期刊文献+
共找到48篇文章
< 1 2 3 >
每页显示 20 50 100
Remarks on the Total Angular Momentum in General Relativity 被引量:2
1
作者 ZHANGXiao 《Communications in Theoretical Physics》 SCIE CAS CSCD 2003年第5期521-524,共4页
We verify that the total angular momentum 3-vector defined by the author [X. Zhang, Commun. Math.Phys. 206 (1999) 137] is equal to (0, 0, ma) forany time slice in both the Kerr and the Kerr-Newman spacetimes.
关键词 total angular momentum general relativity
在线阅读 下载PDF
Clinical Application and Exploration on Steps Progressively Corrections and Gradual Shortening Combined with Total Spinal Osteotomy for Angular Kyphosis—Basic Research and Clinical Application
2
作者 Ming Lu Xiaoping Wang +1 位作者 Dongyun Ren Huasong Ma 《Surgical Science》 2016年第1期39-47,共9页
Introduction: This study is designed to explore the biomechanical principles of posterior bilateral pedicle screw on steps progressively and tight closure on every step for severe angular kyphosis and the indication c... Introduction: This study is designed to explore the biomechanical principles of posterior bilateral pedicle screw on steps progressively and tight closure on every step for severe angular kyphosis and the indication conditions and clinical pathways of above new technique. Materials and Methods: A total of 90 patients have severe angular kyphosis, 37 males and 53 females, with an average age of 47 years. All patients were treated with posterior bilateral pedicle screw and step tight closure for gradual shortening and orthopedic technology. Results: Average intraoperative blood loss was 2089 ml. Average operation time was 326 minutes. Kyphotic angle changed from 90.1° averagely preoperatively to 41.6° averagely postoperatively with an improvement rate of 65%. The distance from C<sub>7</sub> plumb line to posterior upper edge of the S<sub>1</sub> vertebral body was averagely 5.2 mm postoperatively, with a correction rate of 73%. Neurological complications occurred in 2 cases, accounting for 6%. Non-neurological complications occurred in 2 cases, accounting for 6%. Anatomical parameters were significantly improved postoperatively (P < 0.05). All patients were averagely followed up for 28 months. Segments undergoing osteotomy achieved bone fusion, without loss of orthopedic angle. Conclusions: The orthopedic technology of bilateral pedicle screw and step tight closure designed by human physiology and biomechanical principles can protect spinal cord cells from injury to the utmost. To choose an appropriate osteotomy plane during pre-surgical planning can make the repair results closer to the normal function of the spine. Intraoperative nerve root protection, full release and bone graft fusion are effective safeguards to ensure kyphosis correction and to avoid spine lateral offset. 展开更多
关键词 angular Kyphosis total Spinal Osteotomy Biomechanical Analysis Clinical Outcome
暂未订购
Angular distribution of sputtered atoms induced by low-energy heavy ion bombardment 被引量:2
3
作者 ZHANGLai ZHANGZhu-Lin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2004年第6期340-343,共4页
The sputtering yield angular distributions have been calculated based on the ion energy dependence of to- tal sputtering yields for Ni and Mo targets bombarded by low-energy Hg+ ion. The calculated curves show excelle... The sputtering yield angular distributions have been calculated based on the ion energy dependence of to- tal sputtering yields for Ni and Mo targets bombarded by low-energy Hg+ ion. The calculated curves show excellent agreement with the corresponding Wehner’s experimental results of sputtering yield angular distribution. The fact clearly demonstrated the intrinsic relation between the ion energy dependence of total sputtering yields and the sput- tering yield angular distribution. This intrinsic relation had been ignored in Yamamura’s papers (1981,1982) due to some obvious mistakes. 展开更多
关键词 溅射当量 辐角分布 各向异性效应 原子物理学
在线阅读 下载PDF
全站仪教学中对中整平操作相互影响机理分析与验证
4
作者 金银龙 严鹏 +2 位作者 楼晓伦 吴云芳 刘任莉 《测绘地理信息》 2025年第4期70-74,共5页
角度测量是测量学教学基本内容之一,其中全站仪安置操作是难点。目前各类教材针对测角设备安置操作步骤都做了详细的讲解,但少见针对操作中对中和整平相互影响机理的剖析。教学中角度观测实验对全站仪安置的考核停留在学生操作设备实现... 角度测量是测量学教学基本内容之一,其中全站仪安置操作是难点。目前各类教材针对测角设备安置操作步骤都做了详细的讲解,但少见针对操作中对中和整平相互影响机理的剖析。教学中角度观测实验对全站仪安置的考核停留在学生操作设备实现可使用状态的层次,学生仅掌握操作方法缺乏对操作机理的理解,难以达到深度学习效果,长期稳固地掌握操作方法。本文通过分析全站仪安置过程中对中整平操作引起的仪器对应空间姿态变化,揭示了全站仪整平对中操作影响的机理,并进行实验验证。本文有助于提高学生对全站仪安置操作的理解,同时有助于全站仪操作虚拟仿真教学软件的开发。 展开更多
关键词 测量学 角度观测 全站仪 对中整平 影响机制
原文传递
实孔径雷达无超参数全变差正则化角超分辨方法
5
作者 张永超 孙震宇 +4 位作者 蔡晓春 毛德庆 张寅 黄钰林 杨建宇 《雷达学报(中英文)》 北大核心 2025年第6期1469-1479,共11页
受平台物理空间限制,实孔径雷达天线波束宽、角分辨率低下。基于稀疏重建的角超分辨方法,在正则化框架下引入目标稀疏先验约束并通过迭代优化求解对目标散射分布进行反演,是提升实孔径雷达角分辨率的重要途径。然而,现有稀疏重建方法仅... 受平台物理空间限制,实孔径雷达天线波束宽、角分辨率低下。基于稀疏重建的角超分辨方法,在正则化框架下引入目标稀疏先验约束并通过迭代优化求解对目标散射分布进行反演,是提升实孔径雷达角分辨率的重要途径。然而,现有稀疏重建方法仅考虑了强点目标的稀疏分布特性,未考虑扩展目标的轮廓信息,存在目标边缘恢复失真的问题;同时,现有稀疏重建方法对代价函数中引入的超参数敏感,实际应用中依赖人工精细调整,难以根据不同场景进行自适应选取。针对上述两个问题,该文提出一种无超参数全变差(TV)正则化角超分辨方法,首先建立一种均方根LASSO代价函数,用于表征扫描回波序列与目标散射分布的拟合残差,以及目标边缘梯度的稀疏约束,从而将目标轮廓重建问题重转化为TV正则化约束下的非平滑凸优化问题;然后基于协方差拟合准则,导出了无超参数TV正则化约束的解析表达;最后提出一种广义迭代重加权最小二乘(GIRLS)求解策略,实现了均方根LASSO非平滑凸优化问题的迭代优化求解。仿真和实测结果表明,该文提出的方法能够在改善分辨率的同时保持目标的轮廓信息,且无需人工调整超参数。 展开更多
关键词 实孔径雷达 角超分辨 无超参数 全变差正则化 协方差拟合准则
在线阅读 下载PDF
Generating Entangled Pairs of Vortex Photons via Induced Emission
6
作者 D.V.Grosman G.K.Sizykh +2 位作者 E.O.Lazarev G.V.Voloshin D.V.Karlovets 《Chinese Physics Letters》 2025年第12期115-125,共11页
Pairs of entangled vortex photons can promise new prospects of application in quantum computing and cryptography.We investigate the possibility of generating such states via two-level atom emission induced by a single... Pairs of entangled vortex photons can promise new prospects of application in quantum computing and cryptography.We investigate the possibility of generating such states via two-level atom emission induced by a single photon wave packet with a definite total angular momentum(TAM).The entangled pair produced in this process possesses well-defined mean TAM with the TAM variation being much smaller than h.On top of that,the variation exponentially decreases with the increase in TAM of the incident photon.Our model allows one to track the time evolution of the state of the entangled pair.An experimentally feasible scenario is assumed,in which the incident photon interacts with a spatially confined atomic target.We conclude that induced emission can be used as a source of entangled vortex photons with applications in atomic physics experiments,quantum optics,and quantum information sciences. 展开更多
关键词 entangled vortex photons total angular momentum tam incident photonour entangled pair quantum computing photon wave vortex photons entangled photons
原文传递
对角动量算符的讨论——对自旋的讨论之三 被引量:7
7
作者 许方官 高春媛 《大学物理》 北大核心 2001年第1期29-31,共3页
从算符 ^J的构成上证明 ,所谓的总角动量J实质上是相对论性的轨道角动量 ,自旋是相对论性轨道角动量的一个组成部分 .
关键词 质量算符 自旋 轨道角动量 总角动量 量子理论
在线阅读 下载PDF
单纯经后路全脊椎切除治疗胸段治愈型结核并重度角状后凸畸形 被引量:7
8
作者 张宏其 王瑶 +5 位作者 刘少华 唐明星 王昱祥 刘金洋 吴建煌 葛磊 《中国骨与关节损伤杂志》 2010年第11期972-974,共3页
目的探讨病变胸段治愈型结核合并重度角状后凸畸形的外科治疗方法。方法自2003年5月~2008年10月收治胸段治愈型结核并重度角状后凸畸形7例,均行后路一期全脊椎切除加椎间植骨术,术前术后分别测量脊柱Cobb角、侧位片上C7~S1的水平距离... 目的探讨病变胸段治愈型结核合并重度角状后凸畸形的外科治疗方法。方法自2003年5月~2008年10月收治胸段治愈型结核并重度角状后凸畸形7例,均行后路一期全脊椎切除加椎间植骨术,术前术后分别测量脊柱Cobb角、侧位片上C7~S1的水平距离及神经功能AISA分级;定期行放射学检查和临床评估。结果切口均一期愈合。Cobb角术前平均97.4°,术后平均为38.0°,平均矫正59.4°,矫正率61.0%。C7~S1距离术前平均50.2 mm,术后平均18.3mm,矫正率63.4%。术前7例伴神经功能障碍者均有改善。所有病例均获得良好骨性愈合,无明显矫正丢失。结论采用后路全脊椎切除加椎间植骨术外科治疗效果显著,应注意防止手术并发症的发生,规范治疗是减少并发症发生的关键。 展开更多
关键词 重度后凸畸形 结核 全脊椎切除 并发症
原文传递
棱镜瞄准特征选择引起的全站仪测角误差分析 被引量:4
9
作者 梁静 王铜 +9 位作者 董岚 罗涛 何振强 柯志勇 马娜 门玲鸰 李波 王小龙 沈建新 张晓辉 《测绘通报》 CSCD 北大核心 2019年第S1期217-221,共5页
在精密控制网测量和精密三角高程测量时,需要保证角度的测量精度。本文对全站仪采用人工照准方式瞄准棱镜的过程中,棱镜瞄准特征的不同选择所导致的测角误差进行了理论分析。通过分析表明,当棱镜与全站仪视线不垂直时,全站仪瞄准棱镜的... 在精密控制网测量和精密三角高程测量时,需要保证角度的测量精度。本文对全站仪采用人工照准方式瞄准棱镜的过程中,棱镜瞄准特征的不同选择所导致的测角误差进行了理论分析。通过分析表明,当棱镜与全站仪视线不垂直时,全站仪瞄准棱镜的外框中心所引起的测角误差较大,全站仪瞄准棱镜反射角点所引起的测角误差则可以忽略不计。并给出了全站仪人工瞄准棱镜的最佳方式,在精密测量时应保证棱镜和全站仪的视线垂直,并尽量选择带觇板的棱镜进行测角,这样能减小棱镜与全站仪视线不垂直所引起的测角误差。 展开更多
关键词 全站仪 人工瞄准 棱镜 觇板 测角误差
原文传递
360°激光扫描仪的测角误差检校研究 被引量:4
10
作者 韩友美 王留召 卢秀山 《工程勘察》 CSCD 北大核心 2011年第2期59-63,共5页
激光扫描仪作为三维信息获取的一门高新技术逐步得到测绘专家和学者的关注,随着精细测量要求的不断提高,该类测绘仪器的检校问题成为当前又一热点研究主题。本文从我国新型RA-360 360°激光扫描仪的工作原理和构造出发,详细分析了... 激光扫描仪作为三维信息获取的一门高新技术逐步得到测绘专家和学者的关注,随着精细测量要求的不断提高,该类测绘仪器的检校问题成为当前又一热点研究主题。本文从我国新型RA-360 360°激光扫描仪的工作原理和构造出发,详细分析了其角度测量误差的来源,并在此基础上建立了此类激光扫描仪角度测量误差检校模型,并设计了相应的检校实验。实验结果表明,该模型具有较好的可靠性和实用价值,可大大提高该激光扫描仪的角度测量精度,为激光扫描仪测量精度的提高奠定了良好的基础,也可为同类产品的检校提供参考。 展开更多
关键词 激光扫描仪 角度误差 检校 光学编码器 全站仪
原文传递
MIMO雷达比幅单脉冲测角精度分析 被引量:7
11
作者 李军 王珍 +1 位作者 张娟娟 刘红明 《系统工程与电子技术》 EI CSCD 北大核心 2015年第1期55-60,共6页
和差比幅单脉冲测角方法由于实现简单且测角精度高,在雷达系统中得到广泛应用。研究多输入多输出(multiple-input multiple-output,MIMO)雷达的比幅单脉冲测角技术及其精度问题,采用全微分方法详细推导了MIMO雷达和传统相控阵雷达的单... 和差比幅单脉冲测角方法由于实现简单且测角精度高,在雷达系统中得到广泛应用。研究多输入多输出(multiple-input multiple-output,MIMO)雷达的比幅单脉冲测角技术及其精度问题,采用全微分方法详细推导了MIMO雷达和传统相控阵雷达的单脉冲测角精度,得到了准确的测角误差函数表达式。通过计算机仿真,验证了理论分析的正确性,并在相同信噪比条件下,对两种模式下的测角精度进行了比较。 展开更多
关键词 多输入多输出雷达 比幅单脉冲测角 精度分析 全微分法
在线阅读 下载PDF
靶段定向井轨道设计方法 被引量:6
12
作者 崔红英 王德金 +1 位作者 林雍森 张建国 《石油钻探技术》 CAS 北大核心 2000年第6期8-10,共3页
提出了靶段定向井的概念 ,给出了靶段定向井两维或三维轨道设计的判据。着重对三维靶段定向井剖面设计方法进行了研究 ,给出了选择靶段定向井轨道类型的方法 ,而且给出了计算实例 。
关键词 油田 定向井 井眼轨迹 设计 全角变化率
在线阅读 下载PDF
制导控制一体化有限时间收敛控制算法 被引量:2
13
作者 张旭 雷虎民 +2 位作者 董飞垚 邵雷 翟岱亮 《空军工程大学学报(自然科学版)》 CSCD 北大核心 2015年第5期5-10,共6页
针对拦截高速机动目标的需求,研究了一种完全制导控制一体化有限时间收敛控制算法。首先,根据传统完全制导控制一体化模型,推导了导弹完全制导控制一体化视线角速率有限时间收敛模型;其次,构造了带补偿函数的非线性滑模切换函数,根据有... 针对拦截高速机动目标的需求,研究了一种完全制导控制一体化有限时间收敛控制算法。首先,根据传统完全制导控制一体化模型,推导了导弹完全制导控制一体化视线角速率有限时间收敛模型;其次,构造了带补偿函数的非线性滑模切换函数,根据有限时间收敛终端滑模控制理论,设计了基于完全制导控制一体化的有限时间收敛控制算法,并通过自适应方法对系统不确定性的最大值进行了估计、运用高阶滑模微分器对视线角速率和弹目相对距离的高阶导数进行了解算;最后,仿真结果表明,与一般的控制算法相比,论文所设计的有限时间收敛控制算法能够达到视线角速率有限时间收敛,且具有更小的脱靶量和更短的飞行时间。 展开更多
关键词 导弹完全制导控制一体化 视线角速率 有限时间收敛 控制算法
在线阅读 下载PDF
全站仪后方交会测量在数字化测图中的应用 被引量:3
14
作者 崔有祯 李长青 《北京工业职业技术学院学报》 2010年第4期6-7,共2页
介绍了全站仪后方交会测量的原理、解算与检核方法,结合其在数字化测图中的应用,全站仪后方交会测量作业方便、精度可靠,通过实践证明了其实用性。
关键词 图根点 全站仪后方交会测量 精度
在线阅读 下载PDF
氢原子的磁矩——对自旋的讨论之一 被引量:9
15
作者 许方官 高春媛 《大学物理》 2000年第11期10-13,共4页
利用氢原子的相对论性波动方程解计算了氢原子的磁矩 .结果表明 ,现行量子理论中所谓的总磁矩实际上都是由电子的轨道运动产生的 。
关键词 磁矩 自旋 轨道角动量 总角动量 氢原子
在线阅读 下载PDF
电子在均匀磁场中的状态——对自旋的讨论之二 被引量:4
16
作者 许方官 高春媛 《大学物理》 2000年第12期17-21,共5页
求得了在均匀磁场中的电子沿着磁场方向的动量、角动量分量和能量的共同本征态 .计算了电子产生的磁矩 。
关键词 磁矩 自旋 轨道角动量 电子 均匀磁场
在线阅读 下载PDF
^(10)B(n,α)~7Li反应角分布和总截面测量
17
作者 唐国有 张松柏 +8 位作者 张国辉 陈金象 施兆民 袁竞 陈泽民 陈迎堂 Gledenov Yu M Sedysheva M Khuuknenkhuu G 《核技术》 CAS CSCD 北大核心 2003年第10期804-808,共5页
用屏栅电离室测量了^(10)B(n,α)~7Li反应出射α粒子的角分布和总截面。实验结果表明:入射中子能量为4—6.5 MeV时,出射的α粒子角分布明显后倾,且后倾趋势随入射中子能量的增加而变大。
关键词 屏栅电离室 10B(n α)^7Li反应 角分布 总截面
在线阅读 下载PDF
用衰减全反射(ATR)及拟合法对固体表面物理性质的研究
18
作者 刘军民 《光子学报》 EI CAS CSCD 2000年第2期161-165,共5页
提出了一种利用光学中全反射衰减特性及拟合法对介质上蒸镀的金属薄膜物理性质进行研究的方法 ,并运用该方法对金属薄膜的厚度和复介电常量进行了精确测定 。
关键词 衰减全反射 表面物理 角度扫描 拟合法 金属薄膜
在线阅读 下载PDF
用衰减全反射(ATR)研究金属薄膜的物理性质
19
作者 刘军民 陈敏 《南昌航空工业学院学报》 CAS 1999年第2期57-61,共5页
本文作者所设计的实验是利用光学中全反射衰减特性方法测量在介质上蒸镀的金属薄膜的厚度和各种频率下的复介电常数等物理性质,它可以精确测定100~1000范围内金属膜层的厚度和ε(ω)值,以及一些其它性质,是研究固体表面物... 本文作者所设计的实验是利用光学中全反射衰减特性方法测量在介质上蒸镀的金属薄膜的厚度和各种频率下的复介电常数等物理性质,它可以精确测定100~1000范围内金属膜层的厚度和ε(ω)值,以及一些其它性质,是研究固体表面物理的一种有效的方法和技术。 展开更多
关键词 衰减全反射 耦合共振 金属 薄膜 表面物理
在线阅读 下载PDF
后路全脊椎切除治疗胸腰椎陈旧性骨折角状后凸畸形的疗效观察
20
作者 雷洪俊 陈忠羡 +1 位作者 薛忠林 付朝华 《白求恩军医学院学报》 2013年第2期108-109,共2页
目的探讨后路全脊椎切除治疗胸腰椎陈旧性骨折角状后凸畸形的手术方法及临床疗效。方法 15例胸腰椎陈旧性骨折角状后凸畸形患者采用后路全脊椎切除术,术后随访6~36个月,观察其临床症状缓解、手术前后后凸Cobb角度变化及Frankel分级情... 目的探讨后路全脊椎切除治疗胸腰椎陈旧性骨折角状后凸畸形的手术方法及临床疗效。方法 15例胸腰椎陈旧性骨折角状后凸畸形患者采用后路全脊椎切除术,术后随访6~36个月,观察其临床症状缓解、手术前后后凸Cobb角度变化及Frankel分级情况。结果术后患者临床症状均得到明显缓解,术前后凸Cobb角为(51.2±4.9)度,术后经随访恢复为(11.2±1.7)度,术后后凸Cobb角度<术前(P<0.01),且术后Frankel分级明显降低。结论后路全脊椎切除结合椎弓根内固定与椎板减压治疗胸腰椎陈旧性骨折角状后凸畸形效果显著。 展开更多
关键词 后路全脊椎切除术 胸腰椎陈旧性骨折角状后凸畸形 手术方法
暂未订购
上一页 1 2 3 下一页 到第
使用帮助 返回顶部