Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System 被引量:1
1
作者 SU Shun-yu ZHANG Chun-zhi CHEN Jian 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期91-95,共5页
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.... This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary. 展开更多
关键词 air-source heat pump control strategy distributed parameter model charge inventory
在线阅读 下载PDF
Applicability of sewage heat pump air-conditioning system
2
作者 陈金华 刘猛 +2 位作者 刘勇 靳鸣 陈洁 《Journal of Central South University》 SCIE EI CAS 2009年第S1期183-187,共5页
A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. ... A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly. 展开更多
关键词 SEWAGE heat pump air CONDITIONING system NUMERICAL calculation energy efficiency environmental FRIENDLINESS
在线阅读 下载PDF
Cavitation Control in Mixed-Flow Pumps through Blade Perforation
3
作者 Chaoyu Wei Haipeng Zhang +4 位作者 Weidong Shi Yongfei Yang Linwei Tan Xianglong Wu Yurui Dai 《Fluid Dynamics & Materials Processing》 2026年第2期205-224,共20页
During high-speed operation,mixed-flow pumps are susceptible to cavitation,which destabilizes the internal flow,increases energy losses,and degrades hydraulic efficiency.To assess the effectiveness of blade perforatio... During high-speed operation,mixed-flow pumps are susceptible to cavitation,which destabilizes the internal flow,increases energy losses,and degrades hydraulic efficiency.To assess the effectiveness of blade perforation as a cavitation-mitigation strategy,in this study several mixed-flow pump models incorporating perforations were developed.Numerical simulations were performed for configurations with circular holes positioned at different locations along the blade leading edge,and the computational results were validated against experimental measurements.The findings indicate that the location of the perforations plays a decisive role in cavitation suppression.Moving from the blade rim toward the hub along the leading edge,the critical net positive suction head,NPSH_(cr),initially decreases and subsequently increases,while remaining consistently lower than that of the reference non-perforated configuration.The perforations promote the transfer of high-pressure fluid from the pressure side to the suction side of the blade,thereby alleviating local low-pressure regions.This pressure compensation significantly reduces the extent of low-pressure zones in the vicinity of the perforations,leading to a marked suppression of cavitation both locally and downstream of the perforated regions. 展开更多
关键词 Cavitation suppression numerical simulation mixed-flow pump blade perforation
在线阅读 下载PDF
Performance Evaluation of the Hybrid Heat Pump to Decarbonize the Buildings Sector:Energetic,Environmental and Economic Characterization
4
作者 Miriam DiMatteo Domiziana Vespasiano +2 位作者 Gianluigi Lo Basso Costanza Vittoria Fiorini Andrea Vallati 《Energy Engineering》 2026年第2期1-37,共37页
Decarbonising the building sector,particularly residential heating,represents a critical challenge for achieving carbon-neutral energy systems.Efficient solutions must integrate both technological performance and rene... Decarbonising the building sector,particularly residential heating,represents a critical challenge for achieving carbon-neutral energy systems.Efficient solutions must integrate both technological performance and renewable energy sources while considering operational constraints of existing systems.This study investigates a hybrid heating system combining a natural gas boiler(NGB)with an air-to-water heat pump(AWHP),evaluated through a combination of laboratory experiments and dynamic modelling.A prototype developed in the Electrical and Energy Engineering Laboratory enabled the characterization of both heat generators,the collection of experimental data,and the calibration of a MATLAB/Simulink model,including emissions and exhaust analyses.Sensitivity analyses were performed to identify optimal configurations for energy efficiency and system control,accounting for interactions between subsystems.Results highlight that hybridisation significantly improves primary energy efficiency and reduces fuel consumption compared to conventional NGB-only systems.Environmental performance,assessed through CO_(2) and NOx emissions and renewable energy integration,demonstrates the benefits of partial electrification in the residential sector.Economic assessment further quantifies decarbonization costs and fuel savings,illustrating tradeoffs between low-capital,moderate-performance systems and high-efficiency,high-renewable solutions requiring larger investments.The analysis shows that strategic decisions for residential decarbonisation cannot be separated from system-wide considerations,including control strategies,component integration,and economic feasibility.The study underlines the importance of hybrid and renewable-based solutions as pivotal pathways for energy transition in the residential building sector. 展开更多
关键词 Hybrid heat pump laboratory measurements decarbonization environmental analysis energy analysis economic analysis
在线阅读 下载PDF
Influence of surface defects on the working performance of mechanical seals for nuclear reactor coolant pumps
5
作者 Xiang Zhao Ying Liu +2 位作者 Quanchao Yang Xue Wen Anqi Huang 《Chinese Journal of Mechanical Engineering》 2026年第1期311-321,共11页
Nuclear reactor coolant pumps require frequent maintenance to ensure operational safety.One critical aspect of this maintenance is verifying the integrity of the mechanical sealing system.Due to the lack of an evaluat... Nuclear reactor coolant pumps require frequent maintenance to ensure operational safety.One critical aspect of this maintenance is verifying the integrity of the mechanical sealing system.Due to the lack of an evaluation criteria and an incomplete understanding of how end-face defects lead to failure,defective mechanical seals are often replaced empirically,which not only contributes to economic losses but also poses risks to reactor safety.To reveal the mechanism by which surface defects affect sealing performance,this study proposes a classification method for end-face defects based on the analysis of approximately one hundred used mechanical seals.A defect characterization model was established by extracting key features of the observed defects.The influence of these defects on sealing performance was analyzed using a liquid-thermal-solid coupling model.Changes in sealing gap,leakage rates,and film stiffness with respect to defect size,location,and other characteristics are discussed.This work contributes to a deeper understanding of defect failure mechanisms.These results can serve as a reference for evaluating defective seals. 展开更多
关键词 End-face defects Mechanical seals Liquid-thermal-solid coupling model Nuclear reactor coolant pumps
在线阅读 下载PDF
Study on Temperature Field Distribution of Hydraulic Motor Pump and Heat Dissipation Simulation of Flow-Solid-Heat Coupled with Spoiler Cooling Device
6
作者 Geqiang Li Kai Wang +3 位作者 Juntao Liu Zhengyang Han Shuai Wang Donglin Li 《Frontiers in Heat and Mass Transfer》 2026年第1期120-139,共20页
To explore the distribution law of the temperature field in the motor pump and the influence of the fanshaped DC channel with spoiler in the pump housing on its heat dissipation performance.This study takes the arc-ge... To explore the distribution law of the temperature field in the motor pump and the influence of the fanshaped DC channel with spoiler in the pump housing on its heat dissipation performance.This study takes the arc-gear type hydraulicmotor pump as the research object.In COMSOL,a coupled heat transfer simulationmodel of themotor pump’s fluid-solid coupling is established,and the internal temperature field characteristics are analyzed.To improve the heat dissipation effect of the motor pump,it is proposed to arrange spoiler in the fan-shaped DC channel of the pump housing to enhance heat dissipation.Three types of spoilers,namely,wing-shaped,inclined rectangle-shaped,and wave-shaped,are designed.The simulation results show that when the motor pump operates under rated conditions,due to the poor heat dissipation environment inside the motor pump,the high-temperature areas of the motor pump are concentrated in the rotor and permanent magnet parts.After arranging the spoiler,the turbulent kinetic energy and vorticity in the fan-shaped DC channel of the pump housing are significantly enhanced.All three spoiler structures can reduce the maximum temperature of each component of the motor.According to the comprehensive performance evaluation criterion(PEC),the inclined rectangle-shaped structure has the best comprehensive heat transfer performance(PEC=1.114),while the wave-shaped structure has higher heat transfer efficiency but greater pressure loss.The wing-shaped structure has relatively limited enhancement effect on heat dissipation.This study systematically quantifies the influence of different spoiler structures on heat dissipation performance and flowresistance characteristics,providing a solution for enhancing the heat dissipation of the motor pump. 展开更多
关键词 Motor pump fluid-solid coupling heat dissipation performance SPOILER enhancing the heat dissipation
在线阅读 下载PDF
基于Pumplinx的核电站给水泵三维流场仿真
7
作者 段程豫 《价值工程》 2026年第2期106-108,共3页
本文基于PumpLinx平台构建核电站给水泵全三维瞬态流场模型,采用分层网格与SST k-ω湍流模型耦合求解,揭示设计工况及事故序列下多物理场耦合机制。研究表明:外特性曲线在特定流量比时效率达极值,超流量工况扬程断裂源于叶轮前缘空化阻... 本文基于PumpLinx平台构建核电站给水泵全三维瞬态流场模型,采用分层网格与SST k-ω湍流模型耦合求解,揭示设计工况及事故序列下多物理场耦合机制。研究表明:外特性曲线在特定流量比时效率达极值,超流量工况扬程断裂源于叶轮前缘空化阻塞;子午面分析显示空化核心区集中于诱导轮吸力面及轮缘间隙,与低压区显著重合;高湍流动能分布于级间过渡段,主因几何失配诱发流动分离。研究成果为核电站多级给水泵的空化抑制与结构优化提供了高置信度仿真设计依据。 展开更多
关键词 给水泵 pumplinx 空化阻塞 子午面流场 气相分布 湍流模型
在线阅读 下载PDF
Construction and realization of the knowledge base and inference engine of an IDSS model for air-conditioning cooling/heating sources selection
8
作者 刘颖 王如竹 +1 位作者 李云飞 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2003年第2期136-141,共6页
The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowle... The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building. 展开更多
关键词 air-conditionING cooling/heating sources intelligent decision support system knowledge base inference engine
在线阅读 下载PDF
Application of water loop variable refrigerant flow air-conditioning system in large-scale buildings in northern China
9
作者 孙婷婷 倪龙 +1 位作者 姚杨 马最良 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期197-200,共4页
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va... A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system. 展开更多
关键词 variable refrigerant flow air-conditioning system water loop large-scale building
在线阅读 下载PDF
Genetic Optimization Algorithm of PID Decoupling Control for VAV Air-Conditioning System 被引量:4
10
作者 王江江 安大伟 +1 位作者 张春发 荆有印 《Transactions of Tianjin University》 EI CAS 2009年第4期308-314,共7页
Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multiv... Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multivariable decoupling PID controller is designed for VAV air-conditioning system. Diagonal matrix decoupling method is employed to eliminate the coupling between the loop of supply air temperature and that of thermal-space air temperature. The PID controller parameters are optimized by means of an improved genetic algorithm in floating point representations to obtain better performance. The population in the improved genetic algorithm mutates before crossover, which is helpful for the convergence. Additionally the micro mutation algorithm is proposed and applied to improve the convergence during the later evolution. To search the best parameters, the optimized parameters ranges should be amplified 10 times the initial ideal parameters. The simulation and experiment results show that the decoupling control system is effective and feasible. The method can overcome the strong coupling feature of the system and has shorter governing time and less over-shoot than non-optimization PID control. 展开更多
关键词 genetic algorithm decoupling control PID control variable air volume air-conditioning system
在线阅读 下载PDF
Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort 被引量:3
11
作者 刘红 马小磊 高亚峰 《Journal of Central South University》 SCIE EI CAS 2009年第S1期6-11,共6页
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three... To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes. 展开更多
关键词 air-conditionING TEMPERATURE thermal COMFORT air-conditionER energy consumption NEUTRAL TEMPERATURE acceptable TEMPERATURE
在线阅读 下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
12
作者 TANG Wen-wu WANG Han-qing 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-conditioning refrigerating machine condense heat entropy evaluation LS-SVM
在线阅读 下载PDF
Selection of Weather Parameters for Air-Conditioning System Design for Buildings with Long Thermal Lag 被引量:1
13
作者 GE Lian-feng LEI Ming CHEN You-ming 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期79-82,共4页
Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling lo... Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant. 展开更多
关键词 building construction thermal lag system capacity design weather data air-conditionING
在线阅读 下载PDF
Auto-Tuning Parameters of Fractional PID Controller Design for Air-Conditioning Fan Coil Unit 被引量:2
14
作者 Ll Shaoyong WANG Duo +2 位作者 HAN Xilian CHENG Kang ZHChunrun 《Journal of Shanghai Jiaotong university(Science)》 EI 2021年第2期186-192,共7页
The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintai... The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintain a steady indoor temperature in summer and winter,the control quality cannot meet the related requirements of air-conditioning automation,such as large overshoot,large steady state error.long regulating time,etc.In view of these factors,this paper develops a fractional order PID controller to deal with such problem associated with FCU.Then,by varving mutation factor and crossover rate of basic differential evolution algorithmadaptivelv,a modified differential evolution algorithm(MDEA)is designed to tune the satisfactory values of five parameters of indoor temperature fractional order PID controller.This fractional order PID coutrol system is configured and the corresponding mumerical simulation is conducted by means of MATLAB software.The results indicate that the proposed fractional order PID control svstem and MDEA are reliable and the related control performance indexes meet with the related requirements of comfortable air-conditioning design and control criteria. 展开更多
关键词 air-conditioning fan coil unit(FCU) fractional order PID control modified differential evolution algorithm(MDEA) auto-tuning parameters of controller
原文传递
The Experiment and Simulation of Solid Desiccant Dehumidification for Air-Conditioning System in a Tropical Humid Climate 被引量:1
15
作者 Juntakan Taweekun Visit Akvanich 《Engineering(科研)》 2013年第1期146-153,共8页
The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different ... The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD). 展开更多
关键词 SOLID DESICCANT DEHUMIDIFICATION air-conditionING System TROPICAL Humid CLIMATE
在线阅读 下载PDF
Experimental Study of Energy-Saving Air-Conditioner with Hot Water
16
作者 CHEN Jian-bo,CHEN Dan,LU Ying(University of Shanghai for Science and Technology,Shanghai,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期75-78,共4页
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in seri... Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters. 展开更多
关键词 air-conditionING water HEATERS energy CONSERVATION heat pump systems thermal efficiency
在线阅读 下载PDF
An Energy-Saving Control Strategy on Central Air-Conditioning System 被引量:1
17
作者 Sheng Xing 1 , Yin Juan 2 , Shang Jingfu 3 , Yu Yang 4 , Wu Zhangxian 5 1. State Grid Information & Telecommunication Co., Ltd. 2. China Huadian Finance Corporation Limited 3. State Grid AC Engineering Construction Company 4. Northeast China Electric Power Dispatching & Communication Center 5. North China Electric Power University 《Electricity》 2011年第4期62-66,共5页
An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con... An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy. 展开更多
关键词 central air-conditioning predictive control energy saving time-delay system simulated annealing
在线阅读 下载PDF
煤矿排水工具“pump”(泵)在近代中国的译入与传播
18
作者 周宁 徐礼静 《安徽理工大学学报(社会科学版)》 2025年第6期87-93,共7页
煤矿排水是煤矿开采过程中的关键环节。自晚清洋务运动时期起,近代中国煤炭开采开始引入机器,其中西方制造的“蒸汽泵”成为当时煤矿排水采用的主要设备之一。文章在追溯我国矿山排水工具发展史的基础上,分析英语词汇“pump”在近代中... 煤矿排水是煤矿开采过程中的关键环节。自晚清洋务运动时期起,近代中国煤炭开采开始引入机器,其中西方制造的“蒸汽泵”成为当时煤矿排水采用的主要设备之一。文章在追溯我国矿山排水工具发展史的基础上,分析英语词汇“pump”在近代中国的译入与传播过程,发现通过语义符码的跨文化重构,“pump”在汉语语境中完成了由“恒升车”“抽水筒”“唧筒”“帮浦”到“泵”的符号嬗变。这种基于汉语能指系统的概念整合,构建起技术知识本土化的知识再生产机制,使西方机械的技术原理得以准确转译,从语言层面消弭了技术传播的认知鸿沟。探究“pump”一词的汉译演变,既构筑起中西技术对话的知识桥梁,又揭示出晚清至民国时期知识精英在吸纳西方工业文明过程中,为打破语言障碍所采用的创造性策略。 展开更多
关键词 煤矿排水 技术概念 译入 传播
在线阅读 下载PDF
Application of Dual Throttling Air-Conditioning System to Explosion-Proof Frequency Converter
19
作者 张于峰 高岩 盛颖 《Transactions of Tianjin University》 EI CAS 2015年第2期95-103,共9页
An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study inv... An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study investigated the feasibility and benefits of explosion-proof dual throttling cooling and dehumidification air-conditioning system applied to the explosion-proof frequency converter. The physical model of dual throttling air-conditioning system was established and its performance parameter was described by mathematical method. The design calculation of the system has also been done. The experimental result showed that the system reached the steady state at the refrigeration mode after running 45 min, and the maximum internal temperature of the flame-proof cavity was 31.0 ℃. The system reached the steady state at the dehumidification mode after running 37 min. The maximum internal relative humidity and temperature of the flame-proof cavity were 33.4% and 36.3 ℃, respectively. Therefore, the proposed system had excellent ability of heat dissipation and avoided internal dewing. Compared with water cooling system, it was more energy-saving and economical. The airflow field of dual throttling air-conditioning system was also studied by CFD simulation. It was found that the result of CFD numerical simulation was highly consistent with the experimental data. 展开更多
关键词 EXPLOSION-PROOF CONVERTER DUAL throttling air-conditionING CFD energy SAVING heat DISSIPATION dewing
在线阅读 下载PDF
Application of Fuzzy Comprehensive Evaluation to Air-conditioning Competitive Power Analysis
20
作者 LU Congda LIU Gaojin +1 位作者 JIANG Shaofei LV Chaoqun 《武汉理工大学学报》 CAS CSCD 北大核心 2006年第S2期463-467,共5页
As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment(QFD),cus-tomer requirements should be understood and the product competitive power be analyzed as exactly as possibl... As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment(QFD),cus-tomer requirements should be understood and the product competitive power be analyzed as exactly as possible for new product de-signing.Lots of information in the process of this research is fuzzy and uncertain,but traditional QFD can not deal with it well.Fuzzy theory can solve the problem.So a fuzzy model for analyzing product competitive power is formulated in this paper to im-prove traditional QFD,after that it is applied to analyze air-conditioning competitive power.When air-conditioning competitive power is analyzed using this model,firstly the importance weight of the customer requirements o fair-conditioning is determined us-ing the Analytic Hierarchy Process(AHP)weighting process,then air-conditloning competitive power is evaluated using fuzzy comprehensive evaluation.It is proved that the model is feasible and has good applicability. 展开更多
关键词 air-conditioning competitive power QFD AHP fuzzy comprehensive evaluation