Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increas...Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increasing in a data center. Thus, the heat density in a data center is much higher than that of usual offices. And typically, almost 40% of the total power consumption is used for cooling servers in a data center. Thus, cooling effectiveness is one of the most important factors in evaluating the value of the data center. The data center taken up in this paper is located in Ishikari, where is a cold district in Japan. Using the cool outdoor air for cooling servers helps us to cut the power consumption for cooling. This paper first assesses the efficiency of Ishikari data center measuring the temperature of seven parts in a building where the cooling air flowing. Second, this paper describes the most efficient method for the operation and estimates 1.11 of PUE (power usage effectiveness).展开更多
The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storag...The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storage capacity and good thermal insulation, so the metal temperature of first stage of HP cylinder (FSMTI) may reach 400-450℃ after shut down and it takes 7-8 days to cool to 150℃ by natural cooling, Now with a forced cooling system the cooling time may be reduced to 40 hours, so that the turbine may be opened for repair work in about 5-6 days. The cooling system for #2 unit and test procedure are briefly described below.展开更多
Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfe...Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfer coefficient and pressure drop are displayed with variable structural parameters of fins and inlet velocities of cooling air.Within the range of simulation,TWFC has the best comprehensive performance when inlet velocity vin=4-10 m/s.Compared with those of straight fins,the simulation results reveal that the triangular wavy fin channels are of higher heat transfer performances especially with the fin structural parameters of fin-height Fh=9.0 mm,fin-pitch Fp=2.5-3.0 mm,fin-wavelength λ=14.0-17.5 mm and fin-wave-amplitude A=1.0-1.2 mm.The correlations of both heat transfer factor and friction factor are presented,and the deviations from the experimental measurements are within 20%.展开更多
With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the ...With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.展开更多
This paper discusses air forced convection heat transfer from inline protruding elements arranged in eight rows. The streamwise and spanwise spacings between elements were varied using a splitter plate that can be pos...This paper discusses air forced convection heat transfer from inline protruding elements arranged in eight rows. The streamwise and spanwise spacings between elements were varied using a splitter plate that can be positioned at three different modular configurations. A set of empirical formulas waspresented to correlate the experimental data for the design of air cooling systems. Arrays of components with one odd-size module have been tested also. Experimental results show that blocks near the entrance and behind the odd-size module have improved performance compared with uniform arrangements. Accordingly, temperature sensitive components are suggested to be arranged in these locations.展开更多
Green cooling is an important technology in green manufacturing. In the way of jetting, cooling airflo-w in used in the experiments of metal material cutting, by comparison of the changes of some technological factors...Green cooling is an important technology in green manufacturing. In the way of jetting, cooling airflo-w in used in the experiments of metal material cutting, by comparison of the changes of some technological factors, such as cutting heat, surface finish, in the process of jet cooling, pour cooling and natural cooling, we can draiv the conclusion that air jet cooling has a better cooling effect and green function. It can be 'widely used in both traditional and automatic green manufacturing.展开更多
The development and mechanical performances of new type air-cooled Mn series bainitic steels including granular bainitic steels, FGBA/BG duplex steels, CFB/M duplex steels, medium carbon bainite/martensite steels, cas...The development and mechanical performances of new type air-cooled Mn series bainitic steels including granular bainitic steels, FGBA/BG duplex steels, CFB/M duplex steels, medium carbon bainite/martensite steels, cast bainitic steels invented by the authors are summarized. The novel series of bainitic steels are alloyed with Mn, and several series bainitic duplex microstructures can be easily obtained under the condition of air cooling through unique composition design. The invented idea, the principle of alloying design, the strengthening mechanism, and the evolution of the microstructure of new type air cooled Mn series bainitic steels are presented. Furthermore, the applications in different fields of these Mn series air cooled bainitic steels with different strength level are also introduced. It is suggested that the significance of the development of the air cooled Mn series bainitic steel can be summarized as follows: reducing costs of both raw materials and production; good combination of strength and toughness; self-hardening with high bainitic hardenahility by air cooling from hot working without additional quenching-tempering treatment or quenching procedure; large savings in energy resources; and reduced environmental pollution.展开更多
Friction stir welding (FSW) with water cooling and air cooling was used to weld 2219-T62 aluminum alloy joints with a thickness of 20 mm. The effect of cooling conditions on the corrosion resistance of joints in 3.5% ...Friction stir welding (FSW) with water cooling and air cooling was used to weld 2219-T62 aluminum alloy joints with a thickness of 20 mm. The effect of cooling conditions on the corrosion resistance of joints in 3.5% NaCl solution was investigated using the open circuit potential (OCP), the potentiodynamic polarization, and the corrosion morphology after immersing for different time. And the precipitates distribution was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results reveal that the weld nugget zone (WNZ) owning positive potential, lower corrosion current density and fine and uniform precipitates, is much more difficult to corrode than the heat affected zone (HAZ) and the base metal (BM). Compared with air-cooled joint, the water-cooled joint has better corrosion resistance. In addition, the results of microstructure observation show that the potential, distribution and size of second phase particles determine the corrosion resistance of FSW AA2219 alloy joints in chlorine-contained solution.展开更多
Based on ANSYS, an analytical model was established for H beam during controlled cooling. The tempera-ture fields during controlled cooling and air cooling were analyzed and the microstructure and mechanical propertie...Based on ANSYS, an analytical model was established for H beam during controlled cooling. The tempera-ture fields during controlled cooling and air cooling were analyzed and the microstructure and mechanical properties for different parts of H-beam were discussed in detail. After the H-beam was controlled cooled for 4.5 s, its mean surface temperature decreased from 850 to 460 ℃, and the lowest and the highest temperatures were measured at edge of flange and at R corner, respectively. Whereas, for the H-beam air cooled for 30 s, the mean temperature at R corner and web was 700 and 540 ℃, respectively. The microstructures for different parts of H-beam consisted of ferrite and pearlite, and the grain size at R corner was coarser than those at flange and web. The difference of yield and tensile strengths of web, flange and R corner was within 30 MPa, and the elongation was similar. The changes of microstructure were in good agreement with that of temperature field. In addition, the results show that the uni formity of microstructure and mechanical properties can be improved by increasing water flow rate at R corner.展开更多
This paper implemented cooling configuration design on certain gas turbine HP rotor using parameterized method.It is convenient for complicated gas turbine blade modeling using parameters and also benefit for the geom...This paper implemented cooling configuration design on certain gas turbine HP rotor using parameterized method.It is convenient for complicated gas turbine blade modeling using parameters and also benefit for the geometry modify in later period.Parameterized modeling is the foundation of air cooling turbine blade design method engineering application.Mesh quality can be awarded when generated complicated cooling configuration blade grids,and also the increase of calculation error can arise by many mesh blocks.Film cooling and serpentine passage can effectively enhance the cooling effectiveness and protect blade.展开更多
This paper studied a certain blade with ten radial cooling holes which employed conjugate heat transfer method. The cooling air entered the cooling channel from the bottom of the blade and went out from the top, it wa...This paper studied a certain blade with ten radial cooling holes which employed conjugate heat transfer method. The cooling air entered the cooling channel from the bottom of the blade and went out from the top, it was not ejected into the main flow. This paper used different numerical conditions including different turbulence models,turbulence intensities,thermal conduction coefficients and the influence on fluid property via temperature variation. The temperature distribution and pressure distribution of the blade were compared with experimental data. The results show that the numerical results using different turbulence models are almost identical to experimental data even little deviation occurs at shock wave location. The trends of temperature distribution under different numerical conditions are coincident to experimental data,especially Reynolds stress turbulence model. It can be concluded that anisotropic turbulence models can simulate the transition from laminar to turbulence,and the influence of turbulence intensity on laminar region and transition region is more than that on developed turbulent region.展开更多
Temperature is critical to maintaining seed viability under long-term storage conditions. It has been common practice to use refrigeration systems to maintain required storage temperatures. A seed repository construct...Temperature is critical to maintaining seed viability under long-term storage conditions. It has been common practice to use refrigeration systems to maintain required storage temperatures. A seed repository constructed in permafrost in Yakutsk, Russia is the first seed storage facility that relies solely on natural cold. This paper describes the design and performance of the cooling system of the repository. An innovative aspect of the cooling system is that it utilizes the patterns of temperature wave propagation in permafrost. Predicted and measured ground temperatures for the first year of operation are presented and analyzed. Results indicate that convection air cooling systems can be used to control the temperature regime in underground facilities in permafrost.展开更多
High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial asp...High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial aspects of the AC-cooled greenhouse as compared to the evaporative cooled(EV-cooled)greenhouse in winter and summer seasons.Two quonset single-span prototype greenhouses were built in the Agriculture Experiment Station of Sultan Qaboos University,Oman,with dimensions of 6.0 m long and 3.0 m wide.The AC-cooled greenhouse was covered by a rockwool insulated polyethylene plastic sheet and light emitting diodes(LED)lights were used as a source of light,while the EV-cooled greenhouse was covered by a transparent polyethylene sheet and sunlight was used as light source.Three cultivars of high-value lettuce were grown for experimentation.To evaluate the technical efficiency of greenhouse performance,we conducted measures on land use efficiency(LUE),water use efficiency(WUE),gross water use efficiency(GWUE)and energy use efficiency(EUE).Financial analysis was conducted to compare the profitability of both greenhouses.The results showed that the LUE in winter were 10.10 and 14.50 kg/m^(2) for the AC-and EV-cooled greenhouses,respectively.However,the values reduced near to 6.80 kg/m^(2) in both greenhouses in summer.The WUE of the AC-cooled greenhouse was higher than that of the EV-cooled greenhouse by 3.8%in winter and 26.8%in summer.The GWUE was used to measure the total yield to the total greenhouse water consumption including irrigation and cooling water;it was higher in the AC-cooled greenhouse than in the EV-cooled greenhouse in both summer and winter seasons by almost 98.0%–99.4%.The EUE in the EV-cooled greenhouse was higher in both seasons.Financial analysis showed that in winter,gross return,net return and benefit-to-cost ratio were better in the EVcooled greenhouse,while in summer,those were higher in the AC-cooled greenhouse.The values of internal rate of return in the AC-and EV-cooled greenhouses were 63.4%and 129.3%,respectively.In both greenhouses,lettuce investment was highly sensitive to changes in price,yield and energy cost.The financial performance of the AC-cooled greenhouse in summer was better than that of the EV-cooled greenhouse and the pattern was opposite in winter.Finally,more studies on the optimum LED light intensity for any particular crop have to be conducted over different growing seasons in order to enhance the yield quantity and quality of crop.展开更多
Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind...Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind power generation and other fields. This paper introduces the basic structure of hybrid excitation motor with modular stator, and analyzes the operation principle of hybrid excitation motor. The cooling structure of the water-cooled plate is designed, and the effects of the thickness of the water-cooled plate and the number of water channels in the water-cooled plate on the heat dissipation capacity of the water-cooled plate are analyzed by theoretical and computational fluid dynamics methods. The effects of different water cooling plate structures on water velocity, pressure drop, water pump power consumption and heat dissipation capacity were compared and analyzed. The influence of different inlet flow velocity on the maximum temperature rise of each part of the motor is analyzed, and the temperature of each part of the motor under the optimal water flow is analyzed. The influence of the traditional spiral water jacket cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of the motor components is compared and analyzed. The results show that the water-cooled plate cooling structure is more suitable for the modular stator motor studied in this paper. Based on the water-cooled plate cooling structure, the air-water composite cooling structure is designed, and the effects of the air-water composite cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of each component of the motor are compared and analyzed. The results show that the maximum temperature rise of each component of the motor is reduced under the air-water composite cooling structure.展开更多
The results researching of structural schemes cooling for turbines of aircraft bypass gas turbine engines are presented.A new scheme of supplying cooling air to the high-pressure turbine working blades is proposed.The...The results researching of structural schemes cooling for turbines of aircraft bypass gas turbine engines are presented.A new scheme of supplying cooling air to the high-pressure turbine working blades is proposed.The front cavity of the nozzle and rotor blades is cooled continuously,regardless of the engine’s operating mode.The air for cooling the working blade of the high-pressure turbine is supplied by the transit tube through the vane from the cavity,which is located in front of the place where is supply locking,which ensures constant boost of the blade front cavity.To eliminate the heating from the turbine disk and centrifugal pumping,the swirling device is installed directly under the blade lock,where the supply of cooling air to the cavity is organized.The turbine disk is cooled by the second row of swirling device with air taken from the secondary zone of the combustion chamber.The swirling devices rows are separated by brush seal and labyrinth.The higher efficiency of the brushes,the location of the swirling device cooling the disk under the labyrinth in the upper part of the disk,the decrease in the number of labyrinth teeth and,as a result,the pressure drop across the labyrinth between the disk cooling cavity and the dummy cavity eliminates heating air cooling blade because the main part of the hotter air is to be directed down the disk and,further,along the shaft of the high-pressure rotor into the dummy cavity.展开更多
In recent years,due to the rapid increase in the number of vehicles in the world,the traditional vehicles using gasoline or diesel as energy have led to serious air pollution and energy depletion.It is urgent to devel...In recent years,due to the rapid increase in the number of vehicles in the world,the traditional vehicles using gasoline or diesel as energy have led to serious air pollution and energy depletion.It is urgent to develop practical clean energy vehicles.The performance of electric vehicle depends on the power battery pack.The working temperature of the battery pack has a great impact on the performance of the battery,so it is necessary to carry out thermal management on the battery pack.Taking a lithium-ion battery as the research object,the temperature field of the battery pack in the charge and discharge state is simulated and analyzed by using CFD simulation software in the way of air cooled heat dissipation,so as to understand the influencing factors of uneven temperature field.At the same time,the development trend of battery temperature can be well predicted through simulation,so as to provide theoretical basis for the design of battery pack.展开更多
Nowadays,new energy technologies are developing rapidly,energy storage systems are widely used,and lithium-ion batteries occupy a dominant position among them.Therefore,it is also very important to ensure their perfor...Nowadays,new energy technologies are developing rapidly,energy storage systems are widely used,and lithium-ion batteries occupy a dominant position among them.Therefore,it is also very important to ensure their performance,safety and service life through thermal management technology.In this paper,the causes of thermal runaway of lithium batteries are reviewed firstly,and three commonly used thermal management technologies,namely,air cooling,liquid cooling and phase change material cooling,are compared according to relevant literature in recent years.Air cooling technology has been widely studied because of its simple structure and low cost,but its temperature control effect is poor.Liquid cooling technology takes away heat through the circulation of liquid medium,which has a good cooling effect,but the system is relatively complex.Phase change material(PCM)cooling technology uses the high latent heat of PCM to absorb and re-lease heat,which can effectively reduce the peak temperature of a battery and improve the temperature uniformity,but the low thermal conductivity and liquid leakage are its main problems.To sum up,lithium-ion battery thermal management technology is moving towards a more efficient,safer and cost-effective direction.Coupled cooling systems,such as those combining liquid cooling and phase change material cooling,show great potential.Future research will continue to explore new materials and technologies to meet the growing demands of society and the market for lithium-ion battery perfor-mance and safety.展开更多
The alloying design idea,strengthening-toughening mechanism,microstructure,mechanical performances,development and application in China of new type Mn-series bainitic steels are introduced.Mn-series air-cooling bainit...The alloying design idea,strengthening-toughening mechanism,microstructure,mechanical performances,development and application in China of new type Mn-series bainitic steels are introduced.Mn-series air-cooling bainitic steels including granular bainitic steels,FGBA/BG duplex steels,CFB/M duplex steels,medium carbon bainite/martensite steels,cast bainitic steels are presented.The invented idea mechanical performances,development and application of second generation of Mn-series bainitic steels,i.e.water quenching Mn-series bainitic steels invented by the authors newly are introduced.The water quenching Mn-series bainitic steels cover severe series steels containing ultra-low carbon,low-low carbon,medium-low carbon,and high-low carbon content etc,which can reduce the amount of alloying content,increase hardening capability and improve weldability.It should be pointed out that the application of both air cooling and water quenching Mn-series bainitic steels are complementary and mutually reinforcing,and the new type Mn-series bainitic steels can meet the performance requirements of most steels used in engineering structure.Some newest technologies of Mn-series bainitic steels in China are discussed in this paper.It is suggested that the significance of the development of the Mn-series bainitic steels can be summarized as:significantly reducing costs of both raw materials and production;good combination of strength and toughness;excellent weldability;simple procedure;large savings in energy resources and reduced environmental pollution.展开更多
In order to solve the problems of high temperature and inconsistency in the operation of electric vehicle( EV) battery pack,computational fluid dynamics( CFD) simulation method is used to simulate and optimize the...In order to solve the problems of high temperature and inconsistency in the operation of electric vehicle( EV) battery pack,computational fluid dynamics( CFD) simulation method is used to simulate and optimize the heat dissipation of battery pack. The heat generation rate at different discharge magnifications is identified by establishing the heat generation model of the battery. In the forced air cooling mode,the Fluent software is used to compare the effects of different inlet and outlet directions,inlet angles,outlet angles,outlet sizes and inlet air speeds on heat dissipation. The simulation results show that the heat dissipation effect of the structure with the inlet and outlet on the same side is better than that on the different sides; the appropriate inlet angle and outlet width can improve the uniformity of temperature field; the increase of the inlet speed can improve the heat dissipation effect significantly. Compared with the steady temperature field of the initial structure,the average temperature after structure optimization is reduced by 4. 8℃ and the temperature difference is reduced by 15. 8℃,so that the battery can work under reasonable temperature and temperature difference.展开更多
The effects of final air cooling temperature on the microstructure and mechanical properties of hot rolled 0.2C-1.9Mn-0.5Si-0.08P TRIP steel were studied by utilizing OM,SEM,TEM and tensile tests.Experimental results ...The effects of final air cooling temperature on the microstructure and mechanical properties of hot rolled 0.2C-1.9Mn-0.5Si-0.08P TRIP steel were studied by utilizing OM,SEM,TEM and tensile tests.Experimental results showed that in the multiphase microstructure of the investigated steel when the finish rolling temperature was about 820℃and the final air cooling temperature was in the range of 630-700℃,the grain size of most of ferrite was finer(about 4μm)and which had higher dislocation density,the bainite packets had chaotic orientations and lath boundaries of bainite were not quite straight,the retained austenite distributed in the ferrite grain boundaries or triradius was fine and dispersive,and their grain size was about 0.4-1.9μm.With increasing the amount of ferrite,the volume fraction of retained austenite had a slight decrease.When the final air cooling temperature was 630℃,the steel had excellent mechanical properties,which was characterized by combination of continuous yielding,high strength(about 796 MPa)and high elongation(22.7%)as well as low yield/strength ratio(0.58);when the final air cooling temperature increased to 700℃,the matrix structure was bainite packets and the comprehensive properties were deteriorated.展开更多
文摘Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increasing in a data center. Thus, the heat density in a data center is much higher than that of usual offices. And typically, almost 40% of the total power consumption is used for cooling servers in a data center. Thus, cooling effectiveness is one of the most important factors in evaluating the value of the data center. The data center taken up in this paper is located in Ishikari, where is a cold district in Japan. Using the cool outdoor air for cooling servers helps us to cut the power consumption for cooling. This paper first assesses the efficiency of Ishikari data center measuring the temperature of seven parts in a building where the cooling air flowing. Second, this paper describes the most efficient method for the operation and estimates 1.11 of PUE (power usage effectiveness).
文摘The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storage capacity and good thermal insulation, so the metal temperature of first stage of HP cylinder (FSMTI) may reach 400-450℃ after shut down and it takes 7-8 days to cool to 150℃ by natural cooling, Now with a forced cooling system the cooling time may be reduced to 40 hours, so that the turbine may be opened for repair work in about 5-6 days. The cooling system for #2 unit and test procedure are briefly described below.
基金Project(50976022) supported by the National Natural Science Foundation of ChinaProject(BY2011155) supported by the Provincial Science and Technology Innovation and Transformation of Achievements of Special Fund Project of Jiangsu Province,China
文摘Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfer coefficient and pressure drop are displayed with variable structural parameters of fins and inlet velocities of cooling air.Within the range of simulation,TWFC has the best comprehensive performance when inlet velocity vin=4-10 m/s.Compared with those of straight fins,the simulation results reveal that the triangular wavy fin channels are of higher heat transfer performances especially with the fin structural parameters of fin-height Fh=9.0 mm,fin-pitch Fp=2.5-3.0 mm,fin-wavelength λ=14.0-17.5 mm and fin-wave-amplitude A=1.0-1.2 mm.The correlations of both heat transfer factor and friction factor are presented,and the deviations from the experimental measurements are within 20%.
基金Financial supports for this project, provided by the key program supported by the National Natural Science Foundation of China(No. 51134005)the Doctoral Scientific Fund Project of the Ministry of Education of China (No. 20120023120004), are gratefully acknowledged
文摘With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.
文摘This paper discusses air forced convection heat transfer from inline protruding elements arranged in eight rows. The streamwise and spanwise spacings between elements were varied using a splitter plate that can be positioned at three different modular configurations. A set of empirical formulas waspresented to correlate the experimental data for the design of air cooling systems. Arrays of components with one odd-size module have been tested also. Experimental results show that blocks near the entrance and behind the odd-size module have improved performance compared with uniform arrangements. Accordingly, temperature sensitive components are suggested to be arranged in these locations.
文摘Green cooling is an important technology in green manufacturing. In the way of jetting, cooling airflo-w in used in the experiments of metal material cutting, by comparison of the changes of some technological factors, such as cutting heat, surface finish, in the process of jet cooling, pour cooling and natural cooling, we can draiv the conclusion that air jet cooling has a better cooling effect and green function. It can be 'widely used in both traditional and automatic green manufacturing.
基金Item Sponsored by National Basic Research Programof China(2004CB619105)
文摘The development and mechanical performances of new type air-cooled Mn series bainitic steels including granular bainitic steels, FGBA/BG duplex steels, CFB/M duplex steels, medium carbon bainite/martensite steels, cast bainitic steels invented by the authors are summarized. The novel series of bainitic steels are alloyed with Mn, and several series bainitic duplex microstructures can be easily obtained under the condition of air cooling through unique composition design. The invented idea, the principle of alloying design, the strengthening mechanism, and the evolution of the microstructure of new type air cooled Mn series bainitic steels are presented. Furthermore, the applications in different fields of these Mn series air cooled bainitic steels with different strength level are also introduced. It is suggested that the significance of the development of the air cooled Mn series bainitic steel can be summarized as follows: reducing costs of both raw materials and production; good combination of strength and toughness; self-hardening with high bainitic hardenahility by air cooling from hot working without additional quenching-tempering treatment or quenching procedure; large savings in energy resources; and reduced environmental pollution.
基金Project (51405392) supported by the National Natural Science Foundation of ChinaProject (2019T120954) supported by the China Postdoctoral Science Foundation+1 种基金Project (3102019MS0404) supported by Fundamental Research Funds for the Central Universities, ChinaProject (2018BSHQYXMZZ31) supported by the Postdoctoral Science Foundation of Shaanxi Province, China。
文摘Friction stir welding (FSW) with water cooling and air cooling was used to weld 2219-T62 aluminum alloy joints with a thickness of 20 mm. The effect of cooling conditions on the corrosion resistance of joints in 3.5% NaCl solution was investigated using the open circuit potential (OCP), the potentiodynamic polarization, and the corrosion morphology after immersing for different time. And the precipitates distribution was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results reveal that the weld nugget zone (WNZ) owning positive potential, lower corrosion current density and fine and uniform precipitates, is much more difficult to corrode than the heat affected zone (HAZ) and the base metal (BM). Compared with air-cooled joint, the water-cooled joint has better corrosion resistance. In addition, the results of microstructure observation show that the potential, distribution and size of second phase particles determine the corrosion resistance of FSW AA2219 alloy joints in chlorine-contained solution.
基金Item Sponsored by National Science and Technology Support Project of China(2007BAE30B05)
文摘Based on ANSYS, an analytical model was established for H beam during controlled cooling. The tempera-ture fields during controlled cooling and air cooling were analyzed and the microstructure and mechanical properties for different parts of H-beam were discussed in detail. After the H-beam was controlled cooled for 4.5 s, its mean surface temperature decreased from 850 to 460 ℃, and the lowest and the highest temperatures were measured at edge of flange and at R corner, respectively. Whereas, for the H-beam air cooled for 30 s, the mean temperature at R corner and web was 700 and 540 ℃, respectively. The microstructures for different parts of H-beam consisted of ferrite and pearlite, and the grain size at R corner was coarser than those at flange and web. The difference of yield and tensile strengths of web, flange and R corner was within 30 MPa, and the elongation was similar. The changes of microstructure were in good agreement with that of temperature field. In addition, the results show that the uni formity of microstructure and mechanical properties can be improved by increasing water flow rate at R corner.
基金Sponsored by the National Natural Science Foundation of China(Grant No. 50476028)
文摘This paper implemented cooling configuration design on certain gas turbine HP rotor using parameterized method.It is convenient for complicated gas turbine blade modeling using parameters and also benefit for the geometry modify in later period.Parameterized modeling is the foundation of air cooling turbine blade design method engineering application.Mesh quality can be awarded when generated complicated cooling configuration blade grids,and also the increase of calculation error can arise by many mesh blocks.Film cooling and serpentine passage can effectively enhance the cooling effectiveness and protect blade.
基金Sponsored by the National Natural Science Foundation of China( Grant No. 50576017)
文摘This paper studied a certain blade with ten radial cooling holes which employed conjugate heat transfer method. The cooling air entered the cooling channel from the bottom of the blade and went out from the top, it was not ejected into the main flow. This paper used different numerical conditions including different turbulence models,turbulence intensities,thermal conduction coefficients and the influence on fluid property via temperature variation. The temperature distribution and pressure distribution of the blade were compared with experimental data. The results show that the numerical results using different turbulence models are almost identical to experimental data even little deviation occurs at shock wave location. The trends of temperature distribution under different numerical conditions are coincident to experimental data,especially Reynolds stress turbulence model. It can be concluded that anisotropic turbulence models can simulate the transition from laminar to turbulence,and the influence of turbulence intensity on laminar region and transition region is more than that on developed turbulent region.
文摘Temperature is critical to maintaining seed viability under long-term storage conditions. It has been common practice to use refrigeration systems to maintain required storage temperatures. A seed repository constructed in permafrost in Yakutsk, Russia is the first seed storage facility that relies solely on natural cold. This paper describes the design and performance of the cooling system of the repository. An innovative aspect of the cooling system is that it utilizes the patterns of temperature wave propagation in permafrost. Predicted and measured ground temperatures for the first year of operation are presented and analyzed. Results indicate that convection air cooling systems can be used to control the temperature regime in underground facilities in permafrost.
文摘High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial aspects of the AC-cooled greenhouse as compared to the evaporative cooled(EV-cooled)greenhouse in winter and summer seasons.Two quonset single-span prototype greenhouses were built in the Agriculture Experiment Station of Sultan Qaboos University,Oman,with dimensions of 6.0 m long and 3.0 m wide.The AC-cooled greenhouse was covered by a rockwool insulated polyethylene plastic sheet and light emitting diodes(LED)lights were used as a source of light,while the EV-cooled greenhouse was covered by a transparent polyethylene sheet and sunlight was used as light source.Three cultivars of high-value lettuce were grown for experimentation.To evaluate the technical efficiency of greenhouse performance,we conducted measures on land use efficiency(LUE),water use efficiency(WUE),gross water use efficiency(GWUE)and energy use efficiency(EUE).Financial analysis was conducted to compare the profitability of both greenhouses.The results showed that the LUE in winter were 10.10 and 14.50 kg/m^(2) for the AC-and EV-cooled greenhouses,respectively.However,the values reduced near to 6.80 kg/m^(2) in both greenhouses in summer.The WUE of the AC-cooled greenhouse was higher than that of the EV-cooled greenhouse by 3.8%in winter and 26.8%in summer.The GWUE was used to measure the total yield to the total greenhouse water consumption including irrigation and cooling water;it was higher in the AC-cooled greenhouse than in the EV-cooled greenhouse in both summer and winter seasons by almost 98.0%–99.4%.The EUE in the EV-cooled greenhouse was higher in both seasons.Financial analysis showed that in winter,gross return,net return and benefit-to-cost ratio were better in the EVcooled greenhouse,while in summer,those were higher in the AC-cooled greenhouse.The values of internal rate of return in the AC-and EV-cooled greenhouses were 63.4%and 129.3%,respectively.In both greenhouses,lettuce investment was highly sensitive to changes in price,yield and energy cost.The financial performance of the AC-cooled greenhouse in summer was better than that of the EV-cooled greenhouse and the pattern was opposite in winter.Finally,more studies on the optimum LED light intensity for any particular crop have to be conducted over different growing seasons in order to enhance the yield quantity and quality of crop.
基金supported by the National Natural Science Foundation of China (51907129)Project Supported by Department of Science and Technology of Liaoning Province (2021-MS-236)。
文摘Hybrid excitation synchronous motor has the advantages of uniform and adjustable electromagnetic field, wide speed range and high power density. It has broad application prospects in new energy electric vehicles, wind power generation and other fields. This paper introduces the basic structure of hybrid excitation motor with modular stator, and analyzes the operation principle of hybrid excitation motor. The cooling structure of the water-cooled plate is designed, and the effects of the thickness of the water-cooled plate and the number of water channels in the water-cooled plate on the heat dissipation capacity of the water-cooled plate are analyzed by theoretical and computational fluid dynamics methods. The effects of different water cooling plate structures on water velocity, pressure drop, water pump power consumption and heat dissipation capacity were compared and analyzed. The influence of different inlet flow velocity on the maximum temperature rise of each part of the motor is analyzed, and the temperature of each part of the motor under the optimal water flow is analyzed. The influence of the traditional spiral water jacket cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of the motor components is compared and analyzed. The results show that the water-cooled plate cooling structure is more suitable for the modular stator motor studied in this paper. Based on the water-cooled plate cooling structure, the air-water composite cooling structure is designed, and the effects of the air-water composite cooling structure and the water-cooled plate cooling structure on the maximum temperature rise of each component of the motor are compared and analyzed. The results show that the maximum temperature rise of each component of the motor is reduced under the air-water composite cooling structure.
文摘The results researching of structural schemes cooling for turbines of aircraft bypass gas turbine engines are presented.A new scheme of supplying cooling air to the high-pressure turbine working blades is proposed.The front cavity of the nozzle and rotor blades is cooled continuously,regardless of the engine’s operating mode.The air for cooling the working blade of the high-pressure turbine is supplied by the transit tube through the vane from the cavity,which is located in front of the place where is supply locking,which ensures constant boost of the blade front cavity.To eliminate the heating from the turbine disk and centrifugal pumping,the swirling device is installed directly under the blade lock,where the supply of cooling air to the cavity is organized.The turbine disk is cooled by the second row of swirling device with air taken from the secondary zone of the combustion chamber.The swirling devices rows are separated by brush seal and labyrinth.The higher efficiency of the brushes,the location of the swirling device cooling the disk under the labyrinth in the upper part of the disk,the decrease in the number of labyrinth teeth and,as a result,the pressure drop across the labyrinth between the disk cooling cavity and the dummy cavity eliminates heating air cooling blade because the main part of the hotter air is to be directed down the disk and,further,along the shaft of the high-pressure rotor into the dummy cavity.
文摘In recent years,due to the rapid increase in the number of vehicles in the world,the traditional vehicles using gasoline or diesel as energy have led to serious air pollution and energy depletion.It is urgent to develop practical clean energy vehicles.The performance of electric vehicle depends on the power battery pack.The working temperature of the battery pack has a great impact on the performance of the battery,so it is necessary to carry out thermal management on the battery pack.Taking a lithium-ion battery as the research object,the temperature field of the battery pack in the charge and discharge state is simulated and analyzed by using CFD simulation software in the way of air cooled heat dissipation,so as to understand the influencing factors of uneven temperature field.At the same time,the development trend of battery temperature can be well predicted through simulation,so as to provide theoretical basis for the design of battery pack.
基金supported by the National Natural Science Foundation of China(No.52001045).
文摘Nowadays,new energy technologies are developing rapidly,energy storage systems are widely used,and lithium-ion batteries occupy a dominant position among them.Therefore,it is also very important to ensure their performance,safety and service life through thermal management technology.In this paper,the causes of thermal runaway of lithium batteries are reviewed firstly,and three commonly used thermal management technologies,namely,air cooling,liquid cooling and phase change material cooling,are compared according to relevant literature in recent years.Air cooling technology has been widely studied because of its simple structure and low cost,but its temperature control effect is poor.Liquid cooling technology takes away heat through the circulation of liquid medium,which has a good cooling effect,but the system is relatively complex.Phase change material(PCM)cooling technology uses the high latent heat of PCM to absorb and re-lease heat,which can effectively reduce the peak temperature of a battery and improve the temperature uniformity,but the low thermal conductivity and liquid leakage are its main problems.To sum up,lithium-ion battery thermal management technology is moving towards a more efficient,safer and cost-effective direction.Coupled cooling systems,such as those combining liquid cooling and phase change material cooling,show great potential.Future research will continue to explore new materials and technologies to meet the growing demands of society and the market for lithium-ion battery perfor-mance and safety.
文摘The alloying design idea,strengthening-toughening mechanism,microstructure,mechanical performances,development and application in China of new type Mn-series bainitic steels are introduced.Mn-series air-cooling bainitic steels including granular bainitic steels,FGBA/BG duplex steels,CFB/M duplex steels,medium carbon bainite/martensite steels,cast bainitic steels are presented.The invented idea mechanical performances,development and application of second generation of Mn-series bainitic steels,i.e.water quenching Mn-series bainitic steels invented by the authors newly are introduced.The water quenching Mn-series bainitic steels cover severe series steels containing ultra-low carbon,low-low carbon,medium-low carbon,and high-low carbon content etc,which can reduce the amount of alloying content,increase hardening capability and improve weldability.It should be pointed out that the application of both air cooling and water quenching Mn-series bainitic steels are complementary and mutually reinforcing,and the new type Mn-series bainitic steels can meet the performance requirements of most steels used in engineering structure.Some newest technologies of Mn-series bainitic steels in China are discussed in this paper.It is suggested that the significance of the development of the Mn-series bainitic steels can be summarized as:significantly reducing costs of both raw materials and production;good combination of strength and toughness;excellent weldability;simple procedure;large savings in energy resources and reduced environmental pollution.
基金Supported by the National Natural Science Foundation of China(51507012)Beijing Nova Program(Z171100001117063)
文摘In order to solve the problems of high temperature and inconsistency in the operation of electric vehicle( EV) battery pack,computational fluid dynamics( CFD) simulation method is used to simulate and optimize the heat dissipation of battery pack. The heat generation rate at different discharge magnifications is identified by establishing the heat generation model of the battery. In the forced air cooling mode,the Fluent software is used to compare the effects of different inlet and outlet directions,inlet angles,outlet angles,outlet sizes and inlet air speeds on heat dissipation. The simulation results show that the heat dissipation effect of the structure with the inlet and outlet on the same side is better than that on the different sides; the appropriate inlet angle and outlet width can improve the uniformity of temperature field; the increase of the inlet speed can improve the heat dissipation effect significantly. Compared with the steady temperature field of the initial structure,the average temperature after structure optimization is reduced by 4. 8℃ and the temperature difference is reduced by 15. 8℃,so that the battery can work under reasonable temperature and temperature difference.
基金Fundamental Research Funds for the Central Universities(N090407001)National Key Project of Scientific and Technical Supporting Programs(2007BAE51B07)National Natural Science Foundation of China(50734001)
文摘The effects of final air cooling temperature on the microstructure and mechanical properties of hot rolled 0.2C-1.9Mn-0.5Si-0.08P TRIP steel were studied by utilizing OM,SEM,TEM and tensile tests.Experimental results showed that in the multiphase microstructure of the investigated steel when the finish rolling temperature was about 820℃and the final air cooling temperature was in the range of 630-700℃,the grain size of most of ferrite was finer(about 4μm)and which had higher dislocation density,the bainite packets had chaotic orientations and lath boundaries of bainite were not quite straight,the retained austenite distributed in the ferrite grain boundaries or triradius was fine and dispersive,and their grain size was about 0.4-1.9μm.With increasing the amount of ferrite,the volume fraction of retained austenite had a slight decrease.When the final air cooling temperature was 630℃,the steel had excellent mechanical properties,which was characterized by combination of continuous yielding,high strength(about 796 MPa)and high elongation(22.7%)as well as low yield/strength ratio(0.58);when the final air cooling temperature increased to 700℃,the matrix structure was bainite packets and the comprehensive properties were deteriorated.