Objective: To determine whether Oxiplex/AP Gel (FzioMed, San Luis Obispo, CA) was safe and preliminarily effective in reducing postsurgical adhesions after adnexal surgery by laparoscopy. Design: Prospective, multicen...Objective: To determine whether Oxiplex/AP Gel (FzioMed, San Luis Obispo, CA) was safe and preliminarily effective in reducing postsurgical adhesions after adnexal surgery by laparoscopy. Design: Prospective, multicenter, double-blind, randomized, U.S. Food and Drug Administration-monitored feasibility study. Setting: University and private clinics. Patient (s): Patients undergoing laparoscopic surgery with pelvic adhesions, tubal occlusion, endometriosis, and/or dermoids were randomized to receive Oxiplex/AP Gel or no further treatment after surgery. Intervention(s): A blinded, parallelgroup design was conducted at six centers. Patients (aged 18-46 years) underwent laparoscopic surgery, with secondlook surgery 6-10 weeks later. Surgeries were videotaped. Oxiplex/AP Gel was used to cover adnexa and adjacent tissue. Main Outcome Measure(s): Blinded reviews of videotapes were quantitated with the American Fertility Society adhesion score (AFS score). Result(s): In 18 treatment patients, surgery was performed on 29 adnexa. Application of Oxiplex/AP Gel required approximately 90 seconds. In 10 control patients, surgery was performed on 18 adnexa. The mean baseline AFS score for each group was 8.0. At second look, treated adnexa had the same score (8.1), whereas in control adnexa the score increased (from 8.0 to 11.6). Thirty-four percent of treated adnexa increased in adhesion score, in contrast to 67%of control adnexa. There were no device-related adverse events. Conclusion(s): In this pilot study, Oxiplex/AP Gel was safe, easy to use with laparoscopy, and produced a reduction in the increase of adnexal adhesion scores.展开更多
基于RSSI(Received Signal Strength Indication)位置指纹的Wi-Fi室内定位现已被大量应用于各类基于位置信息的服务中。但指纹定位的精度受到RSSI信号的剧烈波动影响,难以满足高精度位置信息服务的需求。为克服该困难,提出一种结合虚拟A...基于RSSI(Received Signal Strength Indication)位置指纹的Wi-Fi室内定位现已被大量应用于各类基于位置信息的服务中。但指纹定位的精度受到RSSI信号的剧烈波动影响,难以满足高精度位置信息服务的需求。为克服该困难,提出一种结合虚拟AP技术与高精度CNN(Convolutional Neural Network)判别模型的定位方法。该方法通过距离比定位得到虚拟AP的位置,并将该信息与RSSI融合作为数据增强CNN模型的输入,确定样本的位置。设计实验方案采集实际的用户终端RSSI数据,构建指纹定位的数据集,验证所提出的指纹定位方案的有效性。实验结果表明,在该数据集上,所提出的方法在确定区域时的准确度达到91%,并将95%的定位误差控制在2 m以内。对比现有的定位方案,所提出的方案在定位精度上有显著提升。展开更多
针对金刚石滚轮是一种回转体零件以及其加工制造过程中信息化集成程度低等特点,对金刚石滚轮的特征信息提取、特征加工方案决策、数控程序后置处理等关键技术进行了研究,采用了产品模型数据交换标准STEP AP 242,实现对金刚石滚轮的制造...针对金刚石滚轮是一种回转体零件以及其加工制造过程中信息化集成程度低等特点,对金刚石滚轮的特征信息提取、特征加工方案决策、数控程序后置处理等关键技术进行了研究,采用了产品模型数据交换标准STEP AP 242,实现对金刚石滚轮的制造特征信息提取,使用STEP AP 242和PDM相结合的集成方式,将金刚石滚轮三维模型作为制造加工信息的载体,并选择SolidWorks作为CAD和CAM软件,以及选择Aras Innovator作为PDM平台,使用C#编程语言和数据库技术开发了金刚石滚轮CAD/CAPP/CAM/PDM集成系统,并进行了实例验证。展开更多
文摘Objective: To determine whether Oxiplex/AP Gel (FzioMed, San Luis Obispo, CA) was safe and preliminarily effective in reducing postsurgical adhesions after adnexal surgery by laparoscopy. Design: Prospective, multicenter, double-blind, randomized, U.S. Food and Drug Administration-monitored feasibility study. Setting: University and private clinics. Patient (s): Patients undergoing laparoscopic surgery with pelvic adhesions, tubal occlusion, endometriosis, and/or dermoids were randomized to receive Oxiplex/AP Gel or no further treatment after surgery. Intervention(s): A blinded, parallelgroup design was conducted at six centers. Patients (aged 18-46 years) underwent laparoscopic surgery, with secondlook surgery 6-10 weeks later. Surgeries were videotaped. Oxiplex/AP Gel was used to cover adnexa and adjacent tissue. Main Outcome Measure(s): Blinded reviews of videotapes were quantitated with the American Fertility Society adhesion score (AFS score). Result(s): In 18 treatment patients, surgery was performed on 29 adnexa. Application of Oxiplex/AP Gel required approximately 90 seconds. In 10 control patients, surgery was performed on 18 adnexa. The mean baseline AFS score for each group was 8.0. At second look, treated adnexa had the same score (8.1), whereas in control adnexa the score increased (from 8.0 to 11.6). Thirty-four percent of treated adnexa increased in adhesion score, in contrast to 67%of control adnexa. There were no device-related adverse events. Conclusion(s): In this pilot study, Oxiplex/AP Gel was safe, easy to use with laparoscopy, and produced a reduction in the increase of adnexal adhesion scores.
文摘针对金刚石滚轮是一种回转体零件以及其加工制造过程中信息化集成程度低等特点,对金刚石滚轮的特征信息提取、特征加工方案决策、数控程序后置处理等关键技术进行了研究,采用了产品模型数据交换标准STEP AP 242,实现对金刚石滚轮的制造特征信息提取,使用STEP AP 242和PDM相结合的集成方式,将金刚石滚轮三维模型作为制造加工信息的载体,并选择SolidWorks作为CAD和CAM软件,以及选择Aras Innovator作为PDM平台,使用C#编程语言和数据库技术开发了金刚石滚轮CAD/CAPP/CAM/PDM集成系统,并进行了实例验证。