Unbalanced force produced by the unbalanced mass will affect vibrations of rotor systems,which probably results in the components failures of rotating machinery.To study the effects of unbalanced mass on the vibration...Unbalanced force produced by the unbalanced mass will affect vibrations of rotor systems,which probably results in the components failures of rotating machinery.To study the effects of unbalanced mass on the vibration characteristics of rotor systems,a flexible rotor system model considering the unbalanced mass is proposed.The time-varying bearing force is considered.The developed model is verified by the experimental and theoretical frequency spectrums.The displacements and axis orbits of flexible and rigid rotor systems are compared.The results show that the unbalanced mass will affect the vibration characteristics of rotor system.This model can be more suitable and effective to calculate vibration characteristics of rotor system with the flexible deformation and unbalanced mass.This paper provides a new reference and research method for predicting the vibrations of flexible rotor system considering the unbalanced mass.展开更多
To decompose an unbalanced multi-stage logistic system to multipleindependent single-stage logistic systems, a new notion of parameterized interface distribution ispresented. For encoding the logistic pattern on each ...To decompose an unbalanced multi-stage logistic system to multipleindependent single-stage logistic systems, a new notion of parameterized interface distribution ispresented. For encoding the logistic pattern on each stage, the Pruefer number is used. With theimproved decoding procedure, any Pruefer number produced stochastically can be decoded to a feasiblelogistic pattern, which can match with the capacities of the nodes of the logistic system. Withthese two innovations, a new modeling method based on parameterized interface distribution and thePriifer number coding is put forward. The corresponding genetic algorithm, named as PIP-GA, can findbetter solutions and require less computational time than st-GA. Although requiring a little moreconsumption of memory, PIP-GA is still an efficient and robust method in the modeling andoptimization of unbalanced multi-stage logistic systems.展开更多
For the purpose of analyzing the torsional vibration caused by the gravitational unbalance torque arisen in a spindle system when it is machining heavy work piece,a 10-DOF lumped parameter model was made for the machi...For the purpose of analyzing the torsional vibration caused by the gravitational unbalance torque arisen in a spindle system when it is machining heavy work piece,a 10-DOF lumped parameter model was made for the machine tool spindle system with geared transmission.By using the elementary method and Runge-Kutta method in Matlab,the eigenvalue problem was solved and the pure torsional vibration responses were obtained and examined.The results show that the spindle system cannot operate in the desired constant rotating speed as far as the gravitational unbalance torque is engaged,so it may cause bad effect on machining accuracy.And the torsional vibration increases infinitely near the resonant frequencies,so the spindle system cannot operate normally during these spindle speed ranges.展开更多
Low pressure sputtering with a controlled ratio of ion flux to deposited atom flux at the condensing surface is one of the main directions of development of magnetron sputtering methods. Unbalanced magnetron sputterin...Low pressure sputtering with a controlled ratio of ion flux to deposited atom flux at the condensing surface is one of the main directions of development of magnetron sputtering methods. Unbalanced magnetron sputtering, by producing dense secondary plasma around the substrate, provides a high ion current density. The closed-field unbalanced magnetron sputtering system (CFUBMS) has been established as a versatile technique for high-rate deposition high-quality metal, alloy, and ceramic thin films. The'key factor in the CFUBMS system is the ability to transport high ion currents to the substrate, which can enhance the formation of full dense coatings at relatively low value homologous temperature. The investigation shows that the energy of ions incidenced at the substrate and the ratio of the flux of these ions to the flux of condensing atoms are the fundamental parameters in determining the structure and properties of films produced by ion-assisted deposition processes. Increasing ion bombardment during deposition combined with increasing mobility of the condensing atoms favors the formation of a dense microstructure and a smooth surface.展开更多
A novel control strategy for the load converter supplying the unbalanced AC load in a DC isolated distribution system is presented. The control algorithm results in balanced and sinusoidal load voltages under unbalanc...A novel control strategy for the load converter supplying the unbalanced AC load in a DC isolated distribution system is presented. The control algorithm results in balanced and sinusoidal load voltages under unbalanced AC loading. The unbalanced load is characterized in the d-q-0 rotating coordinate based on symmetrical sequence components. Also, the mathematical model of the load converter in both a-b-c and d-q-0 coordinates is derived by using the average large signal model. Then, two control strategies for the load converter are presented. The first one uses the conventional d-q-0 controller to ensure the voltage and current regulation. The second one is a newly proposed control strategy based on the decomposition of the voltage and current into in-stantaneous positive, negative, and zero sequences. These three sequences are controlled independently in their own reference frames as DC signals. The performance of the load converter using these two control strategies is compared. Simulation results show the validity and capability of the newly proposed control strategy.展开更多
Conventional squeeze film dampers have numerous challenges including lock up,bistable response and incoordinate precession.In order to resolve these nonlinear problems,a novel G-type integral squeeze film damper(GISFD...Conventional squeeze film dampers have numerous challenges including lock up,bistable response and incoordinate precession.In order to resolve these nonlinear problems,a novel G-type integral squeeze film damper(GISFD)is proposed in this research.The experimental test rig is provided to investigate the rotor system with an unbalanced single disk.Numerical simulation results show that the structural design of GISFD is reasonable,which can ensure its safe and stable operation.The influence of different support stiffnesses on the first-order speed of the rotor system is analyzed.Experimental results show that GISFD can effectively suppress the unbalanced response vibration of the rotor.In a certain range,it is found that the suppression effect of GISFD increases with the increase in the kinematic viscosity of the damping fluid.When the silicone oil with kinematic viscosity coefficients v=30.0 cm^(2)/s is employed,the vibration reduction of GISFD is approximately 71.51%.Furthermore,the experimental results show that with the increase of the unbalance,there is a linear relationship between the unbalance and the corresponding amplitude of the unbalanced response.It is concluded that GISFD has excellent linear damping characteristics and reduces the sensitivity of the rotor system to the unbalanced mass.展开更多
In this paper, a novel harmonic modeling technique by utilizing the concept of multi-terminal components is presented and applied to frequency scan analysis in multiphase distribution system. The proposed modeling tec...In this paper, a novel harmonic modeling technique by utilizing the concept of multi-terminal components is presented and applied to frequency scan analysis in multiphase distribution system. The proposed modeling technique is based on gathering the same phase busses and elements as a separate group (phase grouping technique, PGT) and uses multi-terminal components to model three-phase distribution system. Using multi- terminal component and PGT, distribution system elements, particularly, lines and transformers can effectively be modeled even in harmonic domain. The proposed modeling technique is applied to a test system for frequency scan analysis in order to show the frequency response of the test system in single and three-phase conditions. Consequently, the effects of mutual coupling and transformer connection types on three-phase frequency scan responses are analyzed for symmetrical and asymmetrical line configurations.展开更多
A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads...A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads.展开更多
This study addresses the critical challenge of reconfiguration in unbalanced power distribution networks(UPDNs),focusing on the complex 123-Bus test system.Three scenarios are investigated:(1)simultaneous power loss r...This study addresses the critical challenge of reconfiguration in unbalanced power distribution networks(UPDNs),focusing on the complex 123-Bus test system.Three scenarios are investigated:(1)simultaneous power loss reduction and voltage profile improvement,(2)minimization of voltage and current unbalance indices under various operational cases,and(3)multi-objective optimization using Pareto front analysis to concurrently optimize voltage unbalance index,active power loss,and current unbalance index.Unlike previous research that oftensimplified system components,this work maintains all equipment,including capacitor banks,transformers,and voltage regulators,to ensure realistic results.The study evaluates twelve metaheuristic algorithms to solve the reconfiguration problem(RecPrb)in UPDNs.A comprehensive statistical analysis is conducted to identify the most efficient algorithm for solving the RecPrb in the 123-Bus UPDN,employing multiple performance metrics and comparative techniques.The Artificial Hummingbird Algorithm emerges as the top-performing algorithm and is subsequently applied to address a multi-objective optimization challenge in the 123-Bus UPDN.This research contributes valuable insights for network operators and researchers in selecting suitable algorithms for specific reconfiguration scenarios,advancing the field of UPDN optimization and management.展开更多
The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leadi...The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leading to current zero-crossing distortion and compromised dynamic response.This paper investigates the causes of these distortions,identifying a phase shift between the input current and the grid voltage as a primary factor,and proposes an effective distortion phase identification strategy.Furthermore,the dynamic performance is enhanced through improved current reference calculations and a refined power feedforward strategy.This approach optimizes the system's response to load changes and maintains output voltage stability under unbalanced conditions.Simulation results validate the effectiveness of the proposed methods in reducing current distortion and improving overall performance.展开更多
This study examines various issues arising in three-phase unbalanced power distribution networks(PDNs)using a comprehensive optimization approach.With the integration of renewable energy sources,increasing energy dema...This study examines various issues arising in three-phase unbalanced power distribution networks(PDNs)using a comprehensive optimization approach.With the integration of renewable energy sources,increasing energy demands,and the adoption of smart grid technologies,power systems are undergoing a rapid transformation,making the need for efficient,reliable,and sustainable distribution networks increasingly critical.In this paper,the reconfiguration problem in a 37-bus unbalanced PDN test system is solved using five different popular metaheuristic algorithms.Among these advanced search algorithms,the Bonobo Optimizer(BO)has demonstrated superior performance in handling the complexities of unbalanced power distribution network optimization.The study is structured around four distinct scenarios:(Ⅰ)improving mean voltage profile and minimizing active power loss,(Ⅱ)minimizing Voltage Unbalance Index(VUI)and Current Unbalance Index(CUI),(Ⅲ)optimizing key reliability indices using both Line Oriented Reliability Index(LORI)and Customer Oriented Reliability Index(CORI)approaches,and(Ⅳ)employing multi-objective optimization using the Pareto front technique to simultaneously minimize active power loss,average CUI,and System Average Interruption Duration Index(SAIDI).The study aims to contribute to the development of more efficient,reliable,and sustainable energy systems by addressing voltage profiles,power losses,reduction of imbalance,and the enhancement of reliability together.展开更多
Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper ...Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.展开更多
This paper investigates a class of constrained distributed zeroth-order optimization(ZOO) problems over timevarying unbalanced graphs while ensuring privacy preservation among individual agents. Not taking into accoun...This paper investigates a class of constrained distributed zeroth-order optimization(ZOO) problems over timevarying unbalanced graphs while ensuring privacy preservation among individual agents. Not taking into account recent progress and addressing these concerns separately, there remains a lack of solutions offering theoretical guarantees for both privacy protection and constrained ZOO over time-varying unbalanced graphs.We hereby propose a novel algorithm, termed the differential privacy(DP) distributed push-sum based zeroth-order constrained optimization algorithm(DP-ZOCOA). Operating over time-varying unbalanced graphs, DP-ZOCOA obviates the need for supplemental suboptimization problem computations, thereby reducing overhead in comparison to distributed primary-dual methods. DP-ZOCOA is specifically tailored to tackle constrained ZOO problems over time-varying unbalanced graphs,offering a guarantee of convergence to the optimal solution while robustly preserving privacy. Moreover, we provide rigorous proofs of convergence and privacy for DP-ZOCOA, underscoring its efficacy in attaining optimal convergence without constraints. To enhance its applicability, we incorporate DP-ZOCOA into the federated learning framework and formulate a decentralized zeroth-order constrained federated learning algorithm(ZOCOA-FL) to address challenges stemming from the timevarying imbalance of communication topology. Finally, the performance and effectiveness of the proposed algorithms are thoroughly evaluated through simulations on distributed least squares(DLS) and decentralized federated learning(DFL) tasks.展开更多
This paper presents an extensive survey of the most commonly used tools for diagnosing unbalanced flow in the atmosphere, namely the Lagrangian Rossby number, Psi vector, divergence equation, nonlinear balance equatio...This paper presents an extensive survey of the most commonly used tools for diagnosing unbalanced flow in the atmosphere, namely the Lagrangian Rossby number, Psi vector, divergence equation, nonlinear balance equation, generalized omega-equation, and departure from fields obtained by potential vorticity (PV) inversion. The basic thoery, assumptions as well as implementation and limitations for each of the tools are all discussed. These tools are applied to high—resolution mesoscale model data to assess the role of unbalanced dynamics in the generation of a mesoscale gravity wave event over the East Coast of the United States. Comparison of these tools in this case study shows that these various methods agree to a large extent with each other though they differ in details. Key words Unbalanced flow - Geostrophic adjustment - Gravity waves - Nonlinear balance equation - Potential vorticity inversion - Omega equations - Rossby number This research was conducted under support from NSF grant ATM-9700626 of the United States. The numerical computations described herein were performed on the Cray T90 at the North Carolina Supercomputing Center and the Cray supercomputer at the NCAR Scientific Computing Division, which also provided the initialization fields for the MM5. Thanks are extended to Mark Stoelinga at University of Washington for the RIP post-processing package.展开更多
This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control ...This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.展开更多
Substantial unbalance may be caused by fan blade off during the operation period of gas turbine engines,and related dynamic problems are very critical to the safety design of rotor system in aero-engine.This article a...Substantial unbalance may be caused by fan blade off during the operation period of gas turbine engines,and related dynamic problems are very critical to the safety design of rotor system in aero-engine.This article aims to understand lateral-torsional coupled vibration of the rotor system with substantial unbalance.The governing equation of a modified unbalanced rotor system is established based on Lagrangian approach.Then,a mathematical analytical method is proposed in which a linear approximation is derived and the Floquet theory and Hill’s method are incorporated,from which the modal characteristics of the unbalanced rotor are obtained.The modal characteristics of the unbalanced rotor system are revealed comprehensively for the first time.Furthermore,the relation between the modes and responses of the unbalanced rotor is discussed in detail.The results show that the lateral vibration and torsional vibration of the unbalanced rotor are coupled through the inertial terms in the governing equations.Due to the coupling,veering and lock-in phenomena occur between the frequencies of the forward whirl mode and the torsional mode.Furthermore,lock-in can lead to a kind of principal instability.With regard to the response of the unbalanced rotor,both natural vibration components and enforced vibration components appear in the lateral response,while only natural vibration components appear during torsional vibration.Moreover,natural vibration components play a crucial role in the response within the principal instability region and cause divergence of the vibration amplitudes in the lateral and torsional directions.展开更多
In this paper,the piston type valve core and the unbalanced moment on its bottom are studied.To decrease the influence of non-common geometrical factors,a simplified model of the piston type globe valve is proposed in...In this paper,the piston type valve core and the unbalanced moment on its bottom are studied.To decrease the influence of non-common geometrical factors,a simplified model of the piston type globe valve is proposed in this study.Based on the computational fluid dynamics(CFD)method,the effects of different geometrical parameters on the unbalanced moment existing on the bottom of the valve core,which include the bending radius of the inlet flow channel,the diameter of the special-shaped pipe,and the height of the valve core,are studied.Finally,the effects of geometrical parameters on the unbalanced moment on the bottom of the valve core are clarified by correction and variation classification and provide a basis for further optimizing the structure of the piston type valve.The results show that the unbalanced moment decreases with the increase of the bending radius of the inlet flow channel,but increases with the increase of the diameter of the special-shaped pipe and the height of the valve core.Moreover,the relation between the unbalanced moment and flow rate is proposed.展开更多
The energy density of non-aqueous carbon-based electrochemical capacitors(cEC)is mainly determined by the specific capacitance and operational voltage range.In this study,we propose to construct an unbalanced structur...The energy density of non-aqueous carbon-based electrochemical capacitors(cEC)is mainly determined by the specific capacitance and operational voltage range.In this study,we propose to construct an unbalanced structure to make full use of stable voltage range for improving energy density.The stable voltage range is firstly carefully explored using cyclic voltammetry.Then an unbalanced carbon-based electrochemical capacitor(ucEC)is constructed with an optimized positive electrode to negative electrode weight ratio and voltage range.Its electrochemical performance is comprehensively investigated,including energy density,power density as well as cycle life.The ucEC is capable to deliver an improved energy density up to 64.9 Wh/kg(1.4 times as high as a general cEC)without sacrificing the power density and cycle life.The electrode properties after cycling are also analyzed,illustrating the change of electrode potential caused by unbalanced structure.The proposed structure demonstrates a great potential for improving the energy density at little cost of electrode design and cell configuration.展开更多
A structure iterated by the unbalanced Feistel networks is introduced. It is showed that this structure is provable resistant against linear attack. The main result of this paper is that the upper bound of r-round (r...A structure iterated by the unbalanced Feistel networks is introduced. It is showed that this structure is provable resistant against linear attack. The main result of this paper is that the upper bound of r-round (r≥2m) linear hull probabilities are bounded by q^2 when around function F is bijective and the maximal linear hull probabilities of round function F is q. Application of this structure to block cipher designs brings out the provable security against linear attack with the upper bounds of probabilities.展开更多
Rapid and precise location of the faults of on-board equipment of train control system is a significant factor to ensure reliable train operation.Text data of the fault tracking table of on-board equipment are taken a...Rapid and precise location of the faults of on-board equipment of train control system is a significant factor to ensure reliable train operation.Text data of the fault tracking table of on-board equipment are taken as samples,and an on-board equipment fault diagnosis model is designed based on the combination of convolutional neural network(CNN)and particle swarm optimization-support vector machines(PSO-SVM).Due to the characteristics of high dimensionality and sparseness of fault text data,CNN is used to achieve feature extraction.In order to decrease the influence of the imbalance of the fault sample data category on the classification accuracy,the PSO-SVM algorithm is introduced.The fully connected classification part of CNN is replaced by PSO-SVM,the extracted features are classified precisely,and the intelligent diagnosis of on-board equipment fault is implemented.According to the test analysis of the fault text data of on-board equipment recorded by a railway bureau and comparison with other models,the experimental results indicate that this model can obviously upgrade the evaluation indexes and can be used as an effective model for fault diagnosis for on-board equipment.展开更多
基金Support by Shanxi Provincial Key Research and Development Plan of China(Grant No.2024GH-ZDXM-29)National Natural Science Foundation of China(Grant No.52175120)Shaanxi Provincial Innovation Capability Support Program of China(Grant No.2024RS-CXTD-15)。
文摘Unbalanced force produced by the unbalanced mass will affect vibrations of rotor systems,which probably results in the components failures of rotating machinery.To study the effects of unbalanced mass on the vibration characteristics of rotor systems,a flexible rotor system model considering the unbalanced mass is proposed.The time-varying bearing force is considered.The developed model is verified by the experimental and theoretical frequency spectrums.The displacements and axis orbits of flexible and rigid rotor systems are compared.The results show that the unbalanced mass will affect the vibration characteristics of rotor system.This model can be more suitable and effective to calculate vibration characteristics of rotor system with the flexible deformation and unbalanced mass.This paper provides a new reference and research method for predicting the vibrations of flexible rotor system considering the unbalanced mass.
文摘To decompose an unbalanced multi-stage logistic system to multipleindependent single-stage logistic systems, a new notion of parameterized interface distribution ispresented. For encoding the logistic pattern on each stage, the Pruefer number is used. With theimproved decoding procedure, any Pruefer number produced stochastically can be decoded to a feasiblelogistic pattern, which can match with the capacities of the nodes of the logistic system. Withthese two innovations, a new modeling method based on parameterized interface distribution and thePriifer number coding is put forward. The corresponding genetic algorithm, named as PIP-GA, can findbetter solutions and require less computational time than st-GA. Although requiring a little moreconsumption of memory, PIP-GA is still an efficient and robust method in the modeling andoptimization of unbalanced multi-stage logistic systems.
基金Project(10033135-2009-11) supported by the Korean Ministry of Knowledge Economy (MKE) through HNK. Co,Ltd.
文摘For the purpose of analyzing the torsional vibration caused by the gravitational unbalance torque arisen in a spindle system when it is machining heavy work piece,a 10-DOF lumped parameter model was made for the machine tool spindle system with geared transmission.By using the elementary method and Runge-Kutta method in Matlab,the eigenvalue problem was solved and the pure torsional vibration responses were obtained and examined.The results show that the spindle system cannot operate in the desired constant rotating speed as far as the gravitational unbalance torque is engaged,so it may cause bad effect on machining accuracy.And the torsional vibration increases infinitely near the resonant frequencies,so the spindle system cannot operate normally during these spindle speed ranges.
文摘Low pressure sputtering with a controlled ratio of ion flux to deposited atom flux at the condensing surface is one of the main directions of development of magnetron sputtering methods. Unbalanced magnetron sputtering, by producing dense secondary plasma around the substrate, provides a high ion current density. The closed-field unbalanced magnetron sputtering system (CFUBMS) has been established as a versatile technique for high-rate deposition high-quality metal, alloy, and ceramic thin films. The'key factor in the CFUBMS system is the ability to transport high ion currents to the substrate, which can enhance the formation of full dense coatings at relatively low value homologous temperature. The investigation shows that the energy of ions incidenced at the substrate and the ratio of the flux of these ions to the flux of condensing atoms are the fundamental parameters in determining the structure and properties of films produced by ion-assisted deposition processes. Increasing ion bombardment during deposition combined with increasing mobility of the condensing atoms favors the formation of a dense microstructure and a smooth surface.
文摘A novel control strategy for the load converter supplying the unbalanced AC load in a DC isolated distribution system is presented. The control algorithm results in balanced and sinusoidal load voltages under unbalanced AC loading. The unbalanced load is characterized in the d-q-0 rotating coordinate based on symmetrical sequence components. Also, the mathematical model of the load converter in both a-b-c and d-q-0 coordinates is derived by using the average large signal model. Then, two control strategies for the load converter are presented. The first one uses the conventional d-q-0 controller to ensure the voltage and current regulation. The second one is a newly proposed control strategy based on the decomposition of the voltage and current into in-stantaneous positive, negative, and zero sequences. These three sequences are controlled independently in their own reference frames as DC signals. The performance of the load converter using these two control strategies is compared. Simulation results show the validity and capability of the newly proposed control strategy.
基金Supported by the National Science and Technology Major Project(No.2017-Ⅳ-0010-0047)the Fundamental Research Funds for the Central Universities(No.JD2003)。
文摘Conventional squeeze film dampers have numerous challenges including lock up,bistable response and incoordinate precession.In order to resolve these nonlinear problems,a novel G-type integral squeeze film damper(GISFD)is proposed in this research.The experimental test rig is provided to investigate the rotor system with an unbalanced single disk.Numerical simulation results show that the structural design of GISFD is reasonable,which can ensure its safe and stable operation.The influence of different support stiffnesses on the first-order speed of the rotor system is analyzed.Experimental results show that GISFD can effectively suppress the unbalanced response vibration of the rotor.In a certain range,it is found that the suppression effect of GISFD increases with the increase in the kinematic viscosity of the damping fluid.When the silicone oil with kinematic viscosity coefficients v=30.0 cm^(2)/s is employed,the vibration reduction of GISFD is approximately 71.51%.Furthermore,the experimental results show that with the increase of the unbalance,there is a linear relationship between the unbalance and the corresponding amplitude of the unbalanced response.It is concluded that GISFD has excellent linear damping characteristics and reduces the sensitivity of the rotor system to the unbalanced mass.
文摘In this paper, a novel harmonic modeling technique by utilizing the concept of multi-terminal components is presented and applied to frequency scan analysis in multiphase distribution system. The proposed modeling technique is based on gathering the same phase busses and elements as a separate group (phase grouping technique, PGT) and uses multi-terminal components to model three-phase distribution system. Using multi- terminal component and PGT, distribution system elements, particularly, lines and transformers can effectively be modeled even in harmonic domain. The proposed modeling technique is applied to a test system for frequency scan analysis in order to show the frequency response of the test system in single and three-phase conditions. Consequently, the effects of mutual coupling and transformer connection types on three-phase frequency scan responses are analyzed for symmetrical and asymmetrical line configurations.
基金This project is financed by the New Century Outstanding Talents Supporting Program of Ministry of Education and Superior Young Teachers Supporting Program of Ministry of Education.
文摘A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads.
基金supported by the Scientific and Technological Research Council of Turkey(TUBITAK)under Grant No.124E002(1001-Project).
文摘This study addresses the critical challenge of reconfiguration in unbalanced power distribution networks(UPDNs),focusing on the complex 123-Bus test system.Three scenarios are investigated:(1)simultaneous power loss reduction and voltage profile improvement,(2)minimization of voltage and current unbalance indices under various operational cases,and(3)multi-objective optimization using Pareto front analysis to concurrently optimize voltage unbalance index,active power loss,and current unbalance index.Unlike previous research that oftensimplified system components,this work maintains all equipment,including capacitor banks,transformers,and voltage regulators,to ensure realistic results.The study evaluates twelve metaheuristic algorithms to solve the reconfiguration problem(RecPrb)in UPDNs.A comprehensive statistical analysis is conducted to identify the most efficient algorithm for solving the RecPrb in the 123-Bus UPDN,employing multiple performance metrics and comparative techniques.The Artificial Hummingbird Algorithm emerges as the top-performing algorithm and is subsequently applied to address a multi-objective optimization challenge in the 123-Bus UPDN.This research contributes valuable insights for network operators and researchers in selecting suitable algorithms for specific reconfiguration scenarios,advancing the field of UPDN optimization and management.
文摘The Vienna rectifier is a widely adopted solution for high-power rectification due to its efficiency and straightforward design.However,its performance can degrade under unbalanced three phase voltage conditions,leading to current zero-crossing distortion and compromised dynamic response.This paper investigates the causes of these distortions,identifying a phase shift between the input current and the grid voltage as a primary factor,and proposes an effective distortion phase identification strategy.Furthermore,the dynamic performance is enhanced through improved current reference calculations and a refined power feedforward strategy.This approach optimizes the system's response to load changes and maintains output voltage stability under unbalanced conditions.Simulation results validate the effectiveness of the proposed methods in reducing current distortion and improving overall performance.
基金supported by the Scientific and Technological Research Council of Turkey(TUBITAK)under Grant No.124E002(1001-Project).
文摘This study examines various issues arising in three-phase unbalanced power distribution networks(PDNs)using a comprehensive optimization approach.With the integration of renewable energy sources,increasing energy demands,and the adoption of smart grid technologies,power systems are undergoing a rapid transformation,making the need for efficient,reliable,and sustainable distribution networks increasingly critical.In this paper,the reconfiguration problem in a 37-bus unbalanced PDN test system is solved using five different popular metaheuristic algorithms.Among these advanced search algorithms,the Bonobo Optimizer(BO)has demonstrated superior performance in handling the complexities of unbalanced power distribution network optimization.The study is structured around four distinct scenarios:(Ⅰ)improving mean voltage profile and minimizing active power loss,(Ⅱ)minimizing Voltage Unbalance Index(VUI)and Current Unbalance Index(CUI),(Ⅲ)optimizing key reliability indices using both Line Oriented Reliability Index(LORI)and Customer Oriented Reliability Index(CORI)approaches,and(Ⅳ)employing multi-objective optimization using the Pareto front technique to simultaneously minimize active power loss,average CUI,and System Average Interruption Duration Index(SAIDI).The study aims to contribute to the development of more efficient,reliable,and sustainable energy systems by addressing voltage profiles,power losses,reduction of imbalance,and the enhancement of reliability together.
基金supported by the key technology project of China Southern Power Grid Corporation(GZKJXM20220041)partly by theNational Key Research and Development Plan(2022YFE0205300).
文摘Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.
基金supported in part by the National Key Research and Development Program of China(2022ZD0120001)the National Natural Science Foundation of China(62233004,62273090,62073076)the Jiangsu Provincial Scientific Research Center of Applied Mathematics(BK20233002)
文摘This paper investigates a class of constrained distributed zeroth-order optimization(ZOO) problems over timevarying unbalanced graphs while ensuring privacy preservation among individual agents. Not taking into account recent progress and addressing these concerns separately, there remains a lack of solutions offering theoretical guarantees for both privacy protection and constrained ZOO over time-varying unbalanced graphs.We hereby propose a novel algorithm, termed the differential privacy(DP) distributed push-sum based zeroth-order constrained optimization algorithm(DP-ZOCOA). Operating over time-varying unbalanced graphs, DP-ZOCOA obviates the need for supplemental suboptimization problem computations, thereby reducing overhead in comparison to distributed primary-dual methods. DP-ZOCOA is specifically tailored to tackle constrained ZOO problems over time-varying unbalanced graphs,offering a guarantee of convergence to the optimal solution while robustly preserving privacy. Moreover, we provide rigorous proofs of convergence and privacy for DP-ZOCOA, underscoring its efficacy in attaining optimal convergence without constraints. To enhance its applicability, we incorporate DP-ZOCOA into the federated learning framework and formulate a decentralized zeroth-order constrained federated learning algorithm(ZOCOA-FL) to address challenges stemming from the timevarying imbalance of communication topology. Finally, the performance and effectiveness of the proposed algorithms are thoroughly evaluated through simulations on distributed least squares(DLS) and decentralized federated learning(DFL) tasks.
文摘This paper presents an extensive survey of the most commonly used tools for diagnosing unbalanced flow in the atmosphere, namely the Lagrangian Rossby number, Psi vector, divergence equation, nonlinear balance equation, generalized omega-equation, and departure from fields obtained by potential vorticity (PV) inversion. The basic thoery, assumptions as well as implementation and limitations for each of the tools are all discussed. These tools are applied to high—resolution mesoscale model data to assess the role of unbalanced dynamics in the generation of a mesoscale gravity wave event over the East Coast of the United States. Comparison of these tools in this case study shows that these various methods agree to a large extent with each other though they differ in details. Key words Unbalanced flow - Geostrophic adjustment - Gravity waves - Nonlinear balance equation - Potential vorticity inversion - Omega equations - Rossby number This research was conducted under support from NSF grant ATM-9700626 of the United States. The numerical computations described herein were performed on the Cray T90 at the North Carolina Supercomputing Center and the Cray supercomputer at the NCAR Scientific Computing Division, which also provided the initialization fields for the MM5. Thanks are extended to Mark Stoelinga at University of Washington for the RIP post-processing package.
基金Project (No. 50577056) supported by the National Natural ScienceFoundation of China
文摘This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results.
基金the support from the National Natural Science Foundation of China(Nos.11772022,51575022 and 51475021)the support by the Academic Excellence Foundation of BUAA for Ph.D.Students。
文摘Substantial unbalance may be caused by fan blade off during the operation period of gas turbine engines,and related dynamic problems are very critical to the safety design of rotor system in aero-engine.This article aims to understand lateral-torsional coupled vibration of the rotor system with substantial unbalance.The governing equation of a modified unbalanced rotor system is established based on Lagrangian approach.Then,a mathematical analytical method is proposed in which a linear approximation is derived and the Floquet theory and Hill’s method are incorporated,from which the modal characteristics of the unbalanced rotor are obtained.The modal characteristics of the unbalanced rotor system are revealed comprehensively for the first time.Furthermore,the relation between the modes and responses of the unbalanced rotor is discussed in detail.The results show that the lateral vibration and torsional vibration of the unbalanced rotor are coupled through the inertial terms in the governing equations.Due to the coupling,veering and lock-in phenomena occur between the frequencies of the forward whirl mode and the torsional mode.Furthermore,lock-in can lead to a kind of principal instability.With regard to the response of the unbalanced rotor,both natural vibration components and enforced vibration components appear in the lateral response,while only natural vibration components appear during torsional vibration.Moreover,natural vibration components play a crucial role in the response within the principal instability region and cause divergence of the vibration amplitudes in the lateral and torsional directions.
基金Project supported by the National Natural Science Foundation of China(No.51805470)the Zhejiang Provincial Key Research&Development Project(No.2019C01025)and the Youth Funds of the State Key Laboratory of Fluid Power and Mechatronic Systems(Zhejiang University)(No.SKLoFP-QN-1801),China。
文摘In this paper,the piston type valve core and the unbalanced moment on its bottom are studied.To decrease the influence of non-common geometrical factors,a simplified model of the piston type globe valve is proposed in this study.Based on the computational fluid dynamics(CFD)method,the effects of different geometrical parameters on the unbalanced moment existing on the bottom of the valve core,which include the bending radius of the inlet flow channel,the diameter of the special-shaped pipe,and the height of the valve core,are studied.Finally,the effects of geometrical parameters on the unbalanced moment on the bottom of the valve core are clarified by correction and variation classification and provide a basis for further optimizing the structure of the piston type valve.The results show that the unbalanced moment decreases with the increase of the bending radius of the inlet flow channel,but increases with the increase of the diameter of the special-shaped pipe and the height of the valve core.Moreover,the relation between the unbalanced moment and flow rate is proposed.
基金financial support from the National Natural Science Foundation of China(No.51777140)the Fundamental Research Funds for the Central Universities at Tongji University(No.22120180519/22120180308)partly supported by US Army Research Laboratory(No.W911NF-12-R-0011-03)。
文摘The energy density of non-aqueous carbon-based electrochemical capacitors(cEC)is mainly determined by the specific capacitance and operational voltage range.In this study,we propose to construct an unbalanced structure to make full use of stable voltage range for improving energy density.The stable voltage range is firstly carefully explored using cyclic voltammetry.Then an unbalanced carbon-based electrochemical capacitor(ucEC)is constructed with an optimized positive electrode to negative electrode weight ratio and voltage range.Its electrochemical performance is comprehensively investigated,including energy density,power density as well as cycle life.The ucEC is capable to deliver an improved energy density up to 64.9 Wh/kg(1.4 times as high as a general cEC)without sacrificing the power density and cycle life.The electrode properties after cycling are also analyzed,illustrating the change of electrode potential caused by unbalanced structure.The proposed structure demonstrates a great potential for improving the energy density at little cost of electrode design and cell configuration.
基金Supported by the fund of National Laboratory for Modern Communications (5143603ZDS0601),the outstanding youth science foundation of Henan (0312001800).
文摘A structure iterated by the unbalanced Feistel networks is introduced. It is showed that this structure is provable resistant against linear attack. The main result of this paper is that the upper bound of r-round (r≥2m) linear hull probabilities are bounded by q^2 when around function F is bijective and the maximal linear hull probabilities of round function F is q. Application of this structure to block cipher designs brings out the provable security against linear attack with the upper bounds of probabilities.
基金Gansu Province Higher Education Innovation Fund Project(No.2020B-104)“Innovation Star”Project for Outstanding Postgraduates of Gansu Province(No.2021CXZX-606)。
文摘Rapid and precise location of the faults of on-board equipment of train control system is a significant factor to ensure reliable train operation.Text data of the fault tracking table of on-board equipment are taken as samples,and an on-board equipment fault diagnosis model is designed based on the combination of convolutional neural network(CNN)and particle swarm optimization-support vector machines(PSO-SVM).Due to the characteristics of high dimensionality and sparseness of fault text data,CNN is used to achieve feature extraction.In order to decrease the influence of the imbalance of the fault sample data category on the classification accuracy,the PSO-SVM algorithm is introduced.The fully connected classification part of CNN is replaced by PSO-SVM,the extracted features are classified precisely,and the intelligent diagnosis of on-board equipment fault is implemented.According to the test analysis of the fault text data of on-board equipment recorded by a railway bureau and comparison with other models,the experimental results indicate that this model can obviously upgrade the evaluation indexes and can be used as an effective model for fault diagnosis for on-board equipment.