This paper is a research design based on EFPT process control device.In the design,actual industry field has been simulated and corresponding modelling has been carried on for the boiler level system.Then the appropri...This paper is a research design based on EFPT process control device.In the design,actual industry field has been simulated and corresponding modelling has been carried on for the boiler level system.Then the appropriate PID parameter has been sorted out and ControlLogix5550 PLC has been used to control the entire boiler level system.At last,a corresponding control interface has been established and the boiler level has been under a safe and accurate control.展开更多
This paper proposed a simple approach to determine noise frequency of boiler drum level in order to improve control performance. Based on analysis of uncertainty of drum level, the redundant oscillation component of s...This paper proposed a simple approach to determine noise frequency of boiler drum level in order to improve control performance. Based on analysis of uncertainty of drum level, the redundant oscillation component of signal, noise is ascribed to the surface wave of drum water. According to the characteristic of surface wave, a new method was proposed to determine noise’s frequency band. By gradually removing the lowest frequency component of signal, the variance of remained component is calculated and observed. An apparent turning point was found and the corresponding critical frequcncy was determined. With this result a low-pass filter was designed to separate noise component. Finally validation is conducted by comparing the proposed method and conventional ones. Results show the accuracy and simpleness of the proposed method.展开更多
It is always quite difficult to accurately measure boiler drum water level in power plant. Though the effect of false measurement of water level can be reduced with some devices, the effect of deviation of boiler drum...It is always quite difficult to accurately measure boiler drum water level in power plant. Though the effect of false measurement of water level can be reduced with some devices, the effect of deviation of boiler drum water level to the monitoring and alarm system, even to the control of drum water level, and so on, cannot be surmounted. Because of these reasons, the accurate water level alarm signal cannot be provided and the water level control measures cannot be applied. In order to solve this problem, a water level deviation analysis method is presented for analyzing boiler drum water level. Based on the analysis of boiler drum water level related running parameters, the relational model of water level deviation under different working conditions and its parameters is constructed. By analyzing this model, the specific impacts of the main factors can be fixed. Thus the drum water level deviation can be reduced by adjusting running parameters without changing unit load. And then the measurement of drum water level can be more accurate only if power plants have accurate measuring devices. Therefore, the boiler drum water level can be more accurately monitored and controlled. So, this innovation is important in ensuring the safe running of power plant.展开更多
文摘This paper is a research design based on EFPT process control device.In the design,actual industry field has been simulated and corresponding modelling has been carried on for the boiler level system.Then the appropriate PID parameter has been sorted out and ControlLogix5550 PLC has been used to control the entire boiler level system.At last,a corresponding control interface has been established and the boiler level has been under a safe and accurate control.
文摘This paper proposed a simple approach to determine noise frequency of boiler drum level in order to improve control performance. Based on analysis of uncertainty of drum level, the redundant oscillation component of signal, noise is ascribed to the surface wave of drum water. According to the characteristic of surface wave, a new method was proposed to determine noise’s frequency band. By gradually removing the lowest frequency component of signal, the variance of remained component is calculated and observed. An apparent turning point was found and the corresponding critical frequcncy was determined. With this result a low-pass filter was designed to separate noise component. Finally validation is conducted by comparing the proposed method and conventional ones. Results show the accuracy and simpleness of the proposed method.
基金supported by the State Key Program of National Natural Science Foundation of China(No.61034004)Shanghai Science and Technology Commission Key Program(Nos.14DZ2251100,15510722100 and 15111106800)Shanghai Key Laboratory of Power Station Automation Technology(No.13DZ2273800)
文摘It is always quite difficult to accurately measure boiler drum water level in power plant. Though the effect of false measurement of water level can be reduced with some devices, the effect of deviation of boiler drum water level to the monitoring and alarm system, even to the control of drum water level, and so on, cannot be surmounted. Because of these reasons, the accurate water level alarm signal cannot be provided and the water level control measures cannot be applied. In order to solve this problem, a water level deviation analysis method is presented for analyzing boiler drum water level. Based on the analysis of boiler drum water level related running parameters, the relational model of water level deviation under different working conditions and its parameters is constructed. By analyzing this model, the specific impacts of the main factors can be fixed. Thus the drum water level deviation can be reduced by adjusting running parameters without changing unit load. And then the measurement of drum water level can be more accurate only if power plants have accurate measuring devices. Therefore, the boiler drum water level can be more accurately monitored and controlled. So, this innovation is important in ensuring the safe running of power plant.