Objective We aimed to determine the ef ects of low- and high-energy intensity-modulated radiation therapy (IMRT) photon beams on the target volume planning and on the critical organs in the case of prostate can-cer....Objective We aimed to determine the ef ects of low- and high-energy intensity-modulated radiation therapy (IMRT) photon beams on the target volume planning and on the critical organs in the case of prostate can-cer. Methods Thirty plans were generated by using either 6 MV or 15 MV beams separately, and a combination of both 6 and 15 MV beams. Al plans were generated by using suitable planning objectives and dose con-straints, which were identical across the plans, except the beam energy. The plans were analyzed in terms of their target coverage, conformity, and homogeneity, regardless of the beam energy. Results The mean percentage values of V70 Gy for the rectal wal for the plans with 6 MV, 15 MV, and mixed-energy beams were 16.9%, 17.8%, and 16.4%, respectively, while the mean percentage values of V40 Gy were 53.6%, 52.3%, and 50.4%. The mean dose values to the femoral heads for the 6 MV, 15 MV, and mixed-en-ergy plans were 30.1 Gy, 25.5 Gy, and 25.4 Gy, respectively. The mean integral dose for the 6 MV plans was 10% larger than those for the 15 MV and mixed-energy plans.Conclusion These preliminary results suggest that mixed-energy IMRT plans may be advantageous with respect to the dosimetric characteristics of low- and high-energy beams. Although the reduction of dose to the organs at risk may not be clinical y relevant, in this study, IMRT plans using mixed-energy beams exhibited better OAR sparing and overal higher plan quality for deep-seated tumors.展开更多
<strong>Purpose:</strong> The purpose of this study is to provide technical information on commissioning the TrueBeam STx 6 MV flattening-filter free (FFF) beam in the RayStation treatment planning system ...<strong>Purpose:</strong> The purpose of this study is to provide technical information on commissioning the TrueBeam STx 6 MV flattening-filter free (FFF) beam in the RayStation treatment planning system (TPS) for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. <strong>Methods:</strong> For beam modeling, percent depth dose curves, profiles and output factors for jaw-collimated fields and stereotactic cones as well as X-jaws transmission were measured. For multi-leaf collimator (MLC) modeling, MLC model parameters such as offset, gain, curvature, leaf tip width, tongue and groove and transmission were determined and output factors for MLC-collimated fields were measured. Absolute dose calibration was also performed. For beam model and MLC model validation, the American Association of Physicists in Medicine Task Group-119 plans, clinical SRS and SBRT plans and end-to-end testing were performed. <strong>Results:</strong> Beam characteristics of the 6 MV FFF beam agreed well with those in the literature. Validation results showed that our beam model and MLC model were acceptable for SRS and SBRT treatments. <strong>Conclusions:</strong> The technical information and dosimetric data provided in this study will be a useful reference for other clinics/institutions which will commission the same machine energy in the RayStation TPS.展开更多
文摘Objective We aimed to determine the ef ects of low- and high-energy intensity-modulated radiation therapy (IMRT) photon beams on the target volume planning and on the critical organs in the case of prostate can-cer. Methods Thirty plans were generated by using either 6 MV or 15 MV beams separately, and a combination of both 6 and 15 MV beams. Al plans were generated by using suitable planning objectives and dose con-straints, which were identical across the plans, except the beam energy. The plans were analyzed in terms of their target coverage, conformity, and homogeneity, regardless of the beam energy. Results The mean percentage values of V70 Gy for the rectal wal for the plans with 6 MV, 15 MV, and mixed-energy beams were 16.9%, 17.8%, and 16.4%, respectively, while the mean percentage values of V40 Gy were 53.6%, 52.3%, and 50.4%. The mean dose values to the femoral heads for the 6 MV, 15 MV, and mixed-en-ergy plans were 30.1 Gy, 25.5 Gy, and 25.4 Gy, respectively. The mean integral dose for the 6 MV plans was 10% larger than those for the 15 MV and mixed-energy plans.Conclusion These preliminary results suggest that mixed-energy IMRT plans may be advantageous with respect to the dosimetric characteristics of low- and high-energy beams. Although the reduction of dose to the organs at risk may not be clinical y relevant, in this study, IMRT plans using mixed-energy beams exhibited better OAR sparing and overal higher plan quality for deep-seated tumors.
文摘<strong>Purpose:</strong> The purpose of this study is to provide technical information on commissioning the TrueBeam STx 6 MV flattening-filter free (FFF) beam in the RayStation treatment planning system (TPS) for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. <strong>Methods:</strong> For beam modeling, percent depth dose curves, profiles and output factors for jaw-collimated fields and stereotactic cones as well as X-jaws transmission were measured. For multi-leaf collimator (MLC) modeling, MLC model parameters such as offset, gain, curvature, leaf tip width, tongue and groove and transmission were determined and output factors for MLC-collimated fields were measured. Absolute dose calibration was also performed. For beam model and MLC model validation, the American Association of Physicists in Medicine Task Group-119 plans, clinical SRS and SBRT plans and end-to-end testing were performed. <strong>Results:</strong> Beam characteristics of the 6 MV FFF beam agreed well with those in the literature. Validation results showed that our beam model and MLC model were acceptable for SRS and SBRT treatments. <strong>Conclusions:</strong> The technical information and dosimetric data provided in this study will be a useful reference for other clinics/institutions which will commission the same machine energy in the RayStation TPS.