The strategy of expert system for high performance liquid chromatography was discussed, the attentions are mainly placed on the knowledge base for selection of column system, separation modes and detection modes in th...The strategy of expert system for high performance liquid chromatography was discussed, the attentions are mainly placed on the knowledge base for selection of column system, separation modes and detection modes in the analysis of amino acids, peptides and proteins.展开更多
A rapid, specific, sensitive, and precise reverse-phase HPLC method for the quantitative determination of process related and degradation impurities of Apixaban, an anticoagulant drug is described. The developed RP-HP...A rapid, specific, sensitive, and precise reverse-phase HPLC method for the quantitative determination of process related and degradation impurities of Apixaban, an anticoagulant drug is described. The developed RP-HPLC method was successfully applied to the analysis of both Apixaban drug substance and drug product. The chromatographic separation was achieved on a Sigma-Aldrich’s Ascentis Express®C18 (4.6 mm × 100 mm, 2.7 μ) HPLC column with a runtime of 40 min. Mobile phase-A and mobile phase-B were phosphate buffer and acetonitrile respectively. The column oven temperature was set at 35°C and photodiode array detector was set at 225 nm. Nine process related impurities (Imp-1 to Imp-9) have been detected in test sample of Apixaban by using newly developed RP-HPLC method. Forced degradation study was carried out under acidic, alkaline, oxidative, photolytic and thermal conditions to demonstrate the stability-indicating nature of the developed RP-HPLC method. The developed method was validated as per ICH guideline and found to be specific, precise, sensitive and robust.展开更多
Nicotine and cotinine in hair are good biomarkers for assessing long-term exposure to smoking. However, analytical devices such as GC/MS are associated with high cost and are not widely used. HPLC/UV is used widely in...Nicotine and cotinine in hair are good biomarkers for assessing long-term exposure to smoking. However, analytical devices such as GC/MS are associated with high cost and are not widely used. HPLC/UV is used widely in laboratories, but is unsuitable for measurement of minor constituents, except when using the column-switching method. Thus, we aimed to establish a simple, inexpensive and sensitive method based on HPLC/UV with column switching for measuring nicotine and cotinine in hair. First, we compared the presence and absence of a column selection unit. We then measured amounts of nicotine and cotinine in hair samples collected from the general population, and compared both the corresponding levels and the detection limits with those in previous studies. Finally, initial and running costs of HPLC/UV were compared with other analytical methods. As one of the results, the areas of nicotine and cotinine measured by HPLC/UV with column-switching method were 12.9 and 16.9 times greater, respectively, than those without the column-switching method. The amount of nicotine and cotinine in hair was significantly correlated to number of cigarettes smoked per day (r = 0.228, p = 0.040). In addition, the HPLC/UV method showed similar sensitivity and detection limit (nicotine, 0.10 ng/mg;cotinine, 0.08 ng/mg) as reported in previous studies. The cost of the HPLC/UV method is lower than that of other analytical methods. We were able to establish a low-cost method with good sensitivity for measuring nicotine and cotinine in hair. The HPLC/UV with a column-switching method will be useful as a first step in screening surveys in order to better understand the effects of smoking exposure.展开更多
Reversed-phase high-performance liquid chromatography (RP-HPLC) method with C4 column and C18 column for analyzing β-lactoglobulin and α-lactalbumin in bovine milk was developed and the performance and characteris...Reversed-phase high-performance liquid chromatography (RP-HPLC) method with C4 column and C18 column for analyzing β-lactoglobulin and α-lactalbumin in bovine milk was developed and the performance and characteristic of two columns were compared. Shiseido Proteonavi C4 column (250 mm×4.6 mm×5μm) and Shiseido CAPCELL PAK SG 300 C18 column (250 mm× 4.6 mm×5 μm) were used in the experiment. Phase A was composed of 0.1% (V/V) trifluoroacetic acid (TFA) in ultrapure water and Phase B (organic phase) was composed of 0.1% TFA in acetonitrile. Gradient elution was taken. Flow rate was 1 mL min-1. The detection wavelength was 215 nm. The injection volume was 20 μL and the column temperature was 30℃. The results showed that linear relationship was good and recovery of α-lactalbumin and β-lactoglobulin was 86.12%-104.38%, C18 column had stronger ability to resist acid and more stable, and the method with C4 column had excellent sensitivities and good separation.展开更多
A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were...A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were minced and mixed,and extracted with ultra pure water at 90℃ for 20 min. The 6-aminoquinolyl N-hydroxy-succinimidyl carbamate( AQC) was used as pre-column derivatization reagent. Gradient HPLC separation was performed on a C_(18) column( Symmetry C_(18),3. 9 mm × 15 cm,4 μm). Good linearity between concentrations and peak areas was achieved in the concentration range of 5. 0-250 μmol/L for 18 kinds of amino acids. The method was validated by the analysis of five replicates. The 18 kinds of amino acid standards were spiked in fresh tea leaf samples and the average recovery rate was 86. 25%-109. 05% with relative standard deviations( n = 5) ranging from 6. 03% to 10. 56%. The limit of detection( LOD) for the analytes was0. 05-1. 27 μmol/L. The method was successfully applied to the analysis of the 18 kinds of amino acids in fresh tea leaves from east Dongting and west Dongting mountains in Suzhou. The results indicate that the method is simple,rapid,precise and reliable.展开更多
High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral der...High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral derivatization was developed. Cheap and easy available aromatic acid chlorides were used as derivatization agents. Good to excellent separations of the enantiomers were achieved in all cases in relatively short analytical runs. It was shown that the enantiorecognition depends on the substituents both in the starting alcohol and in the acid chloride. The method presents an efficient alternative to the direct analyses on polysaccharide and cyclodextrine-derived stationary phases.展开更多
基金Project supported by the National Natural Science Foundation of China.
文摘The strategy of expert system for high performance liquid chromatography was discussed, the attentions are mainly placed on the knowledge base for selection of column system, separation modes and detection modes in the analysis of amino acids, peptides and proteins.
文摘A rapid, specific, sensitive, and precise reverse-phase HPLC method for the quantitative determination of process related and degradation impurities of Apixaban, an anticoagulant drug is described. The developed RP-HPLC method was successfully applied to the analysis of both Apixaban drug substance and drug product. The chromatographic separation was achieved on a Sigma-Aldrich’s Ascentis Express®C18 (4.6 mm × 100 mm, 2.7 μ) HPLC column with a runtime of 40 min. Mobile phase-A and mobile phase-B were phosphate buffer and acetonitrile respectively. The column oven temperature was set at 35°C and photodiode array detector was set at 225 nm. Nine process related impurities (Imp-1 to Imp-9) have been detected in test sample of Apixaban by using newly developed RP-HPLC method. Forced degradation study was carried out under acidic, alkaline, oxidative, photolytic and thermal conditions to demonstrate the stability-indicating nature of the developed RP-HPLC method. The developed method was validated as per ICH guideline and found to be specific, precise, sensitive and robust.
文摘Nicotine and cotinine in hair are good biomarkers for assessing long-term exposure to smoking. However, analytical devices such as GC/MS are associated with high cost and are not widely used. HPLC/UV is used widely in laboratories, but is unsuitable for measurement of minor constituents, except when using the column-switching method. Thus, we aimed to establish a simple, inexpensive and sensitive method based on HPLC/UV with column switching for measuring nicotine and cotinine in hair. First, we compared the presence and absence of a column selection unit. We then measured amounts of nicotine and cotinine in hair samples collected from the general population, and compared both the corresponding levels and the detection limits with those in previous studies. Finally, initial and running costs of HPLC/UV were compared with other analytical methods. As one of the results, the areas of nicotine and cotinine measured by HPLC/UV with column-switching method were 12.9 and 16.9 times greater, respectively, than those without the column-switching method. The amount of nicotine and cotinine in hair was significantly correlated to number of cigarettes smoked per day (r = 0.228, p = 0.040). In addition, the HPLC/UV method showed similar sensitivity and detection limit (nicotine, 0.10 ng/mg;cotinine, 0.08 ng/mg) as reported in previous studies. The cost of the HPLC/UV method is lower than that of other analytical methods. We were able to establish a low-cost method with good sensitivity for measuring nicotine and cotinine in hair. The HPLC/UV with a column-switching method will be useful as a first step in screening surveys in order to better understand the effects of smoking exposure.
基金Supported by the Project of Science & Technology Plans in Heilongjiang Province in the 11th Five-year Period (GB07B407)
文摘Reversed-phase high-performance liquid chromatography (RP-HPLC) method with C4 column and C18 column for analyzing β-lactoglobulin and α-lactalbumin in bovine milk was developed and the performance and characteristic of two columns were compared. Shiseido Proteonavi C4 column (250 mm×4.6 mm×5μm) and Shiseido CAPCELL PAK SG 300 C18 column (250 mm× 4.6 mm×5 μm) were used in the experiment. Phase A was composed of 0.1% (V/V) trifluoroacetic acid (TFA) in ultrapure water and Phase B (organic phase) was composed of 0.1% TFA in acetonitrile. Gradient elution was taken. Flow rate was 1 mL min-1. The detection wavelength was 215 nm. The injection volume was 20 μL and the column temperature was 30℃. The results showed that linear relationship was good and recovery of α-lactalbumin and β-lactoglobulin was 86.12%-104.38%, C18 column had stronger ability to resist acid and more stable, and the method with C4 column had excellent sensitivities and good separation.
基金Supported by Open Project of the Key Laboratory of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base(201603)Basic Research Project of Application of Suzhou City(SNG201622)
文摘A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were minced and mixed,and extracted with ultra pure water at 90℃ for 20 min. The 6-aminoquinolyl N-hydroxy-succinimidyl carbamate( AQC) was used as pre-column derivatization reagent. Gradient HPLC separation was performed on a C_(18) column( Symmetry C_(18),3. 9 mm × 15 cm,4 μm). Good linearity between concentrations and peak areas was achieved in the concentration range of 5. 0-250 μmol/L for 18 kinds of amino acids. The method was validated by the analysis of five replicates. The 18 kinds of amino acid standards were spiked in fresh tea leaf samples and the average recovery rate was 86. 25%-109. 05% with relative standard deviations( n = 5) ranging from 6. 03% to 10. 56%. The limit of detection( LOD) for the analytes was0. 05-1. 27 μmol/L. The method was successfully applied to the analysis of the 18 kinds of amino acids in fresh tea leaves from east Dongting and west Dongting mountains in Suzhou. The results indicate that the method is simple,rapid,precise and reliable.
文摘High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral derivatization was developed. Cheap and easy available aromatic acid chlorides were used as derivatization agents. Good to excellent separations of the enantiomers were achieved in all cases in relatively short analytical runs. It was shown that the enantiorecognition depends on the substituents both in the starting alcohol and in the acid chloride. The method presents an efficient alternative to the direct analyses on polysaccharide and cyclodextrine-derived stationary phases.