期刊文献+
共找到3,053篇文章
< 1 2 153 >
每页显示 20 50 100
Flow separation control over an airfoil using continuous alternating current plasma actuator 被引量:1
1
作者 Jian-Guo Zheng 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期346-355,共10页
The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to re... The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to report some observations made from our experiment,to which little attention is paid in the previous studies,but which is thought to be important to the understanding of control of complex flow separation with AC DBD.To this end,the response of separated flow to AC plasma actuation is visualized through the time-resolved particle image velocimetry(PIV)measurement,whereas numerical simulation is carried out to complement the experiment.The flow control process at chord-based Reynolds number(Re)of 3.31×105 is investigated.It is found that the response of external flow to plasma forcing is delayed for up to tens of milliseconds and the delay time increases with angle of attack increasing.Also observed is that at the intermediate angle of attack near stall,the forced flow features a well re-organized flow pattern.However,for airfoil at high post-stall angle of attack,the already well suppressed flow field can recover to the massively separated flow state and then reattach to airfoil surface with the flow pattern fluctuating between the two states in an irregular manner.This is contrary to one’s first thought that the forced flow at any angles of attack will become well organized and regular,and reflects the complexity of flow separation control. 展开更多
关键词 dielectric barrier discharge plasma actuator alternating current plasma discharge flow separation flow control delayed response
原文传递
Effect of theta-transcranial alternating current stimulation on working memory performance among healthy adults:A systematic review and meta-analysis
2
作者 Tian-Ya Hou Xiao-Fei Mao Rui-Ke Zhang 《World Journal of Psychiatry》 2025年第9期328-341,共14页
BACKGROUND Working memory serves as a fundamental cognitive function that substantially impacts performance in various cognitive tasks.Extensive neurophysiological research has established that theta oscillations(4-8 ... BACKGROUND Working memory serves as a fundamental cognitive function that substantially impacts performance in various cognitive tasks.Extensive neurophysiological research has established that theta oscillations(4-8 Hz)play an essential role in supporting working memory operations.Theta-band transcranial alternating current stimulation(tACS)offers a potential mechanism for working memory enhancement through direct modulation of these fundamental neural oscillations.Nevertheless,current empirical evidence shows substantial variability in the observed effects of theta-tACS across studies.AIM To conduct a systematic review and meta-analysis evaluating the effects of thetatACS on working memory performance in healthy adults.METHODS A systematic literature search was performed on PubMed,EMBASE,and Web of Science up to March 10,2025.Effect sizes were computed using Hedges’g with 95%confidence intervals(CIs),with separate meta-analyses for all included studies and for distinct working memory paradigms[n-back and delayed matchto-sample(DMTS)tasks]to examine potential task-specific effects.Subgroup analyses and meta-regression were performed to evaluate the influence of key moderating variables.RESULTS The systematic review included 21 studies(67 effect sizes).Initial meta-analysis showed theta-tACS moderately improved working memory(Hedges’g=0.405,95%CI:0.212-0.598).However,this effect became nonsignificant after correcting for publication bias(trim-and-fill adjusted Hedges’g=0.082,95%CI:-0.052 to 0.217).Task-specific analyses revealed significant benefits in n-back tasks(Hedges’g=0.463,95%CI:0.193-0.733)but not in DMTS tasks(Hedges’g=0.257,95%CI:-0.186 to 0.553).Moderator analyses showed that performance in n-back tasks was influenced by stimulation frequency(P=0.001),concurrent status(P=0.014),task modality(P=0.005),and duration(P=0.013),whereas only the region of targeted stimulation(P=0.012)moderated DMTS tasks.CONCLUSION Theta-tACS enhances working memory in healthy adults,with effects modulated by the task type and protocol parameters,offering dual implications for cognitive enhancement and clinical interventions. 展开更多
关键词 Working memory Transcranial alternating current stimulation THETA Healthy adults N-BacK Delayed match-tosample task
暂未订购
Experimental design to measure the anchoring energy on substrate surface by using the alternating-current bridge 被引量:1
3
作者 郝慧明 刘瑶瑶 +4 位作者 张平 蔡明雷 王晓燕 朱吉亮 叶文江 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第8期315-319,共5页
The anchoring property of the substrate surface of liquid crystal cells plays an important role in display and nondisplay fields. This property directly affects the deformation of liquid crystal molecules to change th... The anchoring property of the substrate surface of liquid crystal cells plays an important role in display and nondisplay fields. This property directly affects the deformation of liquid crystal molecules to change the phase difference through liquid crystal cells. In this paper, a test method based on the alternating-current bridge is proposed to determine the capacitance of liquid crystal cells and thus measure the anchoring energy of the substrate surface. The anchoring energy can be obtained by comparing the capacitance-voltage curves of twisted nematic liquid crystal cells with different anchoring properties in experimental and theoretical results simulated on the basis of Frank elastic theory. Compared with the other methods to determine the anchoring energy, our proposed method requires a simple treatment of liquid crystal cells and allows easy and high-accuracy measurements, thereby expanding the test ideas on the performance parameters of liquid crystal devices. 展开更多
关键词 anchoring energy alternating-current bridge capacitance of liquid crystal cell twisted nematic
原文传递
Electrical Characteristics of an Alternating Current Plasma Igniter in Airflow
4
作者 赵兵兵 何立明 +1 位作者 杜宏亮 张华磊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期370-373,共4页
The electrical characteristics of an alternating current (AC) plasma igniter were investigated for a working gas of air at atmospheric pressure. The discharge voltage and current were measured in air in both breakdo... The electrical characteristics of an alternating current (AC) plasma igniter were investigated for a working gas of air at atmospheric pressure. The discharge voltage and current were measured in air in both breakdown and stable combustion processes, respectively, and the current-zero phenomena, voltage-current (V-I) characteristics were studied for different working gas flow rates. The results indicated that the working gas between anode and cathode could be ionized to generate gas discharge when the voltage reached 8 kV, and the maximum current was 33.36 A. When the current came to zero, current-zero phenomena appeared with duration of 2 #s. At the current-zero moment, dynamic resistance between electrodes became extremely high, and the maximum value could reach 445 kf~, which was the main factor to restrain the current. With increasing working gas flow rates, the gradient of V-I characteristic curves was increased, as was the dynamic resistance. At a constant driven power, the discharge voltage increased. 展开更多
关键词 alternating current discharge plasma igniter voltage-current characteristic current-zero phenomena
在线阅读 下载PDF
Characterization of alternating current impedance properties of biomedical electrodes
5
作者 周伟 程德才 +3 位作者 宋嵘 张春健 许文平 潘晓玲 《Journal of Central South University》 SCIE EI CAS 2013年第5期1254-1258,共5页
To study the alternating current (AC) impedance properties of Ag/AgC1 electrocardiograph (ECG) electrodes, the electrode pair was gel-to-gel connected, and then the electrical potential was recorded after a safe s... To study the alternating current (AC) impedance properties of Ag/AgC1 electrocardiograph (ECG) electrodes, the electrode pair was gel-to-gel connected, and then the electrical potential was recorded after a safe stimulating current passes through the electrode pair, so the AC impedance data of ECG electrodes were obtained. Varying the frequency and value of stimulating current, the detailed comparison and analysis of AC impedance properties of the electrodes were performed, and the stability was further characterized by using the continuous measurement within 24 h. The experimental results show that the AC impedance values of electrodes decreased, and then slightly increased with the increase of frequency of stimulating current. The minimum AC impedance value was obtained when the frequency was changed to 10 kHz. When the stimulating current increased, the AC impedance values of electrodes showed a slight decrease, but did not change significantly. Besides, the continuous measurement results show that the impedance value presented a significant increase in the initial 30 min, and then was stabilized in the following measuring process. 展开更多
关键词 bioelectrical impedance electrocardiograph electrodes alternating current impedance frequency properties currentproperties
暂未订购
In Situ Coupling of Reduction and Oxidation Processes with Alternating Current-Driven Bioelectrodes for Efficient Mineralization of Refractory Pollutants
6
作者 Ye Yuan Junjie Zhang +7 位作者 Wanxin Yin Lulu Zhang Lin Li Tianming Chen Cheng Ding Wenzong Liu Aijie Wang Fan Chen 《Engineering》 CSCD 2024年第12期125-138,共14页
The effective elimination of aromatic compounds from wastewater is imperative for safeguarding the ecological environment.Bioelectrochemical processes that combine cathodic reduction and anodic oxidation represent a p... The effective elimination of aromatic compounds from wastewater is imperative for safeguarding the ecological environment.Bioelectrochemical processes that combine cathodic reduction and anodic oxidation represent a promising approach for the biomineralization of aromatic compounds.However,conventional direct current bioelectrochemical methods have intrinsic limitations.In this study,a low-frequency and low-voltage alternating current(LFV-AC)-driven bioelectrode offering periodic in situ coupling of reduction and oxidation processes was developed for the biomineralization of aromatic compounds,as exemplified by the degradation of alizarin yellow R(AYR).LFV-AC stimulated biofilm demonstrated efficient bidirectional electron transfer and oxidation–reduction bifunctionality,considerably boosting AYR reduction(63.07%±1.91%)and subsequent mineralization of intermediate products(98.63%±0.37%).LFV-AC stimulation facilitated the assembly of a collaborative microbiome dedicated to AYR metabolism,characterized by an increased abundance of functional consortia proficient in azo dye reduction(Stenotrophomonas and Bradyrhizobium),aromatic intermediate oxidation(Sphingopyxis and Sphingomonas),and electron transfer(Geobacter and Pseudomonas).The collaborative microbiome demonstrated a notable enrichment of functional genes encoding azo-and nitro-reductases,catechol oxygenases,and redox mediator proteins.These findings highlight the effectiveness of LFV-AC stimulation in boosting azo dye biomineralization,offering a novel and sustainable approach for the efficient removal of refractory organic pollutants from wastewater. 展开更多
关键词 alternating current Bioelectrode Redox process Bio-mineralization Electrode microbiome Refractory organic pollutants
在线阅读 下载PDF
Research on the electrical characteristics of an organic thin-film field-effect transistor based on alternating-current resistance
7
作者 陈跃宁 徐征 +4 位作者 赵谡玲 尹飞飞 张成文 焦碧媛 董宇航 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第12期385-388,共4页
In this article, an organic thin-film field-effect transistor (OTFFET) with top-gate and bottom-contact geometry based on pentacene as the active layer is fabricated. The experimental data of the I-V are obtained fr... In this article, an organic thin-film field-effect transistor (OTFFET) with top-gate and bottom-contact geometry based on pentacene as the active layer is fabricated. The experimental data of the I-V are obtained from the OTFFET device. The alternating-current (AC) resistance value of the OTFFET device is calculated using the derivation method from the experimental data, and the AC resistance trend curves of the OTFFET device are obtained with the region fitting method. We analyse the characteristics of the OTFFET device with an AC resistance trend curve. To discover whether it has a high resistance, it is proposed to judge the region of the source/drain voltage (VDs) less than the transition voltage, thereby determining whether the contact between the metal electrode and the organic semiconductor layer of the OTFFET device is Ohmic or non-Ohmic. The theoretical analysis shows that the field-effect mobility and the AC resistance are in reverse proportion. Therefore, we point out that reducing AC resistance is necessary if field-effect mobility is to be improved. 展开更多
关键词 organic thin-film field-effect transistor alternating-current resistance Ohmic contact
原文传递
进一步改善ACS抗血小板治疗效果:CURRENT OASIS 7浅析 被引量:1
8
作者 刘兆平 《中国医学前沿杂志(电子版)》 2009年第2期62-64,共3页
急性冠脉综合征(acute coronary syndromes,ACS)的病生理机制决定了抗血小板治疗是ACS药物治疗的基石,对于接受经皮冠状动脉介入治疗(percutaneous transluminal coronary intervention,PCD的患者尤其如此。
关键词 抗血小板治疗 介入治疗 PCI 患者 心肌梗死 acS current OASIS 7 支架内血栓 普拉格雷 双倍剂量 复合终点 出血风险
暂未订购
基于线性化的单级式双有源桥AC-DC变换器最小电流应力控制策略 被引量:1
9
作者 王要强 钟正阳 +2 位作者 李想 聂福全 梁军 《电工技术学报》 北大核心 2025年第10期3224-3235,共12页
针对单级式双有源桥AC-DC变换器调制非线性和电流应力较大的问题,该文提出一种基于线性化的变换器最小电流应力控制策略。首先,分析扩展移相(EPS)调制策略的开关特性,对于输入电流与移相比呈非线性的特点,提出一种线性化变频移相控制策... 针对单级式双有源桥AC-DC变换器调制非线性和电流应力较大的问题,该文提出一种基于线性化的变换器最小电流应力控制策略。首先,分析扩展移相(EPS)调制策略的开关特性,对于输入电流与移相比呈非线性的特点,提出一种线性化变频移相控制策略。其次,通过微分极值法实现变换器电流应力的最小化,该控制策略不仅可以降低变换器的控制复杂度,还可以在有效降低变换器电流应力的同时保证开关管具有较宽零电压开通(ZVS)范围,并且移相比和开关频率以解析形式获得,计算简单、易于实现。最后,通过仿真和实验对该文所提控制策略进行验证,证明了该控制策略的可行性。 展开更多
关键词 ac-DC变换器 扩展移相 线性化 最小电流应力 零电压软开关
在线阅读 下载PDF
核电站乏燃料水池水下ACFM焊缝缺陷检测系统研究 被引量:1
10
作者 沈光耀 张晓春 +2 位作者 朱加雷 李丛伟 田正磊 《精密成形工程》 北大核心 2025年第1期223-231,共9页
目的针对核电站乏燃料水池钢覆面焊缝缺陷的水下检测需求,开发一种基于交流电磁场检测(ACFM)技术的水下缺陷检测系统,以检测和识别焊缝中的微小漏点,进而确保乏燃料水池的结构完整性和运行安全。方法采用有限元模拟结合实验验证的研究... 目的针对核电站乏燃料水池钢覆面焊缝缺陷的水下检测需求,开发一种基于交流电磁场检测(ACFM)技术的水下缺陷检测系统,以检测和识别焊缝中的微小漏点,进而确保乏燃料水池的结构完整性和运行安全。方法采用有限元模拟结合实验验证的研究方法。首先,采用三代核电乏燃料水池钢覆面的主要材料S32101双向不锈钢作为研究对象,利用COMSOL Multiphysics软件建立ACFM的缺陷检测模型,并对激励频率、激励电流进行优化分析。其次,研制了适用于核电水下环境的ACFM缺陷检测设备,并通过水压、电磁干扰、辐照试验来验证设备的可靠性。结果当激励频率为1~5 kHz并采用较大的激励电流时,可以获得最佳的检测效果;试验结果表明,系统在辐照水下环境中具有良好的适用性,能够有效检测并识别出直径为0.1 mm的微孔贯穿缺陷及3 mm×0.2 mm×0.5 mm的浅表缺陷。结论综合仿真分析、设备研制和实验验证的结果可知,所开发的水下ACFM缺陷检测系统能够满足核电站乏燃料水池钢覆面焊缝缺陷的水下检测需求,为核设施水下缺陷的早期预警和漏点判定提供了有效的技术手段。 展开更多
关键词 乏燃料水池 S32101 水下缺陷检测 交流电磁场检测 试验
在线阅读 下载PDF
Effects of alternating current interference on corrosion of X60 pipeline steel 被引量:10
11
作者 Yan-Bao Guo Cheng Liu +1 位作者 De-Guo Wang Shu-Hai Liu 《Petroleum Science》 SCIE CAS CSCD 2015年第2期316-324,共9页
With rapid economic development in China, demand for energy and transportation is growing. Due to the limitations of factors such as terrain and traffic, a large number of buried oil and gas pipelines are parallel to ... With rapid economic development in China, demand for energy and transportation is growing. Due to the limitations of factors such as terrain and traffic, a large number of buried oil and gas pipelines are parallel to high- voltage transmission lines and electrified railways over long distances. Alternating pipelines is very serious in laboratory experiments were current (AC) corrosion of such cases. In this work, carried out with an electrochemical method in a simulated soil solution at various AC current densities from 0 to 200 A]m2 and AC frequencies from 10 to 200 Hz. Experimental results indicated that with an increase in the AC current density, the corrosion po- tential of an X60 steel electrode shifted negatively, the anodic current density increased significantly, and the corrosion rate increased. Moreover, with an increase in the AC frequency, the corrosion potential of the X60 electrode shifted positively and the anodic current density decreased, which led to a decrease in the corrosion rate. Furthermore, the morphology of X60 electrodes indicated that uniform corrosion occurred at a low AC current density; while corrosion pits were found on the X60 electrode surface at a high AC current density, and deep corrosion pits seriously damaged the pipelines and might lead to leakage. 展开更多
关键词 alternating current interference - X60pipeline steel CORROSION ac current density - acfrequency
原文传递
Reversibility of visual field defects through induction of brain plasticity: vision restoration, recovery and rehabilitation using alternating current stimulation 被引量:9
12
作者 Bernhard A.Sabel Ying Gao Andrea Antal 《Neural Regeneration Research》 SCIE CAS CSCD 2020年第10期1799-1806,共8页
For decades visual field defects were considered irreversible because it was thought that in the visual system the regeneration potential of the neuronal tissues is low.Nevertheless,there is always some potential for ... For decades visual field defects were considered irreversible because it was thought that in the visual system the regeneration potential of the neuronal tissues is low.Nevertheless,there is always some potential for partial recovery of the visual field defect that can be achieved through induction of neuroplasticity.Neuroplasticity refers to the ability of the brain to change its own functional architecture by modulating synaptic efficacy.It is maintained throughout life and just as neurological rehabilitation can improve motor coordination,visual field defects in glaucoma,diabetic retinopathy or optic neuropathy can be improved by inducing neuroplasticity.In ophthalmology many new treatment paradigms have been tested that can induce neuroplastic changes,including non-invasive alternating current stimulation.Treatment with alternating current stimulation(e.g.,30 minutes,daily for 10 days using transorbital electrodes and^10 Hz)activates the entire retina and parts of the brain.Electroencephalography and functional magnetic resonance imaging studies revealed local activation of the visual cortex,global reorganization of functional brain networks,and enhanced blood flow,which together activate neurons and their networks.The future of low vision is optimistic because vision loss is indeed,partially reversible. 展开更多
关键词 alternating current stimulation glaucoma low vision optic nerve REHABILITATION RECOVERY stress VISION vision restoration therapy visual field
暂未订购
Fabrication of TiO_2 Nanotube Arrays by Rectified Alternating Current Anodization 被引量:2
13
作者 Han Song Jing Shang Chen Suo 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2015年第1期23-29,共7页
Anodization is a popular method of preparing TiO2nanotube array films(TiNTs) by using direct current(DC)power as the driving voltage.In this study,three driving voltage modes,namely,the sine alternating current(s... Anodization is a popular method of preparing TiO2nanotube array films(TiNTs) by using direct current(DC)power as the driving voltage.In this study,three driving voltage modes,namely,the sine alternating current(sine) mode,the full-wave rectification of sine waves via four diodes(sine-4D,where D means diode) mode,and the DC mode,were used to prepare TiNTs by anodization.At 20 V,TiNTs were formed under sine-4D mode but only irregular porous TiO2films were formed under DC mode.At 50 V,TiNTs formed under both the sine-4D and DC modes.No TiNTs formed in the sine mode anodization at either 20 or 50 V.Compared with the DC mode,the sine-4D mode required a lower oxidation voltage for TiNT formation,which suggests that sine-4D is an economical,convenient,and efficient driving voltage for TiNT preparation by anodization.The morphologies and structures of TiNT samples anodized at 50 V in the sine-4D and DC modes at different oxidation time(1,5,10,30,60,and 120 min) were analyzed.TiNT growth processes were similar between the studied modes.However,the growth rate of the films was faster under the sine-4D mode than the DC mode during the first 30 min of anodization. 展开更多
关键词 TiO2nanotube Anodization alternating current Growt
原文传递
Alternating Pulse Current in Eiectrocoagulation for Wastewater Treatment to Prevent the Passivation of Al Electrode 被引量:2
14
作者 MAO Xuhui HONG Song +3 位作者 ZHU Hua LIN Hui WEI Lin GAN Fuxing 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第2期239-241,共3页
A novel current feed style, alternating pulse current, was proposed in electrocoagulation aiming at preventing the passivation of electrode materials. The open circuit potential (OCP) measurements after anodic and c... A novel current feed style, alternating pulse current, was proposed in electrocoagulation aiming at preventing the passivation of electrode materials. The open circuit potential (OCP) measurements after anodic and cathodic potentiodynamic polarization showed that cathodic polarization could activate Al electrode. The surface of Al electrode after alternating pulse current electrocoagulation was investigated by scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS), and the results indicate that passivation of Al is not observed. Furthermore, the simulated wastewater treatment tests show that alternating pulse current electrocoagulation has a visible energy saving effect and is worthy of generalization. 展开更多
关键词 alternating pulse current ELECTROCOAGULATION passivation of Al
在线阅读 下载PDF
Sediment Movement in Periodic Alternating Current 被引量:11
15
作者 CAOZude KONGLingshuang LIUDefu 《Journal of Ocean University of Qingdao》 2002年第2期201-205,共5页
The present paper summarizes the results of previous studies, including the structure and principle of the rotary ring flume for researching the fine sediment movement, the mechanism of the flume, method of eliminatin... The present paper summarizes the results of previous studies, including the structure and principle of the rotary ring flume for researching the fine sediment movement, the mechanism of the flume, method of eliminating the influence of the centrifugal force and sediment movement experiments with periodic alternating current. Also included are the experiment-based relationship among sediment concentration, bed shear stress and silt carrying capacity, a proposed erosion-deposition function and bed erosion-deposition calculation together with the results of verification. 展开更多
关键词 rotary ring flume periodic alternating current hydraulic characteristics of sediment erosion-deposition function
在线阅读 下载PDF
Evolution of Solidification Structure of Hypereutectic Al-Si Alloy Under a Novel Low-Voltage Alternating Current Pulse 被引量:1
16
作者 ZHANG Li-min ZHANG Rong +2 位作者 LI Ning CHEN Wen-jing DU Li-fei 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2012年第S1期355-358,共4页
The effect of a novel low-voltage alternating current pulse(ACP)controlled by transformer and silicon controlled rectifier on the solidification structure of Al-20%Si alloy was investigated.The results indicated that ... The effect of a novel low-voltage alternating current pulse(ACP)controlled by transformer and silicon controlled rectifier on the solidification structure of Al-20%Si alloy was investigated.The results indicated that the remarkable segregation of primary Si occurred during the solidification,and even dendrites of a-Al phase appeared at the center of samples under ACP.The thickness of segregation layer decreased first and then increased with current density increasing from 0 to 300 Acm^(-2).The primary Si existed with long pole or five petal star-shaped without ACP.However, the morphology of primary Si phases changed to block under ACP,and the sizes of blocky Si decreased obviously with increasing current density from 110 to 300 Acm^(-2).The formation mechanism of the structure of hypereutectic AI-20%Si alloy was also discussed under ACP. 展开更多
关键词 A low-voltage alternating current pulse MacROSEGREGATION Morphology of Si Al-Si alloy
原文传递
Alternating current heating techniques for lithium-ion batteries in electric vehicles:Recent advances and perspectives 被引量:1
17
作者 Xinrong Huang Jinhao Meng +5 位作者 Wei Jiang Wenjie Liu Kailong Liu Yipu Zhang Daniel-Ioan Stroe Remus Teodorescu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第9期679-697,共19页
The significant decrease in battery performance at low temperatures is one of the critical challenges that electric vehicles(EVs)face,thereby affecting the penetration rate in cold regions.Alternating current(AC)heati... The significant decrease in battery performance at low temperatures is one of the critical challenges that electric vehicles(EVs)face,thereby affecting the penetration rate in cold regions.Alternating current(AC)heating has attracted widespread attention due to its low energy consumption and uniform heating advantages.This paper introduces the recent advances in AC heating from the perspective of practical EV applications.First,the performance degradation of EVs in low-temperature environments is introduced briefly.The concept of AC heating and its research methods are provided.Then,the effects of various AC heating methods on battery heating performance are reviewed.Based on existing studies,the main factors that affect AC heating performance are analyzed.Moreover,various heating circuits based on EVs are categorized,and their cost,size,complexity,efficiency,reliability,and heating rate are elaborated and compared.The evolution of AC heaters is presented,and the heaters used in brand vehicles are sorted out.Finally,the perspectives and challenges of AC heating are discussed.This paper can guide the selection of heater implementation methods and the optimization of heating effects for future EV applications. 展开更多
关键词 Lithium-ion battery Low temperature alternating current heating HEATER Electric vehicle
在线阅读 下载PDF
Monitoring the spontaneous wetting process of hydrophobic microporous membrane assisted by alternating current impedance spectroscopy 被引量:1
18
作者 Juntian Xiao Qian Sun +1 位作者 Liying Liu Zhongwei Ding 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第11期96-102,共7页
In the process of membrane absorption,spontaneous wetting of hydrophobic microporous membrane causes membrane modification and increases membrane phase mass transfer resistance,which have attracted wide interest.Howev... In the process of membrane absorption,spontaneous wetting of hydrophobic microporous membrane causes membrane modification and increases membrane phase mass transfer resistance,which have attracted wide interest.However,due to the limitations of previous testing methods,the study of the spontaneous membrane wetting process is limited.Herein,we present a method for monitoring spontaneous membrane wetting by measuring its alternating current(AC)impedance.The impedance tests of the PVDF flat membranes and hollow fiber membranes were conducted in a two-electrode system.The results of equivalent circuit fitting indicate that the impedance value of the unwetted membrane is about 1.02×10^(10)Ω,which is close to the theoretical value of 1.4×10^(10)Ω,and this method can quantify the electrochemical impedance value of membranes with different degrees of spontaneous wetting.In addition,a method of impedance test for real-time monitoring of spontaneous wetting was designed.During the experiment,the timeliness and continuity of this method are confirmed with exact judgment under different conditions.In future work,the impedance data will be used to build model to predict the percentage of membrane wetting degree. 展开更多
关键词 alternating current impedance Spontaneous membrane wetting Hydrophobic membrane Dynamic monitoring
在线阅读 下载PDF
Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration 被引量:6
19
作者 Jun Ping Xiao Qing Xiang Zhou +2 位作者 Xiao Ke Tian Hua Hua Bai Xian Fa Su 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期730-733,共4页
A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosa... A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail. The experimental results indicated that this method was simple, rapid, and sensitive. The linear range was 8.367 × 10(?4) to 2.789 × 10(?2) mol L(?1), the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4–106.9% under the optimal conditions. The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples. 展开更多
关键词 alternating-current oscillopolarographic titration ANILINE Potassium bromide
在线阅读 下载PDF
Soft measurement model on torque of alternating current electrical dynamometer including copper loss and iron loss 被引量:1
20
作者 ZHONG Ding-qing WANG Ai-lun HE Qian 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第8期2272-2280,共9页
Alternating current electrical dynamometer is a common device to measure the torque of engines, such as the gasoline engine. In order to solve the problems such as high cost, high energy consumption and complicated me... Alternating current electrical dynamometer is a common device to measure the torque of engines, such as the gasoline engine. In order to solve the problems such as high cost, high energy consumption and complicated measurement system which exists in the direct measurement on the torque of alternating current electrical dynamometer, copper loss and iron loss are taken as two key factors and a soft-sensing model on the torque of alternating current electrical dynamometer is established using the fuzzy least square support vector machine (FLS-SVM). Then, the FLS-SVM parameters such as penalty factor and kernel parameter are optimized by adaptive genetic algorithm, torque soft-sensing is investigated in the alternating current electrical dynamometer, as well as the energy feedback efficiency and energy consumption during the measurement phase of a gasoline engine loading continual test is obtained. The results show that the minimum soft-sensing error of torque is about 0.0018, and it fluctuates within a range from -0.3 to 0.3 N·m. FLS-SVM soft-sensing method can increase by 1.6% power generation feedback compared with direct measurement, and it can save 500 kJ fuel consumption in the gasoline engine loading continual test. Therefore, the estimation accuracy of the soft measurement model on the torque of alternating current electrical dynamometer including copper loss and iron loss is high and this indirect measurement method can be feasible to reduce production cost of the alternating current electrical dynamometer and energy consumption during the torque measurement phase of a gasoline engine, replacing the direct method of torque measurement. 展开更多
关键词 TORQUE fuzzy theory least square support vector machine alternating current electrical dynamometer
在线阅读 下载PDF
上一页 1 2 153 下一页 到第
使用帮助 返回顶部