期刊文献+
共找到13,667篇文章
< 1 2 250 >
每页显示 20 50 100
Instantaneous desulfurization of molten steel with varied aluminum and silicon by CaO-Al_(2)O_(3) particles:In situ observation using confocal scanning laser microscopy
1
作者 Chunjie She Hejun Zhang +2 位作者 Yanhui Zhang Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2026年第2期545-554,共10页
Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfur... Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfurization were analyzed.When the total aluminum content in the steel increased from 6 to 1100 ppm,the CaS content in CaO–Al_(2)O_(3) particles increased from 2.1wt%to 84.84wt%after the reaction for 90 s.Furthermore,when the silicon content in the steel increased from 0.01wt%to 2.20wt%,the CaS content in CaO–Al_(2)O_(3) particles increased from 1.53wt%to 79.01wt%after the reaction for 90 s.This indicates that the increase in the aluminum and silicon contents of the steel promoted the desulfurization of CaO–Al_(2)O_(3) particles.A kinetic model was established to predict the CaO–Al_(2)O_(3) particles composition,and the diffusion coefficient of sulfur in CaO–Al_(2)O_(3) particles was 9.375×10^(−10)m^(2)·s^(−1) at 1600℃,which provided a new method for the calculation of diffusion coefficient. 展开更多
关键词 DESULFURIZATION high-temperature confocal scanning laser microscopy steel DESULFURIZER kinetic model ALUMINUM SILICON
在线阅读 下载PDF
Influence of Radio-Frequency Voltage on Electron Spin Resonance Spectroscopy in Scanning Tunneling Microscopy
2
作者 Jiaan Cao Lyuzhou Ye +1 位作者 Rui-Xue Xu Xiao Zheng 《Chinese Journal of Chemical Physics》 2025年第4期375-381,I0104,共8页
Over the last decade,the integra-tion of scanning tunneling mi-croscopy(STM)and electron spin resonance(ESR)spectroscopy has emerged as a powerful tool for measuring spin states of surface-adsorbed molecules.The radio... Over the last decade,the integra-tion of scanning tunneling mi-croscopy(STM)and electron spin resonance(ESR)spectroscopy has emerged as a powerful tool for measuring spin states of surface-adsorbed molecules.The radio-fre-quency voltage is a key physical quantity that influences STM-ESR spectra.However,the specific effect of radio-frequency voltage on the real-time electric current associated with STM-ESR sig-nal remains unclear.In this work,we employ the hierarchical equations of motion method to simulate the STM-ESR spectra of a single spin-1/2 surface-adsorbed molecule and track the temporal evolution of the electric current,thereby elucidating how the radio-frequency volt-age influences the features of STM-ESR spectra,the real-time electric current,and the char-acteristic frequencies conveyed by the electric current.These theoretical insights facilitate a deeper comprehension of experimental phenomena. 展开更多
关键词 electron spin resonance scanning tunneling microscopy Radio-frequency volt-age Real-time electric current
在线阅读 下载PDF
Scanning Electron Microscopy of Antennae of Aphidoletes aphidimyza (Diptera: Cecidomyiidae) 被引量:6
3
作者 张洁 杨茂发 《Zoological Research》 CAS CSCD 北大核心 2008年第1期108-112,共5页
The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the ... The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the female was 1050μm. Six types of sensillae on the antenna were observed, viz. chaetica (Ch), trichoidea (Tr), basiconica (Ba), cavity (Ca), styloid (St) and circumfila (Ci) on the antennae of A. aphidimyza. Sensillae Ch had a long external-process, with a base surrounded by membranous sockets and a length of about 67.5 μm. Sensillae Tr were distally curved and inserted into a depression, 61.0μm long. Sensillae Ba were peg-like and 4.7μm long on the antennae. Sensillae Ca were pit-like in appearance and the diameter of the pit was 1.2μm. Sensilla St was found on the second sub-segment flagellum of the male antennae. The length of the sensilla was about 21 μm and the diameter was 1.5μm. The circurnfila, which are a unique type of sensilla found only on cecidomyiid antennae, formed loops around each of the antennal sub-segments, and were attached to the surface by a series of stalks. Sensilla St was only present on male antenna. The number of Ba and Tr was almost the same in both sexes. There were more Sensilla Ca on the male antenna than on the female, while there was more Ch on the female. 展开更多
关键词 Aphidoletes aphidimyza scanning electron microscopy ANTENNA Sensillae ULTRASTRUCTURE
在线阅读 下载PDF
Local thermal conductivity of polycrystalline AlN ceramics measured by scanning thermal microscopy and complementary scanning electron microscopy techniques
4
作者 Zhang Yue-Fei Wang Li +6 位作者 R.Heiderhoff A.K.Geinzer Wei Bin Ji Yuan Han Xiao-Dong L.J.Balk Zhang Ze 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第1期374-379,共6页
The local thermal conductivity of polycrystalline aluminum nitride (A1N) ceramics is measured and imaged by using a scanning thermal microscope (SThM) and complementary scanning electron microscope (SEM) based t... The local thermal conductivity of polycrystalline aluminum nitride (A1N) ceramics is measured and imaged by using a scanning thermal microscope (SThM) and complementary scanning electron microscope (SEM) based techniques at room temperature. The quantitative thermal conductivity for the A1N sample is gained by using a SThM with a spatial resolution of sub-micrometer scale through using the 3w method. A thermal conductivity of 308 W/m-K within grains corresponding to that of high-purity single crystal A1N is obtained. The slight differences in thermal conduction between the adjacent grains are found to result from crystallographic misorientations, as demonstrated in the electron backscattered diffraction. A much lower thermal conductivity at the grain boundary is due to impurities and defects enriched in these sites, as indicated by energy dispersive X-ray spectroscopy. 展开更多
关键词 thermal conductivity A1N ceramics scanning thermal microscopy scanning electronmicroscopy
原文传递
In-situ observation of nonmetallic inclusions in steel using confocal scanning laser microscopy:A review 被引量:2
5
作者 Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2025年第5期975-991,共17页
The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are revi... The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are reviewed and summarized,particularly the col-lision of various inclusions,dissolution of inclusions in liquid slag,and reactions between inclusions and steel.Solid inclusions exhibited a high collision tendency,whereas pure liquid inclusions exhibited minimal collisions because of the small attraction force induced by their<90°contact angle with molten steel.The collision of complex inclusions in molten steel was not included in the scope of this study and should be evaluated in future studies.Higher CaO/Al_(2)O_(3)and CaO/SiO_(2)ratios in liquid slag promoted the dissolution of Al_(2)O_(3)-based in-clusions.The formation of solid phases in the slag should be prevented to improve dissolution of inclusions.To accurately simulate the dissolution of inclusions in liquid slag,in-situ observation of the dissolution of inclusions at the steel-slag interface is necessary.Using a combination of CSLM and scanning electron microscopy-energy dispersive spectroscopy,the composition and morphological evolution of the inclusions during their modification by the dissolved elements in steel were observed and analyzed.Although the in-situ observa-tion of MnS and TiN precipitations has been widely studied,the in-situ observation of the evolution of oxide inclusions in steel during so-lidification and heating processes has rarely been reported.The effects of temperature,heating and cooling rates,and inclusion character-istics on the formation of acicular ferrites(AFs)have been widely studied.At a cooling rate of 3-5 K/s,the order of AF growth rate in-duced by different inclusions,as reported in literature,is Ti-O<Ti-Ca-Zr-Al-O<Mg-O<Ti-Zr-Al-O<Mn-Ti-Al-O<Ti-Al-O<Zr-Ti-Al-O.Further comprehensive experiments are required to investigate the quantitative relationship between the formation of AFs and inclusions. 展开更多
关键词 INCLUSION STEEL in-situ observation confocal scanning laser microscopy
在线阅读 下载PDF
Scanning transmission electron microscopy: A review of high angle annular dark field and annular bright field imaging and applications in lithium-ion batteries 被引量:2
6
作者 Yu-Xin Tong Qing-Hua Zhang Lin Gu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期23-34,共12页
Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. H... Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. High angle annular dark field(HAADF) and annular bright field(ABF) imaging of the aberration-corrected STEM are widely used due to their high-resolution capabilities and easily interpretable image contrasts. However, HAADF mode of the STEM is still limited in detecting light elements due to the weak electron-scattering power. ABF mode of the STEM could detect light and heavy elements simultaneously, providing unprecedented opportunities for probing unknown structures of materials. Atomiclevel structure investigation of materials has been achieved by means of these imaging modes, which is invaluable in many fields for either improving properties of materials or developing new materials. This paper aims to provide a introduction of HAADF and ABF imaging techniques and reviews their applications in characterization of cathode materials, study of electrochemical reaction mechanisms, and exploring the effective design of lithium-ion batteries(LIBs). The future prospects of the STEM are also discussed. 展开更多
关键词 scanning transmission electron microscopy high angle annular dark field annular bright field lithium-ion batteries
原文传递
50 years of scanning electron microscopy of bone——a comprehensive overview of the important discoveries made and insights gained into bone material properties in health,disease,and taphonomy 被引量:2
7
作者 Furqan A.Shah Krisztina Ruscsák Anders Palmquist 《Bone Research》 SCIE CAS CSCD 2019年第2期123-137,共15页
Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair.The scanning electron microscope (SEM) is among the most frequently used instrument... Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair.The scanning electron microscope (SEM) is among the most frequently used instruments for examining bone.It offers the key advantage of very high spatial resolution coupled with a large depth of field and wide field of view.Interactions between incident electrons and atoms on the sample surface generate backscattered electrons,secondary electrons,and various other signals including X-rays that relay compositional and topographical information.Through selective removal or preservation of specific tissue components (organic,inorganic,cellular,vascular),their individual contribution(s) to the overall functional competence can be elucidated.With few restrictions on sample geometry and a variety of applicable sample-processing routes,a given sample may be conveniently adapted for multiple analytical methods.While a conventional SEM operates at high vacuum conditions that demand clean,dry,and electrically conductive samples,non-conductive materials (e.g.,bone) can be imaged without significant modification from the natural state using an environmental scanning electron microscope.This review highlights important insights gained into bone microstructure and pathophysiology,bone response to implanted biomaterials,elemental analysis,SEM in paleoarchaeology,3D imaging using focused ion beam techniques,correlative microscopy and in situ experiments.The capacity to image seamlessly across multiple length scales within the meso-micro-nano-continuum,the SEM lends itself to many unique and diverse applications,which attest to the versatility and user-friendly nature of this instrument for studying bone.Significant technological developments are anticipated for analysing bone using the SEM. 展开更多
关键词 scanning electron microscopy COMPREHENSIVE OVERVIEW important discoveries
暂未订购
Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study 被引量:5
8
作者 Jun Sang Yoo Seok-Woo Chang +8 位作者 So Ram Oh Hiran Perinpanayagam Sang-Min Lim Yeon-Jee Yoo Yeo-Rok Oh Sang-Bin Woo Seung-Hyun Han Qiang Zhu Kee-Yeon Kum 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第4期227-232,共6页
The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted huma... The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted human premolars(n560) were instrumented to an apical size #50/0.06 using ProF ile and treated as follows: Group 1(n510) was filled with phosphate buffered saline(PBS); Group 2(n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3(n520) was obturated orthograde with a paste of OrthoM TA(BioM TA, Seoul, Korea) and PBS; and Group 4(n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoM TA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material(IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoM TA-filled roots(Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots(Group 4). Therefore, the orthograde obturation of root canals with OrthoM TA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. 展开更多
关键词 bacterial entombment intratubular mineralization orthograde canal obturation scanning electron microscopy tag-like structure
暂未订购
Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy 被引量:1
9
作者 Melike Balikoglu-Yilmaz Tolga Yilmaz +4 位作者 Sule Cetinel Umit Taskin Ayse Banu Esen Muhittin Taskapili Timur Kose 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期534-540,共7页
AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidi... AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidiode laser.METHODS:This prospective study included 30consecutive patients with nasolacrimal duct obstruction who underwent EXT-,EN-,or TC-DCR.Thirty removed lacrimal stent fragments and conjunctival samples were cultured.The lacrimal stent biofilms were examined by scanning electron microscopy(SEM).RESULTS:Eleven(36.7%)of the 30 lacrimal stent cultures were positive for aerobic bacteria(most commonly Staphylococcus epidermidis and Pseudomonas aeruginosa).However anaerobic bacteria and fungi were not identified in the lacrimal stent cultures.Twenty-seven(90%)patients had biofilmpositive lacrimal stents.The conjunctival culture positivity after the DCR,biofilm positivity on stents,the grade of biofilm colonization,and the presence of mucus and coccoid and rod-shaped organisms did not significantly differ between any of the groups(P】0.05).However,a significant difference was found when the SEM results were compared to the results of the lacrimal stent and conjunctival cultures(P【0.001).CONCLUSION:Type of dacryocystorhinostomy(DCR)surgery did not affect the biofilm colonization of the lacrimal stents.SEM also appears to be more precise than microbiological culture for evaluating the presence of biofilms on lacrimal stents. 展开更多
关键词 biofilms nasolacrimal duct obstruction EPIPHORA DACRYOCYSTITIS scanning electron microscopy
原文传递
Ultrastructural Analysis of the Ontogenetic Development of Shoot Induced from Embryonic Axes of Costa Rican Bean Varieties (<i>Phaseolus vulgaris</i>L.) under <i>in Vitro</i>Conditions by Scanning Electronic Microscopy 被引量:1
10
作者 Marisol Jiménez Andrés Gatica +1 位作者 Ethel Sánchez Marta Valdez 《American Journal of Plant Sciences》 2012年第4期489-494,共6页
Common bean (Phaseolus vulgaris L.) is an economic important crop and one of the major grain legumes for human consumption in Latin America, Africa and Asia. A morphological study of shoot induced from embryonic axes ... Common bean (Phaseolus vulgaris L.) is an economic important crop and one of the major grain legumes for human consumption in Latin America, Africa and Asia. A morphological study of shoot induced from embryonic axes development in four Costa Rican bean varieties (Brunca, Huetar, Guaymi and Bribri) cultivated on MS media with or without 5 mg·L–1 de N6-benzylaminopurine (BAP) by scanning electron microscopy (SEM) was developed in the present work. Micrographs showed similarities and differences in the ultrastructure of the apical dome, epidermal surface, stomata and different types of trichomes in the varieties cultivated on organogenesis media. Genotypes with advantageous morphological characteristics for genetic transformation, in particular an exposed apical dome, were identified. This work will contribute to the optimization of the in vitro regeneration of four common bean varieties. 展开更多
关键词 PHASEOLUS vulgaris L BEAN In Vitro ORGANOGENESIS SHOOT scanning electron microscopy (SEM)
暂未订购
Scanning electron microscopy coupled with energydispersive X-ray spectrometry for quick detection of sulfuroxidizing bacteria in environmental water samples 被引量:1
11
作者 SUN Chengjun JIANG Fenghua +5 位作者 GAO Wei LI Xiaoyun YU Yanzhen YIN Xiaofei WANG Yong DING Haibing 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2017年第1期185-191,共7页
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not mee... Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples. 展开更多
关键词 sulfur bacteria energy-dispersive X-ray spectrometry scanning electron microscopy bacteria detection environmental water samples 16S rRNA sequencing
原文传递
IDENTIFICATION OF MARINE AEROSOL COMPONENT BY COMBINED NAA AND SCANNING ELECTRON MICROSCOPY WITH X—RAY ANALYSIS
12
作者 杨绍晋 章一鸣 《Nuclear Science and Techniques》 SCIE CAS CSCD 1992年第3期205-209,共5页
The concentrations of 30 elements in aerosol particles collected in western Pacific ocean have been determined by INAA. The crustal element concentrations decrease with increasing distance from land over the remote ar... The concentrations of 30 elements in aerosol particles collected in western Pacific ocean have been determined by INAA. The crustal element concentrations decrease with increasing distance from land over the remote area close to Asia land and fluctuate around its average value over the remote ocean area. The volatile elements exhibite average atmospheric concentrations that are higher than those expected from the flux of seasalt or the continental dust. In order to identify marine aerosol component originating from the continent or ocean, the aerosol particles are examined by scanning electron microscopy combined with energy dispersive X-ray spectroscopy. Particle phase structure shows that the crustal aerosol particles are not present internal mixtures with seasalt aerosol, and it also proves the long-range transport of crustal elements from continent to ocean. 展开更多
关键词 AEROSOL scanning electron microscopy INAA EDS
在线阅读 下载PDF
Molecular conformational effects on co-assembly systems of low-symmetric carboxylic acids investigated by scanning tunneling microscopy
13
作者 Yutong Xiong Ting Meng +3 位作者 Wendi Luo Bin Tu Shuai Wang Qingdao Zeng 《Chinese Journal of Structural Chemistry》 2025年第2期57-61,共5页
The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-d... The assembly behaviors of two low-symmetric carboxylic acid molecules(50-(6-carboxynaphthalen-2-yl)-[1,10:30,100-triphenyl]-3,400,5-tricarboxylic acid(CTTA)and 30,50-bis(6-carboxynaphthalen-2-yl)-[1,10-biphenyl]-3,5-dicarboxylic acid(BCBDA))containing naphthalene rings on graphite surfaces have been investigated using scanning tunneling microscopy(STM).The transformation of nanostructures induced by the second components(EDA and PEBP-C4)have been also examined.Both CTTA and BCBDA molecules self-assemble at the 1-heptanoic acid(HA)/HOPG interface,forming porous network structures.The dimer represents the most elementary building unit due to the formation of double hydrogen bonds.Moreover,the flipping of naphthalene ring results in the isomerization of BCBDA molecule.The introduction of carboxylic acid derivative EDA disrupts the dimer,which subsequently undergoes a structural conformation to form a novel porous structure.Furthermore,upon the addition of pyridine derivative PEBP-C4,N–H⋯O hydrogen bonds are the dominant forces driving the three coassembled structures.We have also conducted density functional theory(DFT)calculations to determine the molecular conformation and analyze the mechanisms underlying the formation of nanostructures. 展开更多
关键词 Co-assembly CONFORMATION Hydrogen bonds scanning tunneling microscopy DFT calculations
原文传递
Application of high-temperature confocal scanning laser microscopy to investigate non-metallic inclusions in steel:a review
14
作者 N.Preisser Y.Wang +3 位作者 J.Cejka I.Gruber W.Mu S.K.Michelic 《Journal of Iron and Steel Research International》 2025年第2期334-352,共19页
High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations an... High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations and solidification,this method has gained traction in the field of non-metallic inclusion in steels in recent years.An overview of the experimental capabilities of HT-CSLM and the most important results of recent investigations regarding the topics of clean steel production are provided.It includes the formation of intragranular acicular ferrite(IAF)from the surface of non-metallic inclusions during the continuous cooling and heat treatment,which can be especially beneficial in the toughness of heat-affected zones of welded pieces.Furthermore,the investigation of agglomeration mechanisms of non-metallic inclusions(NMIs)in liquid steel is discussed to improve the insight into attraction forces between particles and clogging phenomena during continuous casting.Also,the dissolution of NMIs in various steelmaking slags can be observed by HT-CSLM to compare dissolution rates and mechanisms of NMI,where significant influences of temperature and chemical composition of the slag were shown.Last but not least,the experimental work regarding the interface between steel and slag is discussed,where novel techniques are currently being developed.A comprehensive summary of experimental techniques using HT-CSLM equipment to investigate different interactions of NMIs with steel and slag phases is compiled. 展开更多
关键词 Non-metallic inclusion STEEL High-temperature confocal scanning laser microscopy Interfacial phenomenon KINETICS
原文传递
Scanning Electron Acoustic Microscopy of GaInAsSb by Metalorganic Chemical Vapor Deposition
15
作者 李树玮 金亿鑫 +3 位作者 周天明 张宝林 宁永强 蒋红 《Rare Metals》 SCIE EI CAS CSCD 1996年第2期101-105,共5页
Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and... Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and the application of scanning electron acoustic microscopy in GalnAsSb alloy grown by MOCVD wereinvestigated. Defects below the surface of GalnAsSb alloy were found by SEAM images and cathodelumi-nescence. The results show that electronacoustic imaging has its own features over secondary electron imag-ing. 展开更多
关键词 scanning electron acoustic microscopy electron-acoustic imaging GAINASSB MOCVD
在线阅读 下载PDF
Mechanism of keyhole evolution and welding quality of electron beam welded magnesium alloy with scanning path variation via modeling and numerical study
16
作者 Qianxing Yin Ziyou Yang +1 位作者 Hui Li Hejun Du 《Journal of Magnesium and Alloys》 2025年第7期3166-3185,共20页
Welding quality of electron beam welded joint is usually susceptible to the stability of keyhole during welding process.The more stable the keyhole,the better the welding quality.To reveal the evolution mechanism of k... Welding quality of electron beam welded joint is usually susceptible to the stability of keyhole during welding process.The more stable the keyhole,the better the welding quality.To reveal the evolution mechanism of keyhole and welding quality of the electron beam welded joint of magnesium-gadolinium alloy under different scanning path,numerical simulation was conducted for the changes in morphology of keyhole and liquid flow in molten pool.The magnesium-gadolinium alloy was welded by electron beam in vacuum with two different scanning paths,sinusoid path and cochleoid path,indicating the identical heat input,welding speed,and focusing state.The stability of keyhole was mainly related to the frequency of keyhole collapse.When the sinusoid scanning path was adopted,the fluids both inside the molten pool and at keyhole wall were disorder,corresponding to the numerous independent vortices and dramatically chaotic flows at their junctions.The maximum velocity of fluids ranged from 0.79 m/s to 1.02 m/s.The average and maximum depth of keyhole were 3.48 mm and 4.51 mm,respectively,meaning that the keyhole collapsed frequently.As the scanning path was changed into cochleoid mode,the electron beam scanned in a homogeneous manner without abrupt change in direction and speed like sinusoid path at its peaks and troughs.The maximum velocity of fluids was more uniform without drastic variation,ranging from 0.90 m/s to 1.01 m/s.The average and maximum depth of keyhole were decreased to 3.30 mm and 4.05 mm,respectively,indicating the more stable keyhole and alleviated collapse.Both the actual in-situ capture of molten pool signature and porosity inside the weld corresponded to the analysis of the change in keyhole stability. 展开更多
关键词 Magnesium-gadolinium alloy Keyhole stability electron beam welding scanning path Fluid flow
在线阅读 下载PDF
Study of a Novel Small Caliber Vascular Graft in a Canine Model with Optical and Scanning Electron Microscopy 被引量:1
17
作者 XU Yi-min QI Song-tao SHI Xiao-feng ZENG Shao-wen LI Wei-qiu HUANG Guang-long ZHUANG Bing-rong 《Chinese Journal of Biomedical Engineering(English Edition)》 2007年第1期22-32,共11页
A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography w... A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography was performed at the first week post-operation, and angiography was then administered to 9 grafts at 4th week, 12th week and 24th week respectively to monitor the graft pantency and blood flow characteristics. Vascular samples containing the grafts were collected at 1st week, 8th week, 12th week and 24th week after implantation. Morphological changes of the grafts were observed by optical and scanning electron microscopic (SEM) studies and compared with that of the original prosthesis and the normal host vessel. All grafts were patent throughout the experiment except one graft. Histopathology and SEM demonstrated both a nearly complete inner capsule of varied thickness lining the graft luminal surface and connective tissue adventitia formation at one-week post-operation. The neointima became confluent at 8 weeks and then compact but had no signs of hyperplasia up to 12 weeks; meanwhile on the neointimal surface newly grown endothelial-like cells were migrating from the stoma to the middle portion. The grafts also illustrated endothelialization in many “islands” in the mid-segment luminal surface of the grafts. In addition, the closer distance the cells towards the stoma were, the more morphological similarity the cells with the normal endothelial were. Taken together, the biological vascular graft remained patent for 24 weeks as a carotid prosthesis, characterized by the early and complete neointima formation plus endothelialization starting before 12 weeks post grafting. Therefore, the graft seems suitable for reconstruction of vascular lesions in dogs. Further studies may be carried out to extend the graft application for the clinical use. 展开更多
关键词 DOG Surgical implantation Common carotid artery Biological vascular graft RECONSTRUCTION HISTOPATHOLOGY scanning electron microscopy ENDOTHELIALIZATION
暂未订购
Scanning Electron Microscopy(SEM) Observations of Antennal Sensilla of Chrysopa pallens Rambur(Neuroptera:Chrysopidae)
18
作者 Wang Juan Chen Hongyin +3 位作者 Wang Mengqing Liu Chenxi Zhang Haiping Zhang Lisheng 《Plant Diseases and Pests》 CAS 2017年第2期1-4,19,共5页
[Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The ... [Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The submicroscopic structure of antennal sensilla of C. pallens was examined using scanning electron microscopy. [Results]Antennae of female and male C. pallens were linear in shape and( 1. 52 ± 0. 08) and( 1. 58 ± 0. 23) cm in length,respectively. The scape and pedicel were composed of single sub-segment,while the flagellum consisted of 116 sub-segments,on which most sensilla distributed. The flagella of female and male antennae were( 1. 44 ± 0. 04) and( 1. 47 ± 0. 13) cm in length,respectively. Nine morphological sensilla types were recorded in both sexes,including four types of highly abundant and widely distributed sensilla trichodea( ST Ⅰ,ST Ⅱ,ST Ⅲ and ST Ⅳ),three types of sensilla basiconica( SB Ⅰ,SB Ⅱ,and SB Ⅲ),and one of each type of sensilla chaetica and B9 hm bristles. Although the shape,structure,numbers,and distribution of antennae of females and males were basically similar,major differences were recorded between the sexes in the length of some sensilla types. Both the ST Ⅲ and SB Ⅰ in female adults were significantly longer than that in male ones. Notably,SB Ⅱ was found only in female. [Conclusions]The paper laid a foundation for revealing the relationship between smell and behavior,playing a crucial role in promoting the important biological control effect of C. pallens in farmland ecological system. 展开更多
关键词 Chrysopa pallens ANTENNA SENSILLA ULTRASTRUCTURE scanning electron microscopy
在线阅读 下载PDF
Electronic phase diagram of NaFe_(1-x)Co_xAs investigated by scanning tunneling microscopy
19
作者 周晓东 蔡鹏 王亚愚 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第8期171-180,共10页
Our recent scanning tunneling microscopy (STM) studies of the NaFelxCoxAs phase diagram over a wide range of dopings and temperatures are reviewed. Similar to the high-Tc cuprates, the iron-based superconductors lie... Our recent scanning tunneling microscopy (STM) studies of the NaFelxCoxAs phase diagram over a wide range of dopings and temperatures are reviewed. Similar to the high-Tc cuprates, the iron-based superconductors lie in close proximity to a magnetically ordered phase. Therefore, it is widely believed that magnetic interactions or fluctuations play an important role in triggering their Cooper pairings. Among the key issues regarding the electronic phase diagram are the properties of the parent spin density wave (SDW) phase and the superconducting (SC) phase, as well as the interplay between them. The NaFe l-xCoxAs is an ideal system for resolving these issues due to its rich electronic phases and the charge-neutral cleaved surface. In our recent work, we directly observed the SDW gap in the parent state, and it exhibits unconventional features that are incompatible with the simple Fermi surface nesting picture. The optimally doped sample has a single SC gap, but in the underdoped regime we directly viewed the microscopic coexistence of the SDW and SC orders, which compete with each other. In the overdoped regime we observed a novel pseudogap-like feature that coexists with supercon- ductivity in the ground state, persists well into the normal state, and shows great spatial variations. The rich electronic structures across the phase diagram of NaFel_xCoxAs revealed here shed important new light for defining microscopic models of the iron-based superconductors. In particular, we argue that both the itinerant electrons and local moments should be considered on an equal footing in a realistic model. 展开更多
关键词 iron-based superconductor scanning tunneling microscopy spin-density wave SUPERCONDUCTIVITY
原文传递
OBSERVATION AND ANALYSIS OF BLOOD CONTACTING SURFACE OF LEFT VENTRICULAR ASSIST DEVICE WITH SCANNING ELECTRON MICROSCOPY
20
作者 王惠荪 金永安 秦家楠 《Medical Bulletin of Shanghai Jiaotong University》 CAS 1989年第Z1期72-78,共7页
Thrombus formation in the artificial heart blood pump is a complex problem. The most important factor of thrombosis in the blood pump is the quality of blood contacting surface which is related to hemocompatibility of... Thrombus formation in the artificial heart blood pump is a complex problem. The most important factor of thrombosis in the blood pump is the quality of blood contacting surface which is related to hemocompatibility of materials and micromorphololgy or roughness of the surface. So it is necessary to understand the morphology of the surface inside of blood pump in order to develop and improve a good quality blood pump. The authors observed and analysed the inner surface of blood pumps (both preimplanted and postimplanted) with scanning electron microscopy (SEM) providing a means for evaluating the blood pumps and for developing good quality of blood pumps. It was observed that there were four kinds of surface defects on the inner surface of the blood pumps: air bubble domes, open bubble craters, contaminated dust and gel particles. Microcrakes had also been found on the diaphragm of the postimplanted pump. But in the newly improved blood pump that had been imlanted for 16 days, there were few defects on the blood contacting surface, and only a little fibrinous layer observed. It could be considered that the current design and modifications are reasonable. Since some problems associated with the surface defects and thrombosis still existed, further improvement in fabrication process and quality control procedures with SEM are under way. 展开更多
关键词 LEFT VENTRICULAR assist device scanning electron microscopy POLYURETHANE BLOOD contacting SURFACE SURFACE defects THROMBOSIS
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部