountain are presented. The first study, carried out from 15-APR-2010 to 09-MAY-2010 in 30 measurem... Results of a soil radon survey accomplished by 2 different methods during 2 different periods in the area of Tlamacas Mountain are presented. The first study, carried out from 15-APR-2010 to 09-MAY-2010 in 30 measurement sites by means of CR39 solid state nuclear detectors, shows 2 active zones with intensive radon emanation with a characteristic dimension of about 300 meters located in the northwestern and western parts of the Mountain. The second survey, made on 05-JUL-2011 in 23 measurement sites with 10 min sampling by a SARAD RTM 1688 Radon/Thoron monitor, in contrast, revealed a sizeable area depleted in radon and 3 active areas of increased radon release in the lateral Mountain sides. These observed phenomena strengthen our assumption about the presence of an active geological structure in Tlamacas Mountain connected with a geodynamical processes in volcano Popocatepetl. 展开更多
关键词 radon Tlamacas Mexico ANOMALY Popocatepetl monitorING
在线阅读 下载PDF
Radon Concentration Levels Estimation in Some Drinking Water Samples from Communities around Lumwana Mine in North Western Province of Zambia
9
作者 R. Katebe Z. Phiri E. Nyirenda 《材料科学与工程(中英文A版)》 2017年第1期9-18,共10页
在线阅读 下载PDF
全国标准级测氡仪的统一校准及低浓度测量比对 被引量:2
10
作者 孙昌昊 杨志杰 +3 位作者 刘玫玲 刘皓然 张健 梁珺成 《计量学报》 CSCD 北大核心 2024年第2期279-284,共6页
为了提升国内氡计量能力,组织了全国11家已建标实验室的标准级测氡仪开展统一校准。在校准的基础上,开展了低浓度测量比对,分析参比实验室在低浓度水平处进行量值传递的可行性。统一校准在700~3000 Bq/m^(3)氡浓度量级进行,氡浓度参考... 为了提升国内氡计量能力,组织了全国11家已建标实验室的标准级测氡仪开展统一校准。在校准的基础上,开展了低浓度测量比对,分析参比实验室在低浓度水平处进行量值传递的可行性。统一校准在700~3000 Bq/m^(3)氡浓度量级进行,氡浓度参考值可溯源至氡活度基准装置,不确定度为1.6%(k=2)。各标准级测氡仪的体积活度响应范围为0.93~1.02,不确定度范围为2.2%~3.6%(k=2)。低浓度比对在100~400 Bq/m^(3)氡浓度量级进行,大部分标准级测氡仪的|E_(n)|值小于1,通过优化量传的策略,标准级测氡仪在100 Bq/m^(3)以上开展量值传递是可行的;但在100 Bq/m^(3)或以下浓度量级开展量值传递,各参比实验室仍需提升测量能力及氡浓度调控能力。 展开更多
关键词 电离辐射计量 氡体积活度 标准级测氡仪 校准 国内比对
在线阅读 下载PDF
高氡浓度地震监测泉在标准仪器校准方法中的应用研究
11
作者 李娜 祖丽皮牙·艾尼瓦尔 +2 位作者 李新勇 任宏微 黄建明 《内陆地震》 2024年第3期250-257,共8页
基于水氡浓度为20000~100000 Bq·m^(-3)的新09泉、新10泉和新15泉,利用国际刻度参考装置Alpha GUARD测氡仪及其水氡测量组件,开展标准仪器传递校准实验研究,校准K值相对误差分别为3.60%、-0.81%及2.09%。实验结果与氡气固体源校准... 基于水氡浓度为20000~100000 Bq·m^(-3)的新09泉、新10泉和新15泉,利用国际刻度参考装置Alpha GUARD测氡仪及其水氡测量组件,开展标准仪器传递校准实验研究,校准K值相对误差分别为3.60%、-0.81%及2.09%。实验结果与氡气固体源校准结果对比表明,水氡浓度在20000 Bq·m^(-3)以上水样可以通过标准仪器校准新方法检验,且利用不同水氡浓度的泉水不会影响校准结果准确性。新疆地球物理观测中心可利用高氡浓度的日常监测泉,将Alpha GUARD测氡仪作为标准仪器对FD-125型氡钍分析仪进行校准,从而替代固体氡源校准。本研究为地震监测氡观测的校准新方法操作技术规程及推广试用提供了数据支撑。 展开更多
关键词 地震监测 水氡 K值 标定方法 Alpha GUARD测氡仪
在线阅读 下载PDF
测氡仪校准因子的不确定度分析 被引量:1
12
作者 田兴宇 张雄杰 +2 位作者 庞柳青 李云洋 苏建文 《辐射防护》 CAS CSCD 北大核心 2024年第2期141-146,共6页
测氡仪校准因子的不确定度是评判校准结果的重要参数,是测氡仪测量结果评定的重要依据。对以氡室作为辅助装置进行测氡仪校准时被测仪器校准因子的不确定度来源进行分析,测得了校准因子的相对标准不确定度。结果显示,测氡仪校准因子的... 测氡仪校准因子的不确定度是评判校准结果的重要参数,是测氡仪测量结果评定的重要依据。对以氡室作为辅助装置进行测氡仪校准时被测仪器校准因子的不确定度来源进行分析,测得了校准因子的相对标准不确定度。结果显示,测氡仪校准因子的不确定度主要影响因素有标准仪器和被测仪器的重复性不确定度、标准仪器校准因子和其年稳定性的不确定度、氡室装置测试区域不均匀性的不确定等。最终,各测量点下被测测氡仪校准因子的相对标准不确定度分别为4.1%、3.6%、3.3%。 展开更多
关键词 测氡仪 校准 不确定度分析
在线阅读 下载PDF
基于微渗漏机制的甲烷氡气异常特征及其在煤矿隐蔽致灾因素勘探中的意义 被引量:1
13
作者 贺会策 孙春岩 +4 位作者 唐侥 张宗庆 冶北北 赵浩 王栋琳 《物探与化探》 CAS 2024年第5期1409-1423,共15页
煤矿隐蔽致灾因素是指隐伏在煤层及其围岩内不易直接发现而开采过程中可能诱发矿山灾难的地质构造和不良地质体。甲烷和氡气是煤矿中常见的有害气体,其异常释放往往伴随着煤层的不良构造与瓦斯聚集等隐蔽灾害。本文以阳泉新元煤矿为工作... 煤矿隐蔽致灾因素是指隐伏在煤层及其围岩内不易直接发现而开采过程中可能诱发矿山灾难的地质构造和不良地质体。甲烷和氡气是煤矿中常见的有害气体,其异常释放往往伴随着煤层的不良构造与瓦斯聚集等隐蔽灾害。本文以阳泉新元煤矿为工作区,首次基于微渗漏机制,优选了对隐蔽致灾地质因素敏感性强的甲烷、氡气两种地球化学指标,探讨土壤甲烷和氡气指标地球化学异常特征对煤矿隐蔽致灾因素的指示作用,通过动态监测(408个点位的土壤游离烃甲烷与氡气指标)和面积测量(416个点位的土壤游离烃甲烷、酸解烃甲烷指标以及651个点位的土壤氡气指标)的实测数据,获取了下伏含水破碎带、煤层气渗漏带、微构造裂隙带、陷落柱环绕带等致灾因素分布的地球化学响应特征;同时与广域电磁法开展联合勘探分析,完成煤矿构造类、瓦斯聚集类隐蔽致灾因素的验证识别,推测圈定出工作区潜在致灾因素的分布区段,验证了烃类微渗漏理论在煤矿隐蔽致灾因素勘探中的适用性与实用性,为甲烷、氡气地球化学指标在煤矿隐蔽致灾因素普查勘探中的广泛应用奠定了基础,对于提高煤矿安全生产具有重要意义。 展开更多
关键词 煤矿隐蔽致灾因素 酸解烃 游离烃 土壤氡气 动态监测 山西阳泉新元煤矿
在线阅读 下载PDF
某深埋地铁车站内部环境质量监测分析 被引量:1
14
作者 禹富偲 许祺航 《智慧轨道交通》 2024年第1期68-73,共6页
地铁车站的环境质量关系到车站内人员的生理健康,现今已引起了人们的高度重视。然而,目前许多地铁车站自身内部环境监测系统存在监测项目少、测点布置稀疏等问题,并不能全面反映地铁车站内部环境质量随时间、空间及通风条件等因素的变... 地铁车站的环境质量关系到车站内人员的生理健康,现今已引起了人们的高度重视。然而,目前许多地铁车站自身内部环境监测系统存在监测项目少、测点布置稀疏等问题,并不能全面反映地铁车站内部环境质量随时间、空间及通风条件等因素的变化规律。通过在某深埋车站内布置综合环境监测网络,实现了对于环境质量主要指标(温湿度、空气成分及放射性元素氡气)的持续实时监测。通过对监测结果进行统计分析,获得了上述环境质量指标随时间和空间的变化规律,明确了影响地铁车站内部环境质量的关键因素。监测结果表明:该车站主要环境指标大部分时段内满足相关标准要求,放射性元素风险较低,环境质量处于较好的状态;受车站通风空调设备分布的影响,车站内不同区域和不同高度的环境略有区别;环境质量受人员活动和车站通风空调设备工作状态等因素的影响。 展开更多
关键词 环境质量 监测网络 数据分析 深埋地铁车站 氡气
在线阅读 下载PDF
α能谱法测量^(222)Rn/^(220)Rn气体活度浓度过程中的拖尾修正 被引量:8
15
作者 马若云 张磊 +2 位作者 郭璐 张亮 郭秋菊 《原子能科学技术》 EI CAS CSCD 北大核心 2013年第5期866-870,共5页
α能谱法是环境中222 Rn/220 Rn气体活度浓度测量的重要方法之一。吸收层及探测器能窗等导致的α能谱低能拖尾是影响222 Rn/220 Rn活度浓度准确测量的重要因素。为修正α能谱法对222 Rn/220 Rn气体活度浓度的测量结果,本文从原理上探讨... α能谱法是环境中222 Rn/220 Rn气体活度浓度测量的重要方法之一。吸收层及探测器能窗等导致的α能谱低能拖尾是影响222 Rn/220 Rn活度浓度准确测量的重要因素。为修正α能谱法对222 Rn/220 Rn气体活度浓度的测量结果,本文从原理上探讨了拖尾形成的原因及其对222 Rn/220 Rn气体活度浓度测量的影响。结合商用测氡仪,实验修正了222 Rn/220 Rn气体活度浓度的测量结果,对修正前后的结果进行了实验比对。研究表明,经准确刻度后的修正因子和刻度因子能很好地用于修正222 Rn/220 Rn气体活度浓度的测量结果,保证了测量结果的准确性。建议在对α能谱法测量222 Rn/220 Rn气体活度浓度的仪器进行刻度检定时,必要情况下需对拖尾修正因子和刻度因子进行适当刻度。 展开更多
关键词 222Rn 220Rn 测氡仪 α能谱法 拖尾修正因子 刻度因子
在线阅读 下载PDF
新型连续测氡仪研制 被引量:7
16
作者 李志强 肖德涛 +5 位作者 赵桂芝 单健 吴喜军 陈颖 肖高平 李越 《核电子学与探测技术》 CAS 北大核心 2015年第12期1246-1250,共5页
为实现快速可靠连续测氡需要,基于静电收集法研制了一种新型连续测氡仪。该测量仪采用PIPS探测器对^(218)Po产生的α粒子能量进行甑别,采用阈值自动调节方法消除温度对半导休探测器能谱峰的影响,采用温湿度自动补偿修正方法消除湿度对... 为实现快速可靠连续测氡需要,基于静电收集法研制了一种新型连续测氡仪。该测量仪采用PIPS探测器对^(218)Po产生的α粒子能量进行甑别,采用阈值自动调节方法消除温度对半导休探测器能谱峰的影响,采用温湿度自动补偿修正方法消除湿度对探测效率的影响,采用大流量取样和迭代修正方法实现可靠快速测量。测试结果表明:新型连续测氡仪10个连续测量周期的测量结果相对平均偏差在5%以内,能够快速响应氡浓度的变化,适应0~45℃环境温度的需要,经-20℃低温储存实验后该测氡仪能正常工作。 展开更多
关键词 静电收集 α能谱法 测氡仪
在线阅读 下载PDF
氡测量仪检定/校准装置的研制 被引量:6
17
作者 唐方东 何林锋 +1 位作者 张雄杰 汤彬 《中国测试》 CAS 2010年第1期57-60,共4页
为建立氡测量的计量标准,研制以多功能的标准氡室为核心的氡测量仪检定/校准装置。采用氡浓度动态稳定技术以实现氡浓度的自动调控;设计用夹胶钢化玻璃制作氡室以减少箱体对氡的吸附,并具有良好的保温效果;设计制作温湿度调控系统和气... 为建立氡测量的计量标准,研制以多功能的标准氡室为核心的氡测量仪检定/校准装置。采用氡浓度动态稳定技术以实现氡浓度的自动调控;设计用夹胶钢化玻璃制作氡室以减少箱体对氡的吸附,并具有良好的保温效果;设计制作温湿度调控系统和气溶胶发生与采集装置,实现氡子体放射性气溶胶的检测功能。装置氡室体积为4m3,氡浓度测量范围为370~20000Bq/m3,氡浓度值测量结果的相对扩展不确定度不超过5.8%,可用于测氡仪器的检定校准和氡子体放射性气溶胶的实验研究。 展开更多
关键词 放射性计量学 检定/校准装置 氡浓度动态稳定 标准氡室 氡测量仪
在线阅读 下载PDF
测氡仪的检定/校准与结果分析 被引量:6
18
作者 徐一鹤 何林锋 唐方东 《核电子学与探测技术》 CAS CSCD 北大核心 2011年第3期324-326,共3页
测氡仪是最常用的空气中氡浓度测量手段,仪器的响应会因环境等因素而发生变化。上海市计量测试技术研究院的氡测量仪检定装置2008至2009年对测氡仪检定/校准的结果显示,约三分之一的测氡仪其相对固有误差超过±10%,校准因子的年变... 测氡仪是最常用的空气中氡浓度测量手段,仪器的响应会因环境等因素而发生变化。上海市计量测试技术研究院的氡测量仪检定装置2008至2009年对测氡仪检定/校准的结果显示,约三分之一的测氡仪其相对固有误差超过±10%,校准因子的年变化超过5%,表明测氡仪定期的检定/校准是保障测氡仪器氡浓度测量结果准确可靠的必要前提。 展开更多
关键词 测氡仪 氡浓度 检定/校准 校准因子
在线阅读 下载PDF
AlphaGUARD P2000便携测氡仪在地震观测中的应用与实验研究 被引量:5
19
作者 姜薇薇 马城城 +2 位作者 王玲玲 汪世仙 刘川琴 《地震工程学报》 CSCD 北大核心 2015年第3期901-905,共5页
目前用于地下水中氡浓度观测的仪器,特别是模拟氡观测仪器的更新换代相当缓慢,且普遍采用的FD-105K型静电计和FD-125型氡钍分析器均采用人工鼓泡、读数,存在一定的人为误差。经实验研究认为AlphaGUARD P2000便携测氡仪完全采用自动鼓泡... 目前用于地下水中氡浓度观测的仪器,特别是模拟氡观测仪器的更新换代相当缓慢,且普遍采用的FD-105K型静电计和FD-125型氡钍分析器均采用人工鼓泡、读数,存在一定的人为误差。经实验研究认为AlphaGUARD P2000便携测氡仪完全采用自动鼓泡和读数,可避免人工操作带来的误差,提高水氡观测质量,利于捕捉地震异常信息。同时,AlphaGUARAD P2000便携测氡仪携带方便、自带电源、操作简单,可用于野外观测、异常核实和土壤氡的测量,拓展地震地下流体中氡的观测范围。 展开更多
关键词 实验 测氡仪
在线阅读 下载PDF
中国高本底城市的土壤氡水平及分布 被引量:6
20
作者 王南萍 肖磊 李灿苹 《物探与化探》 CAS CSCD 2012年第4期646-650,共5页
在广东珠海地区采用便携式半导体测氡仪进行了大比例尺土壤氡浓度调查,测点数469个,面积大于100km2。珠海地区地下0.6 m处的平均土壤氡浓度为55.94±58.54 kBq/m3,其中在珠海斗门的第四纪沉积物地区、沉积物和风化花岗岩混合地区,... 在广东珠海地区采用便携式半导体测氡仪进行了大比例尺土壤氡浓度调查,测点数469个,面积大于100km2。珠海地区地下0.6 m处的平均土壤氡浓度为55.94±58.54 kBq/m3,其中在珠海斗门的第四纪沉积物地区、沉积物和风化花岗岩混合地区,以及风化花岗岩地区的土壤氡浓度分别是7.14±8.75,37.64±25.92和151.25±196.23 kBq/m3。高氡潜势区主要分布在黑云母花岗岩、风化花岗岩地区和新的工业开发区,且表现出与当地岩性密切相关。城市化和工业化改变了原有的天然辐射背景。珠海市区的平均土壤氡浓度分别为广州、泉州和晋江市平均值的8.3倍和15倍。研究结果表明:珠海是一个氡潜势较高的区域,需要进一步开展辐射防护目的的氡测量。 展开更多
关键词 土壤气 半导体测氡仪 高本底 珠海
在线阅读 下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部