Laser wakefield accelerators(LWFAs)offer acceleration gradients up to 1000 times higher than those of conventional radio-frequency accelerators,offering a pathway to significantly more compact and cost-effective accel...Laser wakefield accelerators(LWFAs)offer acceleration gradients up to 1000 times higher than those of conventional radio-frequency accelerators,offering a pathway to significantly more compact and cost-effective accelerator systems.This breakthrough opens up new possibilities for laboratory-scale light sources.All-optical inverse Compton scattering(AOCS)sources driven by LWFAs produce high-brightness,quasimonochromatic X rays with micrometer-scale source sizes,delivering the spatial coherence and resolution required for X-ray phase-contrast imaging(XPCI).These features position AOCS X-ray sources as promising tools for applications in biology,medicine,physics,and materials science.However,previous AOCS-based imaging studies have primarily focused on X-ray absorption imaging.In this work,we report successful experimental demonstrations of edge-enhanced in-line XPCI using energy-tunable,quasi-monochromatic AOCS X rays.With a spatial resolution of~20μm,our results clearly show the potential of high-resolution,AOCS-based XPCI applications.展开更多
This paper describes the design and performance of the tender energy spectroscopy beamline(BL16U1),a phase Ⅱ beamline,at the Shanghai Synchrotron Radiation Facility.The beamline,based on an in-vacuum undulator source...This paper describes the design and performance of the tender energy spectroscopy beamline(BL16U1),a phase Ⅱ beamline,at the Shanghai Synchrotron Radiation Facility.The beamline,based on an in-vacuum undulator source with 26 mm period,provides an operable energy range between 2.1 keV and 16 keV,covering the K-edges of P to Rb and L3-edges of Zr to Bi.The principal optical elements of the beamline are a toroidal mirror,a liquid nitrogen-cooled double-crystal monochromator,a high-harmonic-rejection mirror,and two pairs of Kirkpatrick–Baez(KB)mirrors.Three end-stations,including non-focusing,microprobe,and sub-microprobe types,are installed on the beamline.X-ray fluorescence(XRF)and X-ray absorption spectroscopy(XAS),including X-ray absorption near-edge structure(XANES)and extended X-ray absorption fine structure(EXAFS),are performed under vacuum or He atmosphere at the non-focusing end-station(with a beam spot size of∼670μm×710μm).Using two KB mirrors systems,micro-XRF(μXRF)mapping and micro-XANES(μXANES)studies can be performed with a spot size of approximately∼3.3μm×1.3μm at the microprobe end-station and with a smaller spot size of∼0.5μm×0.25μm at the sub-microprobe end-station.The non-focusing end-station was officially opened to users in January 2024.The microprobe and sub-microprobe end-stations will be opened to users in the near future.This paper presents the characteristics,short-term technical developments,and early experimental results of this new beamline.展开更多
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDB0530000)the Discipline Construction Foundation of“Double World-class Project”.
文摘Laser wakefield accelerators(LWFAs)offer acceleration gradients up to 1000 times higher than those of conventional radio-frequency accelerators,offering a pathway to significantly more compact and cost-effective accelerator systems.This breakthrough opens up new possibilities for laboratory-scale light sources.All-optical inverse Compton scattering(AOCS)sources driven by LWFAs produce high-brightness,quasimonochromatic X rays with micrometer-scale source sizes,delivering the spatial coherence and resolution required for X-ray phase-contrast imaging(XPCI).These features position AOCS X-ray sources as promising tools for applications in biology,medicine,physics,and materials science.However,previous AOCS-based imaging studies have primarily focused on X-ray absorption imaging.In this work,we report successful experimental demonstrations of edge-enhanced in-line XPCI using energy-tunable,quasi-monochromatic AOCS X rays.With a spatial resolution of~20μm,our results clearly show the potential of high-resolution,AOCS-based XPCI applications.
基金supported by the National Key R&D Program of China(No.2021YFA1601003)the financial support of the SSRF PhaseⅡproject.
文摘This paper describes the design and performance of the tender energy spectroscopy beamline(BL16U1),a phase Ⅱ beamline,at the Shanghai Synchrotron Radiation Facility.The beamline,based on an in-vacuum undulator source with 26 mm period,provides an operable energy range between 2.1 keV and 16 keV,covering the K-edges of P to Rb and L3-edges of Zr to Bi.The principal optical elements of the beamline are a toroidal mirror,a liquid nitrogen-cooled double-crystal monochromator,a high-harmonic-rejection mirror,and two pairs of Kirkpatrick–Baez(KB)mirrors.Three end-stations,including non-focusing,microprobe,and sub-microprobe types,are installed on the beamline.X-ray fluorescence(XRF)and X-ray absorption spectroscopy(XAS),including X-ray absorption near-edge structure(XANES)and extended X-ray absorption fine structure(EXAFS),are performed under vacuum or He atmosphere at the non-focusing end-station(with a beam spot size of∼670μm×710μm).Using two KB mirrors systems,micro-XRF(μXRF)mapping and micro-XANES(μXANES)studies can be performed with a spot size of approximately∼3.3μm×1.3μm at the microprobe end-station and with a smaller spot size of∼0.5μm×0.25μm at the sub-microprobe end-station.The non-focusing end-station was officially opened to users in January 2024.The microprobe and sub-microprobe end-stations will be opened to users in the near future.This paper presents the characteristics,short-term technical developments,and early experimental results of this new beamline.