期刊文献+
共找到199,814篇文章
< 1 2 250 >
每页显示 20 50 100
Evaluation of polycarbonate films as detection materials for high‑dose electron beam radiation detection
1
作者 Ke Wang Xiao‑Dong Wang Xiong‑Hui Fei 《Nuclear Science and Techniques》 2026年第1期141-151,共11页
In this study,the dosimetric characteristics(thickness applicability,preheating time,temperature and humidity dependence,in-batch uniformity,readout reproducibility,dose linearity,self-decay,and electron energy respon... In this study,the dosimetric characteristics(thickness applicability,preheating time,temperature and humidity dependence,in-batch uniformity,readout reproducibility,dose linearity,self-decay,and electron energy response)of engineered polycarbonate films irradiated with an electron beam(0–600 kGy)were investigated using photoluminescence spectroscopy.The results show a linear relationship between photoluminescence intensity and radiation dose when the thickness of the polycarbonate film is 0.3 mm.A higher fluorescence intensity can be obtained by preheating at 60℃ for 180 min before photoluminescence spectrum analysis.As the temperature during spectral testing and the ambient humidity(during and after irradiation)increased,the photoluminescence intensity of the polycarbonate films decreased.The photoluminescence intensity deviation of the polycarbonate films produced within the same batch at 100 kGy is 2.73%.After ten times of repeated excitations and readouts,the coefficients of variation in photoluminescence intensity are less than 8.6%,and the linear correlation coefficient between photoluminescence intensity and irradiation dose is 0.965 in the dose capture range of 20–600 kGy.Within 60 days of irradiation,the photoluminescence intensity of the polycarbonate film decreased to 60%of the initial value.The response of the 0.3 mm polycarbonate films to electron beams with energies exceeding 3.5 MeV does not differ significantly.This comprehensive analysis indicates the potential of polycarbonate films as a high-radiation dose detection material. 展开更多
关键词 Electron beam irradiation POLYCARBONATE Dose detection Radiophotoluminescence Dosimetric characteristics
在线阅读 下载PDF
Muscle mass correlates with rocuronium distribution volume and guides dose optimization in obese colorectal cancer patients
2
作者 Zhan-Wen Li Zhe Liu Sheng-Qun Liu 《World Journal of Gastrointestinal Oncology》 2026年第1期176-189,共14页
BACKGROUND Perioperative anesthesia management of obese patients presents significant challenges as traditional total body weight-based dosing fails to achieve optimal anesthetic effects due to altered pharmacokinetic... BACKGROUND Perioperative anesthesia management of obese patients presents significant challenges as traditional total body weight-based dosing fails to achieve optimal anesthetic effects due to altered pharmacokinetic characteristics including abnormal drug distribution and clearance.Rocuronium exhibits markedly different distribution patterns in obese patients,with conventional weight correction methods inadequately addressing individual muscle mass variations that critically influence drug distribution.AIM To investigate the quantitative relationship between skeletal muscle index(SMI)and rocuronium distribution volume in obese colorectal cancer patients,establish a population pharmacokinetic model,and develop individualized dosing strategies based on muscle mass.METHODS A retrospective cohort study was conducted,including 100 obese patients(body mass index≥30 kg/m^(2))who underwent elective radical colorectal cancer surgery at our hospital from June 2023 to January 2025.Skeletal muscle mass was measured using InBody 260 body composition analyzer and SMI was calculated to assess muscle mass,with male SMI<7.0 kg/m^(2) and female SMI<5.7 kg/m^(2)as diagnostic criteria for sarcopenia.Plasma rocuronium concentrations were detected by liquid chromatography-tandem mass spectrometry/mass spectrometry,and nonlinear mixed-effect modeling was used to establish population pharmacokinetic modeling.Stepwise regression was used to screen covariates,and dosing regimens were optimized through Monte Carlo simulation.The primary endpoint was targeted plasma concentration achievement rate,and the secondary endpoint was postoperative residual muscle relaxation incidence.RESULTS Among 100 patients,35(35.0%)had sarcopenia and 65(65.0%)did not.Patients in the sarcopenia group were older(64.1±9.8 years vs 54.2±10.9 years,P<0.001)and had significantly lower SMI(6.2±0.8 kg/m^(2)vs 8.4±1.2 kg/m^(2),P<0.001).SMI showed strong positive correlation with rocuronium steady-state distribution volume(r=0.718,P<0.001)and moderate negative correlation with clearance(r=-0.502,P<0.001).A two-compartment population pharmacokinetic model was successfully established,with SMI being the most important covariate affecting central compartment distribution volume(△OFV=-41.2,P<0.001).Model validation showed bootstrap successful convergence rate of 92.3%,and 92.1%of observed values fell within prediction intervals in predicted concentration versus predicted concentration.The SMI-based individualized dosing regimen improved target exposure achievement rate from 82.0%in traditional regimen to 93.5%(P=0.009),and reduced postoperative residual muscle relaxation incidence from 13.0%to 3.5%(P=0.018).The sarcopenia group showed the most significant improvement in achievement rate,from 71.4%to 93.8%(P=0.017).CONCLUSION SMI shows strong correlation with rocuronium distribution volume in obese colorectal cancer patients and is a key factor affecting drug distribution.SMI-based individualized dosing strategies can significantly improve target exposure achievement rate and reduce postoperative residual muscle relaxation incidence,providing scientific evidence for precision anesthesia management in obese patients. 展开更多
关键词 Obesity ROCURONIUM Skeletal muscle index Population pharmacokinetics Individualized dosing Colorectal cancer SARCOPENIA
暂未订购
基于音视频信息融合与Self-Attention-DSC-CNN6网络的鲈鱼摄食强度分类方法 被引量:4
3
作者 李道亮 李万超 杜壮壮 《农业机械学报》 北大核心 2025年第1期16-24,共9页
摄食强度识别分类是实现水产养殖精准投喂的重要环节。现有的投喂方式存在过度依赖人工经验判断、投喂量不精确、饲料浪费严重等问题。基于多模态融合的鱼类摄食程度分类能够综合不同类型的数据(如:视频、声音和水质参数),为鱼群的投喂... 摄食强度识别分类是实现水产养殖精准投喂的重要环节。现有的投喂方式存在过度依赖人工经验判断、投喂量不精确、饲料浪费严重等问题。基于多模态融合的鱼类摄食程度分类能够综合不同类型的数据(如:视频、声音和水质参数),为鱼群的投喂提供更加全面精准的决策依据。因此,提出了一种融合视频和音频数据的多模态融合框架,旨在提升鲈鱼摄食强度分类性能。将预处理后的Mel频谱图(Mel Spectrogram)和视频帧图像分别输入到Self-Attention-DSC-CNN6(Self-attention-depthwise separable convolution-CNN6)优化模型进行高层次的特征提取,并将提取的特征进一步拼接融合,最后将拼接后的特征经分类器分类。针对Self-Attention-DSC-CNN6优化模型,基于CNN6算法进行了改进,将传统卷积层替换为深度可分离卷积(Depthwise separable convolution,DSC)来达到减少计算复杂度的效果,并引入Self-Attention注意力机制以增强特征提取能力。实验结果显示,本文所提出的多模态融合框架鲈鱼摄食强度分类准确率达到90.24%,模型可以有效利用不同数据源信息,提升了对复杂环境中鱼群行为的理解,增强了模型决策能力,确保了投喂策略的及时性与准确性,从而有效减少了饲料浪费。 展开更多
关键词 鲈鱼 摄食强度分类 多模态融合 self-Attention-DSC-CNN6
在线阅读 下载PDF
双定位像联合Care Dose 4D技术在PET/CT体部检查中的临床价值
4
作者 樊俊甫 黄伟 +3 位作者 杨田硕 朱荣华 魏静 陶维静 《医学研究与战创伤救治》 北大核心 2025年第11期1170-1175,共6页
目的研究双定位像联合Care Dose 4D技术在PET/CT体部扫描中的临床应用价值。方法收集2022年7月5日-2023年9月23日在南京医科大学附属淮安第一医院行Care Dose 4D模式下单定位像法(前后位)和双定位像法(前后位和侧位)2次PET/CT扫描的120... 目的研究双定位像联合Care Dose 4D技术在PET/CT体部扫描中的临床应用价值。方法收集2022年7月5日-2023年9月23日在南京医科大学附属淮安第一医院行Care Dose 4D模式下单定位像法(前后位)和双定位像法(前后位和侧位)2次PET/CT扫描的120例患者。计算患者体重指数(BMI)。设Care Dose 4D模式下单定位像法扫描为单定位像组,Care Dose 4D模式下双定位像法扫描为双定位像组。根据BMI值将患者再分为四个亚组:过低组(BMI<18.5 kg/m^(2))、正常组(18.5 kg/m^(2)≤BMI<25 kg/m^(2))、超重组(25 kg/m^(2)≤BMI<30 kg/m^(2))和肥胖组(BMI≥30 kg/m^(2))。记录患者2种扫描模式下毫安秒(mAs)、CT容积剂量指数(CTDI_(vol))、剂量长度乘积(DLP)并计算有效剂量(ED)。通过图像信噪比(SNR)、对比信噪比(CNR)客观评价图像质量;另外由2名高年资核医学诊断医师采用双盲法主观评价图像质量。采用配对样本t检验比较单定位像组及双定位像组的CTDI_(vol)、DLP、ED值。计算每个患者2次扫描辐射剂量差值,记为ΔCTDI_(vol)、ΔDLP及ΔED;分析不同BMI亚组(过低组、正常组、超重组及肥胖组)ΔCTDI_(vol)、ΔDLP及ΔED有无统计学差异。结果图像质量方面,客观评价除舌骨层面外,双定位像组图像SNR、CNR较单定位像组下降,其中左肾门层面及髂总动脉分叉层面差异具有统计学意义(P<0.05);医师主观评价两组图像质量均能满足临床诊断需求。辐射剂量方面,双定位像组[CTDI_(vol):(8.14±1.64)mGy、DLP:(704.89±146.91)mGy·cm、ED:(12.69±2.64)mSv]较单定位像组[CTDI_(vol):(9.49±2.05)mGy、DLP:(822.24±180.31)mGy·cm、ED:(14.80±3.25)mSv]明显下降,差异具有统计学意义(P<0.01)。随BMI升高患者辐射剂量下降越明显,其中正常组与超重组、正常组与肥胖组间ΔCTDI_(vol)、ΔDLP及ΔED差异均具有统计学意义(P<0.05)。结论双定位像联合Care Dose 4D技术应用于PET/CT体部扫描,在保证图像质量前提下,可有效降低患者CT辐射剂量。 展开更多
关键词 Care Dose 4D技术 定位像 辐射剂量 图像质量 PET/CT
暂未订购
基于TV正则化约束的Self2Self地震数据插值去噪一体化方法
5
作者 张蕴 杨锴 王本锋 《地球物理学报》 北大核心 2025年第9期3575-3587,共13页
实际采集的地震数据不可避免地受到随机噪声的干扰,并常常伴随着数据缺失,严重降低了地震数据的信噪比与横向连续性,继而降低后续地震数据处理及反演的精度.本文基于Self2Self无监督学习框架,针对含噪非规则地震数据,设计无监督地震数... 实际采集的地震数据不可避免地受到随机噪声的干扰,并常常伴随着数据缺失,严重降低了地震数据的信噪比与横向连续性,继而降低后续地震数据处理及反演的精度.本文基于Self2Self无监督学习框架,针对含噪非规则地震数据,设计无监督地震数据插值去噪一体化方法,并基于地震道之间的相关性优化数据采样策略,对含噪的非规则地震数据进行整道伯努利采样,构建训练数据集;为降低随机噪声对插值重建的负面影响,在损失函数中引入全变分正则化项,确保恢复地震信号具有良好的横向连续性.针对异常噪声干扰,探讨了异常噪声识别-剔除策略,结合插值去噪一体化方法可以有效提高地震数据质量.不同数值算例验证了无监督Self2Self方法在地震数据插值重建及噪声衰减中的有效性,为后续地震数据处理和解释提供良好的数据支撑. 展开更多
关键词 随机噪声衰减 数据重建 无监督学习 self2self方法 TV正则化
在线阅读 下载PDF
基于Self-Attention和TextCNN-BiLSTM的中文评论文本情感分析模型 被引量:4
6
作者 龙宇 李秋生 《石河子大学学报(自然科学版)》 北大核心 2025年第1期111-121,共11页
目前关于中文评论文本的情感分类方法大都无法充分捕捉到句子的全局语义信息,同时也在长距离的语义连接或者情感转折理解上具有局限性,因而导致情感分析的准确度不高。针对这个问题,本文提出一种融合SelfAttention和TextCNN-BiLSTM的文... 目前关于中文评论文本的情感分类方法大都无法充分捕捉到句子的全局语义信息,同时也在长距离的语义连接或者情感转折理解上具有局限性,因而导致情感分析的准确度不高。针对这个问题,本文提出一种融合SelfAttention和TextCNN-BiLSTM的文本情感分析方法。该方法首先采用文本卷积神经网络(TextCNN)来提取局部特征,并利用双向长短期记忆网络(BiLSTM)来捕捉序列信息,从而综合考虑了全局和局部信息,在特征融合阶段,再采用自注意力机制来动态地融合不同层次的特征表示,对不同尺度特征进行加权,从而提高重要特征的响应。实验结果表明,所提出的模型在家电商品中文评论语料和谭松波酒店评论语料数据集上的准确率分别达到93.79%和90.05%,相较于基准模型分别提高0.69%~3.59%和4.44%~11.70%,优于传统的基于卷积神经网络(Convolutional Neural Networks, CNN)、BiLSTM或CNN-BiLSTM等的情感分析模型。 展开更多
关键词 自注意力机制 中文评论文本 深度学习 情感分析
在线阅读 下载PDF
3D medical image segmentation using the serial-parallel convolutional neural network and transformer based on crosswindow self-attention 被引量:1
7
作者 Bin Yu Quan Zhou +3 位作者 Li Yuan Huageng Liang Pavel Shcherbakov Xuming Zhang 《CAAI Transactions on Intelligence Technology》 2025年第2期337-348,共12页
Convolutional neural network(CNN)with the encoder-decoder structure is popular in medical image segmentation due to its excellent local feature extraction ability but it faces limitations in capturing the global featu... Convolutional neural network(CNN)with the encoder-decoder structure is popular in medical image segmentation due to its excellent local feature extraction ability but it faces limitations in capturing the global feature.The transformer can extract the global information well but adapting it to small medical datasets is challenging and its computational complexity can be heavy.In this work,a serial and parallel network is proposed for the accurate 3D medical image segmentation by combining CNN and transformer and promoting feature interactions across various semantic levels.The core components of the proposed method include the cross window self-attention based transformer(CWST)and multi-scale local enhanced(MLE)modules.The CWST module enhances the global context understanding by partitioning 3D images into non-overlapping windows and calculating sparse global attention between windows.The MLE module selectively fuses features by computing the voxel attention between different branch features,and uses convolution to strengthen the dense local information.The experiments on the prostate,atrium,and pancreas MR/CT image datasets consistently demonstrate the advantage of the proposed method over six popular segmentation models in both qualitative evaluation and quantitative indexes such as dice similarity coefficient,Intersection over Union,95%Hausdorff distance and average symmetric surface distance. 展开更多
关键词 convolution neural network cross window self‐attention medical image segmentation transformer
在线阅读 下载PDF
基于VMD-Self-attention-LSTM的水闸深基坑变形智能预测方法 被引量:2
8
作者 张伟 仇建春 +5 位作者 夏国春 姚兆仁 吴昊 刘占午 王昱锦 朱新宇 《水电能源科学》 北大核心 2025年第1期99-102,196,共5页
针对水闸深基坑变形监测数据具有非稳定性的特点,提出了基于VMD-Self-attention-LSTM的水闸深基坑变形预测方法。该方法分为三个主要模块,第一模块采用VMD算法自适应调整变形分解模数,将原始变形数据分解为若干具有明显周期规律的分量,... 针对水闸深基坑变形监测数据具有非稳定性的特点,提出了基于VMD-Self-attention-LSTM的水闸深基坑变形预测方法。该方法分为三个主要模块,第一模块采用VMD算法自适应调整变形分解模数,将原始变形数据分解为若干具有明显周期规律的分量,有效解决变形数据的非稳定性,为提升变形预测精度奠定初步基础;第二模块,在传统LSTM算法基础上进一步发展Self-attention-LSTM方法,提升模型对基坑变形样本的时序关系挖掘能力,进而提升基坑变形预测精度;第三模块,将各分量对应的变形预测结果重构得到最终预测值。实例分析可知,所提方法有效解决了非稳定特性给变形预测精度带来的不利影响,与VMD-LSTM、Self-attention-LSTM、LSTM等深度学习方法相比,VMD-Self-attention-LSTM的预测精度最大提升41.49%,与BP、ELM等传统机器学习算法相比,预测精度最大提升50.43%,为水闸深基坑安全监控模型的构建提供了新思路。 展开更多
关键词 水闸深基坑 变形预测 VMD self-attention-LSTM
原文传递
Self肽与Tat肽协同修饰阿霉素脂质体的制备及其抗肿瘤作用
9
作者 段学辉 刘含笑 +4 位作者 李旭 任甜莹 杜燕 楚新垒 唐宜轩 《广东药科大学学报》 2025年第4期23-31,共9页
目的采用CD47蛋白衍生的Self肽提高Tat肽修饰脂质体的免疫生物相容性和内皮细胞渗透性,以提升其包载阿霉素后的抗肿瘤疗效。方法通过薄膜水化法制备常规脂质体(Lip)、Self肽修饰脂质体(S-Lip)、Tat修饰脂质体(T-Lip)及双肽共修饰脂质体(... 目的采用CD47蛋白衍生的Self肽提高Tat肽修饰脂质体的免疫生物相容性和内皮细胞渗透性,以提升其包载阿霉素后的抗肿瘤疗效。方法通过薄膜水化法制备常规脂质体(Lip)、Self肽修饰脂质体(S-Lip)、Tat修饰脂质体(T-Lip)及双肽共修饰脂质体(ST-Lip),并通过主动载药法包载阿霉素。采用透射电镜和动态光散射表征形貌与粒径并测定包封率。通过荧光显微成像评估巨噬细胞体外摄取,利用流式细胞术分析脂质体与脾脏免疫细胞的相互作用,并进一步考察脂质体与内皮细胞的相互作用及体内抗肿瘤疗效。结果多肽修饰未显著改变脂质体形貌与粒径,各组药物包封率均>80%。ST-Lip相较T-Lip显著抑制巨噬细胞内吞(P<0.01),体内免疫识别结果显示ST-Lip组脾脏巨噬细胞和B细胞的脂质体阳性比例相比T-Lip分别降低了约16.7%及39.0%。此外,Self肽与Tat肽产生协同效应,使内皮细胞摄取量相比Lip提高1.77倍,对荷瘤小鼠抑瘤率达87%。结论CD47衍生Self肽可协同增强Tat修饰脂质体的免疫相容性及内皮细胞渗透能力,为肿瘤靶向递送系统开发提供新策略。 展开更多
关键词 脂质体 细胞穿膜肽 Tat肽 self 阿霉素
暂未订购
An Inquiry Into the Effect of Peers on L2 Motivation Under the L2 Motivational Self System
10
作者 Xiaoyu Zhang 《Chinese Journal of Applied Linguistics》 2025年第2期207-227,320,321,共23页
Second language(L2)motivation has been a topic which receives intensive attention.However,the peer effect on L2 motivation is insufficiently researched,although it is considered a crucial factor which may significantl... Second language(L2)motivation has been a topic which receives intensive attention.However,the peer effect on L2 motivation is insufficiently researched,although it is considered a crucial factor which may significantly mediate learners’L2 motivation.Hence,the current study adopted Dörnyei’s L2 Motivational Self System(L2MSS)as a theoretical framework and investigated in which specific aspects peers might affect the learners’L2 motivation and whether such effect was long-lasting.The research was designed as a small-scale qualitative study which was located in a language-focused experimental class project in China.Ten participants were recruited and individual interviews were conducted.The results demonstrated that,first,peers could remarkably influence the L2 motivation possessed by the students in the experimental class since they tended to create a clearer ideal L2 self and a more powerful ought-to L2 self.Second,although they had both positive and negative views towards the curriculum,a motivated peer climate could alleviate the pressure caused by the curriculum and reinforce positive attitudes.Third,such peer effect was not long-lasting.Based on the research results,pedagogical implications were proposed in terms of establishing a positive peer group and adjusting the emphasis of the curriculum. 展开更多
关键词 peer effect L2 motivation ideal L2 self ought-to L2 self curriculum
在线阅读 下载PDF
CARE Dose 4D联合CARE kV技术在胸部CT扫描中的辐射剂量降低研究
11
作者 张佩聪 《影像技术》 2025年第1期62-67,共6页
目的:探究在胸部CT扫描过程中启用CARE Dose 4D联合CARE kV技术对降低CT辐射剂量的有效性。方法:回顾性分析2023年1月至12月期间在本院进行胸部CT扫描的100例患者影像资料,根据是否应用CARE Dose 4D联合CARE kV技术将患者分为A组(常规胸... 目的:探究在胸部CT扫描过程中启用CARE Dose 4D联合CARE kV技术对降低CT辐射剂量的有效性。方法:回顾性分析2023年1月至12月期间在本院进行胸部CT扫描的100例患者影像资料,根据是否应用CARE Dose 4D联合CARE kV技术将患者分为A组(常规胸部CT扫描,n=50例)和B组(应用CARE Dose 4D联合CARE kV技术,n=50例)。采用德国西门子SOMATOM Force双源CT,详细设置包括自动毫安秒调节、120KV管电压等参数。比较两组的辐射剂量指标(CTDI(剂量指数)、DLP(剂量长度乘积)、ED(有效剂量))、图像质量客观评价(平均CT值、噪声(SD)、信号噪声比(SNR))和主观评分。结果:B组的辐射剂量指标显著低于A组(P<0.05);而两组的图像质量对比上无显著差异(P>0.05)。结论:胸部CT扫描中应用CARE Dose 4D联合CARE kV技术能显著减少辐射剂量,同时保持高质量的CT图像,为临床检查提供了一种安全有效的方法,为辐射防护最优化原则的实施提供了有力支持,具有广阔的临床应用前景。 展开更多
关键词 CARE Dose4D联合CARE kV技术 胸部CT扫描 辐射剂量 图像质量
暂未订购
Simple Insulin Dose Adjustment Using 3-3-1 Algorithm in Japanese Patients with Type 2 Diabetes: Start Kanazawa Study (Self-Titration Aggressive Algorithm with Glargine Trial) 被引量:1
12
作者 Kenji D. Furukawa Naoto Yamaaki +2 位作者 Aya Fujimoto Kiminori Ohyama Hiroaki Muramoto 《Journal of Diabetes Mellitus》 2016年第3期197-203,共7页
We implemented a 3-3-1 algorithm in order to provide safe and simple self-titration in patients who newly initiated BOT as well as who were already on BOT and evaluated its utility in clinical setting. A total of 46 p... We implemented a 3-3-1 algorithm in order to provide safe and simple self-titration in patients who newly initiated BOT as well as who were already on BOT and evaluated its utility in clinical setting. A total of 46 patients, 21 patients in the newly-initiated group and 25 patients in the existing BOT group performed dose adjustment using 3-3-1 algorithm. HbA1c was significantly improved 4 weeks after the initiation from 8.5% ± 1.2% at baseline to 7.3% ± 0.7% at the final evaluation (p  0.01, vs. Baseline). The average daily insulin units increased throughout the study period from 10.1 ± 6.7 at baseline to 14.6 ± 8.9 units at the final evaluation. Weight didn’t significantly change throughout the study (p = 0.12). The incidents of hypoglycemia were 0.8/month during the insulin dose self-adjustment period and 0.4/month during the follow-up period. The 3-3-1 algorithm using insulin glargine provided a safe and simple dose adjustment and demonstrated its utility in patients who were newly introduced to insulin treatment as well as who were already on BOT. 展开更多
关键词 GLARGINE self-Titration BOT T2DM INSULIN 3-3-1 Algorithm
暂未订购
Ultra-low dose computed tomography chest vs chest radiography in paediatric primary ciliary dyskinesia:A prospective study
13
作者 Michael G Waldron Patrick W O'Regan +13 位作者 Michael Lane Sahil S Shet Eid Kakish Fiachra Moloney Niamh Moore Mary Jane Murphy Louise Beagan Barry J Plant David Mullane Muireann Ni Chroinin David J Ryan Kevin O'Regan Stephen P Power Michael M Maher 《World Journal of Radiology》 2025年第8期64-73,共10页
BACKGROUND Primary ciliary dyskinesia(PCD)is a rare condition characterised by dysmotile,immotile,or absent cilia.As a result of the impairment in respiratory mucociliary clearance,patients with PCD typically develop ... BACKGROUND Primary ciliary dyskinesia(PCD)is a rare condition characterised by dysmotile,immotile,or absent cilia.As a result of the impairment in respiratory mucociliary clearance,patients with PCD typically develop neonatal respiratory distress,nasal congestion,otitis media and recurrent respiratory infections leading to bronchiectasis and structural lung changes.These changes have been shown by chest computed tomography(CT)to develop in infancy and early childhood.Recent development and refinement of radiation-reducing CT techniques have allowed significant radiation dose reductions,with chest CT doses now in the range of chest radiography(CR).AIM To evaluate the efficacy of ultra-low dose CT(ULDCT)chest in identifying pulmonary changes within a PCD paediatric patient cohort.METHODS Paediatric patients with PCD who presented for routine clinical outpatient follow-up within the study period,were eligible for inclusion in the study.ULDCT and CR were performed on these patients and the results compared.Comparison metrics included radiation dose,subjective and objective image quality and disease severity.RESULTS Six paediatric patients(mean age 9 years)underwent clinically indicated ULDCT chest examinations and CR for surveillance of their PCD.The mean effective dose was 0.08±0.02 mSv,a dose that approximates that of a frontal and lateral chest radiograph.The average Brody II score across the entire cohort was 12.92,with excellent interrater reliability and intra-class correlation coefficient(ICC)of 0.98.The average Chrispin-Norman score on CR was 1 with excellent inter-rater reliability and ICC of 0.92.CONCLUSION ULDCT demonstrates superior diagnostic capabilities,minimal radiation dose penalty,and high interobserver reliability in comparison to CR.Thus,we advocate for ULDCT to be the preferred modality for surveillance imaging in paediatric PCD. 展开更多
关键词 Primary ciliary dyskinesia Ultra-low dose computed tomography Chest radiography Radiation dose Image quality
暂未订购
Taking Care of Yourself
14
作者 Ruth Devlin 《空中英语教室(初级版.大家说英语)》 2025年第6期21-23,52,共4页
Everyone is busy.But it's easy to be too busy.Then you may feel anxious or stressed.You need to take care of yourself.How can you do that?First,make time to text or call your family and friends.They care about you... Everyone is busy.But it's easy to be too busy.Then you may feel anxious or stressed.You need to take care of yourself.How can you do that?First,make time to text or call your family and friends.They care about you and can support you.Get regular exercise. 展开更多
关键词 FRIENDS EXERCISE stress FAMILY self care ANXIETY
原文传递
Regional multi-center randomized trial of three vonoprazanamoxicillin dosing regimens for Helicobacter pylori eradication in Sichuan Province,China
15
作者 Chao-Qun Wu Xiu Zhou +19 位作者 Chang-Ping Li Qing-Ling He Zong-Hua Chen Shun-Bin Ding Lei Deng Lin-Lin Chen Kai Jiang Cheng-Kui Dong Lian Hu Guo-Bing Zhu Cheng-Gang Zhang Yan Zhang Li-Li Wu Wei Li Yi-Hong Mao Hua Zhang Xia Ai Yuan-Qing He Yan Ma Shuang-Yan He 《World Journal of Gastroenterology》 2025年第47期128-139,共12页
BACKGROUND Helicobacter pylori(H.pylori)infection is highly prevalent worldwide,and rising antibiotic resistance has reduced the efficacy of standard therapy,underscoring the need for simplified and better-tolerated r... BACKGROUND Helicobacter pylori(H.pylori)infection is highly prevalent worldwide,and rising antibiotic resistance has reduced the efficacy of standard therapy,underscoring the need for simplified and better-tolerated regimens.AIM To evaluate the efficacy,safety,and optimal dosing of vonoprazan(VPZ)-amoxicillin(AMO)dual therapy in a non-inferiority randomized trial for H.pylori eradication.METHODS In this multi-center,randomized trial conducted at 17 hospitals in Sichuan Province,China,1717 adults with confirmed infection were assigned(1:1:1)to 14-day regimens:(1)VPZ 20 mg BID+AMO 0.5 g QID;(2)0.75 g QID;or(3)1.0 g TID.The primary endpoint was the eradication rate based on intention-to-treat(ITT)and per-protocol(PP)analyses;secondary endpoints included adverse events(AEs)and treatment compliance.RESULTS Eradication rates were consistently high(92.35%-97.43%).In the 0.5 g QID group,ITT and PP eradication rates were 93.3%(95%CI:91.2-95.1)and 97.4%(95%CI:95.7-98.5),respectively,with no significant differences among groups(P>0.05).Compliance ranged from 98.1%to 98.3%,and AEs were infrequent(5.2%-7.5%),predominantly mild gastrointestinal symptoms,which occurred least often in the 0.5 g QID group.CONCLUSION VPZ-AMO dual therapy achieved excellent eradication,safety,and patient compliance.All regimens were similarly effective,whereas the 0.5 g QID dosing strategy offered the most favorable balance of efficacy and tolerability,supporting its use as a first-line option in high-prevalence settings. 展开更多
关键词 Vonoprazan AMOXICILLIN Helicobacter pylori Potassium-competitive acid blockers Dose
暂未订购
Improve Yourself
16
作者 康华婕 钟文爱(指导) 《中学生英语》 2025年第3期7-7,共1页
The meaning of growth is increasing experiences and self-improvement. No one’s life is always good, and many people have the power to change it but don’t take action. It’s better to change ourselves than to try to ... The meaning of growth is increasing experiences and self-improvement. No one’s life is always good, and many people have the power to change it but don’t take action. It’s better to change ourselves than to try to change the people and things around us.Self-improvement is very important. First, it helps us to become more confident. When we make progress, we will feel more confident. And this confidence will make us do more and do better. 展开更多
关键词 increasing experiences self improvement
在线阅读 下载PDF
Fun at a Self-Photo Studio!
17
作者 Ruth Devlin 《空中英语教室(初级版.大家说英语)》 2025年第6期46-47,56,共3页
Are you tred of regular selfies?Try a self-photo studio!The lights and camera are ready for you.At the studio,you can fix your hair.There are clothes and props.You can use those and take fun photos.Bring your friends ... Are you tred of regular selfies?Try a self-photo studio!The lights and camera are ready for you.At the studio,you can fix your hair.There are clothes and props.You can use those and take fun photos.Bring your friends with you.Then you can take photos together.Pose in silly ways and have fun!You can take the photos home and remember your good time. 展开更多
关键词 camera CLOTHES hair fixing selfies lights fun photos PROPS self photo studio
原文传递
Correction to Solvent-Resistant Wearable Triboelectric Nanogenerator for Energy-Harvesting and Self-Powered Sensors
18
《Energy & Environmental Materials》 2025年第3期327-327,共1页
Yongtao Yu,Yuelin Yu et al.Solvent-Resistant Wearable Triboelectric Nanogenerator for Energy-Harvesting and Self-Powered Sensors.Energy Environ.Mater.2024,7,e12700.On page 4 of this article,the first paragraph of 2.4,... Yongtao Yu,Yuelin Yu et al.Solvent-Resistant Wearable Triboelectric Nanogenerator for Energy-Harvesting and Self-Powered Sensors.Energy Environ.Mater.2024,7,e12700.On page 4 of this article,the first paragraph of 2.4,line 14(PDF version,same below),there is a spelling mistake of“sui,”.It should be changed to“suitable”.The denominator“dt”in the Equation(3)should be changed to“dt”. 展开更多
关键词 WEARABLE self powered sensors triboelectric nanogenerator solvent resistant energy harvesting
在线阅读 下载PDF
Exploring the critical therapeutic window:Dose-frequency optimization of human umbilical cord mesenchymal stem cells for preclinical asthma treatment
19
作者 Qiong-Hua Chen Jing-Yang Zheng +5 位作者 Yu-Qin Zhu Jun-Yao Zhang Chun-Yan Lin Xue-E Zhuang Jing Cheng Xiao-Yi Huang 《World Journal of Stem Cells》 2025年第9期190-199,共10页
BACKGROUND Current drugs primarily target inflammation control but do not reverse tissue remodeling changes for asthma.Human mesenchymal stem cells are known for their anti-inflammatory and tissue remodeling capabilit... BACKGROUND Current drugs primarily target inflammation control but do not reverse tissue remodeling changes for asthma.Human mesenchymal stem cells are known for their anti-inflammatory and tissue remodeling capabilities.However,limited research has explored the therapeutic impact of varying doses and frequencies of human umbilical cord blood-derived mesenchymal stem cells(HUC-MSCs)on established airway remodeling in experimental asthma.AIM To explore and optimize the dosage and administration frequency of HUC-MSCs in experimental models of ovalbumin(OVA)-induced asthma.METHODS BALB/c mice underwent sensitization and were challenged using OVA.Control animals were administered a saline solution following the same protocol.HUC-MSCs were identified using flow cytometry.HUC-MSCs at incremental dosages(1×105,2×105,4×105)were injected via tail veins on day 30(the second after the final stimulation).After comparing each group and determining the optimal dose,supplement the optimal dose twice on day 30 and day 33(the second and fifth day after the final stimulation).Bronchoalveolar lavage fluid(BALF)and serum were harvested for analysis of concentrations of interleukin-4(IL-4),IL-13,immunoglobulin E and interferon-gamma(IFN-γ)by enzyme-linked immunosorbent assay.Pharmacology of airways and lung functions were also evaluated to identify the optimal group.RESULTS The study shows that HUC-MSC transplantation ameliorates OVA-induced asthma by significantly reducing airway inflammation and obstruction in preclinical models.This effect is associated with decreased Th2 cytokines IL-4 and IL-13,and increased Th1 cytokine IFN-γ.The optimal dose of 2×105 cells/mouse was identified as the most effective in reducing local asthmatic airway inflammation and changing levels of IL-4,IL-13,and IFN-γin serum and BALF compared to other single doses of HUC-MSC.Multiple treatments with the medium dose(2×105 cells)of HUC-MSCs on days 30 and 33 yield the best pathological and lung function outcomes.However,double treatments do not reduce IL-4 and IL-13 expression or enhance IFN-γproduction in serum or BALF more effectively than a single medium dose.CONCLUSION HUC-MSCs effectively regulate pro-inflammatory mediators in serum and BALF,modulating airway remodeling and lung function.In this acute mouse asthma model,a single dosage of 2×105 is optimal,with more significant effects of decreasing airway obstruction requiring repeated administration. 展开更多
关键词 ASTHMA Human umbilical cord mesenchymal stem cells MOUSE DOSE FREQUENCY
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部