A method of data processing to determine the coefficients of linearization equations for 1050 anemometer (produced by Thermo-Systems Inc. -TSI, USA) with the sensors made of domestic hot wire using the program preferr...A method of data processing to determine the coefficients of linearization equations for 1050 anemometer (produced by Thermo-Systems Inc. -TSI, USA) with the sensors made of domestic hot wire using the program preferred in this Paper is described. By calculation and test, it is indicated that the error resulting from this method is about 0. 5% of the full scale and less than TSl's. By using this method we can set up the calibration curve according to the measurement range and the diameter of the hot wire at a certain accuracy.展开更多
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we...An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its effectiveness experimentally for hot-wires of 5 μm, 10 μm and 20 μm in diameter. Then, another novel technique based on a two-sensor probe technique—originally developed for the response compensation of fine-wire thermocouples (Tagawa and Ohta 1997;Tagawa et al. 1998)—has been proposed for estimating thermal time-constants of hot-wires to realize the in-situ response compensation of the CCA. To demonstrate the usefulness of the CCA, we have applied the response compensation schemes to multipoint velocity measure- ment of a turbulent wake flow formed behind a circular cylinder by using a CCA probe consisting of 16 hot-wires, which were driven simultaneously by a very simple constant-current circuit. As a result, the proposed response compensation techniques for the CCA work quite successfully and are capable of improving the response speed of the CCA to obtain reliable measurements comparable to those by the commercially-available constant-temperature hot-wire anemometer (CTA).展开更多
GeSi:H films are prepared by hot-wire chemical vapor deposition(CVD)with high hydrogen dilution,DH=98%.Effects of hot wire temperature(Tw)on deposition rate,structural properties and bandgap of GeSi:H films are studie...GeSi:H films are prepared by hot-wire chemical vapor deposition(CVD)with high hydrogen dilution,DH=98%.Effects of hot wire temperature(Tw)on deposition rate,structural properties and bandgap of GeSi:H films are studied with surface profilemeter,Raman spectroscopy,Fourier transformed infrared spectroscopy,and UV-VIS-NIR spectrophotometer.It is found that the deposition rate(Rd)goes up with increasing of Tw,but increasing rate of Rd declines when Tw≥1550℃.High Tw is beneficial to the formation of Ge-Si,but it has little effect on relative contents of the hydrogen bonds(Ge-H,Si-H,etc.)in the films.In the Tw range of 1400-1850℃,the maximum bandgap of the GeSi:H films is 1.39 eV at Tw=1450℃and the band gap decreases with Tw increasing when Tw≥1450℃.展开更多
The goal of this study is to develop an airflow meter sensor for vehicle intake system detection in internal combustion engines. The study uses micro-electromechanical process technology to develop a hot-film flow met...The goal of this study is to develop an airflow meter sensor for vehicle intake system detection in internal combustion engines. The study uses micro-electromechanical process technology to develop a hot-film flow meter with an alumina substrate and platinum film heater;the hotline method is used to create a micro airflow anemometry meter sensor relying on variations in resistance of the platinum film corresponding to different wind velocity at the set temperatures. The micro-sensor is less bulky and simpler structure than ordinary meters, and its small size enables it to provide good sensitivity and measurement precision. The alumina plate used in this study is produced by polishing an alumina substrate, a platinum film is then deposited on the plate to complete the micro-heater used in the sensor. Resistance on the sensor side varies as gas flows through the sensor, and the instrument determines airflow velocity on the basis of the changes in resistance caused by gas flow differences. Airflow velocity form 10 m/s to 60 m/s are used to test. Resistance displays a regular slope, indicating the relationship between airflow velocities varies remain predictable throughout the sensing range. Therefore, the sensor can achieve its airflow measurement purpose completely.展开更多
In order to gain a better knowledge of the mechanisms and to calibrate computational fluid dynamics (CFD) tools including both Reynolds-averaged Navier-Stokes (RANS) and large eddy simulation (LES), a detailed a...In order to gain a better knowledge of the mechanisms and to calibrate computational fluid dynamics (CFD) tools including both Reynolds-averaged Navier-Stokes (RANS) and large eddy simulation (LES), a detailed and accurate experimental study of comer stall in a linear compressor cascade has been carried out. Data are taken at a Reynolds number of 382 000 based on blade chord and inlet velocity. At first, inlet flow boundary layer is surveyed using hot-wire anemometry. Then in order to investigate the effects of incidence, measurements are acquired at five incidences, including static pressures on both blade and endwall sur- faces measured by pressure taps and the total pressure losses of outlet flow measured by a five-hole pressure probe. The maxi- mum losses as well as the extent of losses of the comer stall are presented as a function of the investigated incidences.展开更多
Flow visualization and hot-wire measurement techniques were combined to investigate the influence of the size and number of tabs on jet flow field and vortex structure generation mechanism. Streamwise vortices generat...Flow visualization and hot-wire measurement techniques were combined to investigate the influence of the size and number of tabs on jet flow field and vortex structure generation mechanism. Streamwise vortices generated by the tabs of different sizes and numbers were observed from the flow visualization images. Combined with flow visualization, hot-wire measurement gave a quantitative insight of the effect of various tabbed jet flows. Instantaneous two-component velocity signals (longitudinal and transverse velocity components) at different cross sections along radius direction and streamwise direction with different tabbed jet nozzles were measured using hot-wire anemometer. Average flow field parameters of tabbed jet flow such as mean velocity, tur-bulence intensity, vorticity were analyzed and the effects of tabs with different sizes and numbers were compared with that of circular no-tab jet flow. It is revealed that the generation of a series of counter-rotating quasi-streamwise vortices, azimuthal vortices and double-row azi-muthal vortex are the reasons for mixing enhancement of tabbed turbulent jet flow.展开更多
文摘A method of data processing to determine the coefficients of linearization equations for 1050 anemometer (produced by Thermo-Systems Inc. -TSI, USA) with the sensors made of domestic hot wire using the program preferred in this Paper is described. By calculation and test, it is indicated that the error resulting from this method is about 0. 5% of the full scale and less than TSl's. By using this method we can set up the calibration curve according to the measurement range and the diameter of the hot wire at a certain accuracy.
文摘An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its effectiveness experimentally for hot-wires of 5 μm, 10 μm and 20 μm in diameter. Then, another novel technique based on a two-sensor probe technique—originally developed for the response compensation of fine-wire thermocouples (Tagawa and Ohta 1997;Tagawa et al. 1998)—has been proposed for estimating thermal time-constants of hot-wires to realize the in-situ response compensation of the CCA. To demonstrate the usefulness of the CCA, we have applied the response compensation schemes to multipoint velocity measure- ment of a turbulent wake flow formed behind a circular cylinder by using a CCA probe consisting of 16 hot-wires, which were driven simultaneously by a very simple constant-current circuit. As a result, the proposed response compensation techniques for the CCA work quite successfully and are capable of improving the response speed of the CCA to obtain reliable measurements comparable to those by the commercially-available constant-temperature hot-wire anemometer (CTA).
基金Supported by the National Key Research and Development Program of China(2018YFB1500400-2018YFB1500403)the National Natural Science Foundation of China(61741404,61464007)the Jiangxi Provincial Key Research and Development Foundation(2016BBH80043)
文摘GeSi:H films are prepared by hot-wire chemical vapor deposition(CVD)with high hydrogen dilution,DH=98%.Effects of hot wire temperature(Tw)on deposition rate,structural properties and bandgap of GeSi:H films are studied with surface profilemeter,Raman spectroscopy,Fourier transformed infrared spectroscopy,and UV-VIS-NIR spectrophotometer.It is found that the deposition rate(Rd)goes up with increasing of Tw,but increasing rate of Rd declines when Tw≥1550℃.High Tw is beneficial to the formation of Ge-Si,but it has little effect on relative contents of the hydrogen bonds(Ge-H,Si-H,etc.)in the films.In the Tw range of 1400-1850℃,the maximum bandgap of the GeSi:H films is 1.39 eV at Tw=1450℃and the band gap decreases with Tw increasing when Tw≥1450℃.
文摘The goal of this study is to develop an airflow meter sensor for vehicle intake system detection in internal combustion engines. The study uses micro-electromechanical process technology to develop a hot-film flow meter with an alumina substrate and platinum film heater;the hotline method is used to create a micro airflow anemometry meter sensor relying on variations in resistance of the platinum film corresponding to different wind velocity at the set temperatures. The micro-sensor is less bulky and simpler structure than ordinary meters, and its small size enables it to provide good sensitivity and measurement precision. The alumina plate used in this study is produced by polishing an alumina substrate, a platinum film is then deposited on the plate to complete the micro-heater used in the sensor. Resistance on the sensor side varies as gas flows through the sensor, and the instrument determines airflow velocity on the basis of the changes in resistance caused by gas flow differences. Airflow velocity form 10 m/s to 60 m/s are used to test. Resistance displays a regular slope, indicating the relationship between airflow velocities varies remain predictable throughout the sensing range. Therefore, the sensor can achieve its airflow measurement purpose completely.
基金National Natural Science Foundation of China(50976010)"111" Project (B08009)
文摘In order to gain a better knowledge of the mechanisms and to calibrate computational fluid dynamics (CFD) tools including both Reynolds-averaged Navier-Stokes (RANS) and large eddy simulation (LES), a detailed and accurate experimental study of comer stall in a linear compressor cascade has been carried out. Data are taken at a Reynolds number of 382 000 based on blade chord and inlet velocity. At first, inlet flow boundary layer is surveyed using hot-wire anemometry. Then in order to investigate the effects of incidence, measurements are acquired at five incidences, including static pressures on both blade and endwall sur- faces measured by pressure taps and the total pressure losses of outlet flow measured by a five-hole pressure probe. The maxi- mum losses as well as the extent of losses of the comer stall are presented as a function of the investigated incidences.
基金National Natural Science Foundation of China (No.10472081)Program for New Century Excellent Talents in Universities of Minis-try of Education of China and Plan of Tianjin Science and Technology Development (No.06TXTJJC13800)
文摘Flow visualization and hot-wire measurement techniques were combined to investigate the influence of the size and number of tabs on jet flow field and vortex structure generation mechanism. Streamwise vortices generated by the tabs of different sizes and numbers were observed from the flow visualization images. Combined with flow visualization, hot-wire measurement gave a quantitative insight of the effect of various tabbed jet flows. Instantaneous two-component velocity signals (longitudinal and transverse velocity components) at different cross sections along radius direction and streamwise direction with different tabbed jet nozzles were measured using hot-wire anemometer. Average flow field parameters of tabbed jet flow such as mean velocity, tur-bulence intensity, vorticity were analyzed and the effects of tabs with different sizes and numbers were compared with that of circular no-tab jet flow. It is revealed that the generation of a series of counter-rotating quasi-streamwise vortices, azimuthal vortices and double-row azi-muthal vortex are the reasons for mixing enhancement of tabbed turbulent jet flow.