期刊文献+
共找到3,949篇文章
< 1 2 198 >
每页显示 20 50 100
Power Efficient Battery Charger by Using Constant Current/Constant Voltage Controller
1
作者 Falah Al Hassan 《Circuits and Systems》 2012年第2期180-186,共7页
The Battery Charger Specification presents solution for rechargeable batteries used in portable electronic equipment such as laptop computer systems, cellular telephones and video cameras and the demands for low cost ... The Battery Charger Specification presents solution for rechargeable batteries used in portable electronic equipment such as laptop computer systems, cellular telephones and video cameras and the demands for low cost battery chargers are rising these days without give attention for the performance. The goal of the paper was combining high efficiency and versatility with low-cost design and this paper includes the design of the snubber cell, and the components of the current/voltage control charge method. This charger applies a relatively constant current and constant voltage to the battery indefinitely regardless of the AC input rang voltage all the equations described in this paper. The design of prototype converter is verified through an experimental result. 展开更多
关键词 BATTERY CHARGER FLYBACK constant Currant constant voltage Snubber Efficiency
在线阅读 下载PDF
Development of a Buck Converter for Efficient Energy Storage Integration Using Constant Voltage(CV)Methods
2
作者 Ricky Alfian Dita Sudirman Palaloi +6 位作者 Rezi Delfianti Catur Harsito Muhammad Nevandra Fithra Pangestu Deo Ferdi Ramadhan Tovva Firdansyah Amijaya Farhan Mudzaffar Dimas Raka Buana Putra 《Energy Engineering》 2025年第6期2355-2370,共16页
Efficient battery charging requires a power conversion system capable of providing precise voltage regulation tailored to the battery’s needs.This study develops a buck converter with a 36 V input for charging a 14 V... Efficient battery charging requires a power conversion system capable of providing precise voltage regulation tailored to the battery’s needs.This study develops a buck converter with a 36 V input for charging a 14 V battery using the Constant Voltage(CV)method.The system is designed to ensure safe and efficient charging while protecting the battery from overcharging and extending its lifespan.In the proposed design,the converter maintains a constant output voltage while the charging current decreases as the battery approaches full capacity.Pulse Width Modulation(PWM)is used as a control strategy to modify the duty cycle of the converter.This keeps the voltage output stable whenever the load changes.The design process involves simulation and experimental validation to evaluate the system’s performance and efficiency.The test results show the significant impact of Proportional-Integral-Derivative(PID)control on the stability of the output voltage to meet the requirements for 14 V battery charging and the efficiency of the battery charging process.The output voltage becomes more stable,with reduced oscillation and minimal steadystate error.The State of Charge(SOC)increases more stably,controllably,and efficiently thanks to the PID controller’s ability to adjust the duty cycle in real time based on system feedback.This dynamic adjustment ensures that the output current and voltage remain within the optimal range,which directly improves the battery charging process.In addition,PID control significantly improves the dynamic response of the system,reducing overshoot and settling time while maintaining precise voltage regulation.This speeds up the battery charging process and contributes to better energy efficiency,reduced power loss,and extended battery life.This research provides a reliable and cost-effective solution for applications in electric vehicles,renewable energy systems,and other battery-powered devices. 展开更多
关键词 Battery charging buck converter constant voltage energy storage system
在线阅读 下载PDF
Chip Design of Li-Ion Battery Charger Operating in Constant-Current/Constant-Voltage Modes 被引量:8
3
作者 陈琛 何乐年 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2007年第7期1030-1035,共6页
A design for a Li-ion battery charger IC that can operate in a constant current-constant voltage (CC- CV) charge mode is proposed. In the CC-CV charge mode,the charger IC provides a constant charging current at the ... A design for a Li-ion battery charger IC that can operate in a constant current-constant voltage (CC- CV) charge mode is proposed. In the CC-CV charge mode,the charger IC provides a constant charging current at the beginning, and then the charging current begins to decrease before the battery voltage reaches its final value. After the battery voltage reaches its final value and remains constant,the charging current is further reduced. This approach prevents charging the battery with full current near its saturated voltage,which can cause heating. The novel design of the core of the charger IC realizes the proposed CC-CV charge mode. The chip was implemented in a CSMC 0.6μm CMOS mixed signal process. The experimental results verify the realization of the proposed CC- CV charge mode. The voltage of the battery after charging is 4. 1833V. 展开更多
关键词 Li-ion battery charger constant current-constant voltage charge modes CMOS analog circuit
在线阅读 下载PDF
Low voltage substrate current: a monitor for interface states generation in ultra-thin oxide n-MOSFETs under constant voltage stresses
4
作者 王彦刚 许铭真 谭长华 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第11期3502-3506,共5页
The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is f... The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is found that the low voltage Ib is formed by electrons tunnelling through interface states, and the variations of Ib(△Ib) are proportional to variations of Nit (△Nit). The Nit energy distributions were determined by differentiating Nit(Vg). The results have been compared with that measured by using gate diode technique. 展开更多
关键词 interface states substrate current ultra-thin oxide constant voltage stress
原文传递
Multi-stage constant current charging strategy considering SOC intervals and voltage thresholds
5
作者 Yu Zhang Si Xu Tiezhou Wu 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期143-153,共11页
Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,w... Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,while shortening the charging time.This in turn affects the safety of the charging process.Furthermore,the higher charging currents are not ideal for shortening the charging time in the later stages of charging.To solve the aforementioned problems,in this study,a multi-stage constant current charging strategy is presented.This strategy can shorten the battery charging time by using the increase in battery temperature during the charging process as a constraint,using a genetic algorithm to calculate the charging current value,and investigating the phased approach to charging.Finally,the charging strategy is experimentally validated at different ambient temperatures and different initial SOCs.The experimental results show that the charging strategy proposed in this paper not only reduces the amount of calculations,but also reduces the temperature rise by up to 46.4%and charging time by up to 4.2%under different operating conditions. 展开更多
关键词 Charging time Battery temperature rise Genetic algorithm Multi-stage constant current charging
在线阅读 下载PDF
Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load
6
作者 Said Oucheriah Abul Azad 《Circuits and Systems》 2024年第3期29-43,共15页
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ... The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations. 展开更多
关键词 Boost Converter Robust Sliding Mode Control constant Power Load (CPL) current-Sensorless Control Extended State Observer
在线阅读 下载PDF
Linear fast shutdown technology based on self-resonant constant voltage clamping 被引量:1
7
作者 SUN De-li SONG Shuang TENG Fei 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2020年第3期297-306,共10页
Transient electromagnetic method(TEM)has been widely used in the field of medium and shallow underground detection due to its high detection efficiency and large detection depth.However,due to the long turn-off time o... Transient electromagnetic method(TEM)has been widely used in the field of medium and shallow underground detection due to its high detection efficiency and large detection depth.However,due to the long turn-off time of the transmitting current caused by the inductive characteristics of the transmitting coil,the early signals will be overwhelmed by primary field.Since the early signals contain most of shallow geological signals,it is necessary to reduce the long turn-off time to get shallow layer signal.Due to lack of a reliable and effective clamping method for high-power transmission at present,we design a TEM transmitter fast turn-off circuit,combining self-resonant zero-voltage switching technology with the corresponding timing control circuit to solve this problem effectively.A transient electromagnetic transmitter based on self-resonant constant voltage clamping technology was fabricated to charge the clamping capacitor.The rated transmitting current of the transmitter is 20 A,and the turn-off time is continuously adjustable from 550-50μs.Moreover,the current drop process is approximately linear rather than exponential attenuation.Compared with the existing clamping methods,the proposed clamping method solves the problems that transient voltage suppressor(TVS)clamping cannot be used in high-power occasions and has a high failure rate.It also solves the problem of long pre-charge time in traditional capacitor clamping methods due to insufficient inductance of the small size transmitting coil.The proposed method can provide a reference for fast shutdown of large current. 展开更多
关键词 transient electromagnetic method(TEM) constant voltage clamp zero voltage switch(ZVS) linear turn-off
在线阅读 下载PDF
Centralized Solar PV Systems for Static Loads Using Constant Voltage Control Method
8
作者 S. Alagammal N. Rathina Prabha I. Aarthy 《Circuits and Systems》 2016年第13期4213-4226,共14页
The alternative energy resources, like solar, are always complementary due to environmental changes. Energy generation with the sources such as solar and wind is gaining importance and of that photovoltaic conversion ... The alternative energy resources, like solar, are always complementary due to environmental changes. Energy generation with the sources such as solar and wind is gaining importance and of that photovoltaic conversion is the main focus of researches due to its promising potential as the electrical source. This paper presents the constant voltage method of control where the output of the converter is maintained constant irrespective of the variations in the irradiance with the high step-up isolated efficient single switch DC-DC converter for the solar PV systems. Constant voltage method of control uses the array of photovoltaic systems as its energy source. The output of the Solar PV systems is nonlinear and has its dependency on temperature and irradiance by which the panel voltage and current varies with the variation in irradiance. Constant voltage control method always operates in such a way that the converter voltage is tried to be maintained constantly to the reference voltage which is set by the user. The system used here utilizes high step single switch isolated DC-DC converter and monitors the voltage continuously by varying the duty cycle to maintain the converter voltage always constant. As a way of improving the performance, both the open and closed loop analysis is done where the closed loop analysis uses the PI controller for its performance. The model is implemented in MATLAB and it accepts the irradiance as the input and outputs the constant voltage from the converter and the feasibility of the proposed converter topology is confirmed with experimental results of the prototype model. 展开更多
关键词 Photovoltaic System Centralized System constant voltage Control Method Proportional-Integral Controller
在线阅读 下载PDF
DC microgrid stability control with constant power load:a review 被引量:1
9
作者 LI Xin ZOU Junnan LIU Jinhui 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2024年第4期532-546,共15页
The DC microgrid has the advantages of high energy conversion efficiency,high energy transmission density,no reactive power flow,and grid-connected synchronization.It is an essential component of the future intelligen... The DC microgrid has the advantages of high energy conversion efficiency,high energy transmission density,no reactive power flow,and grid-connected synchronization.It is an essential component of the future intelligent power distribution system.Constant power load(CPL)will degrade the stability of the DC microgrid and cause system voltage oscillation due to its negative resistance characteristics.As a result,the stability of DC microgrids with CPL has become a problem.At present,the research on the stability of DC microgrid is mainly focused on unipolar DC microgrid,while the research on bipolar DC microgrid lacks systematic discussion.The stability of DC microgrid using CPL was studied first,and then the current stability criteria of DC microgrid were summarized,and its research trend was analyzed.On this basis,aiming at the stability problem caused by CPL,the existing control methods were summarized from the perspective of source converter output impedance and load converter input impedance,and the current control methods were outlined as active and passive control methods.Lastly,the research path of bipolar DC microgrid stability with CPL was prospected. 展开更多
关键词 constant power load(CPL) DC microgrid voltage balancer stability criterion cascaded system virtual resistance
在线阅读 下载PDF
Dynamics and stabilization of peak current-mode controlled buck converter with constant current load 被引量:3
10
作者 冷敏瑞 周国华 +1 位作者 张凯暾 李振华 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期101-109,共9页
The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on th... The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. 展开更多
关键词 buck converter constant current load discrete iterative map model ramp compensation
原文传递
Field-induced phase transitions in chiral smectic liquid crystals studied by the constant current method
11
作者 H Dhaouadi R Zgueb +2 位作者 O Riahi F Trabelsi T Othman 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期373-379,共7页
In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied pr... In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied product can be obtained.In this work, we make a slight modification to the measurement principles based on this method. This modification allows the characteristic parameters of ferroelectric liquid crystal to be quantitatively measured. The use of a current square signal highlights a phenomenon of ferroelectric hysteresis with remnant polarization at null field, which points out an effect of memory in this compound. 展开更多
关键词 chiral smectic liquid crystal constant current method ferroelectric polarization dielectric permittivity
原文传递
Circulating current suppression for ground tied variable frequency to constant frequency converter system in aircraft
12
作者 Wei WEI Ming HUANG +2 位作者 Wenli YAO Weilin LI Xiaobin ZHANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第11期386-397,共12页
This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400... This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400 Hz load in an aircraft with a variable frequency power supply.Due to the requirement of aircraft standards,both grounds of the rectification and inversion stage are tied to the metal frame of the aircraft.With such a tied ground,the DC bus voltage rises greatly,and a large circulating current appears in the casing as the ground,which leads to equipment failure and potential safety hazards.According to the existing methods of circulating current fault suppression,this paper analyzes the causes of the above faults and the harmonic components of circulating current and points out the limitations of the existing methods.Therefore,a Common-Mode(CM)choke-based method is proposed to provide a high impedance in the path of the CM circulating current.By doing so,the circulating current can be suppressed without the additional burden of the hardware and control algorithm,which is quite friendly for quality control of mass-production aircraft.Moreover,a simplified mathematic model of the VFCF converter system is derived to calculate the minimum inductance value reference of the CM choke,which saves the weight of passive devices to the greatest extent.Finally,simulation and experimental results are studied to verify the effectiveness of the proposed method. 展开更多
关键词 Aircraft power supply Circulating current Common mode choke Power supply circuits Variable Speed constant Frequency
原文传递
Numerical Solution of MHD Convection and Mass Transfer Flow of Viscous Incompressible Fluid about an Inclined Plate with Hall Current and Constant Heat Flux
13
作者 Mohammad Wahiduzzaman Runu Biswas +2 位作者 Md. Eaqub Ali Md. Shakhaoath Khan Ifsana Karim 《Journal of Applied Mathematics and Physics》 2015年第12期1688-1709,共22页
The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifest... The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifestation of transverse magnetic field near an inclined vertical permeable flat plate. It is assumed that the induced magnetic field is negligible compared with the imposed magnetic field. The governing boundary layer equations have been transferred into non-similar model by implementing similarity approaches. The physical dimensionless parameter has been set up into the model as Prandtl number, Eckert number, Magnetic parameter, Schmidt number, local Grashof number and local modified Grashof number. The numerical method of Nactsheim-Swigert shooting iteration technique together with Runge-Kutta six order iteration scheme has been used to solve the system of governing non-similar equations. The physical effects of the various parameters on dimensionless primary velocity profile, secondary velocity profile, and temperature and concentration profile are discussed graphically. Moreover, the local skin friction coefficient, the local Nusselt number and Sherwood number are shown in tabular form for various values of the parameters. 展开更多
关键词 MHD HEAT and Mass Transfer HALL current Inclined Plate constant HEAT FLUX
在线阅读 下载PDF
Non-inverting buck-boost DC-DC converter based on constant inductor current control
14
作者 Yao Suyi Jiang Jianguo 《Journal of Southeast University(English Edition)》 EI CAS 2021年第2期171-176,共6页
The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the ... The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the dependence on the external components and device variation and make smooth transition between hysteresis control loop and pulse width modulation(PWM)control loop.The small signal model was deduced for the buck and boost operation mode.The inductor current slope control(ICSC)was proposed to implement the automatic mode transition between buck and boost mode in one switching cycle.The results show that the converter prototype has good dynamic response capability,achieving 94%efficiency and 95%peak efficiency at full 10 A load current. 展开更多
关键词 four switch buck-boost converter inductor current slope control constant inductor current control small signal model
在线阅读 下载PDF
An improved analysis method of constant-current charge/discharge curves and its application to nickel hydroxide electrode
15
作者 潘滔 王建明 +3 位作者 陈惠 赵彦琳 肖慧明 张鉴清 《中国有色金属学会会刊:英文版》 CSCD 2003年第2期462-466,共5页
The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/disch... The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/discharge rates and intermittent discharge experiment are discussed. Though the d t /d E ? 獷 plot is affected by many factors, it clearly has intrinsic relation with the nature of active material such as conductivity and thermodynamic potential of active material, which changes with the state of charge. The d t /d E—E plot can also be applied to other electrochemical active materials, especially to those having several phases during charge or discharge. 展开更多
关键词 镍氢电池 电极 分析方法 改进 放电曲线
在线阅读 下载PDF
An Adaptive Response Compensation Technique for the Constant-Current Hot-Wire Anemometer
16
作者 Soe Minn Khine Tomoya Houra Masato Tagawa 《Open Journal of Fluid Dynamics》 2013年第2期95-108,共14页
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we... An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its effectiveness experimentally for hot-wires of 5 μm, 10 μm and 20 μm in diameter. Then, another novel technique based on a two-sensor probe technique—originally developed for the response compensation of fine-wire thermocouples (Tagawa and Ohta 1997;Tagawa et al. 1998)—has been proposed for estimating thermal time-constants of hot-wires to realize the in-situ response compensation of the CCA. To demonstrate the usefulness of the CCA, we have applied the response compensation schemes to multipoint velocity measure- ment of a turbulent wake flow formed behind a circular cylinder by using a CCA probe consisting of 16 hot-wires, which were driven simultaneously by a very simple constant-current circuit. As a result, the proposed response compensation techniques for the CCA work quite successfully and are capable of improving the response speed of the CCA to obtain reliable measurements comparable to those by the commercially-available constant-temperature hot-wire anemometer (CTA). 展开更多
关键词 Flow Measurement HOT-WIRE ANEMOMETER Turbulent Flow constant-current HOT-WIRE ANEMOMETER Response COMPENSATION Frequency Response Time-constant Multipoint Measurement Digital Signal Processing
暂未订购
Constant Ripple Current Control for Switching DC-DC Converter
17
作者 Gwo-Tarng Chern Jenn-Jong Shieh 《Journal of Energy and Power Engineering》 2012年第9期1437-1441,共5页
The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microele... The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microelectronic load applications. This paper proposes a DC-DC converter using variable on-time and variable switching frequency control enhanced constant ripple current control and reduced magnetic components. The proposed converter is realized by making the turn-offtime proportional to the on-time of the converter, according to the input and output voltage, thereby reducing the corresponding current ripple on output voltage in the continuous conduction mode. A Buck DC-DC converter using the proposed control strategy is analyzed in detail, along with some experimental results to show the performance and effectiveness of this converter. 展开更多
关键词 constant ripple current DC-DC converter variable switching frequency continuous conduction mode indirect currentsensor magnetic component.
在线阅读 下载PDF
Power optimization of photovoltaic modules under varying environmental conditions based on current equalization collaborating with constant voltage control
18
作者 DaiBin Tang Fei Lu Siaw Tzer Hwai Gilbert Thio 《Clean Energy》 EI CSCD 2024年第4期169-182,共14页
The performance of photovoltaic(PV)modules is affected by environmental factors such as irradiance and temperature,which can lead to a decrease in output performance or even damage.This study proposes an improved form... The performance of photovoltaic(PV)modules is affected by environmental factors such as irradiance and temperature,which can lead to a decrease in output performance or even damage.This study proposes an improved formula for calculating the real maximum power of PV modules by analysing the influence of irradiance and temperature.A simulation model is developed using PLECS software to simulate the global maximum power of PV modules under different environmental conditions and the results are compared with the calculated real maximum power.A power optimization scheme for PV modules is then proposed based on current equalization and constant voltage control.This scheme employs a single-switch multi-winding forward-flyback converter to equalize the mismatched currents between cell strings,thereby enhancing the output performance.Traditional proportional-integral controllers are utilized to achieve constant voltage control and obtain the real maximum power of PV modules.Simulation models are built in the PLECS simulation platform to evaluate the performance of a global maximum power point tracking scheme based on the traditional perturb-and-observe(TPO)algorithm with current equalization,a segment perturb-and-observe algorithm without current equalization,and the proposed power optimization scheme.The simulation results demonstrate that the proposed constant voltage control has greater efficiency than the TPO algorithm.The proposed scheme achieves a significant improvement in efficiency,with a 27.87%increase compared with the segment perturb-and-observe algorithm without current equalization. 展开更多
关键词 current equalization constant voltage control forward-flyback converter PV modules perturb-and-observe(P&O)algorithm
原文传递
Electrochemical-thermal-mechanical coupling model considering lithium plating for multi-stage constant current fast charging of lithium-ion batteries
19
作者 Yuguang Li Yudong Shen +2 位作者 Xueyuan Wang Xuezhe Wei Haifeng Dai 《Chain》 2025年第2期148-163,共16页
Lithium plating has been identified as the main form of failure in fast charging,so it is imperative to develop effective methods for detecting lithium plating.Experimental results validated the effectiveness of lithi... Lithium plating has been identified as the main form of failure in fast charging,so it is imperative to develop effective methods for detecting lithium plating.Experimental results validated the effectiveness of lithium plating detection via expansion force measurement.While multi-stage constant current(MCC)charging is a common form of fast charging,experimental investigations of lithium plating under MCC charging remain scarce,particularly lacking models to describe the battery expansion force changes during the lithium plating process under MCC conditions.The expansion of batteries during charging is caused by factors such as intercalation reactions,thermal expansion,and lithium plating.Through the establishment of the coupling model,the expansion displacement of the battery is calculated.The thermal expansion coefficient and equivalent stiffness of the battery are obtained through experiments,which are used to calculate the battery expansion force.Additionally,the battery overpotential is calculated through the model to determine the impact of lithium plating on the expansion force.The model investigates the effects of lithium plating on battery expansion force under different C-rates during constant current and MCC charging processes,achieving semi-quantitative prediction of battery expansion force under MCC charging and providing model-based optimization directions for MCC charging strategies.This work provides valuable insights for battery modeling and charging strategy optimization in terms of expansion force modeling under multi-stage constant current charging. 展开更多
关键词 lithium-ion battery lithium plating coupling model expansion force multi-stage constant current
原文传递
On maximum power point tracking control strategy for variable speed constant frequency wind power generation 被引量:1
20
作者 倪红军 《Journal of Chongqing University》 CAS 2010年第1期21-28,共8页
Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum ... Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum output power point can be tracked by decoupling control of active power and reactive power.The research result shows that the net power of generation system delivered to grid in maximum wind energy tracking mode is not the most.We presented a novel maximum power point tracking(MPPT)control strategy by analyzing the DFIG mathematic model and power relations which delivered the maximum power to the grid.The maximum power point could be tracked automatically without measuring wind speed in the control strategy and the control was independent of optimal turbine power curve,which had excellent dynamic and static performances and robustness.Simulation and experimental results testify the accuracy and validity of the control strategy. 展开更多
关键词 variable speed constant frequency grid voltage orientation DECOUPLING maximum power point tracking
在线阅读 下载PDF
上一页 1 2 198 下一页 到第
使用帮助 返回顶部