Study on the instantaneous protection reliability of low voltage circuit breakers 被引量:8
1
作者 LU Jian-guo DU Tai-hang LUO Yan-yan 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期370-377,共8页
This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage cir... This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented. 展开更多
关键词 Low voltage circuit breakers Instantaneous protection reliability Non-periodic component of current Phase selective closing
在线阅读 下载PDF
Power supply arm protection scheme of high-speed railway based on wide-area current differential
2
作者 Guosong Lin Bin Hong +1 位作者 Zefang Wu Xuguo Fu 《Railway Engineering Science》 2023年第3期281-292,共12页
When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads t... When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved. 展开更多
关键词 Cross-coupling AT power supply Wide-area current differential Power supply arm protection Equivalent circuit High-Speed railway
在线阅读 下载PDF
Influence of DFIG Wind Turbine Protection and Control during Voltage Dip on Circuit Breaker Operation
3
作者 Anssi Salomo Makinen Ontrei Raipala Sami Repo Heikki Tuusa 《Journal of Energy and Power Engineering》 2013年第1期126-138,共13页
This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossing... This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossings of the fault current occur. This is an important subject because the ftmdamental property of the CB (circuit breaker) is that it breaks the current when the current is very near zero. The study was conducted using a hardware-in-the-loop test environment constructed using two real time simulators (dSPACE and RTDS) and a commercial protection relay. It is found that the reactive current injection during a voltage dip demanded by the grid codes enhances the operation of the WT protection because the zero crossings of the currents through CB are attained earlier. In addition, the size of the crowbar resistance has a significant influence on the zero crossings. 展开更多
关键词 DFIG reactive current circuit breaker loss of mains relay protection.
在线阅读 下载PDF
A Novel Crowbar Impulse Current Circuit for Testing the Switch-Type SPD 被引量:1
4
作者 姚学玲 陈景亮 孙伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期221-226,共6页
A crowbar impulse current circuit for testing the switch-type surge protective device (SPD) is presented. The crowbar circuit consists of a computer control circuit, a trigger voltage pulse generator, a main dischar... A crowbar impulse current circuit for testing the switch-type surge protective device (SPD) is presented. The crowbar circuit consists of a computer control circuit, a trigger voltage pulse generator, a main discharging switch, and a crowbar pseudospark switch. The active trigger technology was studied in the crowbar impulse current circuit. The circuit monitors the main discharging current and generates a trigger signal at a proper time for the crowbar pseudospark switch operation. The trigger characteristics of the main discharge switch and the crowbar pseu- dospark switch were investigated. By monitoring the preset applied capacitor voltage, the gap distance of the main discharging switch could be adjusted to ensure a discharging delay time less than 2 μs. Equipped with a surface ttashover trigger device made of high relative perimittivity dielectric material BaTiO3 (εr = 3460), the discharge delay time of the crowbar pseudospark switch is less than 85 ns, and the minimum operating voltage is less than 1% of its self-breakdown voltage. With a storage capacitor of 9 μF , an inductor of 18 μH and a crowbar pseudospark switch, a load of 30 mΩ and an applied capacitor voltage of 40 kV, an impulse current waveform of maximum 25 kA was generated with a rise time and time to half peak value of 17.2 μs and 336μs respectively. 展开更多
关键词 crowbar impulse current circuit triggered crowbar pseudospark switch activetrigger technology switch-type surge protective device
在线阅读 下载PDF
Protection of Low Voltage CIGRE Distribution Network 被引量:1
5
作者 Ghullam Mustafa Bhutto Birgitte Bak-Jensen +1 位作者 Claus Leth Bak Jayakrishnan R. Pillai 《Smart Grid and Renewable Energy》 2013年第9期489-500,共12页
High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is the protection of the system which needs to be fast, reliable and cos... High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is the protection of the system which needs to be fast, reliable and cost effective. The study about the protection of the Low Voltage (LV) CIGRE distribution grid and networks like this has been proposed in this paper. The main objective of this paper is to develop protection against short circuit faults which might appear anywhere in the network. The protection of the power networks that comprises of renewable energy generation units is complicated because of the bidirectional flow of the current and is a challenge for the protection engineers. The selection of the protection devices in this paper is made to protect the network against faults in grid connected and island mode of operation. Ultra-fast fuses are proposed in order to protect the inverters used for Photovoltaic (PV) and battery applications. The disconnection of the PV solar panels when in island mode is made by proposing switch disconnecting devices. ABB is currently using these kinds of disconnection devices for the purpose of protecting solar panels against over voltages in the case of islanding. The over speed protection of the existing Wind Turbine Generator (WTG) in the CIGRE network in case of grid loss is also proposed in this paper. 展开更多
关键词 current BASED protection VOLTAGE BASED protection Over Speed protection Fuse Under VOLTAGE Relay circuit BREAKER Switch DISCONNECTOR
暂未订购
Short-circuit Current Characteristics of Wind Generators
6
作者 Seung-Jae LEE Myeon-Song CHOI 《电力系统自动化》 EI CSCD 北大核心 2012年第8期110-114,共5页
To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreemen... To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreement has not been reached so far.The SCC characteristics for different wind generators are studied.PSCAD simulation is performed in the same system integrated with different kinds of wind generators,and their results are compared with those reported in IEEE papers.The detection possibility by overcurrent relay(OCR)is discussed based on the simulation results. 展开更多
关键词 风力发电机组 短路电流 电流特性 配电系统 PSCAD 过流继电器 IEEE 通过检测
在线阅读 下载PDF
Advancement in Wide Area Monitoring Protection and Control Using PMU’s Model in MATLAB/SIMULINK
7
作者 Waheed Ur Rahman Muhammad Ali +7 位作者 Amjad Ullah Hafeez Ur Rahman Majid Iqbal Haseeb Ahmad Adnan Zeb Zeeshan Ali M. Ahsan Shahzad Beenish Taj 《Smart Grid and Renewable Energy》 2012年第4期294-307,共14页
A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power system... A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station. 展开更多
关键词 WIDE Area MONITORING protection and CONTROL (WAMPAC) Phasor Measurement uNit (PMU) WIDE Area MONITORING (WAM) Global Positioning System (GPS) WIDE Area CONTROLLER (WAC) Local Area CONTROLLER (LAC) Phase Angle MONITORING (PAM) Automatic Generation CONTROL (AGC) circuit Breaker (CB) current TRANSFORMERS (CTs) Potential TRANSFORMERS (PTs)
暂未订购
Research on IGBT Drive Circuit Based on 2QD30A17K-I Driver
8
作者 HE Wei-wei WANG Zhi-han FU Jun-yin LI Yan-fei 《电力电子技术》 CSCD 北大核心 2012年第12期60-61,66,共3页
The insulated gate bipolar transistor(IGBT) has become the most popular controllable power switching device in the design of power electronics industry.As the interface of power circuit and control circuit in power so... The insulated gate bipolar transistor(IGBT) has become the most popular controllable power switching device in the design of power electronics industry.As the interface of power circuit and control circuit in power source, the IGBT drive circuit should be with short transition time and the function of isolating safely and monitoring correctly the short-circuit and over-voltage fault.This paper presents the short-circuit protection theory and relative parameter selecting rules,based on the research on 2QD30A17K-I,the representative of high voltage and high power driver. 展开更多
关键词 IGBTs 电力电子技术 MOSFET 晶体管
在线阅读 下载PDF
Solutions to Consider in Current Transformer Selection for APR1400 Nuclear Power Plant Medium Voltage Switchgears
9
作者 Dumam Roman Jackson Choong-Koo Chang 《Journal of Energy and Power Engineering》 2017年第10期670-678,共9页
This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medi... This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research. 展开更多
关键词 CT CT saturation accuracy class metering CT protection CT MV switchgear short circuit fault current knee voltage.
在线阅读 下载PDF
电磁式漏电断路器保护特性分析与稳健性设计
10
作者 李奎 于明浩 +2 位作者 牛峰 武一 卢志伟 《电工技术学报》 北大核心 2025年第22期7375-7386,共12页
电磁式漏电断路器无需辅助电源,在线路发生断相等故障后仍能进行漏电保护,广泛应用于漏电保护要求较高的场合。该文针对电磁式漏电断路器的漏电保护驱动电路与漏电保护特性稳健性开展研究。首先,分析电磁式漏电断路器的工作原理,研究串... 电磁式漏电断路器无需辅助电源,在线路发生断相等故障后仍能进行漏电保护,广泛应用于漏电保护要求较高的场合。该文针对电磁式漏电断路器的漏电保护驱动电路与漏电保护特性稳健性开展研究。首先,分析电磁式漏电断路器的工作原理,研究串-并联电容补偿漏电驱动电路的拓扑结构与工作原理;其次,针对串-并联电容补偿漏电驱动电路,确定补偿电容匹配关系及其与漏电动作值的关系,分析剩余电流互感器磁滞特性与饱和特性对补偿电容匹配关系的影响;最后,研究补偿电容分散性和铁心磁参数分散性对漏电保护特性的影响,并对剩余电流互感器及补偿电容进行优化设计,提升了电磁式漏电断路器漏电保护特性的稳健性。 展开更多
关键词 电磁式漏电断路器 漏电保护特性 电路拓扑分析 剩余电流互感器 稳健性设计
在线阅读 下载PDF
辉光放电质谱仪真空泵碳化硅逆变器设计
11
作者 王占扩 李想 陈吉文 《自动化技术与应用》 2025年第9期100-104,共5页
针对辉光放电质谱仪真空机械泵电机逆变器工作周期较长,可靠性和稳定性要求高的特点,设计一套三相全SiC MOSFET的逆变器。首先介绍控制电路和功率电路的设计思路,然后详细介绍驱动和保护电路工作原理,并对直通短路保护电路进行优化设计... 针对辉光放电质谱仪真空机械泵电机逆变器工作周期较长,可靠性和稳定性要求高的特点,设计一套三相全SiC MOSFET的逆变器。首先介绍控制电路和功率电路的设计思路,然后详细介绍驱动和保护电路工作原理,并对直通短路保护电路进行优化设计,使用复杂可编程逻辑控制器(complex programmable logic controller,CPLD)代替各种逻辑芯片,降低电路复杂度,最后经过实验验证,逆变器运行良好,可以在2.4μs完成过流保护、在0.4μs完成半桥直通短路保护,可靠性高,为SiC MOSFET变流器设计应用提供一定的参考价值。 展开更多
关键词 碳化硅MOSFET 逆变器 过流保护 直通短路保护
在线阅读 下载PDF
一种具有不可恢复的过流保护电路设计
12
作者 唐俊 徐立浩 +2 位作者 王喆 张心静 李晨洋 《集成电路与嵌入式系统》 2025年第10期61-65,共5页
为满足工业设备过流保护需求,提出一种基于模块化设计的电子电路解决方案,旨在实现精准电流检测与快速保护响应。采用模块化设计架构,集成电流感应放大器、迟滞比较器和继电器协同工作。通过电流感应放大器实现0.1 mA级精度信号采集,利... 为满足工业设备过流保护需求,提出一种基于模块化设计的电子电路解决方案,旨在实现精准电流检测与快速保护响应。采用模块化设计架构,集成电流感应放大器、迟滞比较器和继电器协同工作。通过电流感应放大器实现0.1 mA级精度信号采集,利用迟滞比较器设置保护阈值,配合固态继电器执行电路通/断控制。实验结果表明:当电流超过设定阈值时,电路在10 ms内完成切断动作,且在阈值电流下降到阈值电流以下仍保持断路状态,避免误恢复。经多次循环测试验证,保护动作准确率达98.4%,有效杜绝了因多次过流对设备造成的潜在损害,为高精度电流保护提供创新方案。 展开更多
关键词 过流保护 模块化设计 电流感应放大器 切断电流通路 保持短路状态
在线阅读 下载PDF
基于拖尾电流识别的断路器失灵保护判据与延时优化 被引量:1
13
作者 陈祥文 刘阳 +5 位作者 赵青春 张今 金明亮 徐晓春 王玉龙 谢华 《中国电力》 北大核心 2025年第6期198-205,共8页
当断路器动作后,互感器一次侧电流突然减小,电感效应会使其二次侧形成拖尾电流,导致失灵保护返回时间过长,造成失灵保护误动。提出一种基于拖尾电流识别的断路器失灵保护综合判据,改善识别可靠性。首先,分析互感器工作原理,探究断路器... 当断路器动作后,互感器一次侧电流突然减小,电感效应会使其二次侧形成拖尾电流,导致失灵保护返回时间过长,造成失灵保护误动。提出一种基于拖尾电流识别的断路器失灵保护综合判据,改善识别可靠性。首先,分析互感器工作原理,探究断路器失灵保护受拖尾电流的影响机理;其次,将基于最小二乘法三点窗算法与Fréchet距离算法结合,构建一种拖尾电流的快速可靠识别综合判据;最后,根据断路器失灵保护动作时延构成和要求,对断路器失灵保护延时进行优化,所提方法能够有效避免断路器失灵保护的误动。 展开更多
关键词 断路器 失灵保护 拖尾电流 延时优化
在线阅读 下载PDF
宽量程精密电流检测电路的设计 被引量:1
14
作者 肖亮 俞洋 +2 位作者 黄成 崔渊 王云松 《山东工业技术》 2025年第1期17-24,共8页
为满足半导体功率器件测量对高精度、宽量程的需求,本系统设计了一种覆盖1 nA至10 mA量程的电流检测电路,分辨率最低达10 fA。系统包括漏电流保护、I/V转换、信号调理和A/D转换等模块,通过STM32控制器实现数据处理与校准。实验结果表明... 为满足半导体功率器件测量对高精度、宽量程的需求,本系统设计了一种覆盖1 nA至10 mA量程的电流检测电路,分辨率最低达10 fA。系统包括漏电流保护、I/V转换、信号调理和A/D转换等模块,通过STM32控制器实现数据处理与校准。实验结果表明,本系统测量精度在10 fA至1μA范围内小于0.1%,1μA至100μA范围内小于0.05%,100μA至10 mA范围内小于0.03%。 展开更多
关键词 高精度 微弱电流 保护电路 宽量程
在线阅读 下载PDF
面向新能源电力系统的交流输电线保护新方案 被引量:3
15
作者 刘琦 褚旭 +2 位作者 付乐天 余绍帅 王威东 《智慧电力》 北大核心 2025年第7期76-83,共8页
针对新能源电力系统中传统交流保护适应性下降问题,提出一种新型交流输电线保护方案。首先,基于新能源接入电网的典型事故案例,深入分析了工程实际中传统交流保护存在的不足;其次,通过推导短路电流与序阻抗角解析表达式,揭示了逆变型电... 针对新能源电力系统中传统交流保护适应性下降问题,提出一种新型交流输电线保护方案。首先,基于新能源接入电网的典型事故案例,深入分析了工程实际中传统交流保护存在的不足;其次,通过推导短路电流与序阻抗角解析表达式,揭示了逆变型电源暂态电流及序分量的时空演化规律;最终,结合工程需求提出2种改进保护方法,有效解决传统保护的适应性问题。仿真结果表明,该方案无需增加硬件投资,即可显著提升新能源电源接入场景下交流保护的适应性。 展开更多
关键词 新能源电力系统 逆变电源 典型事故案例 短路电流 改进保护
在线阅读 下载PDF
风电占比提高对电网接地距离保护Ⅱ段整定全局影响分析
16
作者 谢钰 武志刚 《电力系统及其自动化学报》 北大核心 2025年第2期20-28,共9页
从风电与电网间关系的角度研究风电占比提高短路电流分布变化对传统电力系统运行规则的影响。以接地距离保护Ⅱ段整定为例,首先结合风机的限流特性与继保整定规则分析风电占比提高对线路整定配合的影响;其次定义反映线路失配风险的指标... 从风电与电网间关系的角度研究风电占比提高短路电流分布变化对传统电力系统运行规则的影响。以接地距离保护Ⅱ段整定为例,首先结合风机的限流特性与继保整定规则分析风电占比提高对线路整定配合的影响;其次定义反映线路失配风险的指标——失配系数,并通过失配系数分析线路失配的影响因素;最后计算广东电网中线路的失配系数,并对受影响区域与网架、风电并网情况的关系进行分析。通过研究风电占比提高对实际电网整定的全局影响,从完善电源出力组合的角度提出了线路易失配时的解决方法。 展开更多
关键词 短路电流 继电保护 接地距离保护Ⅱ段 风电 失配系数
在线阅读 下载PDF
低压框架式断路器智能脱扣器校验装置的设计与实现 被引量:1
17
作者 李枝玖 陈泓旭 +2 位作者 吕昆烨 张一新 杨海松 《红水河》 2025年第3期136-140,共5页
针对低压框架式断路器传统电流校验方式易损坏智能脱扣器二次回路的问题,笔者设计一种基于DSP高频PWM控制的电压型脱扣器校验装置。该装置通过输出电压信号替代传统大电流信号,可用于H-DW18系列框架式断路器的STJ18型智能脱扣器校验。... 针对低压框架式断路器传统电流校验方式易损坏智能脱扣器二次回路的问题,笔者设计一种基于DSP高频PWM控制的电压型脱扣器校验装置。该装置通过输出电压信号替代传统大电流信号,可用于H-DW18系列框架式断路器的STJ18型智能脱扣器校验。该装置采用高频逆变与闭环控制策略,实现了保护四性(选择性、速动性、灵敏性、可靠性)的精准校验,具备过载长延时、短路短延时等8项试验功能。实验表明:在H-DW18系列断路器测试中,输出电压精度达0.2 mV,时间精度达1 ms,且完整保留电子脱扣器动作特征。研究成果可为智能断路器状态监测提供新型技术手段,对提升电力设备智能运维水平具有重要工程应用价值。 展开更多
关键词 智能脱扣器校验 电压型校验装置 DSP高频PWM控制 低压框架式断路器 三段式电流保护
在线阅读 下载PDF
面向低电压穿越工况的DFIG变流器IGBT结温管理 被引量:1
18
作者 杨晨 乐应波 +3 位作者 杨程 李伟邦 何鑫 崔昊杨 《半导体技术》 北大核心 2025年第5期523-531,共9页
低电压穿越(LVRT)期间,电压骤降会导致双馈风电机组(DFIG)电流严重畸变,变流器中IGBT模块的瞬时功耗急剧上升,器件过温失效风险剧增。通过仿真实验分析了LVRT工况下变流器的温升特性,提出了一种结合硬件保护电路与开关频率调节的结温治... 低电压穿越(LVRT)期间,电压骤降会导致双馈风电机组(DFIG)电流严重畸变,变流器中IGBT模块的瞬时功耗急剧上升,器件过温失效风险剧增。通过仿真实验分析了LVRT工况下变流器的温升特性,提出了一种结合硬件保护电路与开关频率调节的结温治理方法。引入投资回报比(ROI)作为开关频率选取依据,平衡温升与电流总谐波失真(THD)增长率。采用量子粒子群优化(QPSO)算法确定最优开关频率,并与卸荷撬棍电路协同,有效抑制了温升。仿真结果表明,网侧电压跌至0.3 p.u.时,所提策略使IGBT故障瞬间温升波幅降低37%,穿越期间温升波幅降低58%,有效抑制了LVRT工况下的温升现象。 展开更多
关键词 IGBT模块 低电压穿越(LVRT) 热管理策略 电流谐波 开关频率 硬件保护电路
原文传递
基于碳化硅MOSFET半桥驱动及保护电路设计 被引量:1
19
作者 郑高铭 孙峰 +3 位作者 李欢 胡雅婷 刘京 刘羽捷 《电子技术应用》 2025年第3期90-97,共8页
针对碳化硅MOSFET驱动电路设计难度较大、门极易受串扰、保护功能不齐全以及全国产化的问题,基于国产芯片设计了一款碳化硅MOSFET半桥驱动及保护电路。重点分析总结了碳化硅MOSFET有源米勒钳位保护、退饱和保护以及桥臂互锁保护原理与... 针对碳化硅MOSFET驱动电路设计难度较大、门极易受串扰、保护功能不齐全以及全国产化的问题,基于国产芯片设计了一款碳化硅MOSFET半桥驱动及保护电路。重点分析总结了碳化硅MOSFET有源米勒钳位保护、退饱和保护以及桥臂互锁保护原理与模型。在隔离原边信号与副边信号的同时,采用18 V/-3.3 V的高低电平,实现对上、下桥臂碳化硅MOSFET的控制,同时集成了欠压锁定、退饱和保护、桥臂互锁、有源米勒钳位保护的功能。与国际先进水平Wolf Speed的碳化硅MOSFET驱动板CGD1200HB2P-BM2进行了参数对比和功能测试。实验结果表明,该电路开关参数与CGD1200HB2P-BM2驱动板相近,满足碳化硅MOSFET驱动需求,并能可靠触发保护功能。电路已实际应用于碳化硅MOSFET的驱动中。 展开更多
关键词 碳化硅MOSFET 驱动电路 有源米勒钳位 退饱和保护
在线阅读 下载PDF
计及储能充放电特性的交流耦合光储电站送出线路纵联保护
20
作者 刘素梅 王丹枫 +2 位作者 韩伟 李伟 沈佳琪 《电力系统保护与控制》 北大核心 2025年第10期66-77,共12页
因储能在充放电模式下潮流流向截然不同,所以与同步发电机甚至光伏电站相比,光储电站的故障特性存在显著差异,传统电流差动保护面临更高的拒动风险。为此,以含有“共享储能”的交流耦合光储电站为对象,首先着重分析推导了储能电站在充... 因储能在充放电模式下潮流流向截然不同,所以与同步发电机甚至光伏电站相比,光储电站的故障特性存在显著差异,传统电流差动保护面临更高的拒动风险。为此,以含有“共享储能”的交流耦合光储电站为对象,首先着重分析推导了储能电站在充放电模式下的短路电流相角变化特性及其计算表达式。进一步分析了交流耦合光储电站的短路电流变化规律,从而揭示了光储电站分别作为电源和负荷运行时,传统电流差动保护不正确动作的成因。针对所存在的问题,提出了自适应调整等值阻抗幅值比的纵联保护新原理。利用线路两侧等值阻抗比,识别区内外故障及正常运行工况。同时通过引入等值阻抗调整系数,放大区内故障下线路两侧等值阻抗之间的差异,以实现即使高比例光储电站接入线上发生高阻故障,所提保护仍能够正确可靠动作。最终,基于PSCAD/EMTDC搭建了含交流耦合光储电站电网的电磁暂态模型,验证了所提保护的动作特性。 展开更多
关键词 短路电流特性 纵联保护新原理 阻抗幅值比 储能电站 交流耦合光储电站 送出线路
在线阅读 下载PDF