With the depletion of fossil fuels and increasing environmental concerns,the development of renewable energy,such as wave energy,has become a critical component of global energy strategies.However,challenges persist i...With the depletion of fossil fuels and increasing environmental concerns,the development of renewable energy,such as wave energy,has become a critical component of global energy strategies.However,challenges persist in the field testing methodologies for wave energy converters(WECs).In this paper,a numerical wave field of the Dawanshan Island Sea Area in Zhuhai City is constructed based on the MIKE21 SW wave model and by using an NCEP wind field driving model.In conjunction with the IEC-62600-100 standard,by taking site testing of the“Wanshan”wave energy converter on which a sea trial has been conducted in Dawanshan Island of Zhuhai city as an example,research on-site testing method for a wave energy converter has been carried out.The wave measurement position for the“Wanshan”converter was determined by combining statistically analyzed field data with a validated numerical wave model.By comparing a valid wave height at the position where a wave rider is located with a valid wave height at the position where the“Wanshan”wave energy converter is situated,the correlation coefficient between simulation and observed data reached 0.90,with a root-mean-square error of 0.19.The representativeness of wave measurement data during site testing is verified and can be used as a basis for calculating the input energy of the“Wanshan”wave energy converter.展开更多
Sensitivity analysis of thermal equilibrium parameters in the reservoir module of MIKE 11 model was conducted for the Wuxikou Reservoir in Jiangxi Province of China in order to apply the module to the environmental im...Sensitivity analysis of thermal equilibrium parameters in the reservoir module of MIKE 11 model was conducted for the Wuxikou Reservoir in Jiangxi Province of China in order to apply the module to the environmental impact assessment to accurately predict water temperature of reservoirs.Results showed that radiation parameter A and evaporation-first parameter were much more sensitive than other parameters.The values of the radiation parameter A ranged from 0.10 to 0.34.The values of evaporation-first parameter varied from 0 to 10.The sensitivity of solar absorption parameters was less than that of evaporation parameter,of which light attenuation values ranged from 0.5 to 0.7,and this parameter would not impact model results if it was more than 2.Constants in Beer's law ranged from 0.2 to 0.7.Radiation parameter B was not more sensitive than evaporation parameter and its reasonable range was higher than 0.48.The fitting curves showed consistent changing tendency for these parameters within the reasonable ranges.Additionally,all the thermal equilibrium parameters had much more important effects on surface water temperature than deep water temperature.Moreover,if no observed data could be obtained,the local empirical value would be used to input to the MIKE 11 model to simulate the changes in the discharged outflow-water temperature qualitatively.展开更多
基金supported by the“National Ocean Technology Center Innovation Fund”under Project No.N3220Z002,led by Ning Jia.The official website of the National Ocean Technology Center is accessible at:http://www.notcsoa.org.cn/.
文摘With the depletion of fossil fuels and increasing environmental concerns,the development of renewable energy,such as wave energy,has become a critical component of global energy strategies.However,challenges persist in the field testing methodologies for wave energy converters(WECs).In this paper,a numerical wave field of the Dawanshan Island Sea Area in Zhuhai City is constructed based on the MIKE21 SW wave model and by using an NCEP wind field driving model.In conjunction with the IEC-62600-100 standard,by taking site testing of the“Wanshan”wave energy converter on which a sea trial has been conducted in Dawanshan Island of Zhuhai city as an example,research on-site testing method for a wave energy converter has been carried out.The wave measurement position for the“Wanshan”converter was determined by combining statistically analyzed field data with a validated numerical wave model.By comparing a valid wave height at the position where a wave rider is located with a valid wave height at the position where the“Wanshan”wave energy converter is situated,the correlation coefficient between simulation and observed data reached 0.90,with a root-mean-square error of 0.19.The representativeness of wave measurement data during site testing is verified and can be used as a basis for calculating the input energy of the“Wanshan”wave energy converter.
基金Under the auspices of Research&Development Special Fund for Public Welfare Industry of Ministry of Environmental Protection(No.201309062201309003)
文摘Sensitivity analysis of thermal equilibrium parameters in the reservoir module of MIKE 11 model was conducted for the Wuxikou Reservoir in Jiangxi Province of China in order to apply the module to the environmental impact assessment to accurately predict water temperature of reservoirs.Results showed that radiation parameter A and evaporation-first parameter were much more sensitive than other parameters.The values of the radiation parameter A ranged from 0.10 to 0.34.The values of evaporation-first parameter varied from 0 to 10.The sensitivity of solar absorption parameters was less than that of evaporation parameter,of which light attenuation values ranged from 0.5 to 0.7,and this parameter would not impact model results if it was more than 2.Constants in Beer's law ranged from 0.2 to 0.7.Radiation parameter B was not more sensitive than evaporation parameter and its reasonable range was higher than 0.48.The fitting curves showed consistent changing tendency for these parameters within the reasonable ranges.Additionally,all the thermal equilibrium parameters had much more important effects on surface water temperature than deep water temperature.Moreover,if no observed data could be obtained,the local empirical value would be used to input to the MIKE 11 model to simulate the changes in the discharged outflow-water temperature qualitatively.