期刊文献+
共找到46篇文章
< 1 2 3 >
每页显示 20 50 100
多物源体系下海陆过渡三角洲沉积模式及控储机制——以川西北中坝地区须二段为例
1
作者 贺书洲 程超 +4 位作者 赖强 谌丽 叶榆 冉丽君 曹建 《天然气地球科学》 北大核心 2025年第5期846-863,共18页
随着中国非常规油气事业的稳步推进,致密砂岩气已成为重要勘探领域。川西北须家河组二段(须二段)致密砂岩气藏普遍发育多物源体系下的海陆过渡三角洲沉积,优质储层展布规律复杂。以中坝地区为例,综合岩心、薄片、测录井等多种资料,以多... 随着中国非常规油气事业的稳步推进,致密砂岩气已成为重要勘探领域。川西北须家河组二段(须二段)致密砂岩气藏普遍发育多物源体系下的海陆过渡三角洲沉积,优质储层展布规律复杂。以中坝地区为例,综合岩心、薄片、测录井等多种资料,以多物源体系作为切入点,系统开展了物源、沉积特征及沉积模式的研究,进一步探讨了不同物源区成岩、裂缝及流动单元等方面的差异,最终揭示了须二段沉积模式及多物源控储机制。研究表明:①须二段同时接受米仓山和龙门山的物源供给,前者为主物源,不同物源体系的沉积物呈现出组构上的明显差异。②须二段表现为北西向和北东向2个扇三角洲前缘汇聚为一个统一的扇三角洲前缘的沉积模式。③多物源体系的综合控储机制表现为“直接影响原始沉积—直接影响成岩改造—间接控制裂缝发育带”,而流动单元能有效表征其综合控储效应。④多物源体系下物源共同控制区是重点勘探区域,尤其在致密储层中,沉积对储层的控制作用被弱化,多物源体系通过影响后期成岩和裂缝改造对储层的控制进一步增强。研究成果可以对川西北须二段有利勘探区优选提供指导。 展开更多
关键词 多物源体系 三角洲前缘 中坝地区 须家河组 沉积模式 控储机制
原文传递
Isolation and Screening of Lactic Acid Bacterial Strains with Antibacterial Properties from the Vaginas of Healthy Cows
2
作者 chao cheng Qiaozhen Tian +7 位作者 Shaofeng Su Hui Zhang Hongjie Guo Pengfei Gao Songhe Xu Zhiguo Liu Yanfen Ma Zhenjun Li 《Open Journal of Animal Sciences》 CAS 2022年第3期390-406,共17页
In the present study, eight strains were isolated from 20 cow vagina samples and identified using phenotype, biochemical analysis, sugar fermentation tests, and 16S rRNA sequence analysis. Among eight strains, only SQ... In the present study, eight strains were isolated from 20 cow vagina samples and identified using phenotype, biochemical analysis, sugar fermentation tests, and 16S rRNA sequence analysis. Among eight strains, only SQ0048 was identified as Lactobacillus johnsonii based on a series of biochemical testing (including the adhesion test, catalase test, bacteriocin production test, antibacterial test, and pH value), suggesting that its biological activity was superior to the other seven strains. Furthermore, SQ0048 had the lowest pH value (4.32) and the shortest fermentation time (8 h) compared with the other strains. The adhesion rate of SQ0048 was significantly higher than that of Lactobacillus delbrueckii, with an average adhesion number of 304 ± 2.67. The hydrogen peroxide production testing in SQ0048 was positive;in addition, bacteriocin gene of SQ0048, encoding an approximately 10-kDa product, was successfully cloned, expressed, and detected using the SDS-PAGE method. Meanwhile, SQ0048 had a weak inhibitory effect on Staphylococcus aureus and Escherichia coli. However, the expression products of the bacteriocin gene of SQ0048 had a very strong inhibitory effect on S. aureus and E. coli, with inhibition zone sizes of 18 ± 0.45 mm and 15 ± 0.60 mm, respectively. These data showed that SQ0048 has excellent antibacterial properties compared with other isolated strains and is a potential probiotic candidate to improve the health of the vaginas of cows by inhibiting pathogenic microorganisms. 展开更多
关键词 Antibacterial Properties COW Lactic Acid Bacteria SQ0048 VAGINA
在线阅读 下载PDF
基于空间位置关系的轨迹数据高效降维和查询算法 被引量:2
3
作者 巢成 蒲非凡 +1 位作者 许建秋 高云君 《计算机研究与发展》 EI CSCD 北大核心 2024年第7期1771-1790,共20页
由于新型信息技术的快速发展,社会处于数字化、信息化转型的关键时期,各行业对于以数据库技术为基础的信息系统的需求也日益凸显.基于位置的服务依赖于海量实时生成的轨迹数据,在处理亿万级随时间连续变化的轨迹数据时,降维算法和查询... 由于新型信息技术的快速发展,社会处于数字化、信息化转型的关键时期,各行业对于以数据库技术为基础的信息系统的需求也日益凸显.基于位置的服务依赖于海量实时生成的轨迹数据,在处理亿万级随时间连续变化的轨迹数据时,降维算法和查询技术一直是研究的关键,通过降低轨迹数据的规模,减少查询操作时处理数据的时间,能有效提升查询的性能,而能否实现高质量、高效率查询对于数据库而言至关重要.提出了面向轨迹数据的均匀网格编码,并在进一步优化后提出非均匀网格降维算法,将轨迹数据的坐标转化为1维字符串存储,对不符合要求的网格进行合并处理;通过空间位置映射充分保留轨迹数据间复杂的相互关系,并采用范围查询与最近邻查询对降维后的数据进行性能测试.实验使用不同城市真实轨迹数据与模拟生成轨迹数据作为数据集,将提出的均匀网格算法、非均匀网格算法与3种基准方法进行对比.实验证明,优化后的非均匀网格算法降维后数据的空间位置关系相似度可高达82.50%,范围查询时间较其他查询时间提升了至少73.86%,最近邻查询时间提升了至少52.26%,与其他基准方法相比取得了更好的效果. 展开更多
关键词 轨迹数据 降维算法 非均匀网格 空间位置关系 查询技术
在线阅读 下载PDF
海藻酸钠-g-聚丙烯酰胺/氧化石墨烯复合水凝胶的制备及控释行为 被引量:10
4
作者 邵宇 吴称意 +4 位作者 程超 李聪 张旭 郑寅 吴少尉 《高分子材料科学与工程》 EI CAS CSCD 北大核心 2018年第4期104-109,共6页
以海藻酸、丙烯酰胺为单体,氧化石墨烯为原料制备了海藻酸钠-g-聚丙烯酰胺/氧化石墨烯(NaAlg-g-PAAm/GO)复合水凝胶,采用傅里叶变换红外光谱和扫描电镜对其结构和形貌进行了表征;当GO的质量分数从0.6%增至3.2%时,溶胀率从37%减至21%;阳... 以海藻酸、丙烯酰胺为单体,氧化石墨烯为原料制备了海藻酸钠-g-聚丙烯酰胺/氧化石墨烯(NaAlg-g-PAAm/GO)复合水凝胶,采用傅里叶变换红外光谱和扫描电镜对其结构和形貌进行了表征;当GO的质量分数从0.6%增至3.2%时,溶胀率从37%减至21%;阳离子对水凝胶的溶胀性的影响能力是Fe3+>Ca2+>K+;以5-氟尿嘧啶(5-FU)为抗癌药物模型,模拟胃腔和小肠的环境,研究了在pH=1.2和pH=7.4的缓冲溶液中复合水凝胶的控制释放行为,实验结果表明水凝胶在pH=7.4的缓冲溶液中的累积释放率明显高于在pH=1.2的溶液中的累积释放率,所以该类水凝胶有望成为靶向药物释放的载体。 展开更多
关键词 复合水凝胶 控制释放 氧化石墨烯 溶胀
在线阅读 下载PDF
面向交通流预测的路况分级融合模型 被引量:2
5
作者 巢成 许建秋 《计算机应用》 CSCD 北大核心 2023年第S02期47-53,共7页
针对复杂交通网的路况拥堵问题,提出了L^(2)(LSTM(Long Short-Term Memory)+LGBM(Light Gradient Boosting Machine))融合模型,为道路决策提供数据驱动的基础,优化交通调度,提高出行效率。首先,通过前向关联边结构存储路网模型;其次,提... 针对复杂交通网的路况拥堵问题,提出了L^(2)(LSTM(Long Short-Term Memory)+LGBM(Light Gradient Boosting Machine))融合模型,为道路决策提供数据驱动的基础,优化交通调度,提高出行效率。首先,通过前向关联边结构存储路网模型;其次,提取历史序列数据特征,保留路网中的时序特征;最后,通过将时间序列数据与道路拓扑结构融合进行特征提取,训练模型并完成预测。为便于理解路段状态,采用分级评价,将预测结果划分为:拥堵、缓行和畅通。实验采用北京地区真实路况作为数据集,数据规模达1500余万条。实验将融合模型L^(2)与深度神经网络(DNN)、LSTM和LGBM做对比,实验结果表明,L^(2)的预测精度达91.22%,优于其他模型。最后,采用可视化技术展示实验结果,完成5种可视化图表的实现,便于用户直观理解道路的实时状态。 展开更多
关键词 交通流预测 融合模型 长短期记忆网络 轻量级梯度提升机 道路属性 可视化
在线阅读 下载PDF
Mechanical properties of electron beam welded dissimilar joints of TC17 and Ti60 alloys 被引量:13
6
作者 chao cheng Bingbing Yu +2 位作者 Zhiyong Chen Jianrong Liu Qingjiang Wang 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2018年第10期1859-1866,共8页
Microstructure, hardness, tensile and high cycle fatigue (HCF) properties of the welded dissimilar joints of Ti60 and TC17 titanium alloys had been investigated in this study. A significant microstructural change wa... Microstructure, hardness, tensile and high cycle fatigue (HCF) properties of the welded dissimilar joints of Ti60 and TC17 titanium alloys had been investigated in this study. A significant microstructural change was observed to occur after welding, with rod-like α and β phases in the fusion zone (FZ), equiaxed et phases, fine α laths and β phases in the heat-affected zone (HAZ) of TCl7 side and acicular martensite α' phases+"ghost" α phases in the HAZ of Ti60 side, The microhardness across the joints exhibited an inhomogeneous distribution with the highest hardness of ~404 HV in FZ and the lowest hardness of ~304 HV in base material (BM) of Ti60. All the joints tested in tension fractured at BM of Ti60 side. Fatigue limits of the joints at 107 cycles were 425 MPa at room temperature and 380 MPa at 400 ℃, respectively. Welding micropores were found to be the main source of fatigue crack initiation. 展开更多
关键词 Titanium alloy Electron beam welding Dissimilar joints Mechanical properties
原文传递
Percutaneous ultrasound and endoscopic ultrasound-guided biopsy of solid pancreatic lesions: An analysis of 1074 lesions 被引量:3
7
作者 Wei-Lu Chai Xiu-Feng Kuang +4 位作者 Li Yu chao cheng Xin-Yan Jin Qi-Yu Zhao Tian-An Jiang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2023年第3期302-309,共8页
Backgrounds:Percutaneous ultrasound(US)and endoscopic ultrasound(EUS)-guided pancreatic biopsies are widely accepted in the diagnosis of pancreatic diseases.Studies comparing the diagnostic performance of US-and EUS-g... Backgrounds:Percutaneous ultrasound(US)and endoscopic ultrasound(EUS)-guided pancreatic biopsies are widely accepted in the diagnosis of pancreatic diseases.Studies comparing the diagnostic performance of US-and EUS-guided pancreatic biopsies are lacking.This study aimed to evaluate and compare the diagnostic yields of US-and EUS-guided pancreatic biopsies and identify the risk factors for inconclusive biopsies.Methods:Of the 1074 solid pancreatic lesions diagnosed from January 2017 to February 2021 in our center,275 underwent EUS-guided fine needle aspiration(EUS-FNA),and 799 underwent US-guided core needle biopsy(US-CNB/FNA).The outcomes were inconclusive pathological biopsy,diagnostic accuracy and the need for repeat biopsy.All of the included factors and diagnostic performances of both USCNB/FNA and EUS-FNA were compared,and the independent predictors for the study outcomes were identified.Results:The diagnostic accuracy was 89.8%for EUS-FNA and 95.2%for US-CNB/FNA(P=0.001).Biopsy under EUS guidance[odds ratio(OR)=1.808,95%confidence interval(CI):1.083-3.019;P=0.024],lesion size<2 cm(OR=2.069,95%CI:1.145-3.737;P=0.016),hypoechoic appearance(OR=0.274,95%CI:0.097-0.775;P=0.015)and non-pancreatic ductal adenocarcinoma carcinoma(PDAC)diagnosis(OR=2.637,95%CI:1.563-4.449;P<0.001)were identified as factors associated with inconclusive pathological biopsy.Hypoechoic appearance(OR=0.236,95%CI:0.064-0.869;P=0.030),lesions in the uncinate process of the pancreas(OR=3.506,95%CI:1.831-6.713;P<0.001)and non-PDAC diagnosis(OR=2.622,95%CI:1.278-5.377;P=0.009)were independent predictors for repeat biopsy.Biopsy under EUS guidance(OR=2.024,95%CI:1.195-3.429;P=0.009),lesions in the uncinate process of the pancreas(OR=1.776,95%CI:1.014-3.108;P=0.044)and hypoechoic appearance(OR=0.127,95%CI:0.047-0.347;P<0.001)were associated with diagnostic accuracy.Conclusions:In conclusion,both percutaneous US-and EUS-guided biopsies of solid pancreatic lesions are safe and effective;though the diagnostic accuracy of EUS-FNA is inferior to US-CNB/FNA.A tailored pancreatic biopsy should be considered a part of the management algorithm for the diagnosis of solid pancreatic disease. 展开更多
关键词 PANCREATIC BIOPSY Fine needle aspiration ULTRASOUND Endoscopic ultrasound
暂未订购
晚期外伤性支气管断裂闭锁经支气管镜下介入治疗2例诊治体会 被引量:3
8
作者 程超 吕莉萍 《中国内镜杂志》 2020年第4期82-84,共3页
目的探讨晚期外伤性支气管断裂闭锁经支气管镜下介入治疗的可行性。方法采用支气管镜下微波、球囊扩张和冷冻等多种支气管镜下介入手段治疗,以期实现晚期外伤性支气管断裂闭锁的再通。结果2例晚期外伤性支气管断裂闭锁患者经支气管镜下... 目的探讨晚期外伤性支气管断裂闭锁经支气管镜下介入治疗的可行性。方法采用支气管镜下微波、球囊扩张和冷冻等多种支气管镜下介入手段治疗,以期实现晚期外伤性支气管断裂闭锁的再通。结果2例晚期外伤性支气管断裂闭锁患者经支气管镜下介入治疗后,均实现了闭锁支气管的再通,明显改善了患者临床症状。结论支气管镜下介入治疗可有效实现晚期外伤性支气管断裂闭锁的再通,提供了一种新的治疗手段。 展开更多
关键词 外伤性支气管断裂 晚期 支气管镜 介入治疗 支气管再通
暂未订购
Highly active electrocatalysis of hydrogen evolution reaction in alkaline medium by Ni–P alloy: A capacitance-activity relationship 被引量:2
9
作者 chao cheng Syed Shoaib Ahmad Shah +3 位作者 Tayyaba Najam Ling Zhang Xueqiang Qi Zidong Wei 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2017年第6期1245-1251,共7页
Different weights of amorphous Ni–P alloy with same P contents were electrodeposited on nickel plate with same area used as cathode for hydrogen evolution reaction(HER). The amorphous Ni–P alloy coatings were charac... Different weights of amorphous Ni–P alloy with same P contents were electrodeposited on nickel plate with same area used as cathode for hydrogen evolution reaction(HER). The amorphous Ni–P alloy coatings were characterized for their surface morphology and composition through Scanning electron microscopy(SEM) and Energy dispersive X-ray spectroscopy(EDS) techniques, X-ray photoelectron spectroscopy(XPS) and X-ray diffraction(XRD) analysis. The electrocatalytic activity for HER in alkaline medium is determined by linear scan voltammetry(LSV) and a relationship between HER activity and capacitance is established. The capacitance varies with the loading of the Ni–P on Ni plate but the activity for HER is directly proportional to the capacitance in alkaline and vice versa. 3#Ni–P/Ni containing 3.85 mg Ni–P alloy with highest capacitance performs the best catalytic activity. This work provides direct evidence to explore the capacitance influence on the electrocatalystic activity for the HER. 展开更多
关键词 HER Ni–P alloy CAPACITANCE ELECTRODEPOSITION
在线阅读 下载PDF
Advances and future directions in keloid research:Pathogenesis,diagnosis and personalized treatment strategies 被引量:4
10
作者 Song-Yun Zhao Dan Wu +1 位作者 chao cheng Jia-Heng Xie 《World Journal of Clinical Cases》 SCIE 2023年第34期8094-8098,共5页
Keloids,which are abnormal manifestations of wound healing,can result in significant functional impairment and aesthetic deformities.The pathogenesis of keloids is multifaceted and complex and influenced by various fa... Keloids,which are abnormal manifestations of wound healing,can result in significant functional impairment and aesthetic deformities.The pathogenesis of keloids is multifaceted and complex and influenced by various factors,such as genetics,the environment,and immune responses.The evolution of keloid treatment has progressed from traditional surgical excision to a contemporary combination of therapies including injection and radiation treatments,among others.This article provides a comprehensive review of keloid pathogenesis and treatment,emphasizing the latest advances in the field.Ultimately,this review underscores the necessity for continued research to enhance our understanding of keloid pathogenesis and to devise more effective treatments for this challenging condition. 展开更多
关键词 KELOIDS PATHOGENESIS DIAGNOSIS Treatment Personalized therapy
暂未订购
Prognostic values of optic nerve sheath diameter for comatose patients with acute stroke:An observational study 被引量:2
11
作者 Sha Zhu chao cheng +3 位作者 Liu-Liu Wang Dian-Jiang Zhao Yuan-Li Zhao Xian-Zeng Liu 《World Journal of Clinical Cases》 SCIE 2022年第33期12175-12183,共9页
BACKGROUND Optic nerve sheath diameter(ONSD)measurement is one of the non-invasive methods recommended for increased intracranial pressure(ICP)monitoring.AIM This study aimed to evaluate the roles of optic nerve sheat... BACKGROUND Optic nerve sheath diameter(ONSD)measurement is one of the non-invasive methods recommended for increased intracranial pressure(ICP)monitoring.AIM This study aimed to evaluate the roles of optic nerve sheath diameter(ONSD)and ONSD/eyeball transverse diameter(ETD)ratio in predicting prognosis of death in comatose patients with acute stroke during their hospitalization.METHODS A total of 67 comatose patients with acute stroke were retrospectively recruited.The ONSD and ETD were measured by cranial computed tomography(CT)scan.All patients underwent cranial CT scan within 24 h after coma onset.Patients were divided into death group and survival group according to their survival status at discharge.The differences of the ONSD and ONSD/ETD ratio between the two groups and their prognostic values were compared.RESULTS The ONSD and ONSD/ETD ratio were 6.07±0.72 mm and 0.27±0.03 in the comatose patients,respectively.The ONSD was significantly greater in the death group than that in the survival group(6.32±0.67 mm vs 5.65±0.62 mm,t=4.078,P<0.0001).The ONSD/ETD ratio was significantly higher in the death group than that in the survival group(0.28±0.03 vs 0.25±0.02,t=4.625,P<0.0001).The area under the receiver operating characteristic curve was 0.760(95%CI:0.637-0.882,P<0.0001)for the ONSD and 0.808(95%CI:0.696-0.920,P<0.0001)for the ONSD/ETD ratio.CONCLUSION The mortality increased in comatose patients with acute stroke when the ONSD was>5.7 mm or the ONSD/ETD ratio was>0.25.Both indexes could be used as prognostic tools for comatose patients with acute stroke.The ONSD/ETD ratio was more stable than the ONSD alone,which would be preferred in clinical practice. 展开更多
关键词 Optic nerve sheath diameter Eyeball transverse diameter COMA Intracranial pressure STROKE PROGNOSIS
暂未订购
Major complications after ultrasound-guided liver biopsy:An annual audit of a Chinese tertiary-care teaching hospital 被引量:2
12
作者 Wei-Lu Chai Dan-Lei Lu +8 位作者 Zhong-Xia Sun chao cheng Zhuang Deng Xin-Yan Jin Tong-Long Zhang Qiong Gao Yu-Wei Pan Qi-Yu Zhao Tian-An Jiang 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第7期1388-1396,共9页
BACKGROUND As ultrasound-guided percutaneous liver biopsy(PLB)has become a standard and important method in the management of liver disease in our country,a periodical audit of the major complications is needed.AIM To... BACKGROUND As ultrasound-guided percutaneous liver biopsy(PLB)has become a standard and important method in the management of liver disease in our country,a periodical audit of the major complications is needed.AIM To determine the annual incidence of major complications following ultrasoundguided PLB and to identify variables that are significantly associated with an increased risk of major complications.METHODS A total of 1857 consecutive cases of PLB were included in our hospital from January 2021 to December 2021.The major complication rate and all-cause 30-d mortality rate were determined.Multivariate analyses were performed by logistic regression to investigate the risk factors associated with major complications and all-cause 30-d mortality following ultrasound-guided PLB.RESULTS In this audit of 1857 liver biopsies,10 cases(0.53%)of major complications occurred following ultrasound-guided PLB.The overall all-cause mortality rate at 30 d after PLB was 0.27%(5 cases).Two cases(0.11%)were attributed to major hemorrhage within 7 d after liver biopsy.Fibrinogen less than 2 g/L[odds ratio(OR):17.226;95%confidence interval(CI):2.647-112.102;P=0.003],post-biopsy hemoglobin level(OR:0.963;95%CI:0.942-0.985;P=0.001),obstructive jaundice(OR:6.698;95%CI:1.133-39.596;P=0.036),application of anticoagulants/antiplatelet medications(OR:24.078;95%CI:1.678-345.495;P=0.019)and age(OR:1.096;95%CI:1.012-1.187;P=0.025)were statistically associated with the incidence of major complications after PLB.CONCLUSION In conclusion,the results of this annual audit confirmed that ultrasound-guided PLB can be performed safely,with a major complication rate within the accepted range.Strict patient selection and peri-biopsy laboratory assessment are more important than procedural factors for optimizing the safety outcomes of this procedure. 展开更多
关键词 Liver PERCUTANEOUS BIOPSY Ultrasound COMPLICATION
暂未订购
Anti-viral activity of Staphylococcus aureus lysates against herpes simplex virus type-Ⅰinfection:an in vitro and in vivo study 被引量:1
13
作者 Tian-Lan Lin chao cheng +5 位作者 Wei-Ting Zeng Fang Duan Yin-Hui Pei Xiu-Ping Liu Fu Shang Kai-Li Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第10期1463-1472,共10页
AIM:To investigate the effect of Staphylococcus aureus(S.aures)lysates(SALs)on herpes simplex virus type-Ⅰ(HSV1)infection in human corneal epithelial(HCE)cells and in a mouse model of HSV1 keratitis.METHODS:HCE,Vero,... AIM:To investigate the effect of Staphylococcus aureus(S.aures)lysates(SALs)on herpes simplex virus type-Ⅰ(HSV1)infection in human corneal epithelial(HCE)cells and in a mouse model of HSV1 keratitis.METHODS:HCE,Vero,HeLa,and BV2 cells were infected with HSV1[HSV1f strain,HSV1f;HSV-1-H129 with green fluorescent protein(GFP)knock-in,HSV1g].Pre-or post-infection,SAL at various concentrations was added to the culture medium for 24 h.GFP fluorescence in HSV1g or plaque formation by HSV1f were examined.The effects of heat-treated SAL,precooled acetone-precipitated SAL,and SAL subjected to ultrafiltration(100 kDa)were evaluated.The effects of other bacterial components and lysates on HSV1 infection were also tested,including lipoteichoic acid(LTA),peptidoglycan(PGN),staphylococcal protein A(SPA),andα-hemolysin from S.aureus(α-toxin)as well as lysates from a wild-type S.aureus strain,S.epidermidis,and Escherichia coli(W-SAL,SEL,and ECL,respectively).In addition,SAL eye drops were applied topically to BALB/c mice with HSV1 keratitis,followed by in vivo observations.RESULTS:The cytopathic effect,plaque formation(HSV1f),and GFP expression(HSV1g)in infected cells were inhibited by SAL in a dose-dependent manner.The active component of SAL(≥100 kDa)was heat-sensitive and retained activity after acetone precipitation.In HSV1ginfected cells,treatment with LTA-sa,α-toxin,PGN-sa,or SPA did not inhibit GFP expression.SAL,W-SAL,and SEL(but not ECL)decreased GFP expression.In mice with HSV1 keratitis,SAL reduced corneal lesions by 71%.CONCLUSION:The results of this study demonstrate that SAL can be used to inhibit HSV1 infection,particularly keratitis.Further studies are needed to determine the active components and mechanism underlying the effects of SAL. 展开更多
关键词 herpes simplex virus type-1 Staphylococcus aureus INFECTION cornea epithelial cells KERATITIS
原文传递
半径确定的最小二乘圆拟合法在电缆卷绕监测中的应用 被引量:1
14
作者 范巍 程超 张静怡 《传感器技术与应用》 2019年第4期134-141,共8页
针对在电缆卷绕状态的监测中仅使用最小二乘法,而对电缆规格信息利用不充分的问题,设计了一种改进的圆拟合方法:半径确定的最小二乘圆拟合法,并以实验的方式研究了传感器角度分辨率、电缆直径、电缆外表面材料等诸多因素对电缆相对位置... 针对在电缆卷绕状态的监测中仅使用最小二乘法,而对电缆规格信息利用不充分的问题,设计了一种改进的圆拟合方法:半径确定的最小二乘圆拟合法,并以实验的方式研究了传感器角度分辨率、电缆直径、电缆外表面材料等诸多因素对电缆相对位置拟合精度的影响。实验结果表明:影响拟合精度的主要因素为测量数据的精度,而对于常见黑色橡胶外表的电缆,当传感器的随机测量误差小于7 mm时,本算法可以保证电缆相对位置的拟合误差小于1.5 mm。 展开更多
关键词 电缆状态检测 半径确定 最小二乘法 拟合精度 黑色橡胶
在线阅读 下载PDF
湖北海棠叶化学成分及其应用研究进展 被引量:2
15
作者 巢诚 吕凯波 袁屹高 《现代食品》 2024年第8期19-21,共3页
湖北海棠叶是2014年卫生部第20号公告批准的新食品原料,其研究价值主要集中于生物活性成分。基于此,本文归纳了现阶段国内外湖北海棠叶生物活性成分及其提取方法,并从生物活性成分、生理功能等方面综述相关研究进展,以期为湖北海棠叶的... 湖北海棠叶是2014年卫生部第20号公告批准的新食品原料,其研究价值主要集中于生物活性成分。基于此,本文归纳了现阶段国内外湖北海棠叶生物活性成分及其提取方法,并从生物活性成分、生理功能等方面综述相关研究进展,以期为湖北海棠叶的创新应用提供思路。 展开更多
关键词 湖北海棠叶 活性成分 应用 进展
在线阅读 下载PDF
Reinforcing oxygen electrocatalytic activity via selective dualphase heterointerface engineering for rechargeable Zn-air batteries
16
作者 chao cheng Chuang Zhi +9 位作者 Zhong-Ti Sun Yong-Qiang Ming Ting-Ting Xiang Qing-chao Zhu Zi-Rui Wu Bing Li Yi Li cheng Jin Yong Cao Juan Yang 《Rare Metals》 SCIE EI CAS CSCD 2024年第4期1524-1536,共13页
Dual-phase heterointerface electrocatalysts(DPHE)constructed by oxygen reduction reaction(ORR)-and oxygen evolution reaction(OER)-active elements exhibit excellent bifunctional activity and long-term durability due to... Dual-phase heterointerface electrocatalysts(DPHE)constructed by oxygen reduction reaction(ORR)-and oxygen evolution reaction(OER)-active elements exhibit excellent bifunctional activity and long-term durability due to the abundant interface exposure and synergistic catalytic effect.Herein,low-dimensional N-doped graphene nanoribbons(N-GNRs)coupling with ultrathin CoO nanocomposites(N-GNRs/CoO)were controllably fabricated through a facile two-step approach using synthesized Co(OH)_2 nanosheet as CoO precursor.Density functional theory(DFT)calculations and experimental characterizations prove that the formation of interface between N-GNRs and CoO can induce local charge redistribution,contributing to the improvement of catalytic activity and stability.The optimal N-GNRs/CoO DPHE possesses hierarchically porous architectures and presents outstanding bifunctional activities with a small potential gap of 0.729 V between the potential at 10 mA·cm^(-2)for OER and the halfwave potential for ORR,which outperforms Pt/C+IrO_(2)and the majority of noble-metal-free bifunctional catalysts.Liquid-and solid-state rechargeable Zn-air batteries assembled with N-GNRs/CoO as the cathode also display high peak power density and fantastic cycle stability,superior to that of benchmark Pt/C+IrO_(2)catalyst.It is anticipated to offer significant benefits toward high activity,stability and mechanical flexibility bifunctional oxygen electrocatalysts for rechargeable Zn-air batteries. 展开更多
关键词 Interface engineering Graphene nanoribbons CoO Bifunctional electrocatalyst Zn-air batteries
原文传递
The effect of COVID-19 vaccines on sperm parameters: a systematic review and meta-analysis
17
作者 Yu-cheng Ma chao cheng +3 位作者 Chi Yuan Li-Yuan Xiang Jun Wen Xi Jin 《Asian Journal of Andrology》 SCIE CAS CSCD 2023年第4期468-473,共6页
Published data were gathered for a meta-analysis to determine the difference in sperm parameters before and after administration of different types of coronavirus disease 2019(COVID-19)vaccines,because the reproductiv... Published data were gathered for a meta-analysis to determine the difference in sperm parameters before and after administration of different types of coronavirus disease 2019(COVID-19)vaccines,because the reproductive toxicity of COVID-19 vaccines has not yet been evaluated in clinical trials and COVID-19 has been associated with decreases in sperm quality.The preferred procedures for systematic reviews and meta-analyses were followed in the conduct and reporting of this study.The average sperm parameters of all sperm donors’multiple sperm donations were compared before and after receiving various COVID-19 vaccinations.Semen volume,total sperm motility,total sperm count,morphological change,and sperm concentration were the primary outcome measures.We compiled and analyzed the results of six studies on total sperm motility,six studies on semen volume,six studies on sperm concentration,two studies on morphological change,and two studies on total sperm count.Parameter comparisons with patients who had and had not been vaccinated were only reported in one of the included studies.When different types of COVID-19 vaccine injections were compared,no discernible differences in parameters were observed.According to the available data,the parameters of semen are unaffected by inactivated or messenger RNA(mRNA)COVID-19 vaccinations.To support these findings,additional prospectively designed research is required. 展开更多
关键词 COVID-19 mRNA vaccine sperm parameters sperm quality vaccine safety
原文传递
Synthesis,physical properties,and annealing investigation of new layered Bi-chalcogenide LaOBiHgS_(3)
18
作者 Yi Yu Chunchang Wang +4 位作者 Liang Li Qiuju Li chao cheng Shuting Wang Changjin Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第1期580-583,共4页
The transport and thermoelectric properties together with annealing of the new layered Bi-chalcogenide LaOBiHgS_(3)are studied.On the transport part,the insulating behavior of the as-grown sample is evidently depresse... The transport and thermoelectric properties together with annealing of the new layered Bi-chalcogenide LaOBiHgS_(3)are studied.On the transport part,the insulating behavior of the as-grown sample is evidently depressed by post annealing.A hump-like abnormality appears around 170 K.The thermoelectric performance of the sample is observably improved by the annealing,mainly because of the enhanced electrical conductance.The present results suggest that the physical properties of LaOBiHgS_(3)are sensitive to post annealing and the possible micro adjustments that follow,indicating the layered Bi-chalcogenide family to be an ideal platform for designing novel functional materials. 展开更多
关键词 THERMOELECTRIC material Bi-chalcogenide POST ANNEALING
原文传递
Insights into Formation and Li-Storage Mechanisms of Hierarchical Accordion-Shape Orthorhombic CuNb_(2)O_(6)toward Lithium-Ion Capacitors as an Anode-Active Material
19
作者 chao cheng Yunsheng Yan +3 位作者 Minyu Jia Yang Liu Linrui Hou Changzhou Yuan 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第2期287-298,共12页
The orthorhombic CuNb_(2)O_(6)(O-CNO)is established as a competitive anode for lithium-ion capacitors(LICs)owing to its attractive compositional/structural merits.However,the high-temperature synthesis(>900℃)and c... The orthorhombic CuNb_(2)O_(6)(O-CNO)is established as a competitive anode for lithium-ion capacitors(LICs)owing to its attractive compositional/structural merits.However,the high-temperature synthesis(>900℃)and controversial charge-storage mechanism always limit its applications.Herein,we develop a low-temperature strategy to fabricate a nano-blocks-constructed hierarchical accordional O-CNO framework by employing multilayered Nb_(2)CT_(x)as the niobium source.The intrinsic stress-induced formation/transformation mechanism of the monoclinic CuNb_(2)O_(6)to O-CNO is tentatively put forward.Furthermore,the integrated phase conversion and solid solution lithium-storage mechanism is reasonably unveiled with comprehensive in(ex)situ characterizations.Thanks to its unique structural merits and lithium-storage process,the resulted O-CNO anode is endowed with a large capacity of 150.3 mAh g^(-1)at 2.0 A g^(-1),along with long-duration cycling behaviors.Furthermore,the constructed O-CNO-based LICs exhibit a high energy(138.9 Wh kg^(-1))and power(4.0 kW kg^(-1))densities with a modest cycling stability(15.8%capacity degradation after 3000 consecutive cycles).More meaningfully,the in-depth insights into the formation and charge-storage process here can promote the extensive development of binary metal Nb-based oxides for advanced LICs. 展开更多
关键词 high-rate anodes lithium-ion capacitors lithium-storage mechanisms orthorhombic CuNb_(2)O_(6) phase transform
在线阅读 下载PDF
Application of Submerged Ultrafiltration in Pretreatment of Flue Gas Desulfurization Wastewater
20
作者 Jiageng Zhang Zhengfeng Wang +3 位作者 Jiguang Huang chao cheng Heng Zhang Dan Gao 《Energy Engineering》 EI 2022年第6期2277-2296,共20页
Nowadays,the zero liquid discharge of flue gas desulfurization(FGD)wastewater from coal-fired units has attracted the attention of all countries in the world.The pretreatment methods generally have the problems of hig... Nowadays,the zero liquid discharge of flue gas desulfurization(FGD)wastewater from coal-fired units has attracted the attention of all countries in the world.The pretreatment methods generally have the problems of high operation cost,small treatment capacity,and poor flexibility.However,the membrane method can avoid the above problems.In the current research,it has not been found that someone directly uses submerged ultrafiltration to pretreat FGD wastewater.Therefore,this paper innovatively proposed to directly use ceramic ultrafiltration membrane to treat FGD wastewater,which can ensure effluent quality and improve the flexibility of the pretreatment system.In this paper,the performance of submerged ultrafiltration membrane for the filtration of FGD wastewater from a power plant was studied to optimize the filtration performance and improve the effluent quality.The effects of operating parameters such as membrane permeate flux,aeration rate and filtration/backwashing time combination on the membrane performance were studied.The results showed that when the filtration/backwashing time combination was 15 min/30 s,with the increased in permeate flux from 55 L/(m2·h)to 100 L/(m2·h),the steady transmembrane pressure(TMP)increased from 39 kPa to 70 kPa,and the fouling rate increased significantly from 4.5 kPa/h to 7.3 kPa/h;When the aeration rate increased from 10 m3/(m2·h)to 30 m3/(m2·h),the membrane pollution was much reduced.Excessive aeration rate cannot further alleviate the membrane pollution,but also brought greater energy consumption;Increasing backwashing time can effectively inhibit the formation of gel layer on the surface of the membrane and prolong the initial stage of low-pressure operation;The rejection of suspended solids(SS)and turbidity of the equipment studied in this paper can reach more than 99%under various working conditions,which can satisfy the water quality requirements of the subsequent steps.The submerged ultrafiltration membrane was suitable for the pretreatment of FGD wastewater because it can ensure the quality of permeate under the premise of long-term operation. 展开更多
关键词 FGD wastewater PRETREATMENT submerged ultrafiltration permeate flux aeration rate BACKWASHING membrane fouling
在线阅读 下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部