期刊文献+
共找到443篇文章
< 1 2 23 >
每页显示 20 50 100
Computed tomography pulmonary angiography using a 20% reduction in contrast medium dose delivered in a multiphasic injection 被引量:3
1
作者 Mitchell Chen Gaith Mattar Jamal A Abdulkarim 《World Journal of Radiology》 CAS 2017年第3期143-147,共5页
AIM To evaluate the feasibility of reducing the dose of iodinated contrast agent in computed tomography pulmonary angiography(CTPA). METHODS One hundred and twenty-seven patients clinically suspected of having pulmona... AIM To evaluate the feasibility of reducing the dose of iodinated contrast agent in computed tomography pulmonary angiography(CTPA). METHODS One hundred and twenty-seven patients clinically suspected of having pulmonary embolism underwent spiral CTPA, out of whom fifty-seven received 75 mL and the remaining seventy a lower dose of 60 mL of contrast agent. Both doses were administered in a multiphasic injection. A minimum opacification threshold of 250 Hounsfield units(HU) in the main pulmonary artery is used for assessing the technical adequacy of the scans. RESULTS Mean opacification was found to be positively correlated to patient age(Pearson's correlation 0.4255, P < 0.0001) and independent of gender(male:female, 425.6 vs 450.4,P = 0.34). When age is accounted for, the study and control groups did not differ significantly in their mean opacification in the main(436.8 vs 437.9, P = 0.48),left(416.6 vs 419.8, P = 0.45) or the right pulmonary arteries(417.3 vs 423.5, P = 0.40). The number of sub-optimally opacified scans(the mean opacification in the main pulmonary artery < 250 HU) did not differ significantly between the study and control groups(7 vs 10).CONCLUSION A lower dose of iodine contrast at 60 mL can be feasibly used in CTPA without resulting in a higher number of sub-optimally opacified scans. 展开更多
关键词 Computed tomography pulmonary angiography contrast dose contrast induced nephropathy Acute kidney disease contrast safety contrast dose reduction Multiphasic injection
暂未订购
Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors 被引量:1
2
作者 Tong Yu Jun Gao +4 位作者 Zhi-Min Liu Qi-Feng Zhang Yong Liu Ling Jiang Yon Peng 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第7期823-831,共9页
Background:Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully,but there have been few studies on the application of low-concentration contrast i... Background:Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully,but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations.This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors.Methods:Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled.The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast,and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode.Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A.In addition,filtered back-projection (FBP) reconstruction was used for monochromatic images 〈60 keV in Group A.The total radiation dose,total iodine load,contrast injection speed,and maximum injection pressure were compared between the two groups.The 40 keV and 60 keV spectral CT images of Group A were compared with the images of Group B to evaluate overall image quality.Results:The total radiation dose,total iodine load,injection speed,and maximum injection pressure for Group A were decreased by 19%,15%,34.4%,and 18.3%,respectively.The optimal energy level in spectral CT for displaying the abdominal vessels was 40 keV.At this level,the CT values in the abdominal aorta and its three branches,the portal vein and its two branches,and the inferior vena cava were all greater than 340 hounsfield unit (HU).The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t =0.36 and-1.716 for liver,0.153 and-1.546 for pancreas,and 2.427 and 0.866 for renal cortex,all P 〉 0.05).Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t =-8.11 for liver,-7.83 for pancreas,and-5.38 for renal cortex,all P 〈 0.05).However,the subjective scores for the 40 keV (FBP) and 60 keV (40% ASiR) spectral CT images determined by two radiologists were all 〉3,indicating clinically acceptable image quality.Conclusions:Single-phase,dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality. 展开更多
关键词 contrast dose Reduction PEDIATRIC Radiation dose Reduction Solid Tunlors
原文传递
Low contrast medium and radiation dose for hepatic computed tomography perfusion of rabbit VX2 tumor 被引量:2
3
作者 Cai-Yuan Zhang Yan-Fen Cui +4 位作者 Chen Guo Jing Cai Ya-Fang Weng Li-Jun Wang Deng-Bin Wang 《World Journal of Gastroenterology》 SCIE CAS 2015年第17期5259-5270,共12页
AIM:To evaluate the feasibility of low contrast medium and radiation dose for hepatic computed tomography(CT) perfusion of rabbit VX2 tumor.METHODS:Eleven rabbits with hepatic VX2 tumor underwent perfusion CT scanning... AIM:To evaluate the feasibility of low contrast medium and radiation dose for hepatic computed tomography(CT) perfusion of rabbit VX2 tumor.METHODS:Eleven rabbits with hepatic VX2 tumor underwent perfusion CT scanning with a 24-h interval between a conventional tube potential(120 k Vp) protocol with 350 mg I/m L contrast medium and filtered back projection,and a low tube potential(80 k Vp) protocol with 270 mg I/m L contrast medium with iterative reconstruction.Correlation and agreement among perfusion parameters acquired by the conventional and low dose protocols were assessed for the viable tumor component as well as whole tumor.Image noise and tumor-to-liver contrast to noise ratio during arterial and portal venous phases were evaluated.RESULTS:A 38% reduction in contrast medium dose(360.1 ± 13.3 mg I/kg vs 583.5 ± 21.5 mg I/kg,P < 0.001) and a 73% decrease in radiation dose(1898.5 m Gy·cm vs 6951.8 m Gy·cm) were observed.Interestingly,there was a strong positive correlation in hepatic arterial perfusion(r = 0.907,P < 0.001;r = 0.879,P < 0.001),hepatic portal perfusion(r = 0.819,P = 0.002;r = 0.831,P = 0.002),and hepatic blood flow(r = 0.945,P < 0.001;r = 0.930,P < 0.001) as well as a moderate correlation in hepatic perfusion index(r = 0.736,P = 0.01;r = 0.636,P = 0.035) between the low dose protocol with iterative reconstruction and the conventional protocol for the viable tumor component and the whole tumor.These two imaging protocols provided a moderate but acceptable agreement for perfusion parameters and similar tumorto-liver CNR during arterial and portal venous phases(5.63 ± 2.38 vs 6.16 ± 2.60,P = 0.814;4.60 ± 1.27 vs 5.11 ± 1.74,P = 0.587).CONCLUSION:Compared with the conventional protocol,low contrast medium and radiation dose with iterative reconstruction has no significant influence on hepatic perfusion parameters for rabbits VX2 tumor. 展开更多
关键词 LOW radiation dose LOW concentrationcontrast MEDIUM PERFUSION COMPUTED tomography Liver VX2 tumor
暂未订购
Clinical Outcome of Low Dose Contrast during Percutaneous Coronary Intervention in Patients with Moderate to Severe Kidney Impairment
4
作者 Wassam Eldin Elshafey Walaa Farid Abdel Aziz +1 位作者 Ahmed Magdy Kamal Eldin Mohamed Mahmoud Khattab 《World Journal of Cardiovascular Diseases》 2019年第11期781-795,共15页
Background: Chronic kidney disease patients are at a greater risk for nephropathy requiring dialysis after percutaneous coronary intervention. Such patients are usually deferred due to fear of “Renalism”.?Objectives... Background: Chronic kidney disease patients are at a greater risk for nephropathy requiring dialysis after percutaneous coronary intervention. Such patients are usually deferred due to fear of “Renalism”.?Objectives This study assesses the outcome of Low dose contrast protocol during PCI in CKD patients whose e-GFR 60 ml/min/1.72 m and investigates a safety margin for contrast use in these high-risk categories.?Methods: Patients were into three groups according to CV/e-GFR ratio: Group (A) low-dose: CV/e-GFR ratio 2.0 Group (B) medium-dose: CV/e-GFR ratio > 2.0 and × bodyweight\s.creatinine). Group (C) high-dose: CV/e-GFR ratio > MACD. Results: A total of 73 patients were enrolled. Average age was 54 ± 8 years,81.4% were male and 18.6% were females and 52% were diabetic. Mean baseline e-GFR was 40 ± 8.0 ml/min/1.73m2. Contrast Volume used in group A was (58.26 ± 15.05) (n = 24), in group B (109.42 ± 17.11) (n = 26) and in group C (304.5 ± 60.30) (n = 23), respectively. The incidences of CI-AKI in the 3 groups were 0%, 11.5% and 35%, respectively (p = 0.02). All-cause death 0%, 17% and introduction of maintenance hemo dialysis was 0%, 11.5% and 26%, respectively (p Conclusion: Low dose contrast protocol is safe, effective and easily applicable technique without CI-AKI or death. 展开更多
关键词 Chronic KIDNEY Disease (CKD) Maximum Allowed contrast dose (MACD) contrast Induced Acute KIDNEY Injury (CI-AKI) Low dose Protocol contrast Volume to e-GFR Ratio
暂未订购
迭代模型重建与iDose4混合迭代重建在头颈部低剂量CT血管成像中的应用比较 被引量:3
5
作者 朱维聪 曾慧芸 +2 位作者 杜晨 吴雅婷 王彬 《影像诊断与介入放射学》 2024年第3期193-199,共7页
目的探讨迭代模型重建(IMR)对比iDose4混合迭代重建技术在低辐射剂量和低碘摄入量头颈部CT血管成像(CTA)中的应用比较。方法收集本院2024年1月—5月因需行头颈部联合动脉CTA检查,且身体质量指数不超过30 kg/m2的患者60例,分为对照组和... 目的探讨迭代模型重建(IMR)对比iDose4混合迭代重建技术在低辐射剂量和低碘摄入量头颈部CT血管成像(CTA)中的应用比较。方法收集本院2024年1月—5月因需行头颈部联合动脉CTA检查,且身体质量指数不超过30 kg/m2的患者60例,分为对照组和实验组,每组各30例。对照组采用120 kV、150 mAs、对比剂用量50 mL、注射流率5 mL/s和iDose4重建;实验组采用100 kV、100 mAs、对比剂用量30 mL、注射流率3 mL/s,分别使用iDose4和IMR进行图像重建,得到iDsoe4组和IMR组两组重建图像。测量并计算三组图像左侧颈总动脉起始部、左侧颈内动脉起始部和大脑中动脉M1段血管CT值、标准差(SD)、信噪比(SNR)和对比噪声比(CNR);记录并比较对照组和实验组病例容积CT剂量指数、剂量长度乘积,并计算有效剂量。2名诊断医师对图像质量进行主观评分。辐射剂量的比较采用独立样本t检验;CT值、SD、SNR、CNR、主观质量评分的比较采用方差分析或韦尔奇检验,两两比较采用LSD-t检验或Tamhane’s T2检验。结果对照组与IMR组各血管主观质量评分、SD、SNR、CNR的比较差异均无显著性(P>0.05);iDose4组各血管主观质量评分、SNR、CNR均明显低于对照组和IMR组,差异具有显著性(P<0.05);对照组各对应血管的CT值均明显高于iDose4组和IMR组,差异具有显著性(P<0.05);实验组有效剂量(1.62±0.08)较对照组(0.69±0.33)下降了约57.41%,对比剂碘摄入量减少了40%。结论在头颈部CTA检查中,采用低管电压、低管电流、低注射剂量及低注射流率联合IMR技术,可在保证图像质量的同时显著地降低患者辐射剂量和碘摄入量,IMR技术在降低图像噪声、提高图像SNR和CNR方面优于iDose4重建。 展开更多
关键词 迭代模型重建 辐射剂量 对比剂 CT血管成像
暂未订购
Optimization of Contrast Material Dose for Abdominal Multi-Detector Row CT: Predicting Patient Lean Body Weight by Using Preliminary Transverse CT Images
6
作者 Antonino Guerrisi Daniele Marin +4 位作者 Huiman Barnhart Lisa Ho Thomas L. Toth Carlo Catalano Rendon C. Nelson 《Advances in Computed Tomography》 2014年第1期1-10,共10页
Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detec... Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detector row computed tomographic (MDCT) abdominal image, using a bioelectrical body composition analyzer scale as the reference standard. CT images of 21 patients with previously measured LBW (mLBW) were processed using computer-assisted, vendor-specific software (Advantage Windows 4.2;GE Healthcare, Inc). For each transverse image, a fat-fraction was automatically measured as the number of fat pixels (-200 to -50 HU) divided by the total number of pixels having an attenuation value ≥-200 HU. Estimated LBW (eLBW) of five single contiguous sections was calculated in each of three abdominal regions (upper abdomen, mid abdomen and pelvis) by multiplying TBW by (1 – fat-fraction). Bland-Altman plot with limits of agreement was used to assess agreement between mLBW and eLBW. The mean mLBW for all patients was 56 kg (range, 39 - 75 kg). Mean differences and limits of agreement between mLBW and eLBW measurements for the upper abdomen, mid abdomen and pelvis reported were -8.9 kg (-25.6 kg, +7.5 kg), -10.6 kg (-27.7 kg, +6.4 kg), and +0.5 kg (-12.8 kg, +13.8 kg) respectively. eLBW deriving directly from a transverse CT image of the pelvis can accurately predict mLBW. 展开更多
关键词 LEAN Body WEIGHT Multi-Detector CT contrast dose
暂未订购
Effects of oral contrast on dose in abdominopelvic computed tomography with pure iterative reconstruction
7
作者 Kevin P Murphy Liam J Healy +5 位作者 Lee Crush Maria Twomey Fiachra Moloney Sylvia Sexton Owen J O'Connor Michael M Maher 《World Journal of Radiology》 CAS 2016年第9期809-815,共7页
AIM To assess the effect of neutral(NC) and positive(PC) oral contrast use on patient dose in low-dose abdominal computed tomography(CT).METHODS Low-dose clinically indicated CTs were performed on 79 Crohn's patie... AIM To assess the effect of neutral(NC) and positive(PC) oral contrast use on patient dose in low-dose abdominal computed tomography(CT).METHODS Low-dose clinically indicated CTs were performed on 79 Crohn's patients(35 = PC, 1 L 2% gastrografin; 44 = NC, 1.5 L polyethylene glycol). Scanner settings for both acquisitions were identical apart from 25 s difference in intravenous contrast timing. Body mass index(BMI), scan-ranges, dose-length product and size-specific dose estimated were recorded. Data was reconstructed with pure model-based iterative reconstruction. Image quality was objectively and subjectively analysed. Data analysis was performed with Statistical Package for Social Scientists.RESULTS Higher doses were seen in neutral contrast CTs(107.60 ± 78.7 m Gy.cm, 2.47 ± 1.21 m Gy vs 85.65 ± 58.2 m Gy.cm, 2.18 ± 0.96 m Gy). The differencehad both NC and PC investigations. Image-quality assessment yielded 6952 datapoints. NC image quality was significantly superior(P < 0.001)(objective noise, objective signal to noise ratio, subjective spatial resolution, subjective contrast resolution, diagnostic acceptability) at all levels. NC bowel distension was significantly(P < 0.001) superior.CONCLUSION The use of polyethylene glycol as a neutral OC agent leads to higher radiation doses than standard positive contrast studies, in low dose abdominal CT imaging. This is possibly related to the osmotic effect of the agent resulting in larger intraluminal fluid volumes and resultant increased overall beam attenuation. 展开更多
关键词 Radiation dose Low dose COMPUTED TOMOGRAPHY ABDOMINAL imaging Oral contrast COMPUTED TOMOGRAPHY
暂未订购
双能量CT虚拟平扫代替真实平扫用于降低克罗恩病小肠造影辐射剂量
8
作者 武鹏飞 李大鹏 +1 位作者 王传兵 江月 《CT理论与应用研究(中英文)》 2025年第5期891-897,共7页
目的:探讨双能量CT虚拟平扫(VNC)代替真实平扫(TNC)用于降低克罗恩病小肠造影辐射剂量的应用价值。方法:获取2024年6月至2024年12月在南京医科大学第一附属医院53例克罗恩患者双能量小肠造影图像,利用双能量分析软件重建获得动脉期和静... 目的:探讨双能量CT虚拟平扫(VNC)代替真实平扫(TNC)用于降低克罗恩病小肠造影辐射剂量的应用价值。方法:获取2024年6月至2024年12月在南京医科大学第一附属医院53例克罗恩患者双能量小肠造影图像,利用双能量分析软件重建获得动脉期和静脉期的虚拟平扫图像,采用单因素方差分析对常规平扫和动、静脉期虚拟平扫图像的CT值、信号噪声比(SNR)、对比噪声比(CNR)进行评价;采用5分法对图像质量进行主观评价,采用秩和检验分析。结果:TNC、VNCa及VNCv的图像质量主观评分分别为4(4,5)、4(4,5)、4(4,5),且差异不具有统计学意义。TNC、VNCa及VNCv之间,病变肠壁、正常肠壁、下腔静脉、竖脊肌、肝脏的CT值差异不具有统计学意义。病变肠壁、正常肠壁、腹主动脉、下腔静脉、肝脏的SNR值差异具有统计学意义且VNCa及VNCv的SNR值均高于TNC。病变肠壁、正常肠壁、下腔静脉、肝脏的CNR值差异不具有统计学意义。VNCv较TNC小肠CT造影(CTE)扫描的辐射剂量大约降低了30%。结论:双能量CT虚拟平扫代替真实平扫在保证图像质量的同时可以降低克罗恩病小肠造影辐射剂量,可以在临床应用中推广。 展开更多
关键词 辐射剂量 虚拟平扫 小肠造影 克罗恩病
原文传递
优化碘对比剂剂量联合低管电压在头颈部CTA中的应用价值
9
作者 浦昌洪 吴英宁 +1 位作者 马时敬 李保生 《右江医学》 2025年第9期810-814,共5页
目的探讨在头颈部CT血管成像(CTA)中低碘对比剂剂量联合低管电压的应用价值。方法采用前瞻性研究,将120例接受头颈部CTA检查的患者随机分为两组(每组60例),分别采用不同的扫描和对比剂注射方案。研究组使用低剂量碘对比剂(5 mL)、80 kV... 目的探讨在头颈部CT血管成像(CTA)中低碘对比剂剂量联合低管电压的应用价值。方法采用前瞻性研究,将120例接受头颈部CTA检查的患者随机分为两组(每组60例),分别采用不同的扫描和对比剂注射方案。研究组使用低剂量碘对比剂(5 mL)、80 kV管电压和0.6 mL/kg对比剂剂量;对照组使用标准剂量碘对比剂(15 mL)、100 kV管电压和0.9 mL/kg对比剂剂量。比较两组的基本信息、图像质量评分、主要血管的信噪比(SNR)和对比噪声比(CNR),以及CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)和碘对比剂用量。结果在年龄、性别、BMI及图像质量主观评分方面,两组患者差异无统计学意义(P>0.05),主要血管SNR与CNR在两组间差异亦无统计学意义(P>0.05)。研究组的CTDIvol、DLP、ED及碘对比剂用量均显著低于对照组,差异有统计学意义(P<0.05)。结论在头颈部CTA扫描过程中合理优化碘对比剂用量并降低管电压,可以保证图像质量并符合诊断要求,且能减少患者接受的辐射剂量及碘对比剂摄入量;但低的有效管电压值及更优化的对比剂使用量,仍需进一步探索。 展开更多
关键词 头颈部 CT血管成像 碘对比剂 管电压 辐射剂量
暂未订购
双能CT虚拟平扫对比传统平扫在舌癌的图像质量及辐射剂量研究
10
作者 高闯 苏赟 +1 位作者 陈晓红 曾彦钦 《临床放射学杂志》 北大核心 2025年第8期1408-1413,共6页
目的评估双能量CT(DECT)生成的虚拟平扫成像(VNC)图像在舌癌评估中的临床可行性。方法纳入60例确诊为舌癌的患者,所有患者均接受DECT扫描,获取动脉期和静脉期的VNC图像(VNCA和VNCV)。通过五分制评分法评估图像质量,计算舌部肿瘤的CT值... 目的评估双能量CT(DECT)生成的虚拟平扫成像(VNC)图像在舌癌评估中的临床可行性。方法纳入60例确诊为舌癌的患者,所有患者均接受DECT扫描,获取动脉期和静脉期的VNC图像(VNCA和VNCV)。通过五分制评分法评估图像质量,计算舌部肿瘤的CT值、信噪比(SNR)和对比噪声比(CNR),并与传统平扫(TNC)图像进行对比。辐射剂量通过CT容积剂量指数(CTDIvol)和剂量长度积(DLP)进行评估。数据采用R语言统计软件进行分析,比较VNC和TNC之间的差异。结果VNC图像在图像质量、SNR和CNR方面与TNC无显著差异(P>0.05)。在图像除碘方面,VNC与TNC也未见明显差异(P>0.05)。然而,与常规三期CT扫描相比,DECT虚拟平扫的辐射剂量显著降低(P<0.05),有效减少了患者辐射暴露。结论DECT生成的VNC在舌癌的影像学评估中与TNC相当,同时具有显著降低辐射剂量的优势。VNC图像在保证图像质量的前提下,能够为舌癌的早期诊断和治疗决策提供有价值的影像信息,具有重要的临床应用前景。 展开更多
关键词 双能量CT 虚拟平扫成像 辐射剂量 舌癌
原文传递
放射科对比剂按剂量计费管理模式的探索与实践
11
作者 黄仙丹 陈燕 +5 位作者 陈维敏 黄金标 戴锦 陈晨 毛玲红 陈姬雅 《医院管理论坛》 2025年第5期25-27,共3页
临床上增强CT检查需要使用对比剂来增强图像对比度,从而提高诊断的准确性。然而,目前厂家提供的对比剂规格与临床实际用量不一致,实际用量小于药品规格,导致药品结余。由于国家相关政策缺失,结余药品按有害垃圾处理,造成药品资源浪费。... 临床上增强CT检查需要使用对比剂来增强图像对比度,从而提高诊断的准确性。然而,目前厂家提供的对比剂规格与临床实际用量不一致,实际用量小于药品规格,导致药品结余。由于国家相关政策缺失,结余药品按有害垃圾处理,造成药品资源浪费。本研究以问题为导向,通过多部门沟通协作,在台州区域内率先推行对比剂拆零后按剂量计费,通过合理科学的管理模式,减少药品资源浪费,减轻患者经济负担,降低医保基金支出,为医院解决结余药品浪费问题提供参考。 展开更多
关键词 增强 对比剂 拆零 按剂量计费 结余药品
暂未订购
Dose Reduction技术结合低管电压技术在降低胸部增强CT辐射剂量的价值 被引量:3
12
作者 刘琦 徐凯 +3 位作者 张秀莉 程丽 赵玉侠 刘忠啸 《临床放射学杂志》 CSCD 北大核心 2015年第8期1302-1306,共5页
目的探讨基于自适应系统迭代算法(ASiR)的Dose Reduction(DR)技术结合低管电压(100 kV)技术在降低胸部增强CT辐射剂量的应用价值。方法搜集行胸部增强CT检查连续病例90例(18.5 kg/m2≤BMI≤27kg/m2)分为三组(每组30例),A组:120 kV+自动m... 目的探讨基于自适应系统迭代算法(ASiR)的Dose Reduction(DR)技术结合低管电压(100 kV)技术在降低胸部增强CT辐射剂量的应用价值。方法搜集行胸部增强CT检查连续病例90例(18.5 kg/m2≤BMI≤27kg/m2)分为三组(每组30例),A组:120 kV+自动mA(NI=12),DR=0,FBP重建;B组:120 kV+自动mA(NI=12),DR=40%,ASIR40%重建;C组:100 kV+自动mA(NI=13),DR=40%,ASIR40%重建。比较三组动脉期的辐射剂量、客观图像质量(感兴趣区CT值、信噪比、对比噪声比)以及主观图像质量,主观图像质量由两名放射科医师采用双盲法阅片进行评价。辐射剂量及客观图像质量评价指标行方差分析,主观图像质量比较行非参数秩和检验,医师对图像诊断一致性检验行Kappa分析。结果 C组肺动脉及胸主动脉CT值[(298.55±87.12)HU,(357.34±44.94)HU]均高于A组[(250.84±68.60)HU,(266.34±34.20)HU]和B组[(233.51±60.63)HU,(270.81±42.39)HU](P<0.05),C组胸主动脉感兴趣区信噪比及对比噪声比(50.42±10.91,41.69±9.70)高于A组(43.26±8.45,33.11±7.39)和B组(43.55±9.26,33.52±8.34)(P<0.05),三组主观图像质量差异无统计学意义(P>0.05,Kappa值=0.613),辐射剂量(DLP)C组[(98.96±29.16)mG y/cm]与B组[(126.24±37.12)mG y/cm]较A组[(240.41±77.81)mG y/cm]分别降低约48.5%与58.9%(P<0.05)。结论在保证图像质量前提下,应用DR技术可以降低一定的辐射剂量,基于ASiR的DR技术结合低管电压(100 kV)技术能够进一步降低胸部增强CT辐射剂量。 展开更多
关键词 低剂量 胸部增强 体层摄影术 X线计算机 低管电压
原文传递
L-LWiDose^4技术在新生儿先天性心脏病CT血管成像中的临床应用 被引量:6
13
作者 徐雷 陈博 +2 位作者 陈廷港 吴爱琴 程建敏 《温州医科大学学报》 CAS 2019年第3期189-193,共5页
目的:探讨低X线辐射剂量及低碘浓度等渗对比剂联合iDose^4迭代重建技术(L-LWiDose^4)在新生儿先天性心脏病CT血管成像(CTA)中的可行性。方法:前瞻性收集2015年1月至2018年3月温州医科大学附属第二医院育英儿童医院新生儿科需行心脏CTA... 目的:探讨低X线辐射剂量及低碘浓度等渗对比剂联合iDose^4迭代重建技术(L-LWiDose^4)在新生儿先天性心脏病CT血管成像(CTA)中的可行性。方法:前瞻性收集2015年1月至2018年3月温州医科大学附属第二医院育英儿童医院新生儿科需行心脏CTA检查的连续102例患者,随机分为2组,采用不同的扫描方案:常规组(A组)53例,采用100 kVp、100 mAs、碘海醇(350 mg I/mL),重建方式为滤波反投影(FBP)算法;实验组49例,采用80 kVp、80 mAs、碘克沙醇(270 mg I/mL),根据iDose^4迭代算法可以得到i Dose4-1~i Dose4-7 7组图像,选取iDose^4-2~i Dose^4-6 5组图像,分别记为B组、C组、D组、E组、F组。依据新生儿体质量采取不同的对比剂注射剂量并计算碘摄入量。测量主动脉弓、气管分叉水平降主动脉、肺动脉干及主动脉弓层面两侧胸大肌和竖脊肌CT值,测量气管分叉层面周围空气CT值的标准差(SD),记为背景噪声,计算信噪比(SNR)和对比噪声比(CNR),并对图像质量进行主观评价。记录容积CT剂量指数(CTDIvol) 和剂量长度乘积(DLP),并计算有效剂量(ED)和体型特异性剂量评估(SSDE)。以手术或心导管造影为"金标准",统计并比较各组CTA检查的诊断符合率。结果:实验组CTDIvol、SSDE、DLP、ED较常规组分别降低了57.08%、56.62%、58.31%、56.97%(P<0.05)。常规组、实验组对比剂碘摄入量分别为(1.83±1.27)g和(1.61±1.36)g,差异有统计学意义(P<0.05)。B组、F组图像客观评价不及A组、C组、D组、E组(P<0.05)。A组、D组、E组图像主观评价差异无统计学意义。常规组、实验各组诊断符合率分别为98.6%、81.6%、87.7%、97.9%、97.9%、96.9%,差异无统计学意义(P>0.05)。结论:80 kVp、80 mAs、碘克沙醇(270 mg I/mL)联合iDose^4迭代重建技术新生儿先天性心脏病CTA检查,在降低患者的电离辐射剂量和对比剂碘剂量的同时,其图像质量能够满足临床诊断需要。 展开更多
关键词 辐射剂量 非离子型碘对比剂 先天性心脏病 迭代重建 体层摄影术 X线计算机
暂未订购
单次注射对比剂在CTP联合头颈CTA卒中检查中的应用 被引量:1
14
作者 李彭 胡永胜 +3 位作者 何新华 刘玲 张梦琦 夏春华 《中国CT和MRI杂志》 2025年第6期20-23,共4页
目的探讨使用小剂量测试法在头颈CT血管造影(CTA)联合头颅灌注(CTP)扫描模式的应用。方法选取2023年4月至2023年12月在我院行头颈CTA及CTP的患者86例,随机分为对照组(A组)和实验组(B组),每组各43例。对照组采用常规扫描,使用两次对比剂... 目的探讨使用小剂量测试法在头颈CT血管造影(CTA)联合头颅灌注(CTP)扫描模式的应用。方法选取2023年4月至2023年12月在我院行头颈CTA及CTP的患者86例,随机分为对照组(A组)和实验组(B组),每组各43例。对照组采用常规扫描,使用两次对比剂,分别行CTA和CTP扫描;实验组采用testbolus法,CTP扫描期间,当ROI达到峰值,立即行CTA扫描,后继续CTP扫描。记录两组患者的辐射剂量、对比剂剂量;测量和计算两组图像的CT值、噪声值(SD)、信噪比(SNR)、对比噪声比(CNR);对两组图像进行主观评分。做Bland-Altman图进行CT和MRI之间的一致性分析。结果实验组(65mL)比对照组(90mL)对比剂用量减少约28%,有效辐射剂量显著减少(4.40±0.03vs.6.89±0.08)。两组数据的CT值、SNR、CNR值及主观评分无显著差异。与MRI相比,测定的脑梗区域和个数具有一致性。结论单次使用对比剂,单次扫描可以降低对比剂用量和辐射剂量。 展开更多
关键词 头颈CTA 头颅灌注 脑梗区域和个数 小剂量测试 对比剂和辐射剂量
暂未订购
低管电压、低对比剂用量及浓度联合快速迭代重建技术(iDose)在头颈CTA中的应用 被引量:2
15
作者 郭文强 《辽东学院学报(自然科学版)》 CAS 2018年第4期253-258,共6页
60例头颈部CTA受检者随机等分为双低组和对照组。双低组采用100 kV的管电压、浓度为270 mgI/mL的对比剂50 mL联合应用快速迭代重建算法,对照组采用120 kV的管电压、浓度为370mgI/mL的对比剂50 mL。比较两组头颈部血管内CT值、噪声(SD)、... 60例头颈部CTA受检者随机等分为双低组和对照组。双低组采用100 kV的管电压、浓度为270 mgI/mL的对比剂50 mL联合应用快速迭代重建算法,对照组采用120 kV的管电压、浓度为370mgI/mL的对比剂50 mL。比较两组头颈部血管内CT值、噪声(SD)、CNR、SNR、图像质量评分、CTDIvol、DLP,评价其图像质量及辐射剂量。结果显示,双低组颈部血管CT值略低于对照组,颅内血管CT值略高于对照组;两组图像质量均满足临床诊断需要;双低组联合快速迭代重建技术(iDose),噪声(SD)较对照组减低,SNR、CNR较对照组增高;双低组辐射剂量较对照组明显降低,CTDIvol、DLP分别降低约51%、56%。因此,低管电压、低对比剂剂量及浓度联合应用快速迭代重建技术(iDose)进行头颈部CTA检查是可行的,图像质量能完全满足临床诊断需要,而且辐射剂量明显降低。 展开更多
关键词 低管电压 对比剂 快速迭代重建技术 辐射剂量
暂未订购
高级别深度学习图像重建算法在低管电压、低对比剂用量冠状动脉CT血管成像中的应用研究
16
作者 张泽华 王建明 唐笑先 《中西医结合心脑血管病杂志》 2025年第14期2201-2205,共5页
目的:评价高级别深度学习图像重建(DLIR-H)算法在低辐射剂量和低对比剂用量的冠状动脉CT血管成像(CCTA)中的可行性。方法:前瞻性纳入180例行CCTA的病人,随机分为“双低”组(A组)和对照组(B组),各90例。根据体质指数将两组病人分别分为3... 目的:评价高级别深度学习图像重建(DLIR-H)算法在低辐射剂量和低对比剂用量的冠状动脉CT血管成像(CCTA)中的可行性。方法:前瞻性纳入180例行CCTA的病人,随机分为“双低”组(A组)和对照组(B组),各90例。根据体质指数将两组病人分别分为3个亚组(A1组、A2组、A3组和B1组、B2组、B3组),每个亚组30例。A组采用DLIR-H算法进行图像重建;B组采用传统100~120 kV进行CCTA扫描,均采用60%自适应统计迭代重建(ASIR-V)算法进行图像重建。对两组相同体质指数亚组图像质量进行主观评分和客观评价。图像质量主观评分采用5分法;采用图像噪声、信噪比(SNR)和对比噪声比(CNR)对图像质量进行评估。结果:两组图像质量主观评分均满足诊断要求。A组图像质量的主观评分均高于B组,差异有统计学意义(P<0.001)。A1组、A2组、A3组不同冠状动脉节段SNR、CNR均高于B1组、B2组、B3组,A1组、A2组、A3组CT值、噪声均低于B1组、B2组、B3组,差异均有统计学意义(P<0.001);且A1组、A2组、A3组有效辐射剂量及对比剂用量均低于B1组、B2组、B3组,差异均有统计学意义(P<0.001)。结论:在不同体质指数病人中,低管电压、低对比剂用量扫描联合DLIR-H算法较常规扫描联合60%ASIR-V算法,提高了低管电压CCTA所得图像质量,且病人所接受的辐射剂量与对比剂总量均明显减少。 展开更多
关键词 冠状动脉疾病 计算机断层成像 冠状动脉CT血管成像 辐射剂量 对比剂 深度学习图像重建
暂未订购
低剂量对比剂肺动脉CTA成像诊断肺动脉栓塞的图像质量分析
17
作者 张广智 黄婷婷 《四川生理科学杂志》 2025年第3期479-482,共4页
目的:分析低剂量对比剂肺动脉CT血管造影(CT angiography,CTA)诊断肺动脉栓塞的图像质量。方法:回顾性选取本院2021年1月至2023年6月收治的肺动脉栓塞患者68例,均进行肺动脉CTA成像检查,以不同对比剂量为分组原则,分为A组(35例,常规剂量... 目的:分析低剂量对比剂肺动脉CT血管造影(CT angiography,CTA)诊断肺动脉栓塞的图像质量。方法:回顾性选取本院2021年1月至2023年6月收治的肺动脉栓塞患者68例,均进行肺动脉CTA成像检查,以不同对比剂量为分组原则,分为A组(35例,常规剂量)、B组(33例,低剂量)。比较两组血管强化情况、肺动脉CT值、信噪比(Signal-to-Noise Ratio,SNR)、对比噪声比(Carrier to Noise Ratio,CNR)、背景噪声、上腔静脉评分、图像质量主观评分、辐射剂量。结果:两组左肺静脉、右肺静脉CT值、肺动脉CT值、SNR、CNR、实际容积CT剂量指数(Computed Tomography Dose Index,CTD_(Ivol))、扫描长度与剂量长度之积(Dose Length Product,DLP)、有效剂量(Effective Dose,ED)比较,B组均较低;两组背景噪声、上腔静脉评分比较,B组均更高,统计学差异显著(P<0.05)。结论:低剂量对比剂肺动脉CTA成像可减少对比剂使用量及辐射剂量,有效区分肺静脉、肺动脉影像,且图像质量较好。 展开更多
关键词 低剂量 对比剂 肺动脉栓塞 CT血管造影
暂未订购
CT造影检查中不同造影剂浓度及辐射剂量方案诊断泌尿系统疾病的效果分析
18
作者 李伟频 吴琮宁 李博峰 《微创医学》 2025年第1期58-61,共4页
目的分析CT造影检查中不同造影剂浓度及剂量方案诊断泌尿系统疾病的临床效果。方法选取2020年1月至2021年1月期间在南宁市红十字会医院行CT尿路造影检查的90例患者作为研究对象,其中接受常规浓度、常规剂量CT造影检查的45例患者设为对照... 目的分析CT造影检查中不同造影剂浓度及剂量方案诊断泌尿系统疾病的临床效果。方法选取2020年1月至2021年1月期间在南宁市红十字会医院行CT尿路造影检查的90例患者作为研究对象,其中接受常规浓度、常规剂量CT造影检查的45例患者设为对照组,同期接受优化浓度与剂量方案CT造影检查,且一般资料与对照组均衡可比的45例患者设为观察组。对比两组患者的造影图像效果以及双肾、输尿管和膀胱的对比度噪声比(CNR),血肌酐水平等指标的差异。结果两组患者的造影图像效果比较,差异无统计学意义(P>0.05)。两组患者双肾、输尿管层面的CNR比较,差异均无统计学意义(均P>0.05);观察组患者膀胱层面的CNR高于对照组,差异有统计学意义(P<0.05)。观察组造影剂用量为(44.00±3.81)mL,对照组造影剂用量为(66.03±3.51)mL,组间差异有统计学意义(P<0.05)。造影前,两组患者的血肌酐水平比较,差异无统计学意义(P>0.05);造影后,两组患者的血肌酐水平均有所提高,但观察组血肌酐水平低于对照组,差异有统计学意义(P<0.05)。观察组造影后发生急性肾功能损伤2例(4.44%),对照组造影后发生急性肾功能损伤10例(22.22%),组间差异有统计学意义(P<0.05)。结论小剂量、低浓度造影剂能够获得与传统浓度剂量方案相当的图像质量,且具有安全性更高的优势,可有效降低急性肾功能损伤的发生率,值得临床应用推广。 展开更多
关键词 尿路造影术 CT造影 辐射剂量 造影剂 浓度 泌尿系疾病 诊断
暂未订购
双低剂量CTP-CTA对前循环大血管闭塞性急性缺血性卒中患者脑损伤程度的评估价值
19
作者 周瑞臣 王龙 +2 位作者 张剑锋 李静 周蕊 《医学影像学杂志》 2025年第6期10-15,共6页
目的探讨双低剂量CT灌注成像(CTP)-CT血管成像(CTA)对前循环大血管闭塞性急性缺血性卒中(LVO-AIS)患者脑损伤程度的评估价值。方法选取前循环LVO-AIS患者116例,根据神经缺损程度量表(NIHSS)评分分为轻度组(NIHSS评分0~4分,43例)、中度组... 目的探讨双低剂量CT灌注成像(CTP)-CT血管成像(CTA)对前循环大血管闭塞性急性缺血性卒中(LVO-AIS)患者脑损伤程度的评估价值。方法选取前循环LVO-AIS患者116例,根据神经缺损程度量表(NIHSS)评分分为轻度组(NIHSS评分0~4分,43例)、中度组(NIHSS评分5~20分,52例)、重度组(NIHSS评分>20分,21例)。所有观察对象于入院当日接受低辐射剂量和低对比剂摄入量CTP、CTA检查。通过伪彩色处理区别并突出病变区与正常组织的对比度,将病变区分为病灶中心区域(病灶中心区)、病灶周围区域(病灶周围区)、介于病灶中心与病灶周围的区域(病灶平均区)以及病变区域对应的正常区域(对侧相应区)。比较三组双低剂量CTP-CTA扫描参数,包括脑血流量(CBF)、峰始时间(TS)、达峰时间(TTP)、脑血容量(CBV)及Maas评分。采用Spearman相关系数法分析双低剂量CTP-CTA扫描参数与前循环LVO-AIS患者脑损伤程度的关系。比较病灶中心区与病灶周围区、病灶平均区与对侧相应区双低剂量CTP-CTA扫描参数。绘制受试者工作特征(ROC)曲线分析双低剂量CTP-CTA对前循环LVO-AIS患者中重度脑损伤的评估价值。结果轻度组CBF、CBV高于中度组和重度组,且中度组高于重度组(P均<0.05);轻度组TS、TTP低于中度组和重度组,且中度组低于重度组(P均<0.05)。轻度组Maas评分≤2分占比低于中度组、重度组,且中度组低于重度组(P均<0.05)。双低剂量CTP-CTA扫描参数CBF、CBV与前循环LVO-AIS患者脑损伤程度呈负相关(r分别为-0.587、-0.582,P均<0.05),TS、TTP、Maas评分与前循环LVO-AIS患者脑损伤程度呈正相关(r分别为0.614、0.610、0.603,P均<0.05)。病灶中心区CBF、CBV低于病灶周围区,TS、TTP高于病灶周围区(P均<0.05);病灶平均区CBF、CBV低于对侧相应区,TS、TTP高于对侧相应区(P均<0.05)。双低剂量CTP-CTA扫描参数联合评估前循环LVO-AIS患者中重度脑损伤的曲线下面积(AUC)高于双低剂量CTP-CTA扫描参数单独评估前循环LVO-AIS患者中重度脑损伤的AUC(Z分别为2.152、2.397、2.186、2.513、2.221、2.739,P均<0.05)。结论双低剂量CTP-CTA扫描参数能够区分前循环LVO-AIS患者病灶区域,对其中重度脑损伤具有较高的评估价值。 展开更多
关键词 体层摄影术 X线计算机 前循环大血管闭塞性急性缺血性卒中 辐射剂量 对比剂摄入量 脑损伤程度
暂未订购
头颈部CTA中GSI扫描联合“双低”技术在中老年人群体的应用价值
20
作者 张晓龙 赵英明 +2 位作者 张国祥 魏方生 陈呈 《CT理论与应用研究(中英文)》 2025年第2期295-302,共8页
目的:探讨头颈部CTA中GSI扫描联合“双低”技术在中老年人群体的应用价值。材料和方法:回顾性收集2023年2月至12月行头颈CTA检查患者的影像资料150例,根据不同的扫描方式分为A、B和C 3组,各50例。A组和B组均为常规螺旋扫描,管电压分别为... 目的:探讨头颈部CTA中GSI扫描联合“双低”技术在中老年人群体的应用价值。材料和方法:回顾性收集2023年2月至12月行头颈CTA检查患者的影像资料150例,根据不同的扫描方式分为A、B和C 3组,各50例。A组和B组均为常规螺旋扫描,管电压分别为120 kV和100 kV,均为管电流自动调制300~500 mA,对比剂用量及流速均为固定55 mL和4.5 mL/s,盐水以与对比剂相同用量及流速进行注射。C组能谱扫描,平扫组管电压为80 kV,增强组管电压为80~140 kV瞬时切换,管电流均为恒定的320 mA,采用个性化对比剂注射方案。对3组影像资料进行主观评价、客观评价及比较对比剂用量、平均注射速率。结果:B组头颈部各血管平均CT值大于A组和C组,差异具有统计学意义;主动脉弓层面,B组SNR及CNR参数优于A组和C组,差异具有统计学意义;其余血管层面C组SNR、CNR、SD参数均优于A组和B组,除颈总动脉层面,差异具有统计学意义;C组DLP相较于A组和B组分别降低53.9%和27.6%,对比剂用量降低27.2%。C组对比剂平均注射速率为(3.9±0.5)mL/s低于A组和B组固定流速4.5 mL/s。结论:在中老年人群体中,以GSI扫描模式联合“双低”技术行头颈CTA可有效降低辐射剂量、减少对比剂用量及改善图像质量。 展开更多
关键词 CT血管造影术 能谱单能量 辐射剂量 对比剂
原文传递
上一页 1 2 23 下一页 到第
使用帮助 返回顶部